• 제목/요약/키워드: Collection 6

검색결과 2,661건 처리시간 0.026초

공기 중 Toluene diisocyanates 측정방법에 따른 포집농도 비교 (A Comparison of Collection Concentrations Based on Airborne Toluene Diisocyanates Measurement Methods)

  • 박형성;원종욱;김치년;노재훈
    • 한국산업보건학회지
    • /
    • 제23권4호
    • /
    • pp.341-347
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the differences in airborne TDI concentrations based on the filter collection method and liquid collection method and to compare airborne TDIs concentrations by sampling method change when using the filter collection method in the spray-painting process. Methods: For the sample measurement, the filter collection method(OSHA#42) and liquid collection method(NIOSH#5522) were used; for the sampling method, the full-period single sampling and full-period consecutive sampling methods were used. The samples were collected in spray-painting and drying process locations. Results: In all samples collected from the spray-painting and drying process locations through the filter collection and liquid collection methods, greater amounts of 2,6-TDI than 2,4-TDI were detected. When the TDI collection concentrations based on the sampling methods were compared, the concentrations of 2,4-TDI and 2,6-TDI collected by the consecutive sampling method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the single sampling method for both the filter collection method and liquid collection method used in the spray-painting process. These differences were statistically significant. Conclusions: When TDI collection concentrations based on the sample measurement methods were compared, the concentration of 2,4-TDI and 2,6-TDI collected through the liquid collection method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the filter collection method, and the differences were statistically significant. In the drying process, no difference was shown in the collection concentrations of 2,4-TDI and 2,6-TDI with the two measurement methods.

대학도서관 장서관리 웹사이트 컨텐츠구성에 관한 연구 (A Study on the Construction of Contents for Collection Management Web Sites of University Libraries)

  • 윤혜영
    • 한국문헌정보학회지
    • /
    • 제36권1호
    • /
    • pp.165-186
    • /
    • 2002
  • 본 연구는 인터넷이라는 새로운 정보기술을 활용하여 장서관리에 대한 정보를 제공하고 있는 미국 대학도서관 웹사이트의 현황을 살펴보고 구성요소별 내용평가를 통해 웹사이트를 분석하고, 나아가 장서관리의 목적과 특성에 맞는 사이트를 체계적으로 운영할 수 있는 장서관리 웹사이트의 컨텐츠 구성을 목적으로 한다. 컨텐츠 구성은 <장서개발정책>, <직원주소록>, <통계>, <선정도구>, <구입 희망자료 신청>, <신간안내>의 6개 영역으로 구분된다. 웹사이트의 활용을 통해 장서관리 업무의 효율화를 이룸으로써 향후 장서관리 웹사이트를 구축하고자 하는 도서관에게 보다 합리적이고 체계적으로 나아갈 방향을 제시하고자 한다.

A Study on Automation of Image Collection Planning

  • Han, Jae-Joong;Jung, Kyung-Jin;Choi, Jae-Seung;Kwak, Sung-Hee;Kim, Moong-Yu
    • 대한원격탐사학회지
    • /
    • 제27권6호
    • /
    • pp.743-752
    • /
    • 2011
  • One of main concerns of operators of the Earth observation satellite is taking images as many as possible under the constraints of satellite resources during fixed period. In order to achieve this goal, satellite operators are strongly required to generate the optimized image collection plans, and it is a very time consuming process to achieve an optimized image collection plan when it is done by manual. This paper suggests automation of image collection planning based on the dynamic programming algorithm to reduce the time required for image collection planning. The validity of the proposed method is tested using operating satellite system and the result is given in this paper.

2단 선회류 약화기가 원심력집진기의 집진효율에 미치는 영향 (Effects of Two Stage Vortex Finder on the Particulate Collection Efficiency of Cyclone Separator)

  • 강순국;유경선
    • 한국대기환경학회지
    • /
    • 제16권6호
    • /
    • pp.633-640
    • /
    • 2000
  • The effects of structure modification of the vortex finder on the collection efficiency and pressure drop have been investigated. The pressure drop in a cyclone having the two stage vortex finder is higher than that in a conventional cyclone and increases proportionally with the increase of square of gas inlet velocity in both cases. The pressure drop of both conventional cyclone of friction resistance at the boundary layer. The collection efficiency of fine dust has been enhanced by addition of vortex finder in a conventional cyclone and gas inlet velocity showing maximum dust removal efficiency increase to 17 m/s(1.7 times of saltation velocity). Optimum size of two stage vortex finder has been induced to 13 cm I.D$\times$2.6cm Length from the results of overall dust collection efficiency. Previous models were tested for the simulation of collection efficiency of cyclone having two stage vortex finder and the Dietz model predict the similar value with experimental results of the present study.

  • PDF

Characteristics of Seed and Plant Growth in Local Collections of Agastache rugosa

  • Ok, Hyun-Chung;Chae, Young-Am
    • 한국작물학회지
    • /
    • 제43권4호
    • /
    • pp.269-272
    • /
    • 1998
  • Characteristics of seed and plant growth of the nine local collections of the medicinal plant, Agastache rugosa were evaluated. Seed size of the collection from Garyungsan was larger than the others. Seeds of Damyang collection were the smallest in size. Seeds of the collections were mostly oval shaped. There were no differences between brown and black seed coat color groups in seed width, ratio of seed length to seed width and 1,000 seed weight. Stem lengths of Garyungsan and Bongpyung collections were 99.9 and 95.6 cm, respectively, and were longer than Damyang and Jindo collections. Garyungsan collection had long leaf shape. Leaf size was the smallest for Damyang collection, but was the largest for Bongpyung collection. Inflorescence length of Mokpo collection (15.6 cm) was longer than the average over all collections (12.3 cm). Damyang collection was the shortest (10.1 cm) in inflorescence. Top dry weight of each collection from Soonchun, Bongpyung, Mokpo, Jindo, and Gurye was greater than the average over all collections (20.38 g/plant). Jinju and Damyang collections had less top dry matter than others. There was no difference in the growth traits examined between brown and black seed coat groups. The brown seed group was greater in leaf weight than the black seed group. However, these two groups were not different in stem and inflorescence weight. Collections of A. rugosa from Bongpyung, Soonchun, and Mokpo were promising for commercial cultivation because of their great top dry weight, especially in leaf and inflorescence.

  • PDF

Collection 5와 Collection 6 Aqua MODIS07_L2 기온과 이슬점온도 산출물간의 비교 및 지상 관측 자료와의 비교 (Comparisons of Collection 5 and 6 Aqua MODIS07_L2 air and Dew Temperature Products with Ground-Based Observation Dataset)

  • 장근창;강신규;홍석영
    • 대한원격탐사학회지
    • /
    • 제30권5호
    • /
    • pp.571-586
    • /
    • 2014
  • Moderate Resolution Imaging Spectroradiometer(MODIS)로부터 산출된 기온과 이슬점 온도프로파일 자료는 5 km의 공간해상도로 연속적으로 지상을 감시하고 있으며, 2012년부터 기존의 산출 알고리즘(Collection 5, C005)을 개선한 Collection 6(C006) MODIS07_L2 대기프로파일 자료를 생산하고 있다. 이 연구에서는 두 가지 버전의 알고리즘으로 산출된 Aqua MODIS07_L2(MYD07_L2) 대기 프로파일 자료로부터 획득한 기온과 이슬점 온도에 대한 신뢰도를 평가하는 것으로, 전국 77 개소 정규기상관측지점을 대상으로 하였다. 또한 기온과 이슬점 온도를 이용하여 대기수증기압을 추정하여 미기상인자 산출에 대한 MYD07_L2의 적용 가능성을 살펴보았다. C006 기온은 지상 관측 자료와 비교에서 C005 기온의 오차(ME = -1.89 K, RMSE = 4.06 K)보다 개선된 결과를 보였다(ME = -0.76 K, RMSE = 3.34 K). 한편, 이슬점 온도의 경우에는 C006이 C005의 오차(ME = -0.39 K, RMSE = 5.65 K)보다 크게 나타났다. MYD07_L2 산출 고도와 지상 관측지점 간에 발생할 수 있는 고도 차이를 보정하기 위해 대기기온감률 방법을 적용한 결과, 기온의 경우 C005와 C006에서 모두 개선 효과를 확인할 수 있었지만, 이슬점 온도의 경우에는 C006에서 오차가 소폭 증가하였다(1.4%). 두 가지 버전의 MYD07_L2 자료를 이용하여 대기수증기압을 추정한 결과, C006 자료를 이용하였을 때 다소 개선된 결과를 보였다. 이 연구를 통해 한국에 대한 C006 MYD07_L2 산출물 중 기온의 신뢰도가 전반적으로 개선되었음을 확인할 수 있었다.

이용계수를 적용한 공공도서관 소설장서 평가 (Evaluation of the Fiction Collection of Public Libraries Based on Use Factor)

  • 윤희윤;김일영
    • 정보관리연구
    • /
    • 제42권4호
    • /
    • pp.175-194
    • /
    • 2011
  • 본 연구는 이용계수를 적용하여 국내 공공도서관의 소설장서를 평가하고 장서개발기능을 제고시키기 위한 다양한 방안을 제시하였다. 그 결과, 한국문학은 언어별 문학에서의 장서구성 및 이용대출 비중이 각각 62.6%와 54.3%로 가장 높았음에도 불구하고 이용계수(0.87)는 기준값(1.00)보다 낮았다. 또한 한국현대소설은 한국소설의 세목별 장서구성 및 이용대출에서의 비중이 각각 65.60%와 51.36%로 가장 높음에도 이용계수(0.78)는 기준값보다 낮았고 연도별 이용계수도 최근 연도에 근접할수록 감소하고 있다. 그 이유는 장서개발이 부실하기 때문이다. 그러므로 공공도서관은 장서개발정책 및 소설장서개발지침의 수립, 소설자료선정위원회의 구성, 소설자료개발 전담사서제 도입, 소설자료 선정도구의 개발과 활용, 소설장서의 주기적 평가와 같은 방안의 도입을 적극적으로 검토할 필요가 있다.

Effect of Preservation Periods and Subcultures on Fruiting Body Formation of Cordyceps militaris In Vitro

  • Sung, Jae-Mo;Park, Young-Jin;Lee, Je-O;Han, Sang-Kuk;Lee, Won-Ho;Choi, Sung-Keun;Shrestha, Bhushan
    • Mycobiology
    • /
    • 제34권4호
    • /
    • pp.196-199
    • /
    • 2006
  • Effects of various preservation periods and subcultures on fruiting body formation of Cordyceps militaris were investigated using EFCC C-10995 single ascospore strains. Fruiting body formation by original strains was profuse when preserved at $4^{\circ}C$ for $5{\sim}6$ months. Fruiting from subcultures was stable till second to sixth subcultures, after which it decreased sharply. The more the colony color of subcultures changed, the less the fruiting bodies formed. Liquid inoculum preparation of single ascospore strains in the same or separate broths did not affect fruiting body formation. Similarly, two strains C-10995-3 and C-10995-6 in different numbers during liquid inoculum preparation produced similar fruiting bodies.

학교도서관의 장서관리 현황조사 및 분석 (A Survey and Analysis of Current Collection Management State in School Libraries)

  • 김성준;이병기
    • 한국도서관정보학회지
    • /
    • 제48권1호
    • /
    • pp.21-42
    • /
    • 2017
  • 이 연구는 학교도서관의 장서관리 현황을 파악하기 위해 전국의 154개교를 대상으로 설문조사를 실시하여 분석한 결과이다. 설문지는 학교도서관의 장서현황, 이용현황, 장서관리 체제의 3개 영역에 걸친 총 12개의 조사내용으로 구성되었다. 분석결과 도출된 주요 내용을 종합하면 다음과 같다. 첫째, 자료현황에서 2015년 기준 학생 1명당 단행본 수는 전문단체인 한국도서관협회기준과 비교하여 초등학교와 중학교는 기준을 초과하였으나, 고등학교는 기준에 미치지 못하였다. 입수자료의 주제별 비율은 문학이 압도적으로 높았으며, 다음 주제로 사회과학과 역사의 비율이 높게 나타났다. 둘째, 이용현황에서 학교급별 대출현황은 학생, 교사, 학부모 모두 초등학교에서 높게 나타났다. 그리고 2013년부터 2015년까지 한 번도 대출된 적이 없는 자료는 전체 장서의 64.6%로 나타났다. 셋째, 장서관리 체제에서 전체 154개교 중 114개교(74%)가 자체의 장서관리 정책서를 보유하고 있고, 이들 모든 학교는 연간 1회 이상의 장서점검 및 평가를 실시하였다. 그리고 대부분의 학교는 자체의 학교도서관운영위원회를 구성하고 있으며, 이들은 연 중 2~3회의 회의를 개최하는 것으로 나타났다. 그리고 학교도서관운영위원회는 학교도서관 현안문제에 대한 대화와 소통의 장으로, 그리고 장서개발, 운영지원, 홍보에서 중요한 역할을 수행하는 것으로 조사되었다.

원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교 (Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System)

  • 김상도;박영옥;강용
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.