• 제목/요약/키워드: Cold working

검색결과 322건 처리시간 0.028초

화학축냉용 무기염들의 수화반응 및 열 및 물질전달 향상방안 (Study of Hydration Reaction Characteristics of Inorganic Salts for Chemical Cold Storage and Method of Enhancement of Heat and Mass Transfer)

  • 김상욱;한종훈;황용준;이건홍
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.185-191
    • /
    • 1999
  • An air-conditioning system based on the chemical heat storage principle was considered. $H_2O$ was chosen as the reaction gas and the working fluid as well. Na$_2$S, CaCl$_2$, MnCl$_2$, BaCl$_2$, MgCl$_2$, Fe$_2$(SO$_4$)$_3$ and MnSO$_4$ were tested as the solid reactants by using Cahn pressure balance. Na$_2$S was superior to other salts in respect of high capability of absorption of water gas, 5 moles of $H_2O$ per unit mole of Na$_2$S, and adequate temperature of adsorption, $65^{\circ}C$ at 7torr, and of desorption, 13$0^{\circ}C$ at 76torr. Clausius-Clapeyron diagram of Na$_2$S was obtained via adsorption experiments at several vapor pressures of water gas. To enhance heat and mass transfer characteristics, usually below 1W/m K, of the reactor bed of general adsorption systems, expanded graphite block was adapted as the support of Na$_2$S salt. Expanded graphite blocks had thermal conductivity values of 20~80W/mK with respect to 100~400kg/㎥ of block bulk density. Permeability values of expanded graphite blocks were 10$^{-13}$ ~ 10$^{-14}$ $m^2$ with respect to 100~300kg/㎥ of block bulk density showing highly decreasing values of permeability, below 10$^{-l4}$$m^2$, in the range of above 150kg/㎥ of block bulk density.y.

  • PDF

30톤급 액체로켓엔진용 터보펌프 실매질시험 (Real-Propellant Test of a Turbopump for a 30-Ton Thrust Level of Liquid Rocket Engine)

  • 홍순삼;김대진;김진선;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.359-365
    • /
    • 2008
  • 30톤급 액체로켓엔진용 터보펌프에 대하여 실매질을 사용하여 성능시험이 이루어졌다. 산화제펌프와 연료펌프에는 각각 액체산소, 케로신의 실매질을 사용하고 터빈에는 고압의 상온 수소가스가 사용되었다. 터보펌프는 설계점과 탈설계점의 전 영역에서 안정적으로 작동하였고 요구되는 성능 조건을 만족시켰으며 이로써 엔진 서브시스템 수준의 터보펌프 개발이 성능 측면에서 검증되었다고 볼 수 있다. 본 논문에서는 단일 운전으로 세 운용점에서 총 75초간 작동된 경우의 시험결과를 소개하였다. 펌프와 터빈의 성능 특성 관점에서 터보펌프 조립체의 실매질 성능시험 결과와 터보펌프 구성품의 상사 성능 시험 결과가 양호하게 일치하였다.

  • PDF

가스내장 히트파이프의 냉시동특성과 성능에 관한 연구 (A Study on the Chilling Start-up Characteristics and Performance of a Gas Loaded Heat Pipe)

  • 홍성은;강환국
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.915-922
    • /
    • 2006
  • Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.

Effects of Surface Machining by a Lathe on Microstructure of Near Surface Layer and Corrosion Behavior of SA182 Grade 304 Stainless Steel in Simulated Primary Water

  • Zhang, Zhiming;Wang, Jianqiu;Han, En-hou;Ke, Wei
    • Corrosion Science and Technology
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2019
  • To find proper lathe machining parameters for SA182 Grade 304 stainless steel (SS), six kinds of samples with different machining surface states were prepared using a lathe. Surface morphologies and microstructures of near surface deformed layers on different samples were analysed. Surface morphologies and chemical composition of oxide films formed on different samples in simulated primary water with $100{\mu}g/L\;O_2$ at $310^{\circ}C$ were characterized. Results showed that surface roughness was mainly affected by lathe feed. Surface machining caused grain refinement at the top layer. A severely deformed layer with different thicknesses formed on all samples. In addition to high defect density caused by surface deformation, phase transformation, residual stress, and strain also affected the oxidation behaviour of SA182 Grade 304 SS in the test solution. Machining parameters used for # 4 (feed, 0.15 mm/r; back engagement, 2 mm; cutting speed, 114.86 m/min) and # 6 (feed,0.20 mm/r; back engagement, 1 mm; cutting speed, 73.01 m/min) samples were found to be proper for lathe machining of SA182 Grade 304 SS.

IoT 백신 냉장고를 사용한 개발도상국 백신 콜드체인 모니터링 시스템 (Vaccine Cold Chain Monitoring System Using IoT Vaccine Fridge for Developing Countries)

  • 유장현;박사무엘;류종하;왕심린;임혁순;이협승;안성훈
    • 적정기술학회지
    • /
    • 제7권1호
    • /
    • pp.26-32
    • /
    • 2021
  • 콜드체인의 마지막 단계인 백신전달 과정에서 대부분 얼음을 넣은 단열컨테이너로 온도를 조절하며, 백신의 온도 조절이 적절하지 않아 낭비되는 백신의 양이 상당하다. 예방접종을 관리하고 운영하는데 온도 데이터가 중요하며, 본 연구에서는 실시간 백신전달 모니터링 시스템을 개발하였다. 휴대용 백신 냉장고의 온도, 위치 및 전력 소비 데이터를 수집하기 위해 문자(Short Message Service) 통신 방법을 사용하였고, 한국과 탄자니아(아루샤 및 킬리만자로 지역)에서 시스템을 테스트하였다. 개발된 백신 냉장고는 문자통신을 통해 데이터 손실없이 실시간으로 백신상태를 모니터링을 할 수 있었다. 백신의 상태 및 데이터는 클라우드 서버를 통해 웹 기반 유저 인터페이스에서 확인할 수 있었다.

원전용 안전등급 밸브의 현장 폐쇄기밀시험 기술에 대한 연구 (Research on the on-site Seat Test Technology for the nuclear safety related valves)

  • 정환석;김태성
    • 한국압력기기공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.8-17
    • /
    • 2021
  • The seat leakage test is required after the maintenance work on the valve seat. Either the test has been performed outside of the plant after cutting the valve from the pipe system or the simplified test has been performed so far. It was unable to perform the test at the plant site because it is hard to make a steady pressure on the valve inlet when it is installed in the pipe. This research aims to perform the leakage test in the nuclear power plant while it is installed in the pipe system. The mock-up test is performed by pressurizing the leak-off pipe on the valve body. The result is compared with traditional test result by pressurizing the valve inlet. Furthermore the chamber mock-up tests are performed under various conditions. The leak rate by the developed test using the leak-off pipe is found to be similar but greater than the leak rate by the existing test method. It implies that the test using the leak-off pipe is more conservative than the existing test. The methodology and the equipment which this paper suggests that on-site seat test is possible and the application of the technology could reduce the time and cost for the valve maintenance work significantly.

Neutron-irradiated effect on the thermoelectric properties of Bi2Te3-based thermoelectric leg

  • Huanyu Zhao;Kai Liu;Zhiheng Xu;Yunpeng Liu;Xiaobin Tang
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.3080-3087
    • /
    • 2023
  • Thermoelectric (TE) materials working in radioisotope thermoelectric generators are irradiated by neutrons throughout its service; thus, investigating the neutron irradiation stability of TE devices is necessary. Herein, the influence of neutron irradiation with fluences of 4.56 × 1010 and 1 × 1013 n/cm2 by pulsed neutron reactor on the electrical and thermal transport properties of n-type Bi2Te2.7Se0.3 and p-type Bi0.5Sb1.5Te3 thermoelectric alloys prepared by cold-pressing and molding is investigated. After neutron irradiation, the properties of thermoelectric materials fluctuate, which is related to the material type and irradiation fluence. Different from p-type thermoelectric materials, neutron irradiation has a positive effect on n-type Bi2Te2.7Se0.3 materials. This result might be due to the increase of carrier mobility and the optimization of electrical conductivity. Afterward, the effects of p-type and n-type TE devices with different treatments on the output performance of TE devices are further discussed. The positive and negative effects caused by irradiation can cancel each other to a certain extent. For TE devices paired with p-type Bi0.5Sb1.5Te3 and n-type Bi2Te2.7Se0.3 thermoelectric legs, the generated power and conversion efficiency are stable after neutron irradiation.

이온 주입한 강의 미시적 마모 튼성의 평가 (Development of methodology for evaluating tribological properities of Ion-implanted steel)

  • 문봉호;최병영
    • 한국정밀공학회지
    • /
    • 제14권9호
    • /
    • pp.146-154
    • /
    • 1997
  • Ion implantation has been used successfully as a surface treatment technology to improve the wear. fatigue and corrosion resistances of materials. A modified surface layer by ion implantation is very thin(under 1 m), but it has different mechanical properties from the substrate. It has also different wear characteristics. Since wear is a dynamic phenomenon on interacting surfaces with relative motion, an effective method for investigtating the wear of a thin layer is the observation of wear process in microscopic detail using in-situ system. The change of wear properties produces the transition of wear mode. To know the microscopic wear mechanism of this thin layer, it is very important to clarify its microscopic wear mode. In this paper, using the SEM and AFM Rribosystems as in-situ system, the microscopic wear of Ti ion-implanted 1C-3Cr steel, a material for roller in the cold working process, was investigated in repeated sliding. The depth of wear groove and the speciffc wear amount were changed with transition of microscopic wear mode. The depth of wear groove with friction cycles in AFM tribosystem and specific wear amount of Ti ion-implanted 1C-3Cr steel were less about 2-3 times than those of non-implanted 1C-3Cr steel. The microscopic wear mechansim of Ti ion-implanted 1C-3Cr steel was also clarified. The microscopic wear property was quantitatively evaluated in terms of microscopic wear mode and specific wear amount.

  • PDF

대류식 순환장치의 저수지수체 유동특성 및 수질영향 (Study on Effect of Convection Current Aeration System on Mixing Characteristics and Water Quality of Reservoir)

  • 이요상;이광만;고덕구;염경택
    • 생태와환경
    • /
    • 제42권1호
    • /
    • pp.85-94
    • /
    • 2009
  • 용담댐 저수지에 설치된 대류식 순환장치에 대한 현장 조사 결과에 의하면 수평방향의 직접영향권은 성층 강도에 큰 영향 없이 반지름 $7{\sim}10m$에 이르는 것으로 조사 되었으며 수직방향으로는 성층강도에 따라 또는 가동기간에 따라 조금씩 달라지는 것으로 나타났다. 즉 가동시간이 길어짐에 따라 하층에서 올라온 수온이 낮은 수체는 보다 깊게 먼 곳까지 이동하는 것으로 나타났으나 성층을 깨지는 못하는 것으로 나타났다. 2008년 현장에서 실측 조사한 결과와 CFD모사 결과에 의하면 이런 조건에서 한 달을 가동하면 하층에서 올라온 수체가 대류식 장치 주변으로 수심 8 m, 지름 120 m의 수층을 이루게 되며 50일을 가동하면 수심 10 m, 지름 130m의 수층을 이루는 것으로 평가되었다. 대류식 순환장치가 설치된 지역에 대한 CFD모사를 하기 전에 이 지역의 흐름특성을 평가하였다. 대상 지역의 흐름은 연중 크게 3가지로 구분되었으며 각각의 경우 유량은 다르지만 저수지 수체의 흐름 속도는 모두 $0.05{\sim}1.5cm\;sec^{-1}$로 나타나 CFD모사시에 저수지 흐름을 고려하지 않아도 될 것으로 평가되었다. CFD를 이용한 수체거동 모사결과 순환장치로부터 3m지점에서의 유속은 $0.25m\;sec^{-1}$를 나타냈고, 5m지점에서는 $0.2m\;sec^{-1}$를 나타냈다. 현장 실측 결과와 비교시 유속은 모사 결과가 조금 크게 산정되는 것으로 나타났으나 향후 보다 많은 자료를 확보하여 비교해 보아야 할 것으로 판단되었다. 반면 영향범위는 반경방향으로 10 m지점까지는 직접영향을 받고, 그 보다 먼 지점은 간접영향권임을 나타내고 있어 이는 모사결과와 실측치 간에 일치하는 것으로 나타났다. 수면에서의 온도분포는 순환장치로부터 분출된 저온의 물이 반지름 약 10 m지점까지는 수온변화에 영향을 미치는 직접영향권인 것을 알 수 있다. 이상과 같이 모사 결과는 현장에서 실측한 것과 유사한 결과를 나타내므로 결과의 신뢰성이 높은 것으로 판단되었다.

Effects of Tropical Climate on Reproduction of Cross- and Purebred Friesian Cattle in Northern Thailand

  • Pongpiachan, P.;Rodtian, P.;Ota, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권7호
    • /
    • pp.952-961
    • /
    • 2003
  • In the first part of the study, rates of estrus occurrence and success of A.I. service in the Thai-native and Friesian crossbred, and purebred Friesian cows fed in the National Dairy Training and Applied Research Institute in Chiang Mai, Thailand were traced monthly throughout a year. An electric fan and a water sprinkler cooled the stall for the purebred cows during the hot season (March-September). Both rates in pure Friesians were at their highest in the cold-dry season (October- February), but they decreased steadily during the hot-dry season (March-May) and were at their lowest in the hot-wet season (June-September). Seasonal change of a similar pattern was observed in the incidence of estrus, but not in the success rate of insemination in the crossbred cows. By the use of reproductive data, compiled in the same institute, on the 75 % cross- and purebred Friesian cows, and climatological data in Chiang Mai district, effects of ambient temperature and humidity on the reproductive traits of cows were examined by regression analysis in the second half of the study. Significant relationships in the crossbred, expressed by positive-linear and parabola regressions, were found between reproductive parameters such as days to the first estrus (DTFE), A.I. service (DTFAI), and conception, the number of A.I. services required for conception and some climatic factors. However, regarding this, no consistent or intelligible results were obtained in purebred cows, perhaps because electric fans and water sprinklers were used for this breed in the hot season. Among climatic factors examined, the minimum temperature (MINT) in early lactation affected reproductive activity most conspicuously. As the temperature during one or two months prior to the first estrus and A.I. service rose, DTFE and DTFAI steadily became longer, although, when MINT depleted below $17-18^{\circ}C$, the reproductive interval tended to be prolonged again on some occasions. The maximum temperature also affected DTFE and DTFAI, but only in limited conditions. The effect of humidity was not clear, although the inverse relationship between DTFE and minimum humidity during 2 months before the first estrus in the crossbred seemed to be significant. Failure to detect any definite effect of climate on the reproductive traits of pure Friesians seemed to indicate that forced ventilation by electric fans and water sprinklers were effective enough to protect the reproductive ability of this breed from the adverse effects of a hot climate.