• 제목/요약/키워드: Cold storage system

검색결과 206건 처리시간 0.029초

수중 빙 제조방식을 적용한 빙축열시스템의 축방냉 특성 실험 (Experiment of Characteristic on the Charge and Discharge of Cold in Ice Storage System Applied Ice Making Method In-Water)

  • 최인수;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.31-37
    • /
    • 2002
  • This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks. The results showed discharge of cold capacity of new type indicated the high values about 30~40% based on five time of drive, the temperature difference of inlet/outlet occurred the big range about $1.3^{\circ}C$. So, the new type which makes ice in water showed superiorly.

직접 접촉식을 이용한 빙축열 시스템 (Cold Energy Storage System Using Direct Contact Heat Transfer)

  • 이윤표;윤성영;이춘식
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.247-258
    • /
    • 1994
  • In this study, experimental investigations to find cold energy storage performance have been made for two different temperatures at condenser. Temperatures at inlet and outlet of condenser were measured to calculate global heat transfer coefficient of direct contact method in our cold energy storage system. Also storage performance by direct contact method was compared with that of Ice-On-Coil type ice storage which was calculated by analytic solution. Results show that, in the case of $-8.0^{\circ}C$ at condenser inlet, heat transfer coefficient of direct contact method is 3.25 times higher than that of conventional method and COP of system is improved by using R141b as refrigerant which produces gas hydrate and has higher phase change temperature than $0.0^{\circ}C$.

  • PDF

저온냉장장치용 온도제어기의 원격 모니터링 시스템 개발 (Development of Remote Monitoring System of Temperature Controller for Cold-Storage)

  • 임대영;유영재;장영학;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2486-2488
    • /
    • 2003
  • This paper describes a remote monitoring system of temperature controller for cold-storage, of farm produce. In the cold-storage, it is important that farm produces are fresh. Unfortunately, when an operator goes out from the cold-storage temperature change could be occurred due to the various reasons, for an example, a valve of cooler is broken. The temperature change results in a serious problem of the quality of farm produce. To prevent the problem, the operator has to look to the current state of the temperature of the cold-storage, even he is in long away. Thus, the monitoring system to show the temperature should be required to the operator who can move away. Therefore, this paper propose of the remote monitoring system of the temperature. The proposed system is expected to help the operator's facilities, and the management of farm produce.

  • PDF

하베스트형 빙축열시스템의 축열조 특성 (Characteristics of Storage Tank on Harvest Type Ice Storage System)

  • 최인수;이호생;문춘근;김재돌;윤정인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.210-215
    • /
    • 2000
  • A fundamental study on the under water harvest-type ice storage system and its temperature characteristics in ice storage system was performed experimentally. The experiments were conducted by changing the inlet refrigerant temperature of an evaporator to analyzing the thermal fluid motion inside the ice storage tank. From the experimental results, the cold storage characteristics were investigated by measuring the axial and radial temperature variations inside the ice storage tank with respect to the inlet and outlet refrigerant temperatures of an evaporator. In case of the under water harvest-type ice storage system, thermal fluid motion inside the ice storage tank was shown differently in comparison with that of other ice storage systems. During the cooling storage process, there was no supercooling phenomenon in the ice storage tank. These results show the characteristic of this system and the possibility of application to other fields.

  • PDF

빙축열시스템의 실질적인 최대 축열 가능량 예측 (Prediction of practically chargeable cold energy in an ice storage system)

  • 이대영;강병하;김민수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

ICT 콜드체인 기술이 적용된 무인 택배물품 보관장치의 시스템 운영 안전성 확보를 위한 연구 (The Development of the System Operation Safety of Unmanned Parcel Storage System with ICT and Cold Chain Technology)

  • 박재민;김영민
    • 대한안전경영과학회지
    • /
    • 제24권3호
    • /
    • pp.29-37
    • /
    • 2022
  • The development of technology related to the Fourth Industrial Revolution and the growth of the online market due to pandemic are continuing the growth of the logistics market for product delivery. If it is difficult to deliver the product directly to the customer during delivery, storage and delivery using the unmanned courier box are being carried out. However, existing storage boxes are not actively used due to lack of usability even though they have the advantage of storing goods and delivering non-face-to-face. In addition, existing courier boxes are not prepared for cold chain transportation. The unmanned delivery storage device with ICT cold chain technology should be developed to prepare for the transition to non-face-to-face society, to improve logistics efficiency and meet user's requirements. Also, it is necessary to consider the measures to reduce the safety problems that may occur during the use and maintenance of the automatic system. This study conducted a model-based analysis for the development of unmanned delivery storage devices with ICT cold chain technology, and conducted a study to derive the system development specifications that meet the requirements and secure safety and apply them to the development process.

수중 빙제조형 빙축열시스템의 성능특성 특성 (Experimental Study on the Performance Characteristic in Underwater Harvest-Type Ice Storage System)

  • 장용식;이호생;최인수;김재돌;김은필;윤정인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.298-303
    • /
    • 2001
  • A fundamental study on the under water harvest-type ice storage system and its temperature characteristics in ice storage system was performed experimentally. The experiments were conducted by changing the inlet refrigerant temperature of an evaporator to analyzing the thermal fluid motion inside the ice storage tank. From the experimental results, the cold storage characteristics were investigated by measuring the axial and radial temperature variations inside the ice storage tank with respect to the inlet and outlet refrigerant temperatures of an evaporator. In case of the under water harvest-type ice storage system, thermal fluid. motion inside the ice storage tank was shown differently in comparison with that of other ice storage systems. During the cooling storage process, there was no supercooling phenomenon in the ice storage tank. These results show the characteristic of this system and the possibility of application to other fields.

  • PDF

RFID 기반 냉동창고 시스템의 적재위치 관리 방안 (An Approach for Managing Storage Locations in RFID-Based Cold-Storage Warehouse System)

  • 문미경;최봉준
    • 한국정보통신학회논문지
    • /
    • 제15권9호
    • /
    • pp.1971-1978
    • /
    • 2011
  • 기존의 RFID (Radio Frequency Identification) 기반 냉동창고 시스템에서는 cold room 입구에 RFID 리더기를 설치하여 물품이 인식될 때 단지 그곳에 적재되는 것으로 인식하였다. 그러나 이러한 방법으로는 다양한 상황에서 물품의 적재위치 인식에 오류가 발생하게 된다. 냉동창고에서는 물품 보관을 하는 cold room의 안팎 온도차이로 인해 물품의 적재위치 오류는 물품의 변질을 가져오게 하므로 실시간 정확한 위치를 파악하는 것은 매우 중요하다. 본 논문에서는 2대의 RFID 리더기가 설치된 지게차와 천정태그를 이용하여 냉동창고 관리시스템에서 물품의 적재위치 오류를 해결하기 위한 방안을 제시한다. 지게차에 설치된 2개의 RFID 리더기는 각각 천장에 부착된 태그로부터 위치데이터와 지게차에 적재된 물품데이터를 획득한다. 2개의 리더기로부터 수집된 데이터를 분석하여 물품의 입/출고 상황정보와 물품의 이동경로정보를 실시간으로 모니터링 할 수 있다. 이를 통해 냉동창고의 물품보관에 대한 효율성을 높일 수 있게 한다.

과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구 (Experimental Study on The Running Characteristics of Showcase Using Cold Storage System)

  • 이동원;김정배
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.

최적화된 비즈니스 프로세스를 위한 RFID 배치 시뮬레이터 기반의 냉동창고 관리 시스템 (Cold Storage Management System using RFID Deployment Simulator for Optimized Business Process)

  • 백선제;문미경
    • 한국정보통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1453-1459
    • /
    • 2010
  • 최근 들어 단순 보관의 기능만을 가지고 있던 기존의 냉동창고가 보관뿐만 아니라, 규격화된 유통 시스템을 갖추어 전체 물류 공급망 관리의 효율성과 경쟁력을 갖추고자 한다. 이를 위해 라디오 주파수를 이용하여 움직이는 물체를 인식, 추적, 분류할 수 있는 기술인 RFID (Radio Frequency Identification)를 적용할 수 있다. 본 논문에서는 RFID 기술을 적용하여 최적화된 비즈니스 프로세스를 지원하는 냉동창고 관리 시스템을 개발하고자 한다. 이를 위해 냉동창고 업무 프로세스를 분석하고 RFID 기술 도입에 따른 의사결정이 필요한 설계요소들을 식별한다. 식별된 설계요소들은 RFID 배치 시뮬레이터를 이용하여 RFID 데이터가 비즈니스 프로세스에 통합되는 과정에 대하여 그 효율성을 판단할 수 있게 한다.