Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles (축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

Enhancement of the round-trip efficiency of liquid air energy storage (LAES) system using cascade cold storage units

  • Kim, Jhongkwon;Byeon, Byeongchang;Kim, Kyoung Joong;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.45-50
    • /
    • 2020
  • In this research, the variation of round-trip efficiency in a liquid air energy storage system (LAES) is calculated and an optimal configuration is found. The multiple stages of cold energy storage are simulated with several materials that process latent heat at different temperature ranges. The effectiveness in the charging and discharging processes of LAES is newly defined, and its relationship with the round-trip efficiency is examined. According to defined correlation, the effectiveness of the discharging process significantly affects the overall system performance. The round-trip efficiency is calculated for the combined cold energy storage materials of aqueous dimethyl sulfoxide (DMSO) solution, ethanol, and pentane theoretically. The performance of LAES varies depending on the freezing point of the cold storage materials. In particular, when the LAES uses several cold storage materials, those materials whose freezing points are close to room temperature and liquid air temperature should be included in the cold storage materials. In this paper, it is assumed that only latent heat is used for cold energy storage, but for more realistic analyzes, the additional consideration of the transient thermal situation to utilize sensible heat is required. In the case of such a dynamic system, since there is certainly more increased heat capacity of the entire storage system, the volume of the cold energy storage system will be greatly reduced.

Study on the Change of Lipid Peroxides Amount While Beef Bulgogi Cocking (우육(牛肉)의 불고기 조리시 과산화지질의 변화에 관한 연구)

  • Shin, Duk-Kue
    • Journal of the Korean Applied Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.75-87
    • /
    • 1989
  • Study to report this result that state of lipid peroxides while beef Bulgogi Coocking of general-seasoning, sale-seasoning, each flavour's characteries. Raw meat show high lipid peroxides amount and high increasing in heat and antioxidative effected by flavour about lipid peroxidies change existence by beef Bulgogi seasoning. Change of lipid peroxides are significant increased in meat cold storage and cold storage and cold storage heat meat after while 30 minute after seasoned and reduced 9 hour - 33 hour cold storage raw meat, that change of lipid peroxides by cooking time. every condition by adding soften were revealed lipid peroxides, reduce. Lipid peroxide change are very high while no-sugar in raw meat and not a stone look in 9-hour raw-meat after seasone about antioxidative effect by each flavour characteristic TBA showed very high not take parched seasone seeds item about 30-minute cold storage beat raw-meat and high lipid peroxides revealed increase in not take wine item, not take a pear item, in 9 hour cold storage heat-meal and it showed little amount not-sugar item, no opepper item. According to high lipid peroxides change reduced high after seasoned cold storage stage in Korea traditional Bulgogi Cooking and thought high that action of antioxidative lipid peroxides wine and a pear in flavour.

Feasibility Study of Cold Storage System to Maintaining Cooling Performance for ISG Vehicle (공회전 제한장치 차량에서 냉방 성능 유지를 위한 축냉 시스템 적용에 대한 연구)

  • Lee, Daewoong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • This study explores the feasibility of a cold storage system to provide thermal comfort for idle stop and go (ISG) vehicles. ISG function is the most valuable and environmental friendly technology in the current automobile industry. However, when an ISG vehicle stops, meaning when the engine standstill, the air-conditioning system does not work, because the compressor also stops. Therefore, passenger thermal comfort is not maintained, as cold air is not provided in the cabin. Consequently, many automakers have studied electric air-conditioning systems based on electrically-driven compressors or cold storage systems using phase-change materials. The experiments herein were conducted for the feasibility testing of different types of cold storage heat-exchangers, cold storage mediums, and thermo-expansion valves with current air-conditioners. The auxiliary cold storage system, filled with phase-change materials, was located behind the evaporator and almost stacked on top of it. In the experimental results, the air discharge temperature rate of increase was better than the conventional air-conditioning system when the compressor stopped and thermal comfort was maintained with $1.9{\sim}4.3^{\circ}C$ decreases within 60 seconds. The #1 cold storage heat-exchanger (CSH), #2 thermo-expansion valve (TXV) and #2 phase change material (PCM) were chosen because of the best temperature rise delay. It was concluded that a cold storage system is an effective solution for ISG vehicles to maintain thermal comfort during short engine stops.

Cold Energy Storage System Using Direct Contact Heat Transfer (직접 접촉식을 이용한 빙축열 시스템)

  • Lee, Y.P.;Yoon, S.Y.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.247-258
    • /
    • 1994
  • In this study, experimental investigations to find cold energy storage performance have been made for two different temperatures at condenser. Temperatures at inlet and outlet of condenser were measured to calculate global heat transfer coefficient of direct contact method in our cold energy storage system. Also storage performance by direct contact method was compared with that of Ice-On-Coil type ice storage which was calculated by analytic solution. Results show that, in the case of $-8.0^{\circ}C$ at condenser inlet, heat transfer coefficient of direct contact method is 3.25 times higher than that of conventional method and COP of system is improved by using R141b as refrigerant which produces gas hydrate and has higher phase change temperature than $0.0^{\circ}C$.

  • PDF

A study on cooling characteristics of clathrate compound for cold storage applications (저온축열용 포접화합물에 냉각특성에 관한 실험적 연구)

  • 한영옥;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

An Experimental Study on Thermal Properties of Clathrate for Cold Storage Applications (저온축열용 포접화합물의 열물성에 관한 실험적 연구)

  • 한영옥;정낙규;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.725-734
    • /
    • 2000
  • The objective of this paper is to investigate the thermal properties of TMA clathrate applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are peformed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of concentrations and temperature of heat source in TMA clathrate. The results are summarized as follows; 1) temperature of phase change is dropped as the temperature of heat source is lower, 2) the effect of subcooling suppression with about $9.3^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 29wt% and 30wt% . Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$ Thus, it is concluded that TMA clathrate has proper properties as the cold storage medium for building air-conditioning.

  • PDF

The Study on Cooling Characterics of TMA Clathrate with Ethanol (에탄올을 첨가한 TMA 포접화합물의 냉각특성에 대한 연구)

  • 김창오;김진흥;정낙규;김석현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.634-640
    • /
    • 2002
  • The purpose of this study is to investigate the propriety of TMA clathrate as a cold storage medium. Particularly, this is to examine the extent of subcooling improvement when the additives is added to the TMA clathrate, because water used for cold storage ma terial has low phase change temperature and subcooling. This study has been analyzed and compared pure water with TMA 30 wt% clathrate how phase change temperature, subcooling and specific heat in the various concentrations are changed. This results prove low phase change temperature and subcooling control effect when the ethanol is added to the TMA 30 wt% clathrate than the TMA 30 wt% clathrate. In addition, it results low specific heat when there is added to the TMA 30 wt% clathrate over 0.5 wt% ethanol in the cold heat source temperature under $-7^{\circ}C$. The other side, it results high specific heat when the ethanol is added in it at the cold heat source temperature under $-5^{\circ}C$. Therefore, it is found that the additive must be controlled by available solution limit and study for new additive must be lasted to know its effect.

Numerical Analysis of Cold Storage System with Array of Solid-Liquid Phase Change Module (저온의 고-액상변화 모듈 용기의 배열에 따른 축냉시스템의 수치해석)

  • Mun, Soo-Beom
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.5
    • /
    • pp.577-582
    • /
    • 2015
  • This paper is the fundamental study for the application of cold storage system to the transportation equipment by sea and land. This numerical study presents the solid-liquid phase change phenomenon of calcium chloride solution of 30wt %. The governing equations are 1-dimensional unsteady state heat transfer equations of $1^{st}$ order partial differential equations. This type of latent heat storage material is often usable in fishery vessel for controlling the temperature of container with constant condition. The governing equation was discretized with finite difference method and the program was composed with Mathcad program. The main parameters of this solution were the initial temperature of heat storage material, ambient temperature of cold air and the velocity of cold air. The data of boundary layer thickness becomes thin with the increasing of cold air flowing velocity and also the heat storage completion time become shorten.