• Title/Summary/Keyword: Cold function test

Search Result 64, Processing Time 0.025 seconds

A study on the Effectivness of Hand-made Paraffin Thyroid Phantom (Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구)

  • Park, Soung-Ock;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.237-243
    • /
    • 2007
  • Phantoms are very necessary for quality assurance of radio nuclides imaging systems to maintain standards and to ensure reproducibility of test. General quality assurance and instrument quality control are essential in every hospital. The human tissue equivalent materials are aluminum, areryl, water and epoxy..etc. It is very important to select optimum equivalant materials for a phantoms in QC. Especially, paraffin is very similar with human soft tissue in X or Gamma-ray physical characteristics and easy to buy with economically. We made a paraffin thyroid phantom and compare with thyroid areryl phantom, also used commercially in practice. Two small size cold spots(3 and 6 mm diameter) and a hot spot(3 mm diameter) embeded in paraffin phantom. And imaged with $^{99m}TcO_4$ by camera for analysis about spatial resolution and noise at the hot and cold spots. We got some results as below : 1. No difference in counting rate and noise between both arcryl and paraffin thyroid phantoms. 2. The best spatial resolution can be seen 6 cm distance between pinhole collimator and thyroid phantoms(arcryl and paraffin). 3. More optimal spatial resolution could acquired in paraffin thyroid phantom. Paraffin is very similar with human soft tissue in atomic number, density and relative absorbtion function, and can be shaped easily what we wanted. So we can recommendation paraffin as quality assurance phantom because its usefulness, economical benefit and purchasability.

  • PDF

A Numerical Study on the Pressure Drop and Heat Transfer in the Hot Channel of Plate heat Exchanger with Chevron Shape (쉐브론 형상 판형 열교환기의 고온 채널에서의 압력손실 및 열전달 특성에 관한 해석 연구)

  • Sohn, Sangho;Shin, Jeong-Heon;Kim, Jungchul;Yoon, Seok Ho;Lee, Kong Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.175-185
    • /
    • 2018
  • This research investigates the internal flow and heat transfer in a plate heat exchanger with chevron shape by utilizing the computational fluid dynamics (CFD) software. The basic unit of the plate heat exchanger is generally composed of a hot channel, an intermediate chevron plate, and a cold channel. Several studies have reported experimental and numerical simulation of heat transfer and pressure drop. This study focused on the detailed numerical simulation of flow and heat transfer in the complicated chevron shape channel. The long chevron plate was designed to include 16 chevron patterns. For proper mesh resolution, the number of cells was determined after the grid sensitivity test. The working fluid is water, and its properties are defined as a function of temperature. The Reynolds number ranges from 900 to 9,000 in the simulation. A realizable $k-{\varepsilon}$ model and non-equilibrium wall function are properly considered for the turbulent flow. The friction factors and heat transfer coefficient are validated by comparing them with existing empirical correlations, and other patterned flow phenomena are also investigated.

Developing a Multi-Functional Smart Down Jacket Utilizing Solar Light and Evaluating the Thermal Properties of the Prototype (태양광을 활용한 스마트 다운재킷 개발 및 보온성능 평가)

  • Yi, Kyonghwa;Kim, Keumwha
    • Journal of Fashion Business
    • /
    • v.19 no.4
    • /
    • pp.92-108
    • /
    • 2015
  • This study aimed at developing a down jacket prototype that utilized sunlight as an alternative energy source with no air pollution. The jacket is filled with flexible solar panels and has a heat-generating function and LED function. In this study, three smart down jacket prototypes were developed, and the jacket's capabilities were demonstrated through the thermal effect on the performance test. The typical output voltage of the flexible solar panels was 6.4V. By connecting the 2 solar cell modules in series, the final output voltage was 12.8V. A battery charge regulator module was used the KA 7809 (TO-220) of 9V. Three heating pads were to be inserted into the belly of the jacket as direct thermal heating elements, and the LED module was configured, separated by a flash and an indicator. The smart down jacket was designed to prevent damage to the down pack without the individual devices' interfering with the human body's motion. Because this study provides insulation from extreme cold with a purpose, the jacket was tested for heat insulation properties of non-heating, heating on the back, heating on the abdomen, and heating on both the back and abdomen in a sitting posture in a static state. Thermal property analysis results from examining the average skin temperature, core temperature, and the temperature and humidity within clothing showed, that placing a heating element in one place was more effective than distributing the heating elements in different locations. Heating on the back was the most effective for maintaining optimal skin temperature, core temperature, and humidity, whereas heating on the abdomen was not effective for maintaining optimal skin temperature, core temperature, or humidity within clothing because of the gap between the jacket and the body.

Thermal Design of MGSE Panel for Thermal Vacuum Test of Ka-band Engineering Qualification Model Payload of Communications and Broadcasting Satellite (통신방송위성 Ka-대역 기술인증모델 탑재체의 열진공시험을 위한 MGSE 패널 열설계)

  • Kim, Jeong Hun;Choe, Seong Bong;Yang, Gun Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2003
  • The thermal design of MGSE(Mechanical Ground Support Equipment) panel is performed for thermal vacum thest of Ka-band EQM(Engineering Qualification Model) payload of communications and broadcasting satellite. The thermal environments are predicted to evaluate the performance of transponder equipments in the thermal vacum chamber. SINDA is used to verify the thermal design of the heat pipe layout. Embedded 16 heat pipes in the EQM payload developed for Ka-band trasponder equipments are designded properly. The heat fluz loaded on the external facesheet is 265W/㎡ for the hot platear function test of the traspinder equipments, and the zero heat flux for the cold plateau case. The maxium predicted heat transport capability is 2723 W-cm.

An Analysis on Nursing Activity in Oriental Hospital (한방근무 간호사의 업무분석)

  • Kang, Hyun Sook;Cho, Kyoul Ja;Kim, Kwang Joo;Kim, Kwuy Bun;Cho, Mi Young;Suh, Yeon Ok;Shin, Hye Sook;Jeon, Eun Young;Chung, Sook Ja;Lee, Hei Jin
    • The Korean Nurse
    • /
    • v.33 no.5
    • /
    • pp.63-75
    • /
    • 1995
  • The need of oriental nursing role is recently increasing. The implication of this trend is enormous not only for the need of independent of independent oriental nursing intervention. Hence, this study was designed to describe the characteristics of oriental nursing activity and identify the meaning of nursing activity in oriental hospital. A total of 24 nurses were selected by convenience sampling from eight units at one oriental hospital. A total of 168 data were collected using minute-by-minute recording during nurse s work shift. The data were analyzed using nova and scheffe method as post-hoc test The results of this study are as follows; 1. the category of nursing activity in oriental hospital 74.4% of nursing activity was the patient-oriented nursing care. The nursing activity included others (18.28%), the function-oriented nursing care (7.07%), and staff-oriented care (0.2%). 29.1 % of the patient-oriented nursing care was the direct care, and 24. 5 % of the patient-oriented nursing care was the indirect care. There was a lack of patient education and the communication patient. 2. Nursing activity in oriental hospital by characteristics 1) Nursing activity by unit For patient-oriented nursing care, there was a statistically significant difference among 8 units. In the critical care unit, the patient-oriented nursing care was mostly performed. For function-oriented nursing care, there was statistically significant difference among 8 units. In the physical therapy unit, the function-oriented nursing care was mostly performed. 2) Nursing activity in oriental hospital For all kinds of nursing activity, there was a statistically significant difference between shifts. In night shift patient-oriented nursing care, function-oriented nursing care, and other kinds of nursing care was mostly performed. Patient-oriented nursing care included indirect care, treatment set management, and the breaktime. In day shift, staff-oriented nursing care was performed. 3) Nursing activity in oriental hospital For all kinds of nursing activity, there was not a statistically significant difference by day. The day has not impact on nursing activity. 3. the meaning of activity in oriental hospital The results of this study show that the patient-oriented care was vital check, input! output check, medication, bedsore prevention, nasogastric feeding, oral care, catheterization care, perinatal care, nursing care associated with acupuncture and moxacautery, observation (fever, sweating), heat and cold application communication with patent and family, and patient room management In conclusion, two issues associated with the findings of the research appeated to be involved in the difficulty of nursing activity in hospital. The first issue was the nursing care in oriental hospital provided by nurses who have a limited understading of the principles of oriental medicine. The second issue was the deficiency of systematic guideling for oriental nursing activity. The findings suggest the need to develop the systematic guideline for oriental nursing activity. The need of continuing education for nurses who work in the oriental hospital, and the need of nursing education including oriental nursing are critical.

  • PDF

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

Quantitative Sensory Test: Normal Range in Korean Adults and Application to Diabetic Polyneuropathy (정량적 감각 검사: 한국인에서의 연령별 정상 범위 및 당뇨병성 다발신경병증에서의 유용성 평가)

  • Kim, Su-Hyun;Kim, Sung-Min;Ahn, Suk-Won;Hong, Yoon-Ho;Park, Kyung-Seok;Sung, Jung-Joon;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2010
  • Background: Although quantitative sensory test (QST) is being used with increasing frequency for measuring sensory thresholds in clinical practice and epidemiologic studies, there has been no age-matched normative data in Korean adults. The objective of this study is to evaluate the value of QST in diabetic polyneuropathy with normal range in Korean adults. Methods: The Computer Aided Sensory Examination IV 4,2 (WR Medical Electronics Co., Stillwater, Minnesota, U.S.A.), with 4,2,1 stepping algorithm was used to determine vibration and cold perception threshold in 70 normal controls and 19 patients with diabetic polyneuropathy aged from 21 to 79 years. The data were used to define age-matched upper and lower normal limits and normal range of side to side difference. We also evaluated the duration of diabetes, serum HbA1C level, and findings of nerve conduction study (NCS) and QST in patients with diabetic polyneuropathy. Results: In normal adults, sensory thresholds slightly increased with age, and a slight side-to-side difference was observed. The diagnostic sensitivity of QST was not higher than NCS in patients with diabetic polyneuropathy (36.8% vs. 42.1%, p=0.716), especially among elderly patients. Conclusions: QST might be used as a complementary test for NCS in the diagnosis of diabetic polyneuropathy. Although the QST is a simple method for the evaluation of peripheral nerve function, there are some limitations. Most of all, because the QST measuring is dependent on the subjective response of patients, the degree of concentration and cooperation of the patients can significantly affect the result. And thus, attention should be paid during the interpretation of QST results in patients with peripheral neuropathy.

The Influence of W Addition on Cube Textured Ni Substrates for YBCO Coated Conductor (양축 정렬된 Ni 기판의 특성에 미치는 W 첨가의 효과)

  • Kim Kyu Tae;Lim Jun Hyung;Kim Jung Ho;Jang Seok Hern;Kim Ho-Jin;Joo Jinho;Kim Chan-Joong;Song Kyu Jung;Shin Hyung Sub
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.64-68
    • /
    • 2004
  • We fabricated cube-textured Ni and Ni-W alloy substrates for coated conductors and characterized the effects of W addition on microstructure, mechanical strength, and magnetic properties of the substrate. Pure Ni and Ni-(2, 3, 5at.%)W alloys were prepared by plasma arc melting, heavily cold rolled and then annealed at various temperatures of $600-1300^{\circ}C$. The texture was evaluated by pole-figure and orientation distribution function (ODF) analysis. Mechanical properties were investigated by micro Vickers hardness and tension test. Ferromagnetism of the substrate was measured by physical property measurement system (PPMS). It was observed that Ni-W substrates had sharp cube texture, and the full-width at half-maximums (FWHMs) of in-plane texture was $^{\circ}$-5.57$4.42^{\circ}$, which is better than that of pure Ni substrate. In addition cube texture of Ni-W substrates was retained at higher temperature up to $1300^{\circ}C$. Microstructural observation showed that the Ni-W substrates had fine grain size and higher mechanical properties than the pure Ni substrate. These improvements are probably due to strengthening mechanisms such as solid solution hardening and/or grain size strengthening. PPMS analysis showed that addition of W effectively reduced saturation magnetization in applied magnetic field and Curie temperature.

  • PDF

Comparative Study of Non-Smoke Group and Smoke Group by Diagnosis System of Oriental Medicine (흡연군과 비흡연군의 폐활량과 한방변증 비교분석)

  • Park, Sung-Jun;Kim, Jin-Young;Shin, Woo-Jin;Park, Dong-Il
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.505-511
    • /
    • 2009
  • The purpose of this study is to evaluate the difference about pathogenesis of smoker and non-smoker. Author used DSOM to investigate oriental pathogenesis. Smoke group is consisted of people who have history of smoke, and they don't have history of lung disease(Athma, tuberculosis, COPD, suchlike). Non-smoke group is consisted of people who have no history of smoke and they also don't have history of lung disease. Author carried out each group's PFT(Pulmonary Function Test) by AST(American Thoracic Society) method. DSOM was used for pathogenesis investigation of two groups. There was significant difference between smoke group and non-smoke group in FVC (p<0.05), and In non-smoke group, there was significant difference between male and famale in FVC, FVC%, FEV1, FEV1%. There was significant difference between smoke group and non-smoke group in Heat(熱), Cold(寒)(p<0.05). In Male grouop there was significant difference between smoker and non-smoker in deficiency of Deficiency of Yin(陰虛), Heat(熱). In non-smoke group comparison of sex, there was significant difference between male and female in Deficiency of blood(血虛), dampness(濕)(p<0.05). This result showed that the difference of pathogenesis between smoke group and non-smoke group.

Evaluation of Plastic Anisotropy in the Steel Sheets Using EMAT (EMAT를 이용한 판재의 소성이방성 평가)

  • Ahn, B.Y.;Kim, Y.G.;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.4
    • /
    • pp.270-277
    • /
    • 1997
  • Plastic anisotropy is one of important factors which determine the drawability of a steel sheet. It has been mainly measured by mechanical tensile test. From the ultrasonic velocities propagating along the relative directions to the rolling direction, CODF(crystallite orientation distribution function) can be measured and ODC's(orientation distribution coefficients) has some correlations with the plastic anisotropy. In this study the correlations between the plastic anisotropy and ODC's of the cold rolled steel sheet were measured. From the results of ultrasonic velocity measurements the average normal anisotropy, $\bar{\gamma}$ and the average planar anisotropy, ${\Delta}r$ could be predicted within the accuracy of ${\pm}0.082$ and ${\pm}0.096$, respectively. Acoustic resonance method was applied to measure the ultrasonic velocities and EMAT's were used for generating and detecting the ultrasonic waves.

  • PDF