• Title/Summary/Keyword: Cold flow model

Search Result 239, Processing Time 0.025 seconds

Unsteady Thermal Stratified Flow and Heat Transfer in a Horizontal Feedwater Pipe (수평급수배관 내에서의 비정상 열성층유동 및 열전달)

  • Yeom, Hak-Gi;Park, Man-Heung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.680-688
    • /
    • 1996
  • In this paper, the unsteady state calculational model is proposed for the thermal stratification analysis in the feedwater line of the PWR plant. By defining dimensionless parameters in the two-dimensional polar coordinate system and applying SIMPLE algorithm, the temperature and flow profiles due to the thermal stratification are obtained. Base on the fact that the most significant condition occurs when the fluid temperature difference between the piping ends reaches as high as 166.deg. C, the present result shows that max. Dimensionless temperature difference of 0.6 (about l00.deg. C) obtained between hot and cold sections of pipe wall at dimensionless time 47.0.

Water Mass Distribution and Seasonal Circulation Northwest of Cheju Island in 1994

  • PANG Ig-Chan;RHO Hong-Kil;LEE Jae-Hak;LIE Heung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.6
    • /
    • pp.862-875
    • /
    • 1996
  • The CTD data observed in the sea northwest of Cheju Island have been analyzed to figure out the seasonal circulation around Cheju Island. Warm and saline waters flow into the Yellow Sea through the middle region of the Yellow Sea in winter and along the west coast of Korean Peninsula in summer. On the other hand, cold and less saline waters flow out of the Yellow Sea through the middle region in summer and along the west coast of Korean Peninsula in winter. These flows make the seasonal circulation around Cheju Island. As dynamics, the monsoon wind and the variation of Kuroshio transport have been suggested. Comparing the observational result, the circulation driven by the variation of Kuroshio transport is strengthened by monsoon winds in the numerical model.

  • PDF

Investigation on Freezing in the Freezing Compartment of a Side by Side Refrigerator (양문형 냉장고 냉동실 결빙원인해석 및 최소화 방안)

  • Kim, Y.K.;Jung, H.Y.;Choi, Y.H.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.34-39
    • /
    • 2010
  • A side by side refrigerator is popularly used one among electric home appliances according to the rise of the customer's living standard. But the frost problem in freezing compartment comes out whenever we develop the high quality refrigerator. In this research, internal flow simulation and temperature measurement were carried out by using CFD and T-type thermocouple respectively in order to understand freezing mechanism. It was revealed that the amount of frost beneath the 1st and 2nd shelves is approximately 40% of total frost and the cause of frost generation is due to bad circulation of low speed cold flow. Using this analysis, the shapes of outlets under shelves are modified. So, the amount of frost in this modified model decreases 6% comparing to original one.

PECVD of Blanket $TiSi_2$ on Oxide Patterned Wafers (산화막 패턴 웨이퍼 위에 플라즈마 화학증착법을 이용한 균일 $TiSi_2$ 박막형성에 관한 연구)

  • Lee, Jaegab
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.153-161
    • /
    • 1992
  • A plasma has been used in a high vaccum, cold wall reactor for low temperature deposition of C54 TiSi2 and for in-situ surface cleaning prior to silicide deposition. SiH4 and TiCl4 were used as the silicon and titanium sources, respectively. The deposited films had low resistivities in the range of 15~25 uohm-cm. The investigation of the experimental variables' effects on the growth of silicide and its concomitant silicon consumption revealed that and were the dominant species for silicide formation and the primary factors in silicon consumption were gas composition ratio and temperature. Increasing silane flow rate from 6 to 9 sccm decreased silicon consumption from 1500 A/min to less than 30 A/min. Furthermore, decreasing the temperature from 650 to $590^{\circ}C$ achieved blanket silicide deposition with no silicon consumption. A kinetic model of silicon consumption is proposed to understand the fundamental mechanism responsible for the dependence of silicon consumption on SiH4 flow rate.

  • PDF

A Modeling of Intermittent-Hydraulic-Gun-Aerator (간헐식 폭기형 수체순환장치 모델링)

  • Song, Mu-Seok;Seo, Dong-Il
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.3
    • /
    • pp.183-189
    • /
    • 2005
  • A modeling of a hydraulic-gun-aerator is proposed to set up a design procedure for such devices. The aerators are used to destroy any thermal stratification that are responsible for the degradation of water qualify of lakes. The aerator produces ascending flow by using air bubbies released instantly near the bottom of the lake into a cylindrical pipe installed vertically. Differently form the diffuser-aerators, they can pull up the cold, oxygen depleted water directly to the region of the free surface, and they are believed to work effectively especially for relatively deeper lakes. Their design procedure has not been established yet though, and we propose a model focusing on the exit flow velocity at the top of the aerator through the examination of presently operating devices.

Numerical analysis for mitigating thermal stratification flow of pressurizer surge horizontal pipe by outside heating (가압기 밀림관 수평배관 외부 가열에 의한 열성층 유동 완화 수치해석)

  • Jeong, I.S.;Kim, Y.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.670-678
    • /
    • 1997
  • A method to mitigate the thermal stratification phenomenon of pressurizer surge line is proposed by heating bottom outside of horizontal pipe. Unsteady two dimensional model has been used to numerically investigate an effect of heating the bottom of pipe. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature and streamline profiles of fluids and pipe walls with time are compared with the previous study result. The numerical result of this study shows that the outside heating can relaxate the thermal stratification flow of the pressurizer surge line. Maximum dimensionless temperature difference between hot and cold sections of the pipe inner wall which causes thermal stratification was reduced from 0.514 to 0.424 at dimensionless time 1, 632 and 1, 500 respectively.

A Study on the Flow Control Forming Process and Experiment Device of Drum Clutch for Automatic Transmission (자동변속기용 드럼클러치의 유동제어 성형공정 및 실험장치 개발 연구)

  • Park, Jong-Nam
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.6
    • /
    • pp.69-76
    • /
    • 2013
  • This paper presents the development of the FCF method for the manufacturing of final products using numbers related to the minimum amount of work. The utilized product is a drum clutch, which is part of the transmission of an automobile. A double acting press is secured first and a prediction of the forming load on the practical material is made through an experiment with a plasticine model. Also, a finite element simulation using product shape and properties is performed, as well as a press experiment. A double acting press is manufactured that is suitable for a double acting experiment with a conventional hydraulic press(200 tons). A peripheral device for the press is additionally designed for experimental purposes. And, the press has as its essential points the drive speed, stroke control, etc., all of which influence the forming and is modified. Especially, a laser system is used for velocity measurement of two punches. The forming load of a practical material is predicted in order to derive a forming load formula for cold conditions on the basis of approximate similarity theory. Finite element analysis of the relative velocity ratio(RVR), etc., for most suitable flow defect(unfilling, etc.) prevention is achieved as well. The results are verified through a press experiment.

Design and Cold Test of Semi-Freejet High Altitude Environment Simulation Test Facility for High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 설계 및 상온실험)

  • Lee, Seongmin;Yu, Isang;Park, Jinsu;Ko, Youngsung;Kim, Sunjin;Lee, Jungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.2
    • /
    • pp.115-124
    • /
    • 2018
  • In this study, a cold flow test was carried out on a high-speed vehicle facility with a high-altitude environment simulator. Variable test was carried out according to the blockage ratio, angle, and length of the test model. It is confirmed that the blockage rate can be operated in the range of 40%, and that the model should be selected at an angle of 45 degrees or less. The variables of length are less dominant compared to the variables of blockage rate and angle. Through this, a database is obtained according to the parameters of the conical model of the high-speed vehicle test facility.

Classification of Wind Corridor for Utilizing Heat Deficit of the Cold-Air Layer - A Case Study of the Daegu Metropolitan City - (냉각에너지를 활용한 바람길 구성요소 분류 - 대구광역시를 사례로 -)

  • Sung, Uk-Je;Eum, Jeong-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.5
    • /
    • pp.70-83
    • /
    • 2023
  • Recently, the Korea Forest Service has implemented a planning project about wind corridor forests as a response measure to climate change. Based on this, research on wind corridors has been underway. For the creation of wind corridor forests, a preliminary evaluation of the wind corridor function is necessary. However, currently, there is no evaluation index to directly evaluate and spatially distinguish the types of wind corridors, and analysis is being performed based on indirect indicators. Therefore, this study proposed a method to evaluate and classify wind corridors by utilizing heat deficit analysis as an evaluation index for cold air generation. Heat deficit was analyzed using a cold air analysis model called Kaltluftabflussmodell_21 (KLAM_21). According to the results of the simulation analysis, the wind path was functionally classified. The top 5% were classified as cold-air generating Areas (CGA), and the bottom 5% as cold-air vulnerable Areas (CVA). In addition, the cold-air flowing Areas (CFA) were classified by identifying the flow of cold air moving from the cold air generation area. It is expected that the methodology of this study can be utilized as an evaluation method for the effectiveness of wind corridors. It is also anticipated to be used as an evaluation index to be presented in the selection of wind corridor forest sites.

Validation of Computational Fluid Dynamics Calculation Using Rossendorf Coolant Mixing Model Flow Measurements in Primary Loop of Coolant in a Pressurized Water Reactor Model

  • Farkas, Istvan;Hutli, Ezddin;Farkas, Tatiana;Takacs, Antal;Guba, Attila;Toth, Ivan
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.941-951
    • /
    • 2016
  • The aim of this work is to simulate the thermohydraulic consequences of a main steam line break and to compare the obtained results with Rossendorf Coolant Mixing Model (ROCOM) 1.1 experimental results. The objective is to utilize data from steady-state mixing experiments and computational fluid dynamics (CFD) calculations to determine the flow distribution and the effect of thermal mixing phenomena in the primary loops for the improvement of normal operation conditions and structural integrity assessment of pressurized water reactors. The numerical model of ROCOM was developed using the FLUENT code. The positions of the inlet and outlet boundary conditions and the distribution of detailed velocity/turbulence parameters were determined by preliminary calculations. The temperature fields of transient calculation were averaged in time and compared with time-averaged experimental data. The perforated barrel under the core inlet homogenizes the flow, and therefore, a uniform temperature distribution is formed in the pressure vessel bottom. The calculated and measured values of lowest temperature were equal. The inlet temperature is an essential parameter for safety assessment. The calculation predicts precisely the experimental results at the core inlet central region. CFD results showed a good agreement (both qualitatively and quantitatively) with experimental results.