• Title/Summary/Keyword: Cold distribution center

Search Result 121, Processing Time 0.025 seconds

A Quantification Method for the Cold Pool Effect on Nocturnal Temperature in a Closed Catchment (폐쇄집수역의 냉기호 모의를 통한 일 최저기온 분포 추정)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Cold air on sloping surfaces flows down to the valley bottom in mountainous terrain at calm and clear nights. Based on the assumption that the cold air flow may be the same as the water flow, current models estimate temperature drop by regarding the cold air accumulation at a given location as the water-like free drainage. At a closed catchment whose outlet is blocked by man-made obstacles such as banks and roads, however, the water-like free drainage assumption is no longer valid because the cold air accumulates from the bottom first. We developed an empirical model to estimate quantitatively the effect of cold pool on nocturnal temperature in a closed catchment. In our model, a closed catchment is treated like a "vessel", and a digital elevation model (DEM) was used to calculate the maximum capacity of the cold pool formed in a closed catchment. We introduce a topographical variable named "shape factor", which is the ratio of the cold air accumulation potential across the whole catchment area to the maximum capacity of the cold pool to describe the relative size of temperature drop at a wider range of catchment shapes. The shape factor is then used to simulate the density profile of cold pool formed in a given catchment based on a hypsometric equation. The cold lake module was incorporated with the existing model (i.e., Chung et al., 2006), generating a new model and predicting distribution of minimum temperature over closed catchments. We applied this model to Akyang valley (i.e., a typical closed catchment of 53 $km^2$ area) in the southern skirt of Mt. Jiri National Park where 12 automated weather stations (AWS) are operational. The performance of the model was evaluated based on the feasibility of delineating the temperature pattern accurately at cold pool forming at night. Overall, the model's ability of simulating the spatial pattern of lower temperature were improved especially at the valley bottom, showing a similar pattern of the estimated temperature with that of thermal images obtained across the valley at dawn (0520 to 0600 local standard time) of 17 May 2011. Error in temperature estimation, calculated with the root mean square error using the 10 low-lying AWSs, was substantially decreased from $1.30^{\circ}C$ with the existing model to $0.71^{\circ}C$ with the new model. These results suggest the feasibility of the new method in predicting the site-specific freeze and frost warning at a closed catchment.

A study on the evaluation of metal component in automatic transmission fluid by vehicle driving (차량 운행에 따른 자동변속기유(ATF) 금속분 분석평가 연구)

  • Lee, Joung-Min;Lim, Young-Kwan;Doe, Jin-Woo;Jung, Choong-Sub;Han, Kwan-Wook;Na, Byung-Ki
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.28-34
    • /
    • 2014
  • Automatic transmission fluid (ATF) is used for automatic transmissions in the vehicle as the characterized fluid. Recently, the vehicle manufacture usually guarantee for fluid change over 80000~100000 km mileage or no exchange, but most drivers usually change ATF below every 50000 km driving in Republic of Korea. It can cause to raise environmental contamination by used ATF and increase the cost of driving by frequently ATF change. In this study, we investigate the various physical properties such as flash point, fire point, pour point, kinematic viscosity, cold cranking simulator, total acid number, and metal component concentration for fresh and used ATF after driving (50000 km, 100000 km). The result showed that the total acid number, pour point, Fe, Al and Cu component had increased than fresh ATF, but 2 kind of used oil (50000 km and 100000km) had similar physical values and metal component concentration.

Experimental Study on the Spray Characteristics of Aerated Impinging Jets (기체주입 충돌제트의 분무특성에 관한 실험적 연구)

  • Lee, Keunseok;Yoon, Youngbin;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.24 no.4
    • /
    • pp.185-193
    • /
    • 2019
  • The effervescent atomizer is one of twin-fluid atomizers that aeration gas enters into bulk liquid and two-phase flow is formed in the mixing section. The effervescent atomizer requires low injection pressure and small amount of aeration gas, as compared to other twin-fluid atomizers. In this study, cold flow test was conducted to investigate the spray characteristics of aerated impinging jets. The present effervescent impinging atomizers were composed of the aerator device and like-on-like doublet impinging atomizer which had different impinging angles. To analyze the spray characteristics such as breakup length and droplet size distribution, the image processing technique was adopted by using instantaneous images at each flow condition. Non-dimensional parameters, induced by the homogeneous flow model, were used to predict the breakup length. The breakup length was decreased with the mixture Reynolds number and impinging angle increasing. The result of droplets showed that the size distribution was axisymmetric about the center of the injector and their diameter tended to decrease with increasing GLR.

Larval Timing and Distribution of the Red Snow Crab Chionoecetes japonicus near Dokdo (독도 근해 홍게(Chionoecetes japonicus) 유생의 출현시기와 분포)

  • Lee, Hae-Won;Park, Won-Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.6
    • /
    • pp.716-722
    • /
    • 2012
  • The larval occurrence of the red snow crab Chionoecetes japonicus was investigated near Dokdo in the East Sea of Korea, and the larval timing of the genus Chionoecetes in world oceans was reviewed. C. japonicus larvae were collected seasonally at 12 stations in February, May, August, and November in 2011. A Bongo net with a 303 mesh was deployed with a double oblique tow. Larvae appeared from February to August, but no larvae were found in November. Zoea I occurred at nine stations with a few zoea II in February, and were found until August. The larval densities in February were high near the northern. In May, megalopa were found at eight stations with a few zoea II. No larvae were caught in November. The larval abundance in the research area peaked in February. Overall, the larval duration of the genus Chionoecetes in the world's oceans persisted for a long time, and Chionoecetes larvae occurred during the warm season in each area. The cold temperature at the sea bottom, where gravid females are found, may prolong larval production along the distribution range of the genus Chionoecetes.

A study on the Activation Schemes of Cold Chain Logistics System in Incheon Port (인천항 콜드체인 물류체계 활성화 방안에 관한 연구)

  • Kim, Hong-seop;Shang, Yufei
    • Journal of Korea Port Economic Association
    • /
    • v.35 no.3
    • /
    • pp.19-40
    • /
    • 2019
  • Ports have been facing the adverse impacts of the global recession. In terms of imports, with a vast consumption hinterland, the Incheon Port has developed as the metropolitan's gateway. Additionally, the port's exports to China has been increasing due to a consistent increase in the demand of cold chain foods in the country. Considering the short distance between the Incheon Port and the ports in Northern China, the Incheon Port can serve as a logistics hub and a distribution center for exporting processed foodstuffs to China. The establishment of a cold chain logistics system at the Incheon Port will prove to be a robust strategy. After reviewing studies and interviews from various departments, this study suggested strengths, weaknesses, opportunities, and threats (SWOT) facing the Incheon Port, based on a SWOT analysis; it also recommended competitive strategies for the port. Additionally, the study used the analytic hierarchy process (AHP) to identify important factors such as the infrastructural, operational, cost, and technology factors. This study identified the infrastructural factor to be highly critical to the activation of the Incheon Port's cold chain system. Based on the results, the study proposed policies and strategy directions.

Tracking the Movement and Distribution of Green Tides on the Yellow Sea in 2015 Based on GOCI and Landsat Images

  • Min, Seung-Hwan;Oh, Hyun-Ju;Hwang, Jae-Dong;Suh, Young-Sang;Park, Mi-Ok;Shin, Ji-Sun;Kim, Wonkook
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.1
    • /
    • pp.97-109
    • /
    • 2017
  • Green tides that developed along the coast of China in 2015 were detected and tracked using vegetation indices from GOCI and Landsat images. Green tides first appeared near the Jiangsu Province on May 14 before increasing in size and number and moving northward to the Shandong Peninsula in mid-June. Typhoon Cham-hom passed through the Yellow Sea on July 12, significantly decreasing the algal population. An algae patch moved east toward Korea and on June 18 and July 4, several masses were found between the southwestern shores of Korea and Jeju Island. The floating masses found in Korean waters were concentrated at the boundary of the open sea and the Jindo cold pool, a phenomenon also observed at the boundary of coastal and offshore waters in China. Sea surface temperatures, derived from NOAA SST data, were found to play a role in generation of the green tides.

A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center (데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구)

  • Chang, Hyun Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.2
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

Chemical Differentiation of CS and N2H+ in Starless Dense Cores

  • Kim, Shinyoung;Lee, Chang Won;Sohn, Jungjoo;Kim, Gwanjeong;Kim, Mi-Ryang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.45.2-45.2
    • /
    • 2018
  • CS molecule is known to be adsorbed onto dust in cold dense cores, causing its significant depletion in the center region of cores. This study is aimed to investigate the depletion of CS molecule with optically thin $C^{34}S$ molecular line observations, including significance of its differentiation depending on the evolutionary status of the dense cores. We mapped five evolved starless cores, L1544, L1552, L1689B, L694-2 and L1197 using two molecular lines, $C^{34}S$ (J=2-1) and $N_2H^+$ (J=1-0) with NRO 45 m telescope. The $H^2$ column density and temperature structures of each targets were obtained by SED fitting for Herschel continuum images and the internal number density profiles by model fitting. All of the integrated intensity maps of $C^{34}S$ show depletion holes and 'semi-ring-like' distribution, indicating that the depletion of CS is clear and general. The radial profiles of CS abundance also show significant decrease towards the core center, while $N_2H^+$ abundance is almost constant or enhanced. We find that the more evolved cores with higher $H^2$ density tend to have a stronger depletion of CS. Our data strongly support claims that CS molecule generally depletes out in the central regions of starless dense cores and such chemical differentiation is closely related to their evolution.

  • PDF

Diurnal Variation, Vertical Distribution and Source Apportionment of Carcinogenic Polycyclic Aromatic Hydrocarbons (PAHs) in Chiang-Mai, Thailand

  • Pongpiachan, Siwatt
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1851-1863
    • /
    • 2013
  • Diurnal variation of particulate polycyclic aromatic hydrocarbons (PAHs) was investigated by collecting PM10 at three different sampling altitudes using high buildings in the city center of Chiang-Mai, Thailand, during the relatively cold period in late February 2008. At site-1 (12 m above ground level), B[a]P concentrations ranged from 30.3-1,673 pg $m^{-3}$ with an average of $506{\pm}477\;pg\;m^{-3}$ contributing on average, $8.09{\pm}8.69%$ to ${\Sigma}PAHs$. Ind and B[b]F concentrations varied from 54.6 to 4,579 pg $m^{-3}$ and from 80.7 to 2,292 pg $m^{-3}$ with the highest average of $1,187{\pm}1,058\;pg\;m^{-3}$ and $963{\pm}656\;pg\;m^{-3}$, contributing on average, $19.0{\pm}19.3%$ and $15.4{\pm}12.0%$ to ${\Sigma}PAHs$, respectively. Morning maxima were predominantly detected in all observatory sites, which can be described by typical diurnal variations of traffic flow in Chiang-Mai City, showing a morning peak between 6 AM. and 9 AM. Despite the fact that most monitoring sites might be subjected to specific-site impacts, it could be seen that PAH profiles in Site-1 and Site-2 were astonishingly homogeneous. The lack of differences suggests that the source signatures of several PAHs become less distinct possibly due to the impacts of traffic and cooking emissions from ground level.

Geographical Distribution and Physical Structure of Gudle-jang Paddy-field in Cheongsando (청산도 구들장논의 분포와 물리적 구조에 관한 연구)

  • Cho, Young-Jae;You, Hag-Yeol;Yoon, Won-Keun;Choi, Sik-In;Lee, Young-Ok
    • Journal of Korean Society of Rural Planning
    • /
    • v.18 no.3
    • /
    • pp.103-110
    • /
    • 2012
  • This study aims to find out the geographical distribution, the physical structure and characteristic of Gudle-jang Paddy-field in Cheongsando. On the basis of this study, the potential value and the assignment for the preservation of Gudle-jang Paddy-field were suggested. Gudle-jang Paddy-field is centrally distributed to Cheongsando and has various features as follows. First, it has the Ondol structure which is used Gudle-jang. Second, it has an irrigation canal which has functions of the tank and the prevention of cold-weather damage as well as the irrigation and drainage canal. The values of Gudle-jang Paddy-field are as follows; 1) It is the peculiar and inherent agricultural structure which is only found in Cheongsando. 2) It is the structure that the agricultural civil engineering and the agricultural water management technique of traditional methode are applied. 3) It has the worths of the traditional culture of Korea. 4) It is the important resource creating superb rural landscape of the region. In spite of these values of Gudle-jang Paddy-field, there were little efforts to preserve it. From now on, it is needed to form of sympathy about the value of Gudle-jang Paddy-field and to make efforts for preservation of it. Also the institutional and political strategy should be provided to preserve and manage Gudle-jang Paddy-field.