• Title/Summary/Keyword: Cold Wave

Search Result 173, Processing Time 0.035 seconds

Assessment of Surface Temperature Mitigation Effects of Wetlands During Heat and Cold Waves Using Daytime and Nighttime MODIS Land Surface Temperature (Terra/Aqua MODIS LST를 이용한 폭염 및 한파기간 동안 습지의 지면온도 완화효과 분석)

  • Chung, Jeehun;Lee, Yonggwan;Kim, Seongjoon
    • Journal of Wetlands Research
    • /
    • v.21 no.spc
    • /
    • pp.123-133
    • /
    • 2019
  • This study analyzed the surface temperature mitigation effect of wetlands during cold waves (below -12℃ from January to February) and heat waves (above 33℃ from July to August) in 2018. We used Terra/Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) Daytime and Nighttime Land Surface Temperature (LST) product, and the maximum and minimum air temperature observed at 86 stations of Korea Meteorological Administration (KMA). For the cold wave analysis, the LST of Terra MODIS nighttime was the highest at forest area with -12.7℃, followed by upland crop and wetland areas of -12.9℃ and -13.0℃ respectively. The urban area showed the lowest value of -14.4℃. During the heat wave, the urban area was the highest with + 34.6℃ in Aqua MODIS LST daytime. The wetland area was + 33.0℃ showing - 1.6℃ decrease comparing with urban area.

Correlation Analysis between Terra/Aqua MODIS LST and Air Temperature: Mainly on the Occurrence Period of Heat and Cold Waves (Terra/Aqua MODIS LST와 기온과의 상관성 분석: 한파 및 폭염 발생 기간을 중심으로)

  • CHUNG, Jee-Hun;LEE, Yong-Gwan;LEE, Ji-Wan;KIM, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.197-214
    • /
    • 2019
  • In this study, the correlation analysis was conducted between observed air temperature (maximum, minimum, and mean air temperature) and the daytime and nighttime data of Terra/Aqua MODIS LST(Moderate Resolution Imaging Spectroradiometer Land Surface Temperature) for 86 weather stations. All the data of the recent 11 years from 2008 to 2018 were prepared with daily base. In particular, the characteristics of the cold and heat waves incidence period in 2018 were analyzed. The correlation analysis was performed using the Pearson correlation coefficient(R) and root mean square error(RMSE). As a result of time series analysis, the trend between observed air temperature and MODIS LST were similar, showing the correlation above 0.9 in maximum temperature, above 0.8 in mean and minimum temperature. Especially, the maximum temperature was found to have the highest accuracy with Terra MODIS LST daytime, and the minimum temperature had the highest correlation with Terra MODIS LST nighttime. During the cold wave period, both Terra and Aqua MODIS LST showed higher correlations with nighttime data than daytime data. For the heat wave period, the Aqua MODIS LST daytime data was good, but the overall R was below 0.5. Additional analysis is necessary for further study considering such as land cover and elevation characteristics.

Measurement of plastic anisotropy of cold rolled steel sheets using electromagnetic acoustic transducer (EMAT를 이용한 냉연강판의 소성이방성 측정)

  • 황의찬;장경영;안봉영;이승석;김수광;김상영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.383-388
    • /
    • 1994
  • Ultrasonic sensor for evaluating plastic anisotropy was developed. Magnetostrictive type EMAT is sensor to transmit and receive the Lamb wave using magnetostriction. It is suitable for on line processing because of transmitting and receiving ultrasonic without contact ODCs(orientation distribution coefficients), W $_{400}$. W $_{420}$. W $_{440}$. were respectively calculated using zeroth order Lamb wave velocities, the calculated ODCs was used for evaluating plastic anisotropy, the results was compared for mean values of destructive tests. Besides, the Lorentz EMAT for generating longitudinal wave and two shear waves simultaneously and the Lorentz type EMAT for measuring SH wave velocities were made. ODCs were calculated using the measured resonant modes and velocities. the results of two methods show possibility of an line processing measurement.

  • PDF

Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor (초음파센서를 이용한 냉중성자원 수직공 형상측정)

  • Park, Guk-Nam;Choe, Chang-Ung;Sim, Cheol-Mu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

Investigation of Small Current Interruption Performance for New Type of Interrupting Chamber in SF$_{6}$ Gas Circuit Breaker (신차단방식 SF$_{6}$ 가스 차단기의 소전류 차단성능 연구)

  • Song, Won-Pyo;Kweon, Ki-Yeoung;Lee, Jae-Sung;Song, Ki-Dong;Kim, Maeng-Hyun;Ko, Hee-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.519-526
    • /
    • 2005
  • This paper presents computer simulation results for developing new type of SF$_{6}$ Circuit Breaker in terms of cold gas flow after small current interruption. This cold gas flows down a nozzle into the chamber of a circuit breaker. There are many difficult problems in analyzing the gas flow due to complex geometry, moving boundary, shock wave and so on. When predicting the dielectric capability of a gas circuit breaker after interruption, the gas pressure and density distributions due to the cold gas must be considered in addition to the electrical field imposed across the gas. A self-coded computational fluid dynamics (CFD) program is used for the simulation of cold gas flow in order to evaluate the electrical field characteristic across open contacts and transient characteristics of insulations after small current interruption.

Analysis of Nocturnal Cold Air Flow Characteristics for Setting of Tropical Night Response Zone in Daegu (대구시 열대야 대응 구역 설정을 위한 야간 찬공기 유동성 분석)

  • SEO, Bo-Yong;LEE, Sang-Beom;GWON, Soon-Beom;CHA, Jae-Gyu;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.3
    • /
    • pp.220-235
    • /
    • 2020
  • Heat wave generation in cities is basically affected by global warming, but it is further exacerbated by the impact of artificial heat emission and heat accumulation in the city. In particular, the effects of urban heat waves directly affect the occurrence of tropical nights. Basically, however, the choice of countermeasures against tropical nights is very limited compared to the daytime heat wave response. The purpose of this study was to analyze the characteristics of cold air flow at night as a countermeasure against tropical nights in Daegu Metropolitan City and to suggest its spatial applicability. As a research method, the spatial characteristics (flow velocity, flow rate, flow direction and range) of cold air flow in Daegu were quantitatively analyzed using KLAM_21, a cold air flow analysis program. As a result of the analysis, it was found that cold air generation and flow in the surrounding mountains of Daegu Metropolitan City was very active, but the inflow was limited to the urban area, which has tropical nights. However, it has been shown that the flow of cold air flowing from the surrounding mountains is very active in some urban areas, so it has spatial conditions that are very effective in countering tropical nights. If these spatial conditions are used for the urban planning, it will be very useful to develop countermeasures for tropical nights.

F. E.-assisted design of the eaves bracket of a cold-formed steel portal frame

  • Lim, J.B.P.;Nethercot, D.A.
    • Steel and Composite Structures
    • /
    • v.2 no.6
    • /
    • pp.411-428
    • /
    • 2002
  • Non-linear large-displacement elasto-plastic finite element analyses are used to propose design recommendations for the eaves bracket of a cold-formed steel portal frame. Owing to the thinness of the sheet steel used for the brackets, such a structural design problem is not trivial as the brackets need to be designed against failure through buckling; without availability of the finite element method, expensive laboratory testing would therefore be required. In this paper, the finite element method is firstly used to predict the plastic moment capacity of the eaves bracket. Parametric studies are then used to propose design recommendations for the eaves bracket against two potential buckling modes of failure: (1) buckling of the stiffened free-edge into one-half sine wave, (2) local plate buckling of the exposed triangular bracket area.The results of full-scale laboratory tests on selected geometries of eaves bracket demonstrate that the proposed design recommendations are conservative. The use of the finite element method in this way exploits modern computational techniques for an otherwise difficult structural design problem.

Conceptual Study for the Moderator Selection of the Cold Neutron Source Facility for HANARO

  • Cho, Young-Sik;Jonghwa Chang;Park, Chang-Oong
    • Nuclear Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.140-147
    • /
    • 1998
  • Basic concept of a cold neutron source for a 30 MW heavy water moderated reactor (HANARO) is developed. The source is a cold bottle located in a vertical hole near the reactor core. Since the bottle does not have sufficient volume for cooling, the optimum liquid mixture ratio is studied between liquid hydrogen and liquid deuterium. We also studied the variation of the gain depending on the volume of the bottle. The calculation is performed by a coupled MCNP model and by a semi-analytic approach. For the current geometry, 80% liquid deuterium mixture with liquid hydrogen gives the highest gain at 10 A neutron wave.

  • PDF

Measurement of the Shape in the Radioactive Area by Ultrasonic Wave Sensor

  • Park, Koon-Nam;Sim, Chuel-Muu;Park, Chang-Oong;Lee, Chang-Hee;Park, Jong-Hark
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2002
  • The HANARO ( High-flux Advanced Neutron Application Reactor) has been operated since 1995. The Cold Neutron (CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure exactly the size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersed ultrasonic technique is considered as the best way to measure the thickness and the diameter of the CN hole. The 4-Axis manipulator was designed and fabricated for locating the ultrasonic sensors. The transducer of an ultrasonic sensor having 10 MHz frequency leads to high resolution as much as 0.03mm. The inside diameter and thickness of 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results show that the thickness and inside diameter of the CN hole is in the range of 3.3∼6.7mm and 156∼ 165mm, respectively. This data will be a good reference for the design of the cold neutron source facility.

A Study on the treatment of pain in oriental medicine (통증(痛症)의 한방치료(韓方治療)에 관(關)한 소고(小考))

  • Ryu, Kyung-Ju
    • Korean Journal of Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.454-484
    • /
    • 1996
  • There are many factors to evoke pain, for example cold, heat, seven emotion, digestion, fatigue, venemous worms, deficiency of blood etc., and its pathogenesis is complicated. Treatments for pain in oriental medicine are as follows. 1. Pharmacotherapy is a method to treat pain by different effects of herbal medicine, for example, regulating vital energy, activating blood circulation, eliminating phlegm, and dispelling the cold evil etc. 2. Acupuncture and moxibustion therapy is a kind of external application, it has a distinct effect in relieving pain. Recently its operation method has been more developed, so new acupuncture therapies are used in clinics. There are electroacupuncture, auricular acupuncture and injection of drugs at an acupuncture points etc. 3. Oriental physiotherapy is a treatment method to stimulate acupuncture points and meridians. (1) Hot pack, Paraffin bath, Microwave, Ultrasound, Short wave, Infra-red etc. are used to treat cold syndrome by dispersing cold by warming the channels. (2) E.S.T., I.C.T., T.E.N.S., S.S.P., cupping treatment etc. are used to treat disorders of vital energy. (3) Health ion, Carbon, T.D.P., etc are used to treat conic and deficiency syndrome.

  • PDF