• Title/Summary/Keyword: Cold Shock

Search Result 195, Processing Time 0.024 seconds

A study on the pintle-tip shapes effect of nozzle flow using cold-flow test (핀틀 형상이 노즐 유동에 미치는 영향에 대한 실험적 연구)

  • Kim, Joung-Keun;Park, Jong-Ho;Lee, Jong-Hoon;Jeon, Min-Kyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.10
    • /
    • pp.985-991
    • /
    • 2010
  • The objective of this work was to investigate the pintle-tip shape effect on nozzle flow and thrust by cold flow test. When nozzle throat area was decreased by pintle movement, chamber pressure was increased monotonously but thrust was increased differently according to every pintle-tip shape. At the same chamber pressure and nozzle throat area, thrust of convex pintle-tip shape was mostly larger than that of concave one. Nozzle wall pressure distribution and magnitude of pintle-tip load depended on the pintle-tip shape, pintle position and nozzle throat area.

Thermal-Mixing Analyses for Safety Injection at Partial Loop Stagnation of a Nuclear Power Plant

  • Hwang, Kyung-Mo;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1380-1387
    • /
    • 2003
  • When a cold HPSI (High pressure Safety Injection) fluid associated with an overcooling transient, such as SGTR (Steam Generator Tube Rupture), MSLB (Main Steam Line Break) etc., enters the cold legs of a stagnated primary coolant loop, thermal stratification phenomena will arise due to incomplete mixing. If the stratified flow enters the downcomer of the reactor pressure vessel, severe thermal stresses are created in a radiation embrittled vessel wall by local overcooling. As general thermal-hydraulic system analysis codes cannot properly predict the thermal stratification phenomena, RG 1.154 requires that a detailed thermal-mixing analysis of PTS (pressurized Thermal Shock) evaluation be performed. Also. previous PTS studies have assumed that the thermal stratification phenomena generated in the stagnated loop side of a partially stagnated primary coolant loop are neutralized in the vessel downcomer by the strong flow from the unstagnated loop. On the basis of these reasons, this paper focuses on the development of a 3-dimensional thermal-mixing analysis model using PHOENICS code which can be applied to both partial and total loop stagnated cases. In addition, this paper verifies the fact that, for partial loop stagnated cases, the cold plume generated in the vessel downcomer due to the thermal stratification phenomena of the stagnated loop is almost neutralized by the strong flow of the unstagnated loop but is not fully eliminated.

Assessment of fatigue damage in 5% chrome cold rolling work roll (5% 크롬 냉간 압연용 작업롤의 피로손상 평가에 대한 연구)

  • Kwak, G.J.;Kim, K.S.;Lee, S.W.;Yeo, W.K.;Park, Y.C.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.316-321
    • /
    • 2000
  • The role of fatigue on the surface damage of 5% chrome cold milling work roll is evaluated. Uniaxial and torsional fatigue tests are carried out, and the baseline data for fatigue life evaluation are established. An appropriate multiaxial fatigue parameter is developed from the fatigue data. Fatigue tests are also performed under compressive mean stresses, and a mean stress model is formulated. A computer program is developed to assess the interaction of fatigue and grinding of the roll. The fatigue damage is computed for selected servicing conditions. It is found that the fatigue damage can be an important issue when the effect of mean stress is ignored, however the fatigue damage is negligibly small when the effect of mean stress including the residual stresses currently used is fully accounted. The result indicates that spalling due to the growth of thermal shock cracks is more important than fatigue damage in roll surface failure.

  • PDF

Evaluation Method I of the Small Current Breaking Performance for SF(sub)6-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$ 가스차단기의 소전류 차단성능 해석기술 I)

  • 송기동;이병운;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.331-337
    • /
    • 2001
  • With the increasing reliability of analysis schemes and the dramatically increased calculating speed, the computer simulation has become and indispensable process to predict the interruption capacity of circuit breakers. Generally, circuit breakers have to possess both the small current and large current interruption abilities and the circuit breaker designers need to evaluate its capacities to save the time and the expense. The analysis of small current and the large current interruption performances have been considered separately because the phenomena occurring in a interrupter are quite different. To analyze the dielectric recovery after large current interruption many physical phenomena such as heat transfer, convection and arc radiation, the nozzle ablation, the ionization of high temperature SF(sub)6 gas, the electric and themagnetic forces and so forth mush be considered. However, in the analysis of small current interruption performance only the cold gas flow analysis needs to be carried out because the capacitive current is to small that the influence from the current can be neglected. In this paper, an empirical equation which is obtained from a series of tests to estimate the dielectric recovery strength has been applied to a real circuit breaker. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

Cold Test and Internal Flow Analysis of Semi-Freejet Type High Altitude Environment Simulation Test Facility for the High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 상온시험 및 내부유동 해석)

  • Lee, Seongmin;Yu, Isang;Choi, Jiseon;Oh, Junghwa;Shin, Minkyu;Ko, Youngsung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.290-296
    • /
    • 2018
  • In this study, the cold test and the numerical analysis were carried out according to the shape parameters of the test model in order to confirm the operation range of high altitude environment simulation test facility for the supersonic vehicle. The blockage ratio, angle and length ratio were considered as the design parameters. The blockage rate is expected to be limited in the region of more than 40% due to the normal shock and expansion fan. It was confirmed that the angle of model should be selected at the size of 45 degrees or less due to the influence of the strong shock wave. There was no difference in performance between the lengths of 8 times the model diameter. Finally, we obtained the performance database according to the shape parameters of the conical test model and confirmed the operable range of the semi-freejet type high altitude environment simulation test facility.

Numerical Analysis of Single Phase Thermal Stratification in both Cold Legs and Downcomer by Emergency Core Cooling System Injection : A Study on the Necessity to Consider Buoyancy Force Term (비상노심냉각계통 주입에 따른 저온관 및 강수관에서 단상 열성층 수치해석 : 부력항 고려 필요성에 관한 연구)

  • Lee, Gong Hee;Cheong, Ae Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.12
    • /
    • pp.654-662
    • /
    • 2017
  • When emergency core cooling system (ECCS) is operated during loss of coolant accident (LOCA) in a pressurized water reactor (PWR), pressurized thermal shock (PTS) phenomenon can occur as cooling water is injected into a cold leg, mixed with hot primary coolant, and then entrained into a reactor vessel. Insufficient flow mixing may cause temperature stratification and steam condensation. In addition, flow vibration may cause thermal stresses in surrounding structures. This will reduce the life of the reactor vessel. Due to the importance of PTS phenomenon, in this study, calculation was performed for Test 1 among six types of OECD/NEA ROSA tests with ANSYS CFX R.17. Predicted results were then compared to measured data. Additionally, because temperature difference between the hot coolant at the inlet of the cold leg and the cold cooling water at the inlet of the ECCS injection line is 200 K or more, buoyancy force due to density difference might have significant effect on thermal-hydraulic characteristics of flow. Therefore, in this study, the necessity to include buoyancy force term in governing equations for accurate prediction of single phase thermal stratification in both cold legs and downcomer by ECCS injection was numerically studied.

Cloning of Heat Shock Protein 70 and Its Expression Profile under an Increase of Water Temperature in Rhynchocypris kumgangensis (금강모치(Rhynchocypris kumgangensis)에서 heat shock protein 70의 클로닝과 수온상승에 의한 발현 변화 분석)

  • Im, Jisu;Ghil, Sungho
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.232-238
    • /
    • 2013
  • Water temperature is key factor influencing growth and reproduction of fish and its increase give rise to various physiological changes including gene expression. Heat shock protein (Hsp), one of the molecular chaperones, is highly conserved throughout evolution and its expression is induced by various stressors such as temperature, oxidative, physical and chemical stresses. Here, we isolated partial cDNA clones encoding 70-kDa Hsp (Hsp70) and $\beta$-actin using reverse transcriptase-PCR (RT-PCR) from gut of Rhynchocypris kumgangensis, a Korean indigenous species and cold-water fish, and investigated expression profiles of Hsp70 under an increase of water temperature using $\beta$-actin as an internal control for RT-PCR. Cloned Hsp70 cDNA of R. kumgangensis showed homology to Ctenopharyngodon idella (96%), Hypophthalmichthys molitrix (96%), Danio rerio (93%) and Oncorhynchus mykiss (81%) Hsp70. Cloned $\beta$-actin cDNA of R. kumgangensis showed homology to D. rerio (98%), H. molitrix (97%), C. idella (97%) and O. mykiss (90%) $\beta$-actin. Both mRNA of Hsp70 and $\beta$-actin were expressed in gut, brain, and liver in R. kumgangensis. Futhermore, expression of Hsp70, in brain, was highly augmented by an increase of water temperature. These results suggest that Hsp70 mRNA expression level in brain can be used as a biological molecular marker to represent physiological stress against an increase of water temperature.

studies on the induction of nuclear and cytoplasmic polyhedrosis viruses by high and low temperature treatment in the silkworm, Bombsx mori L. (고온 및 저온처리에 었어서 가잠 Virus 다각체병의 유발에 대하여)

  • 강석권
    • Journal of Sericultural and Entomological Science
    • /
    • no.11
    • /
    • pp.63-68
    • /
    • 1970
  • The induction of polyhedroses in the silkworm, Bambyx mari L., was investigated treating the 5th instar larvae just after eodysis with high temperature (hot water bath at 40$^{\circ}C$ for 5 minutes or dry heat shock at 40$^{\circ}C$ for 30 minutes) and low temperature (5$^{\circ}C$ for 24 hours). The results obtained were as follows; 1. Comparing between the frequency of nuclear and cytoplasmic polyhedroses induced by cold and heat treatments (hot water bath at 40$^{\circ}C$ for 5 minutes), the induction ratio of the former is clearly less than that of the latter. But if the larvae tested with cold were left at room temperature (25$^{\circ}C$) for 30-120 minutes till the next hot water bath (40$^{\circ}C$) for 5 minutes and water bath (20$^{\circ}C$) for 5 minutes, treatments, the frequency of induced cytoplasmic polyhedrosis was more than that in the case of cold or hot water bath treatment alone. 2. The frequency of nuclear and cytoplasmic polyhedrosis induced by cold and successive heat (dry heat shock at 40$^{\circ}C$ for 30 minutes), left at room temperature (25$^{\circ}C$) ti11 the second treatment, the frequency of nuclear polyhedrosis was less than that of cytoplasmic polyhedrosis. 3. The reaction of nuclear polyhedra to stains also differs sharply from that of the cytoplasmic type. In a smear of nuclear polyhedra on a slide staining with Giemsa solution remains unstained against a stained back ground, in contrast to this, the cytoplasmic polyhedra take up stain readly.

  • PDF

Cultivation of cauliflower mushroom (Sparassis crispa) by use of coniferous sawdust-based media with wheat flour and molasses (소맥분과 물엿을 첨가한 침엽수 톱밥배지에서의 꽃송이버섯 생산)

  • Oh, Deuk-Sil;Park, Hyun;Park, Hwa-Sik;Kim, Myong-Seok;Chai, Jung-Ki
    • Journal of Mushroom
    • /
    • v.4 no.1
    • /
    • pp.39-42
    • /
    • 2006
  • Cauliflower mushroom(Sparassis crispa) contains much amount of ${\beta}$-glucan, which make lots of farmer want to cultivate the mushroom. Since a practical cultivation method is not provided yet, the mushroom is considered as a difficult crop to deal with. In this study, we tried to develope a simple method to cultivate the mushroom by use of coniferous sawdust-based medium with wheat flour and molasses. There was no significant differences between the sawdust spawn and the liquid spawn for the mycelial growth of the mushroom. The cold shock in $4^{\circ}C$ for a day was thought to be the best way to seduce primordium formation. The sawdust medium of Pseudotsuga menziesii mixed with wheat flour, corn chip, cottonseed meal and 10% molasses was showed the best yield with 41% followed by that of Larix leptolepis mixed with the same additives with 37% of yield. There was good relations between the fruit-body production and the weight loss of the sawdust substrate.

  • PDF

Studies on the Production of All-Female Populations of Olive Flounder, Paralichthys olivaceus I . Induction of Gynogenetic Diploid and Its Growth (넙치 전 암컷 집단의 생산을 위한 연구 I. 자성발생성 이배체 유도 및 성장)

  • KIM Yoon;KIM Kyung-Kil;BANG In-Chul;LEE Jong-Kwan
    • Journal of Aquaculture
    • /
    • v.6 no.4
    • /
    • pp.285-293
    • /
    • 1993
  • Gynogenetic diploid of olive flounder, Paralichthys olivaceus were induced by cold shock to fertilized eggs with red sea bream, Paragus major sperm that had been genetically inactivated with 4,800 ergs/$mm^2$ ultraviolet (UV) rays. Cold shock to the eggs at $2^{\circ}C$ for 45 minutes proved to be optimum condition to retain the second polar body. At this treatment, hatching rates of normal fry obtained were more than $33.8\%$. No different growth rates were observed up to 200 days after hatching between control and gynogenetic diploid offsprings. However, body weights of gynogenetic diploids were significantly heavier than that of control 300 days after hatching (p> 0.05). A proportion of female in gynogenetic diploid was significantly higher than that in the control (p< 0.01).

  • PDF