• Title/Summary/Keyword: Cold Neutron Source(CNS)

Search Result 9, Processing Time 0.029 seconds

Shielding design and analyses of the cold neutron guide hall for the KIPT neutron source facility

  • Zhong, Zhaopeng;Gohar, Yousry
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.989-995
    • /
    • 2018
  • Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine, and its commissioning process is underway. The facility will be used for researches, producing medical isotopes, and training young nuclear specialists. The neutron source facility is designed with a provision to include a cryogenically cooled moderator system-a cold neutron source (CNS). This CNS provides low-energy neutrons, which will be used in the scattering experiment and material structures analysis. Cold neutron guides, coated with reflective material for the low-energy neutrons, will be used to transport the cold neutrons to the experimental site. The cold neutron guides would keep the cold neutrons within certain energy and angular space concentrated inside, while most of the gamma rays and high-energy neutrons are not affected by the cold neutron guides. For the KIPT design, the cold neutron guides need to extend several meters outside the main shield of the facility, and curved guides will also be used to remove the gamma and high-energy neutron. The neutron guides should be installed inside a shield structure to ensure an acceptable biological dose in the facility hall. Heavy concrete is the selected shielding material because of its acceptable performance and cost. Shield design analysis was carried out for the CNS guide hall. MCNPX was used as the major computation tool for the design analysis, with neutron and gamma dose calculated separately. Weight windows variance reduction technique was also used in the shield design. The goal of the shield design is to keep the total radiation dose below the $5.0{\mu}Sv/hr$ guideline outside the shield boundary. After a series of iterative MCNPX calculations, the shield configuration and parameters of CNS guide hall were determined and presented in this article.

INVESTIGATION OF THE CNS HOLE SHAPE AND A PROPOSED INSTALLATION METHOD FOR A VACUUM CHAMBER FOR THE HANARO REACTOR

  • Cho Yeong-Garp;Kim Young-Ki;Lee Kye-Hong;Choung Yun-Hang
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.455-458
    • /
    • 2006
  • The HANARO reactor has a vertical hole for a cold neutron source (CNS) in the heavy-water reflector tank, i.e., the CNS hole, which was considerably deformed during its welding to the horizontal cold neutron (CN) beam tube. This paper presents an investigation of the form of the CNS hole for the optimal design of the a vacuum chamber for the CNS. In addition, the installation method of the vacuum chamber into the CNS hole for minimizing the water thickness between the vacuum chamber and the nose of the CN beam tube is proposed.

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF

A Study on Cooling of the CNS Moderator in HANARO (하나로 냉중성자원 감속재의 냉강에 대한 연구)

  • 박국남;박종학;조만순;최창웅;유성연
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.177-181
    • /
    • 1999
  • Cold Neutron Source(CNS) facility comprises moderator circulation system, helium cooling system, neutron guide and auxiliary sistems. To increase the amount of cold neutron, the thermal neutron should pass cold moderator at cryogenic temperature. As cold moderator in Hanaro, the liquid hydrogen or liquid deuterium will be used and the temperature in operation will be used and the temperature in operation will be maintained to be $250^{\circ}C$ below zero. To maintain the moderator at this cryogenic temperature. He refrigerator is used to cool it down in thermosiphon having natural circulation. As a part of the conceptual design of Hanaro CNS, study on the characteristics of moderators, design of moderator chanmber and cooling method were done through the collaboration of Korea Atomic Energy Research Institute and Petersburg Nuclear Physics Institute. During the collaboration, a program for the design of moderator cooling system design concept through the parametric study using this program. In the parametric study, the effect of the moderator type on the design parameters was investigated. Also, the requirements on the performance test for the cooling system, which will be made before the basic design, were investigated.

  • PDF

A Closed Counter-Current Two-Phase Thermosyphon Loop of a Cold Neutron Source in HANARO Research Reactor (하나로 원자로에 설치될 대향 이상 열사이펀 루프에 관한 실험)

  • Hwang, Kwon-Sang;Cho, Man-Soon;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1038-1045
    • /
    • 2000
  • An experimental study was carried out to delineate the flow characteristics in a closed countescurrent two-phase thermo syphon with concentric tubes. This is to be installed in the HANARO research reactor as a part of a Cold Neutron Source(CNS). In the present investigation, experiments ata room temperature with Freon-II3 as a moderator were performed. Results show that, based on the magnitude of pressure fluctuation, the flow regimes could be divided into 4 distinct ones in the ($V_f,\;Q_i$) plane, where $V_f$ represents the volume of the charged liquid and $Q_i$ the heat load: a stable flow regime, an oscillatory flow regime, a restablized flow regime and a dryout flow regime. For $V_f$>2.5l, the flow is stable at low $Q_i$. However, as $Q_i$ increases, the flow becomes oscillatory and finally restablizes As $V_f$ increases, the oscillation amplitude decreases, reaching to the restablized flow region at low $Q_i$, and the liquid level in the moderator cell remains high. In the oscillatory flow regimes, for a fixed VI; the oscillating period of time varies with $Q_i$, having a minimum value at a certain value of $Q_i$. The heat load, where the oscillating period of time is minimum, decreases as $V_f$ increases.

FMEA for CNS Facility and Cause Analysis of Shutdown Events to Improve Reactor Availability (원자로 이용률 향상을 위한 냉중성자원 시설의 고장모드영향분석 및 정지이력의 원인분석)

  • Lee, Yoon-Hwan;Hwang, Jeong Sik
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.115-120
    • /
    • 2020
  • From 2009 when the CNS facility was installed, the number of reactor failures due to abnormal CNS facility system has increased significantly. Of the total of 19 nuclear reactor shutdowns over the six years from 2009 to 2019, there were 10 nuclear reactor shutdowns associated with the CNS facility, which are very numerous. Therefore, this report intends to analyze the history of nuclear reactor shutdowns due to CNS facility system failure in detail, and to present the root cause and solution to problems. As a result of FMEA implementation of CNS facility system, a total of 76 SPVs were selected. In addition, 10 cases of reactor shutdown history due to CNS facility system abnormalities were analyzed in detailed, and improvement plans for solving the root cause and problem were suggested for each trip history. The results of this study are expected to be able to operate the domestic research reactor and CNS facilities more stably by providing effective measures to prevent recurrence of CNS facilities and reactor trips.

Analysis of Reliability Variation Affected by the Newly Installed Experimental Facilities in the HANARO Research Reactor (신규 실험설비 운전으로 인한 하나로 연구용 원자로의 운영 신뢰도 변화 분석)

  • Jung, Hoan-Sung;Lim, In-Cheol
    • Journal of Applied Reliability
    • /
    • v.10 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • The HANARO nuclear research reactor had been operated successfully and smoothly up to the year 2008 since its first year of instability in year 1995 just after the completion of construction. But the reliability of the reactor has been degraded from the year 2009 due to new experimental facilities such as Feul Test Loop(FTL) and Cold Neutron Source(CNS) which were installed in the HANARO plant. It turned out that these new facilities contributed unexpected stoppage of the plant. This paper describes causes of stoppage and suggestions to improve the reliability of the plant.

하나로 냉중성자원 헬륨 이중배관의 특성

  • Choe, Ho-Yeong;Kim, Min-Su;Son, U-Jeong;Lee, Mun;Han, Jae-Sam;Jo, Seong-Hwan;Heo, Sun-Ok;An, Guk-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.361-361
    • /
    • 2011
  • 하나로 냉중성자원(CNS: Cold Neutron Source)은 원자로 수조내 반사체 탱크에 위치한 수직 조사공에 설치되어 하나로 노심에서 발생하는 열중성자를 감속재인 액체 수소층을 통과시켜 냉중성자를 생산한다. 생성된 냉중성자는 유도관을 통하여 냉중성자 산란장치에 공급되어 이용 연구에 활용된다. 감속재로 사용되는 수소는 헬륨냉동계통의 운전에 따라 수소가 수조내기기 집합체(IPA: In Pool Assembly) 내로 이동되어 액화되어지므로, 극저온의 헬륨가스의 흐름이 중요하다. 헬륨냉동기에 의해 만들어진 극저온인 헬륨은 IPA 내의 수소와 열교환을 하기 위해서 배관을 통해 이동되며, 열손실없이 전달하기 위하여 헬륨 배관은 진공층이 형성된 이중배관으로 설계되어 있다. 헬륨 이중배관은 공급 및 회수 배관으로 구성되어 있으며, 헬륨 배관의 외관에 진공층을 20개의 구간으로 나누어 제작 및 설치되었으며, 각각의 진공도를 유지하고 있다. 이 논문에서는 하나로 냉중성자원 헬륨 이중배관의 특성과 헬륨냉동계통의 운전 및 정지시 온도 변화에 따른 이중배관 진공도의 변화를 분석하였다.

  • PDF