Abstract
The HANARO nuclear research reactor had been operated successfully and smoothly up to the year 2008 since its first year of instability in year 1995 just after the completion of construction. But the reliability of the reactor has been degraded from the year 2009 due to new experimental facilities such as Feul Test Loop(FTL) and Cold Neutron Source(CNS) which were installed in the HANARO plant. It turned out that these new facilities contributed unexpected stoppage of the plant. This paper describes causes of stoppage and suggestions to improve the reliability of the plant.