• Title/Summary/Keyword: Cold Flow Test

Search Result 222, Processing Time 0.027 seconds

Spray Characteristics According to the Variation of Design Parameters and Gas-liquid Momentum-flux Ratio in a Swirl-coaxial Injector Applied to Small Rocket Engine (소형로켓엔진에 적용된 스월 동축형 인젝터의 형상변수와 기체-액체 운동량 플럭스 비에 따른 분무특성)

  • Hyun Jong Ahn;Yun Hyeong Kang;Jeong Soo Kim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.27-36
    • /
    • 2023
  • To understand the atomization performance in gas-liquid swirl-coaxial injector applied to a small rocket engine, a cold-flow test was performed by varying the design parameters and supply condition of propellants. As the swirl-chamber diameter and the angle of the convergent section, which are design parameters of injector increased, the spray performance of the injector improved by increasing the swirl strength. In addition, as the gas-liquid momentum-flux ratio increased, the gas flow separated some of the droplets from the liquid film, and a gas-droplet mixture core was formed in the center of the spray sheet.

Pressure Control of Staged Combustion Liquid Rocket Engine (다단연소사이클 액체 로켓엔진의 압력제어에 대한 연구)

  • Hwang, Changhwan;Lee, Kwangjin;Woo, Seongphil;Im, Ji-Hyuk;Jeon, Junsu;Lee, Jungho;Yoo, Byungil;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.18-23
    • /
    • 2018
  • For the control of pre-burner combustion pressure, the open angle of the TTR (Throttle for Thrust Regulation) valve was varied from $143^{\circ}$ to $185^{\circ}$ while testing cold flow, ignition, and combustion. The major performance variables of rocket engines and hydraulic performance of the TTR valve regarding the open angle were verified. However, the controllability of pre-burner combustion pressure was not verified due to the limitations of the test. Comprehensive research will be done after addressing these problems.

Cold Test and Internal Flow Analysis of Semi-Freejet Type High Altitude Environment Simulation Test Facility for the High-Speed Vehicle (초고속 비행체를 위한 준 자유흐름식 고공환경 모사시험설비의 상온시험 및 내부유동 해석)

  • Lee, Seongmin;Yu, Isang;Choi, Jiseon;Oh, Junghwa;Shin, Minkyu;Ko, Youngsung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.290-296
    • /
    • 2018
  • In this study, the cold test and the numerical analysis were carried out according to the shape parameters of the test model in order to confirm the operation range of high altitude environment simulation test facility for the supersonic vehicle. The blockage ratio, angle and length ratio were considered as the design parameters. The blockage rate is expected to be limited in the region of more than 40% due to the normal shock and expansion fan. It was confirmed that the angle of model should be selected at the size of 45 degrees or less due to the influence of the strong shock wave. There was no difference in performance between the lengths of 8 times the model diameter. Finally, we obtained the performance database according to the shape parameters of the conical test model and confirmed the operable range of the semi-freejet type high altitude environment simulation test facility.

비연소 혼합시험을 통한 이중스월 분사기의 연소성능 예측

  • Ryu, Eung-Hyun;Han, Jae-Seob;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.7-7
    • /
    • 2000
  • 액체추진 로켓 분야에서 비연소 혼합시험(cold flow mixing test)은 로켓엔진의 성능을 예측하고 인젝터와 관련된 문제의 진단에 도움을 줄 수 있는 자료를 확보할 수 있는 수단이 된다. 비연소 혼합시험이 실제 연소시험을 대신할 수 있는 신뢰성 있는 자료를 제공할 수는 없지만, 인젝터의 최적형상을 설계하기 위해서 실시해야할 고 비용의 연소시험에 대한 횟수를 줄일 수 있는 보조시험으로서의 역할을 할 수 있다. 혼합시험 성능이 우수한 인젝터가 수력학적인 혼합성능을 능가하는 연소반응에 의해서 실제 연소시험에서는 성능이 저하되는 경우도 있을 수 있으나 대부분의 경우에는 비연소 혼합시험에서 좋은 성능을 나타내는 인젝터는 실제 연소시험에서도 좋은 성능을 나타낸다. 일반적으로 비연소시험과 연소시험 사이의 상관 관계를 정확히 정립하기 위해서는 많은 상관 관계 변수의 적용 및 충분한 혼합시험 자료가 요구된다.

  • PDF

A Study on the Development of Stoichiometric Direct Injection Gasoline Engine by Homogeneous Charge (균일 혼합기를 이용한 이론 공연비 직접분사 가솔린 엔진 개발에 관한 실험적 연구)

  • 이내현;유철호;최규훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.32-42
    • /
    • 1998
  • Lean burn gasoline engine is recognized as a promising way to meet better fuel economy. Lean burn engine is classified into port injection and direct injection(DI), DI is more active technique for improving fuel economy with ultra-lean operation, Nowadays, port injected lean burn engine has been produced by many Japan maker. Also, DI engine is also possible for production owing to improvement in control technique of spray, flow air fuel ratio. DI engine uses either homogeneous stoichiometric mixture or stratified mixture by controlling injection timing to be early or late respectively. HM(homogeneous mixture) is worse than SM(stratified mixture) in view of ultra-lean operation in partical load and Nox reducion by using EGR control. But, HM has advanteges in cold starting and emission reduction during transient operation, This paper describes experimental variables and bench test results of HM GDI engine.

  • PDF

A Study on Grooving Corrosion at the Weld of a Low Carbon Steel Pipe Made by Electrical Resistance Welding (탄소강관의 ERW 용접부 홈부식 손상에 관한 연구)

  • Kim Yong;Lee Bo-Young
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.58-64
    • /
    • 2004
  • Although leakage at a low carbon steel pipe made by electrical resistance welding (ERW) was reported due to grooving corrosion, the cause for the corrosion has not yet been cleared. In order to clarify the main cause, failure analysis on the leaked pipe was carried out, followed by metallographic investigation and corrosion test for the various ERW pipe made with different welding heat input. The microstructure, particularly inclusion content, of the weldment is dependant on the welding heat input applied. For an improper low heat input, the amount of inclusion at the weld was high. High inclusion content accelerated grooving corrosion at the weld. It is therefore that welding heat input should be controlled based on the carbon content of the pipe in order to improve the corrosion resistance of the ERW pipe.

Evaluation of Transient Natural Circulation Behavior during Accident in Low Power /Shutdown Condition of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.458-463
    • /
    • 1997
  • A transient natural circulation behavior during a LOCA at hot-standby operation is evaluated for YGN Units 3/4. The plant initial condition is determined within the EOP limitation as suitable to hot-standby mode and the transient scenario is prepared as relevant to evaluation of transient natural circulation. A 0.4% cold leg break with loss of off-site power is calculated with RELAP5/MOD3.2, whose predictability has been verified for SBLOCA natural circulation test, S-NC-8B. Through one hour transient analysis, it is found that the plant has its own decay heat removal capability by natural circulation following a LOCA, at hot-standby mode. Additional calculation is performed to investigate an effect of HPSI flow on natural circulation.

  • PDF

Gasification characteristics of entrained flow gasifier (습식 가스화 장치에서 버너 형태에 따른 가스화 특성)

  • Ra, Ho-Won;Lee, Jae-Goo;Choi, Young-Chan;Yoon, Sang-Jun;Son, Young-Il;Hong, Jae-Chang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.250-253
    • /
    • 2008
  • 최근 석탄 가스화 기술은 화석연료인 석탄을 기존의 공해물질 발생을 90%이상 줄이면서 고효율로 활용할 수 있는 방법으로 각광받고 있다. 본 연구는 당 센터에서 보유하고 있는 습식 석탄 가스화기의 성능 향상을 위하여 버너의 형태에 따른 미립화 특성을 파악하였으며, 가스화기의 버너로 적용하여 가스화 특성 실험을 실시하였다. 미립화 특성을 파악하기 위하여 개발되어진 3가지 형태의 버너를 Cold Test장치를 이용하여 $O_2$/Fuel Ratio 및 버너의 내부 혼합 방식, 분사각도에 따른 미립화 특성을 관찰하였으며, 입도 분석은 심파텍사의 입도 분석기를 이용하여 측정하였다. 실험 결과 이중혼합식 버너가 미립화 특성이 가장 우수하게 나타났으며, 외부혼합식 버너와 환형 버너의 경우 비슷한 미립화 특성을 나타내었다. 가스화기에 적용하여 실험한 결과 미립화 특성이 우수하게 나타나는 경우 가스화 특성 또한 우수하게 나타남을 확인하였다.

  • PDF

A Study on the Thermal Pump of the Hot Water Boiler (온수 보일러용 열구동 펌프에 관한 연구)

  • Yeom, Han-Gil;Kim, Uk-Joong;Kim, Chang-Ju
    • 연구논문집
    • /
    • s.30
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers (초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II)

  • 송기동;이병윤;박경엽;박정후
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF