• Title/Summary/Keyword: Cold Energy

Search Result 1,235, Processing Time 0.034 seconds

A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice - (공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향-)

  • 이병화;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

A Study on the Integrated Fusion Technology Between a Carbon Dioxide Emission and a District Cooling Energy Using a Cold Energy ($CO_2$ 배출문제와 냉열이용 지역집단 냉방에너지에 관한 통합적 융합기술 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.34-40
    • /
    • 2006
  • This paper provides a fusion technology between a district cooling energy system and an environment conservation policy based on the energy savings and reusable cold energy resources. The district heating and cooling systems are very effective ways for an energy saving, a cost reduction and a safety control. It is necessary to equalize the energy savings and an environmental preservation policy for an improved human lift. A gasification process of a liquefied natural gas, cooling water from deep seawater and an ice water thermal storage system may produce a cold energy. A district cooling system is used to cool an apartment, office buildings and factory facilities with a cooling energy supply pipeline. LNG cooling energy will switch a conventional air-conditioning system, which is operated by on electrical energy and a Freon refrigerant. Coincident with significant clean energy and operating cost savings, LNG cold energy system owen radical reductions in an air-borne pollutant, $CO_2$ and the release of environmentally harmful refrigerants compared with that of the conventional air-conditioning system. This study provides useful information on the fusion technology of a LNG cold energy usage and energy savings, and environmental conservation.

  • PDF

Design and Exergy Analysis for a Combined Cycle of Liquid/Solid $CO_2$ Production and Gas Turbine using LNG Cold/Hot Energy

  • Lee, Geun-Sik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.1
    • /
    • pp.34-45
    • /
    • 2007
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a solid $CO_2$ production ratio. The present study shows that much reduction in both $CO_2$ compression power (only 35% of the power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency (55.3% at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a solid $CO_2$ production ratio increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

Study of Thermal Storage Technology using Phase Change Material (잠열물질을 이용한 열저장 기술에 관한 연구)

  • Kim, Jeong-Yeol;Chung, Dong-Yeol;Park, Dongho;Peck, Jong-Hyeon
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • The cold chain system in South-East Asia is requiring to maintain freshness of refrigerated or frozen food. In this study, Thermal storage system using Phase change material (PCM) was developed and evaluated its performance about temperature and cold keeping time. For various application of cold chain system, we developed portable cold box, cold roll container and freezing station. Keeping time on laboratory tests of portable cold box in case of refrigeration and freezing were 6 hours and 4 hours, respectively. Cold container was developed to 2.5 ton scale. Evaluation in Indonesia, it was showed to keep the setting temperature of $-10^{\circ}C$ over 40 hours at $30^{\circ}C$ of ambient air. Freezing station using PCM was kept over 24 hours under $-20^{\circ}C$.

  • PDF

Analysis of Performance of Building Integrated PV System into Cold Facade (건물일체형 Cold Facade PV 시스템의 성능 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;Park, Kyung-Eun;Yu, Gwon-Jong;Suh, Seung-Jik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1104-1105
    • /
    • 2008
  • This paper presents the assesment of experimented data and estimated data for electrical and thermal performance evaluation of building integrated photovoltaic(BIPV) system of cold facade type. BIPV module is used to estimate the dependence of module temperature on irradiance, ambient temperature and indoor temperature. The module temperature of no free ventilated facade PV system is higher than cold facade PV system about 13.4$^{\circ}C$. By the results on simulation, the reduction of electrical power loss is 9.57% into cold facade according to free ventilation. The annual averaged PR of BIPV system into cold facade is about 73.1%.

  • PDF

Effects of Soup Temperature on Hunger, Energy and Nutrient Intake (국의 온도가 공복감, 열량 및 영양소 섭취량에 미치는 영향)

  • 김석영;장희애;김주영;박경민
    • Journal of Nutrition and Health
    • /
    • v.36 no.8
    • /
    • pp.859-869
    • /
    • 2003
  • The purpose of this study was to compare the effects of soup temperature on hunger, energy, and nutrient intake. The hot meal consisted of 400 g of hot beef-vegetable soup (75$^{\circ}C$), Yubu Chobap, Bulgogi, cucumber pickle and radish pickle. The cold meal component were the same as the hot meal except 300 g of water (8$^{\circ}C$) and boiled vegctables (100 g), instead of the hot beef-vegetable soup ot the hot meal. Thirst, core temperature and blood pressure were also measured before and after consumption the test meals in a within-subjects, repeated measures design. 30 women consumed 17% more kilocalories, 13% more protein and lipid and 16% more carbohydrate in the cold meal than in the hot meal. The core temperature at the end of the test meal was higher in the hot meal than in the cold meal. Energy and nutrient intake were inversely correlated with the hunger scores within 1 hour after the hot meal, however those are not related with each other in the cold meal. So hunger feeling might be disturbed in the cold meal. It is concluded that energy and nutrient consumptions were higher in the cold meal, partly because of the distrubed hunger feeling in the cold meal.

Thermal Analysis of a Cold Box for a Hydrogen Liquefaction Pilot Plant with 0.5 TPD Capacity (0.5 TPD 급 수소액화 파일럿 플랜트의 콜드박스 열해석)

  • KIM, HYOBONG;HONG, YONG-JU;YEOM, HANKIL;PARK, JIHO;KO, JUNSEOK;PARK, SEONG-JE;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.571-577
    • /
    • 2020
  • Thermal analysis was performed for a cold box of a hydrogen liquefaction pilot plant with 0.5 ton/day capacity. The pilot plant has adopted a hydrogen liquefaction process using two-stage helium Brayton cycle with precooling of liquid nitrogen. The cold box for hydrogen liquefaction has generally vacuum insulation but inevitable heat invasion by conduction and radiation exists. The heat loads were calculated for cold box internals according to multilayer insulation emissivity. Total heat load of 181.7 W is estimated for emissivity of 0.03 considered in field condition.

Effects of the partial admission rate and cold flow inlet-outlet ratio on energy separation of Vortex Tube (Vortex Tube의 부분유입율과 저온 입.출구비가 에너지분리 특성에 미치는 영향)

  • 김정수;추홍록;상희선
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.51-59
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air conditioner for special purpose. The phenomena of energy separation through the vortex tube were investigated to see the effects of cold flow inlet-outlet ratios and partial admission rates on the energy separation experimentally. The experiment was carried out with various cold flow inlet-outlet ratios from 0.28 to 10.56 and partial admission rates from 0.176 to 0.956 by varying input pressure and cold air flow ratio. To find best use in a given cold flow inlet-outlet ratio and partial admission rate, the maximum temperature difference of cold air was presented. The experimental results were indicated that there are an optimum range of cold flow inlet-outlet ratio for each partial admission rate and available partial admission rate.

  • PDF

Ventilation Rate Impact on Heating and Cooling Energy Consumption in Residential Buildings : Concentrated on a Detached House in Cold and Hot/Humid Climatic Zones of USA (환기량의 주거건물 냉난방에너지 소비에 대한 영향 : 미국 한랭기후 및 고온다습기후의 단독주택을 중심으로)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.747-753
    • /
    • 2011
  • The purpose of this study was to quantify the impact of the ventilation rate on heating and cooling energy consumption in a detached house. For it, a series of simulations for the application of the diverse ventilation rate (ACH) were computationally conducted for a prototypical detached residential building in the cold climate (Detroit, Michigan) and hot/humid climate (Miami, Florida) of USA. Analysis revealed that ventilation is a significant heat losing source in the cold climate; thus, the higher ventilation rate significantly increases the heating energy consumption and energy cost in the cold climate; while the impact on energy increase for heating and cooling energy consumption is similar in hot/humid climate with less significancy compared to cold climate. The research outcome of this study could be a fundamental data for determining the optimal ventilation rate in terms of indoor air quality, but also building energy performance well.