• 제목/요약/키워드: Cold Bending

검색결과 121건 처리시간 0.024초

Residual stress of cold-formed thick-walled steel rectangular hollow sections

  • Zhang, Xingzhao;Liu, Su;Zhao, Mingshan;Chiew, Sing-Ping
    • Steel and Composite Structures
    • /
    • 제22권4호
    • /
    • pp.837-853
    • /
    • 2016
  • This paper presents the experimental and numerical study on the distribution of transverse and longitudinal residual stresses in cold-formed thick-walled structural steel rectangular hollow sections manufactured by indirect technique. Hole-drilling method is employed to measure the magnitude of the transverse and longitudinal surface residual stress distribution, and the effects of the residual stresses are evaluated qualitatively by sectioning method. It is shown that compared to normal cold-formed thin-walled structural hollow sections (SHS), the cold-formed thick-walled SHS has similar level of residual stress in the flat area but higher residual stresses in the corner and welding areas. Both the transverse and longitudinal residual stresses tend to open the section. In order to predict the surface residual stresses in the corners of the cold-formed thick-walled SHS, an analytical model is developed. 2D finite element simulation of the cold bending process is conducted to validate the analytical approach. It is shown that in analyzing bending for thick-walled sections, shifting of neutral axis must be considered, since it would lead to nonlinear and non-symmetrical distribution of stresses through the thickness. This phenomenon leads to the fact that cold-formed thick-walled SHSs has different distribution and magnitude of the residual stresses from the cold-formed thin-walled SHSs.

Determination of slip modulus of cold-formed steel composite members sheathed with plywood structural panels

  • Karki, Dheeraj;Far, Harry;Al-hunity, Suleiman
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.511-522
    • /
    • 2022
  • An experimental investigation to study the behaviour of connections between cold-formed steel (CFS) joist and plywood structural panel is presented in this paper. Material testing on CFS and plywood was carried out to assess their mechanical properties and behaviour. Push-out tests were conducted to determine the slip modulus and failure modes of three different shear connection types. The employed shear connectors in the study were; size 14 (6mm diameter) self-drilling screw, M12 coach screw, and M12 nut and bolt. The effective bending stiffness of composite cold-formed steel and plywood T-beam assembly is calculated based on the slip modulus values computed from push-out tests. The effective bending stiffness was increased by 25.5%, 18% and 30.2% for self-drilling screw, coach screw, nut and bolt, respectively, over the stiffness of cold-formed steel joist alone. This finding suggests the potential to enhance the structural performance of composite cold-formed steel and timber flooring system by mobilisation of composite action present between timber sheathing and CFS joist.

요소수지접착제(尿素樹脂接着劑)를 사용(使用)한 곰솔 집성재(集成材)의 제조조건(製造條件)이 접착성질(接着性質)에 미치는 영향(影響) (Influence of Adhesion Condition on the Laminated Wood of Pinus thunbergii glued with Urea-formaldhyde Resin)

  • 정인오;소원택;임기표
    • Journal of the Korean Wood Science and Technology
    • /
    • 제12권2호
    • /
    • pp.35-43
    • /
    • 1984
  • This study was carried out to investigate the block shear strength of the 2ply laminated wood composed of Pinus thunbergii with ureaformaldehyde resin as adhesives according to pressure (6, 9, 12, 15kg/$cm^2$), pressing time(5, 10, 20, 30 hrs.), amount of spread(54, 108, 217, 324g/$cm^2$), hardener(10, 20, 30, 40% of 10% $NH_4CL$ on resin) and extender(0, 5, 10, 15% wheat flour on resin), and the bending strength and bending young's modulus of laminated beam according to the number of ply. The results were summarized as follows; 1. According to pressing pressure with amount of spread 217g/$cm^2$ both dry and wet shear strength of laminated wood showed the highest in 15kg/$cm^2$, and hot-cold soaking treatment showed the highest in 9kg/$cm^2$, while all shear strength of dry, wet and hot-cold soaked laminated wood have been reduced with the increasing of pressing time. 2. According to amount of spread, adhesion strength with the dry, wet and hot-cold soaking treatments revealed the highest in 217g/$cm^2$ and have been reduced under or over 217g/$cm^2$ of spread. 3. According to addition of hardener and extender, all shear strength of laminated block with the dry, wet and hot-cold soaking treatments have been reduced in increasing of addition amount of hardener and extender. The bending strength of beam according to the number of ply showed the highest in 2ply laminated wood and horizontal loading beam to glue line had the higher in strength than the vertical loading.

  • PDF

압축과 휨의 조합하중을 받는 냉간성형강 기둥의 내력성능 (Load Carrying Capacities of Cold Formed Steel Structural Columns subject to Combined Axial Load and Bending Moment)

  • 신태송
    • 한국강구조학회 논문집
    • /
    • 제17권1호통권74호
    • /
    • pp.83-92
    • /
    • 2005
  • 본 논문은 압축과 모멘트 조합하중을 받는 냉간성형강 기둥의 내력성능을 평가하는데 목적이 있다. 단면은 춤이 90, 150 mm이고 웨브에 엠보싱이 있는 립 ㄷ형강이다. 부재길이와 단부모멘트비를 변수로 하였고, 편심압축력을 가력하여 총 24개 실물실험을 수행하였다. 미국 AISI와 유럽 EC3 기준의 특징을 체계적으로 분석하였고, 실험결과와 기준 산정결과를 비교하였다. 두 기준 모두 합리적임을 알 수 있었다.

Experimental capacity of perforated cold-formed steel open sections under compression and bending

  • Orlando, Maurizio;Lavacchini, Giovanni;Ortolani, Barbara;Spinelli, Paolo
    • Steel and Composite Structures
    • /
    • 제24권2호
    • /
    • pp.201-211
    • /
    • 2017
  • This study evaluates the reliability of present European codes in predicting the collapse load of columns made with perforated cold-formed steel (CFS) profiles under combined axial load and bending. To this aim, a series of experimental tests on slender open-section specimens have been performed at varying load eccentricity. Preliminarily, stub column tests have also been performed to calculate the effective section properties of the investigated profile. By comparison of experimental data with code-specified M-N strength domains, the authors demonstrate that present code formulations may underestimate the collapse load of thin-walled perforated open sections. The study is the first step of a wider experimental and numerical study aimed at better describing strength domains of perforated CFS open sections.

철근의 Bending and Straightening에 대한 실험적 연구 (An Experimental Study on the Cold Bending of Reinforcing Bar)

  • 조현우;최희복;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.109-113
    • /
    • 2003
  • In this experiment, we distribute the bending angle to 60$^{\circ}$, 90$^{\circ}$, 120$^{\circ}$, and we separate it in to two groups. One is straightening right after bending and the other is straightening after one week. The bars we will use are HD13 and HD16. The number of tests will be 60 times. In the case of HD16, the increase of bending angle decreased yield strength and maximum strength. And compared with thinner bars, HD16 showed bigger differences in yield strength and maximum strength when the 'being bent' duration got longer. So it shows that when we bend and after straighten a bar, stress change takes place on the surface of the bar. At the beginning it shows it's ductility after that it deforms while transforming it's character to destroying. And also, if we straighten a bar after bending, it doesn't get straighten like the original form. So it makes torsion and this torsion makes moments in different areas.

  • PDF

Flexural performance of cold-formed square CFST beams strengthened with internal stiffeners

  • Zand, Ahmed W. Al;Badaruzzaman, W.H. Wan;Ali, Mustafa M.;Hasan, Qahtan A.;Al-Shaikhli, Marwan S.
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.123-139
    • /
    • 2020
  • The tube outward local buckling of Concrete-Filled Steel Tube (CFST) beam under high compression stress is still considered a critical problem, especially for steel tubes with a slender section compared to semi-compact and compact sections. In this study, the flexural performance of stiffened slender cold-formed square tube beams filled with normal concrete was investigated. Fourteen (14) simply supported CFST specimens were tested under static bending loads, stiffened with different shapes and numbers of steel stiffeners that were provided at the inner sides of the tubes. Additional finite element (FE) CFST models were developed to further investigate the influence of using internal stiffeners with varied thickness. The results of tests and FE analyses indicated that the onset of local buckling, that occurs at the top half of the stiffened CFST beam's cross-section at mid-span was substantially restricted to a smaller region. Generally, it was also observed that, due to increased steel area provided by the stiffeners, the bending capacity, flexural stiffness and energy absorption index of the stiffened beams were significantly improved. The average bending capacity and the initial flexural stiffness of the stiffened specimens for the various shapes, single stiffener situations have increased of about 25% and 39%, respectively. These improvements went up to 45% and 60%, for the double stiffeners situations. Moreover, the bending capacity and the flexural stiffness values obtained from the experimental tests and FE analyses validated well with the values computed from equations of the existing standards.

냉간단조된 후판형 플랜지 돌출부 굽힘성형 공정연구 (Outer Bending of a Cold Forged Circle Flange)

  • 김대원;신영철;최호준;윤덕재;신익철;임성주
    • 소성∙가공
    • /
    • 제21권7호
    • /
    • pp.453-458
    • /
    • 2012
  • The flange hub is a main component of an automotive steering system. Dimensional precision of the flange hub is very important for precise control of the steering force. Consequently, the process design for precision forming of a flange hub is required. The teeth of the flange hub are generally formed by bending. In this study, the formability of flange bending was investigated using FE simulations. For the optimum process conditions, the flange is bent by movement of an insert die, and the die angle and bending length are selected as $90^{\circ}$ and 4mm respectively.

핑거접합부의 수량 및 배치가 생태목조건축용 집성재의 휨강도에 미치는 영향 (The Effects of Number and Location of Finger Joints on the Bending Strength of Glue Laminated Wood for Green Wood Building)

  • 소원택
    • 한국가구학회지
    • /
    • 제18권1호
    • /
    • pp.20-30
    • /
    • 2007
  • This experiment was carried out to investigate the effects of number and location of finger joints on the bending strength of glue-laminated lumbers. Urea resin adhesives were used in this experiment and the resin content was 70% for cold pressing. The lamina were edge-jointed and end-jointed. The specimen were composed of one or three layers. The obtained results are summarized as follows; The effects of finger joints on the decrease of bending strength of glue laminated woods were different according to the number and location of finger joints. The decrease of MOR was highest on the middle position of laminated woods. The effects of several arrangements of finger joints on the bending strength of glue laminated woods showed on Figure 7 and 8. The variance of thickness-laminating on the bending strength of glue laminated woods were larger than those of width-laminating.

  • PDF

Finite element modeling of rolled steel shapes subjected to weak axis bending

  • Saliba, Najib G.;Tawk, Issam;Gergess, Antoine N.
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.161-173
    • /
    • 2018
  • Point bending is often used for cambering and curving structural steel girders. An analytical solution, applicable in the elasto-plastic range only, that relates applied loads to the desired curve was recently developed for inducing horizontal curves using four-point bending. This solution does not account for initial residual stresses and geometric imperfections built-in hot-rolled sections. This paper presents results from a full-scale test on a hot-rolled steel section curved using four-point bending. In parallel, a numerical analysis, accounting for both initial geometric imperfections and initial residual stresses, was carried out. The models were validated against the experimental results and a good agreement for lateral offset and for strain in the elasto-plastic and post-plastic ranges was achieved. The results show that the effect of initial residual stresses on deformation and strain is minimal. Finally, residual stresses due to cold bending calculated from the numerical analysis were assessed and a revised stress value for the service load design of the curved girder is proposed.