• Title/Summary/Keyword: Cold Air Temperature

Search Result 673, Processing Time 0.02 seconds

Server Room Temperature Condition in Data Center with Cold Aisle Containment System (냉복도 밀폐시스템을 적용한 서버실의 실내온도조건)

  • Jung, Yong-Ho;Chang, Hyun-Jae;Seo, Jang-Hoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.79-84
    • /
    • 2013
  • In this study, a cold aisle containment system was proposed among various strategies to reduce the energy waste by recirculation air from the hot aisle. To verify the effectiveness of the cold aisle containment system, a test bed which is similar to an actually existing server room was set up in the Internet Data Center(IDC) building. Comparative experiments, conventional open type cooling system and cold aisle containment system were carried out under actual conditions. The result revealed that the range of inlet temperature of the server system was $20{\sim}25^{\circ}C$ in an existing cooling system and the range of inlet temperature dropped below $20^{\circ}C$ by the cold aisle containment system. After all, cold aisle containment system was proved to be the solution for energy saving cooling system.

A Study for Energy Separation of Vortex Tube Using Air Supply System(II) - the effect of surface insulation - (공기공급 시스템에 적응되는 Vortex Tube의 에너지 분리특성에 관한 연구(II) -표면의 단열효과에 따른 영향-)

  • 방창훈;추홍록;유갑종
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.3-9
    • /
    • 1999
  • The vortex tube is a simple device which splits a compressed gas stream into a cold stream and a hot stream without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. In this study, the insulation effect of surface on the efficiency of vortex tube was performed experimentally. The experiment is carried out for nozzle area ratio of 0.194, diameter ratio of cold end orifice of 0.6 and input pressure ranging from 0.2Mpa to 0.5Mpa. The purpose of this study is focused on the effect of surface insulation of vortex tube with the variation of cold air mass flow ratio. The results indicate that the temperature difference of cold and hot air are higher about 12% and 30% than that of not insulated vortex tube respectively. Furthermore, for the insulated vortex tube, the similarity relation for the prediction of cold end temperature as the function of cold air mass flow ratio and input pressure is obtained.

  • PDF

Observation of the Cold-air Drainage and Thermal Belt Formation in a Small Mountainous Watershed by Using an Infrared Imaging Radiometer (적외선 영상 복사계를 이용한 산간집수역의 찬공기 배수와 온난대 형성 관측)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.2
    • /
    • pp.79-86
    • /
    • 2011
  • Cold-air drainage and pooling occur in most mountain valleys at night. Local climates with cold-air pooling could affect phenology and distribution of crop plants. A high resolution infrared imaging radiometer was used to visualize the cold-air drainage and thermal belt formation over a small mountainous watershed (ca. $10{\times}5{\times}1$ km for the maximum length${\times}$width${\times}$depth). Thermal images on $640{\times}480$ pixels were scanned across the Akyang valley (south of Mt. Jiri National Park) by the radiometer installed at a local peak ('Hyongjebong', 1,117 m a.s.l.) at dawn of 17 May 2011, when the synoptic condition was favorable for the surface cooling and cold-air drainage. Major findings are: (1) Cold-air drainage and accumulation was clearly identified by the lowest brightness temperature mainly at the valley bottom. (2) So-called 'thermal belt' with higher brightness temperature was found partway up the valley sidewalls and showed up to $5^{\circ}C$ departure from the valley bottom temperature. (3) Digital thermography showed feasibility for validation of the high definition geospatial temperature models currently in use for the plot-specific agrometeorological service.

A study on cooling characteristics of clathrate compound for cold storage applications (저온축열용 포접화합물에 냉각특성에 관한 실험적 연구)

  • 한영옥;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

Quality Characteristics of Dried Squid (Todarodes Pacificus) by Cold Air Drying Process (냉풍건조공정을 이용한 마른오징어의 품질특성)

  • Hong, Joo-Heon;Bae, Dong-Ho;Lee, Won-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.635-641
    • /
    • 2006
  • In an attempt to find ways of improving the quality and sanitary state of dried squid, this study compared artificial drying methods i.e. hot air drying and cold air drying with natural drying method. The drying rates of squid were in the order of hot air, cold air and natural drying. However, cold-air drying was slower than natural drying at $7^{\circ}C$. The drying rates increased with increasing drying temperature. When drying temperature was close to the dew point on a dehumidifier surface, which was the case with cold air drying at $7^{\circ}C$, the driving force for dehumidification was lower than under other drying conditions, which resulted in a lower drying rate. There were little color differences between the drying methods and temperature. Squid dried by cold air-drying had better mechanical texture and sensory qualities than with other drying methods. In addition, the cold air drying method maintained superior quality in terms of the contents of amino acids, taurine, EPA, DHA, other fatty acids and a low TBA value than the other drying methods.

The effect of the number of nozzle holes on the energy separation (보텍스튜브의 노즐홀수가 에너지분리에 미치는 영향)

  • 유갑종;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.692-699
    • /
    • 1999
  • The vortex tube is a sample device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. The phenomena of energy separation through the vortex tube were investigated experimentally, to see the effects of the number of nozzle holes on the energy separation. The experiment was carried out with the number of nozzle holes from 1 to 10 by varying inlet pressure and cold mass fraction. The experimental results were indicated that the effective number of nozzle holes for the best cooling performance was found as 4. Also, to find effective use in a given operation conditions, the temperature difference of cold air and the cooling capacity of vortex tube was compared. The result is that cooling capacity was more important than temperature difference of cold air.

  • PDF

An Experimental Study on Thermal Properties of Clathrate for Cold Storage Applications (저온축열용 포접화합물의 열물성에 관한 실험적 연구)

  • 한영옥;정낙규;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.725-734
    • /
    • 2000
  • The objective of this paper is to investigate the thermal properties of TMA clathrate applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are peformed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of concentrations and temperature of heat source in TMA clathrate. The results are summarized as follows; 1) temperature of phase change is dropped as the temperature of heat source is lower, 2) the effect of subcooling suppression with about $9.3^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 29wt% and 30wt% . Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$ Thus, it is concluded that TMA clathrate has proper properties as the cold storage medium for building air-conditioning.

  • PDF

Management Planning of Wind Corridor based on Mountain for Improving Urban Climate Environment - A Case Study of the Nakdong Jeongmaek - (도시환경개선을 위한 산림 기반 바람길 관리 계획 - 낙동정맥을 사례로 -)

  • Uk-Je SUNG;Jeong-Min SON;Jeong-Hee EUM;Jin-Kyu MIN
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.1
    • /
    • pp.21-40
    • /
    • 2023
  • This study analyzed the cold air characteristics of the Nakdong Jeongmaek, which is advantageous for the formation of cold air that can flow into the city, in order to suggest the wind ventilation corridor plans, which have recently been increasing interest as a way to improve the urban thermal environment. In addition, based on the watershed analysis, specific cold-air watershed areas were established and management plans were suggested to expand the cold air function of the Nakdong Jeongmaek. As a result of the analysis of cold air in the Nakdong Jeongaek, cold air was strongly generated in the northern forest of the Jeongamek, and flowed into nearby cities along the valley topography. On average, the speed of cold air was high in cities located to the east of the Jeongmaek, while the height of cold air layer was high in cities located to the west. By synthesizing these cold air characteristics and watershed analysis results, the cold-air watershed area was classified into 8 zones, And the plans were proposed to preserve and strengthen the temperature reduction of the Jeongmaek by designating the zones as 'Conservation area of Cold-air', 'Management area of Cold-air', and 'Intensive management area of Cold-air'. In addition, in order to verify the temperature reduction of cold air, the effect of night temperature reduction effect was compared with the cold air analysis using weather observation data. As a result, the temperature reduction of cold air was confirmed because the night temperature reduction was large at the observation station with strong cold air characteristics. This study is expected to be used as basic data in establishing a systematic preservation and management plan to expand the cold air function of the Nakdong Jeongmaek.

Development of Estimation Algorithm of Near-Surface Air Temperature for Warm and Cold Seasons in Korea (온난 및 한랭시즌의 우리나라 지상기온 평가 알고리즘 개발)

  • Kim, Do Yong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.4
    • /
    • pp.11-16
    • /
    • 2015
  • Spatial and temporal information on near-surface air temperature is important for understanding global warming and climate change. In this study, the estimation algorithm of near-surface air temperature in Korea was developed by using spatial homogeneous surface information obtained from satellite remote sensing observations. Based on LST(Land Surface Temperature), NDWI(Normalized Difference Water Index) and NDVI(Normalized Difference Vegetation Index) as independent variables, the multiple regression model was proposed for the estimation of near-surface air temperature. The different regression constants and coefficients for warm and cold seasons were calculated for considering regional climate change in Korea. The near-surface air temperature values estimated from the multiple regression algorithm showed reasonable performance for both warm and cold seasons with respect to observed values (approximately $3^{\circ}C$ root mean-square error and nearly zero mean bias). Thus;the proposed algorithm using remotely sensed surface observations and the approach based on the classified warm and cold seasons may be useful for assessment of regional climate temperature in Korea.

Development of Fuzzy Controller for Air Conditioning of Grain Bin (곡물빈용 공기조화장치의 퍼지제어기 개발)

  • 최영수;문대식;정종훈
    • Food Science and Preservation
    • /
    • v.9 no.2
    • /
    • pp.137-143
    • /
    • 2002
  • Temperature and humidity are the most important factors and should be effectively controlled for the cold storage of graius. Fuzzy logic can be easily implemented to the MIMO(Multi-Input Multi-Output) control systems. For the cold storage in grain bin, fuzzy logic was applied to an air conditioning system. The capacities of the grain bin and the air conditioner are 80 tons and 30㎾, respectively. Also, the target values of temperature and relative humidity in outlet duct of the air conditioner were 8$\^{C}$ and 75%, respectively. In order to control temperature and relative humidity of air, a damper in inlet duct was manipulated for temperature control and a heater was used for humidity control. Temperature deviation and change of temperature deviation were used as input parameters for the fuzzy system. Humidity was only considered as a load. The experimental results showed that the controlled temperature of exhausted air was maintained at 8$\pm$2$\^{C}$. Relative humidity of the air was also controlled at the target relative humidity of 50∼80%.