• Title/Summary/Keyword: Cold Air Flow

Search Result 310, Processing Time 0.026 seconds

Development of High-performance/low-noise Centrifugal Fan Circulating Cold Air Inside a Household Refrigerator by Reduction of Vortex Flow (와류 저감을 통한 냉장고 냉기순환용 고성능/저소음 원심홴의 개발)

  • Shin, Donghui;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-Hoon;Jung, Jiwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.428-435
    • /
    • 2016
  • In this paper, high-performance and low-noise centrifugal fan used to circulate cold air inside a household refrigerator is developed by reducing the vortex flow observed near the tip of fan hub. First, the performance of the existing centrifugal fan is investigated through the experiment using a fan tester and the characteristics of detailed flow field obtained from the CFD simulation are closely examined. The strong vortex flow is observed in the vicinity of the tip of fan hub. Based on this result, new design is devised to reduce this vortex flow. As a result, it is numerically and experimentaly found that the volume flow rate of the new fan increases and the radiated noise decreases in comparison with the existing fan at the same rotation speed.

Management Planning of Wind Corridor based on Mountain for Improving Urban Climate Environment - A Case Study of the Nakdong Jeongmaek - (도시환경개선을 위한 산림 기반 바람길 관리 계획 - 낙동정맥을 사례로 -)

  • Uk-Je SUNG;Jeong-Min SON;Jeong-Hee EUM;Jin-Kyu MIN
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.1
    • /
    • pp.21-40
    • /
    • 2023
  • This study analyzed the cold air characteristics of the Nakdong Jeongmaek, which is advantageous for the formation of cold air that can flow into the city, in order to suggest the wind ventilation corridor plans, which have recently been increasing interest as a way to improve the urban thermal environment. In addition, based on the watershed analysis, specific cold-air watershed areas were established and management plans were suggested to expand the cold air function of the Nakdong Jeongmaek. As a result of the analysis of cold air in the Nakdong Jeongaek, cold air was strongly generated in the northern forest of the Jeongamek, and flowed into nearby cities along the valley topography. On average, the speed of cold air was high in cities located to the east of the Jeongmaek, while the height of cold air layer was high in cities located to the west. By synthesizing these cold air characteristics and watershed analysis results, the cold-air watershed area was classified into 8 zones, And the plans were proposed to preserve and strengthen the temperature reduction of the Jeongmaek by designating the zones as 'Conservation area of Cold-air', 'Management area of Cold-air', and 'Intensive management area of Cold-air'. In addition, in order to verify the temperature reduction of cold air, the effect of night temperature reduction effect was compared with the cold air analysis using weather observation data. As a result, the temperature reduction of cold air was confirmed because the night temperature reduction was large at the observation station with strong cold air characteristics. This study is expected to be used as basic data in establishing a systematic preservation and management plan to expand the cold air function of the Nakdong Jeongmaek.

Optimization of Atmospheric Cold Plasma Treatment with Different Gases for Reduction of Escherichia coli in Wheat Flour

  • Lee, Jeongmin;Park, Seul-Ki;Korber, Darren;Baik, Oon-Doo
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.6
    • /
    • pp.768-775
    • /
    • 2022
  • In this study we aimed to derive the response surface models for Escherichia coli reduction in wheat flour using atmospheric cold plasma (ACP) with three types of gas. The jet-type atmospheric cold plasma wand system was used with a 30 W power supply, and three gases (argon, air, and nitrogen) were applied as the treatment gas. The operating parameters for process optimization considered were wheat flour mass (g), treatment time (min), and gas flow rate (L/min). The wheat flour samples were artificially contaminated with E. coli at a concentration of 9.25 ± 0.74 log CFU/g. ACP treatments with argon, air, and nitrogen resulted in 2.66, 4.21, and 5.55 log CFU/g reduction of E. coli, respectively, in wheat flour under optimized conditions. The optimized conditions to reduce E. coli were 0.5 g of the flour mass, 15 min of treatment time, and 0.20 L/min of nitrogen gas flow rate, and the predicted highest reduction level from modeling was 5.63 log CFU/g.

A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store (CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구)

  • Cho Sung Woo;Park Min Young;Im Young Bin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed $10\%$ near the refrigeration zone and $8.8\%$ near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed $6.8^{\circ}C\;and\;3.9^{\circ}C$ with diffuser air temperature $17^{\circ}C$ and were showed $6.8^{\circ}C$ and $4^{\circ}C$ with diffuser air temperature $19^{\circ}C$.

A Cold Flow Experiment for the Incinerator Shape Design (소각로의 형상설계를 위한 냉간유동실험)

  • 류창국;김숭기;최상민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2184-2193
    • /
    • 1994
  • A flow visualization experiment using water-table models was performed. The water-table models simulated the two-dimensional cold flow fields inside the combustion chambers of incinerators. The flow were visualized by small but neutrally bouyant particles photographed by an overhead camera. The experimentally simulated flow fields apparently showed distinct features of two combustion chamber shapes; counter and parallel flow types. The significance of the secondary air injection on the mixing of combustion gases were clearly observed. The effects of the recirculation zones, which were present in the secondary chamber, were discussed by considering the importance of them for optimal combustion.

3-D Simulation of Air Flow in Cold Storage Room for Uniform Temperature Distribution (저온저장고 내부의 균일한 온도분포를 위한 3차원 공기유동 분석)

  • 성제중;고학균;조성인;양길모
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.279-286
    • /
    • 2000
  • Most of the domestic cold storage rooms are inefficient for agricultural products because of temperature gradients inside the storage rooms. Temperature gradients are developed mainly by improper airflow pattern inside the storage room, which is a main cause of the spoilage of the agricultural products. There proper airflow pattern is essential to minimize these temperature gradients and the spoilage. The performance and characteristics of a cold storage room were determined as a function of airflow pattern and temperature distribution in forced circulation cold storage room. A commercial CFD(computational fluid dynamics) code was used to simulate 3-D airflow in the cold storage room. Solving the flow equations for the storage room, a standard k-$\varepsilon$ turbulent model was implemented to calculate steady state turbulent velocity distribution. The CFD prediction results were compared with temperature measurements inside the cold storage room. In case of pallet storage, Temperature gradients inside pallet storage was reduced because the contact area of cold air expanded through an alley of airflow in storage. But is case of bulk storage, the last temperature of storage considerably rose more than the initial temperature of storage. The reason was that bulk storage didn't include any alley of airflow in storage.

  • PDF

Studies on Zone Cooling of Greenhouse in the Daytime in Summer and Occurrence of Blossom - End Rot in Tomato Plants (하기주간의 국소냉방과 토마토 배꼽썩음병 발생에 관한 연구)

  • 조일환;우영회;인과홍중;교본강
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.36-41
    • /
    • 1994
  • The major objective of this study is to develop a method of zone cooling during summer day using heat pump for year- round cultivation. The efficiency of cold water cooling and fog cooling was investigated. In order to prevent the occurrence of blossom - end rot in tomato, cooling was induced together with air flow of the fruit treatment as well as promoting air circulation in the plant treatment was induced. The following results were obtained : 1) The temperature in the cold water cooling district was 1$0^{\circ}C$ lower than greenhouse temperature and the temperature in the fo8 cooling district was about 5$^{\circ}C$ lower than the greenhouse. 2) Regardless of cooling method, the treatment of air flow on fruit did not affect the fruit but prevent blossom-end rot. There was 34.5% occurrence rate of blossom -end rot in non-air flow district of cold water cooling 54.5% in non-air flow district of fog cooling and 78% in fog circulation cooling district. The cooling efficiency using cold water cooling method induced enough cooling at critical temperature for growth and development and the occurrence of blossom -end rot was lower than fog cooling. Fog cooling in culture district with air circulation did not induce and difference in temperature but caused an Increase in humidity resulting in 24% increase in the occurrence of blossom-end rot. Thus the occurrence of blossom-end rot in tomato caused by environmental factors can be attributed more to humidity than to temperature.

  • PDF

Classification of Wind Corridor for Utilizing Heat Deficit of the Cold-Air Layer - A Case Study of the Daegu Metropolitan City - (냉각에너지를 활용한 바람길 구성요소 분류 - 대구광역시를 사례로 -)

  • Sung, Uk-Je;Eum, Jeong-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.5
    • /
    • pp.70-83
    • /
    • 2023
  • Recently, the Korea Forest Service has implemented a planning project about wind corridor forests as a response measure to climate change. Based on this, research on wind corridors has been underway. For the creation of wind corridor forests, a preliminary evaluation of the wind corridor function is necessary. However, currently, there is no evaluation index to directly evaluate and spatially distinguish the types of wind corridors, and analysis is being performed based on indirect indicators. Therefore, this study proposed a method to evaluate and classify wind corridors by utilizing heat deficit analysis as an evaluation index for cold air generation. Heat deficit was analyzed using a cold air analysis model called Kaltluftabflussmodell_21 (KLAM_21). According to the results of the simulation analysis, the wind path was functionally classified. The top 5% were classified as cold-air generating Areas (CGA), and the bottom 5% as cold-air vulnerable Areas (CVA). In addition, the cold-air flowing Areas (CFA) were classified by identifying the flow of cold air moving from the cold air generation area. It is expected that the methodology of this study can be utilized as an evaluation method for the effectiveness of wind corridors. It is also anticipated to be used as an evaluation index to be presented in the selection of wind corridor forest sites.

Numerical Analysis of Single Phase Thermal Stratification in both Cold Legs and Downcomer by Emergency Core Cooling System Injection : A Study on the Necessity to Consider Buoyancy Force Term (비상노심냉각계통 주입에 따른 저온관 및 강수관에서 단상 열성층 수치해석 : 부력항 고려 필요성에 관한 연구)

  • Lee, Gong Hee;Cheong, Ae Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.12
    • /
    • pp.654-662
    • /
    • 2017
  • When emergency core cooling system (ECCS) is operated during loss of coolant accident (LOCA) in a pressurized water reactor (PWR), pressurized thermal shock (PTS) phenomenon can occur as cooling water is injected into a cold leg, mixed with hot primary coolant, and then entrained into a reactor vessel. Insufficient flow mixing may cause temperature stratification and steam condensation. In addition, flow vibration may cause thermal stresses in surrounding structures. This will reduce the life of the reactor vessel. Due to the importance of PTS phenomenon, in this study, calculation was performed for Test 1 among six types of OECD/NEA ROSA tests with ANSYS CFX R.17. Predicted results were then compared to measured data. Additionally, because temperature difference between the hot coolant at the inlet of the cold leg and the cold cooling water at the inlet of the ECCS injection line is 200 K or more, buoyancy force due to density difference might have significant effect on thermal-hydraulic characteristics of flow. Therefore, in this study, the necessity to include buoyancy force term in governing equations for accurate prediction of single phase thermal stratification in both cold legs and downcomer by ECCS injection was numerically studied.

Modeling of Liquid Fuel Behavior to Control Air/Fuel Ratio in the Intake Port of SI Engines (가솔린 기관 공연비 제어를 위한 흡기포트 내의 연료액막 모델링)

  • Cho, Hoon;Min, Kyoung-Doug;Hwang, Seung-Hwan;Lee, Jong-Hwa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.512-518
    • /
    • 2000
  • A wall fuel-film flow model is developed to predict the effect of a wall-fuel-film on air-fuel ratio in an SI engine in transient conditions. Fuel redistribution in the intake port resulting from charge backflow and a simple liquid fuel behavior in the cylinder are included in this model. Liquid fuel film flow is calculated of every crank angle degree using the instantaneous air flow rate. The model is validated by comparing the calculated results and corresponding engine experiment results of a commercial 4 cylinder DOHC engine. The predicted results match well with the experimental results. To maintain the constant air-fuel ratio during transient operation. the fuel injection rate control can be obtained from the simulation result.