• Title/Summary/Keyword: Cold Air

Search Result 1,226, Processing Time 0.027 seconds

냉기침강효과를 고려한 복잡지형의 최저기온 분포 추정 (Minimum Temperature Mapping in Complex Terrain Considering Cold Air Drainage)

  • 정유란;서형호;황규홍;황범석;윤진일
    • 한국농림기상학회지
    • /
    • 제4권3호
    • /
    • pp.133-140
    • /
    • 2002
  • Site-specific minimum temperature forecasts are critical in a short-term decision making procedure for preventive measures as well as a long-term strategy such as site selection in fruits industry. Nocturnal cold air pools frequently termed in mountainous areas under anticyclonic systems are very dangerous to the flowering buds in spring over Korea, but the spatial resolution to detect them exceeds the current weather forecast scale. To supplement the insufficient spatial resolution of official forecasts, we developed a GIS - assisted frost risk assesment scheme for using in mountainous areas. Daily minimum temperature data were obtained from 6 sites located in a 2.1 by 2.1 km area with complex topography near the southern edge of Sobaek mountains during radiative cooling nights in spring 2001. A digital elevation model with a 10 m spatial resolution was prepared for the entire study area and the cold air inflow was simulated for each grid cell by counting the number of surrounding cells coming into the processing cell. Primitive temperature surfaces were prepared for the corresponding dates by interpolating the Korea Meteorological Administration's automated observational data with the lapse rate correction. The cell temperature values corresponding to the 6 observation sites were extracted from the primitive temperature surface, and subtracted from the observed values to obtain the estimation error. The errors were regressed to the flow accumulation at the corresponding cells, delineating a statistically significant relationship. When we applied this relationship to the primitive temperature surfaces of frost nights during April 2002, there was a good agreement with the observations, showing a feasibility of site-specific frost warning system development in mountainous areas.

제주도 감귤 과수원의 야간 기온 분포(II) (Nocturnal temperature distribution on orange orchards in Cheju Island (II))

  • 이승호;이현영
    • 대한지리학회지
    • /
    • 제30권3호
    • /
    • pp.230-241
    • /
    • 1995
  • 제주도에서 때때로 밭생하는 동해(凍害) 는 감귤 농사에 많은 영향을 준다. 특히 한 라산 북사면의 감귤 과수원에서는 대규모의 동해 뿐만 아니라 소규모 냉기류의 정체로 인하 여 품질과 생산성이 낮아지는 경우가 빈번하다. 본 연구는 감귤 과수원지역의 동해나 한해 (寒害)로 인한 피해 방지를 모색하기 위한 연구의 일환으로서 1989-1990년 겨울에 동해 피 해가 컸던 북제주군 와산리 일대를 사례로 택한 1995년 1월 관측 결과를 중심으로 기온 분 포의 특성을 분석하였다. 기상조건에 따라서 고지대(해발 200m 이상의 지역)와 저지대(해발 200m미만의 지역)의 최저기온 분포가 다르게 나타났다. 흐리고 바람이 강한 날과 강수현상 이 있는 날에는 고지대의 기온이 낮은데, 저지대와의 차이는 전자의 경우 2.4$^{\circ}C$, 후자의 경 우 0.2$^{\circ}C$ 정도이다. 반면 바람이 없고 맑은 날 야간에는 저지대보다 고지대의 기온이 높은데 최대 차이는 4.8$^{\circ}C$에 달하였다. 방풍 시설에 의하여 밀폐된 곳이나 지형적으로 함몰된 와지 에서는 냉기류가 정체되면서 소규모의 냉기호가 형성되었다. 그리고 최대 강도 3.1$^{\circ}C$ 에 이 르는 지표면의 복사냉각에 의한 기온 역전 현상이 발생하는데, 방풍시설로 완전히 밀폐된 고도인 90cm까지 뚜렷하게 저온현상이 나타났다. 방풍림과 방풍담으로 밀폐된 곳에서는 방 풍 시설의 전면과 후면의 기온차가 2.O$^{\circ}C$에 이르고 있다. 저지대에 냉기호가 형성되었을 경 우, 인공적으로 소규모의 대류현상을 일으켜 냉기호 내의 기온을 상승시키는대 큰효과를 얻 을 수 있었다. 본 연구의 결과는 실측에 의한 상습 냉해지역의 파악과 냉해 방지를 위한 합 리적인 방풍시설의 설계의 방요성이 시급함을 보여준다.

  • PDF

서버 컴퓨터의 발열량이 변화한 경우의 데이터센터 내의 기류 및 온도분포 특성에 대한 연구 (A Study on the Distribution of Airflow and Temperature in a Data center under the Various Conditions of Heat Generation Rates of Server Computers)

  • 장현재;김제영
    • 설비공학논문집
    • /
    • 제26권3호
    • /
    • pp.108-114
    • /
    • 2014
  • On a large scale of data center, heat generation rates from sever computers occupy almost the entire cooling load of the building, and it is gradually increasing. The efficiency of air distribution system in data centers can be affected by heat generation rates of server computers. In this study, the distributions of airflow and temperature in a data center have been investigated by CFD simulations under various conditions of heat generation rates for server computers. From the results, air around the cold aisle which has high temperature flows tremendously into the cold aisle according to the increase of heat generation rates for server computers and the air temperature in the cold aisle becomes higher. The SHI (supply heat index) and RHI (return temperature index) show almost similar values to the cases study because the air inflow rates to server computers increase with the heat generation rates of server computers.

곡물빈용 공기조화장치의 퍼지제어기 개발 (Development of Fuzzy Controller for Air Conditioning of Grain Bin)

  • 최영수;문대식;정종훈
    • 한국식품저장유통학회지
    • /
    • 제9권2호
    • /
    • pp.137-143
    • /
    • 2002
  • Temperature and humidity are the most important factors and should be effectively controlled for the cold storage of graius. Fuzzy logic can be easily implemented to the MIMO(Multi-Input Multi-Output) control systems. For the cold storage in grain bin, fuzzy logic was applied to an air conditioning system. The capacities of the grain bin and the air conditioner are 80 tons and 30㎾, respectively. Also, the target values of temperature and relative humidity in outlet duct of the air conditioner were 8$\^{C}$ and 75%, respectively. In order to control temperature and relative humidity of air, a damper in inlet duct was manipulated for temperature control and a heater was used for humidity control. Temperature deviation and change of temperature deviation were used as input parameters for the fuzzy system. Humidity was only considered as a load. The experimental results showed that the controlled temperature of exhausted air was maintained at 8$\pm$2$\^{C}$. Relative humidity of the air was also controlled at the target relative humidity of 50∼80%.

한국 남동연안의 냉수대 영향에 의한 해풍순환과 오존농도의 사례연구 (A Case Study on Sea Breeze Circulation and Ozone Concentration due to the Effect of Cold Water in the Southeastern Coastal Area of Korea)

  • 지효은;이순환;박창현;이화운
    • 한국환경과학회지
    • /
    • 제23권2호
    • /
    • pp.261-274
    • /
    • 2014
  • This work investigates the relationship between the sea breeze circulation and ozone concentrations during cold water events in the southeastern coastal area of the Korean Peninsula, where coastal upwelling frequently occur. This analysis was performed based on the classification of two categories, such as cold water and non-cold water events, over the period of 2000-2009. The low air temperature ($0.5^{\circ}C$), low SST ($5^{\circ}C$) and the wind direction(southerly) are the features of the cold water events in the Southeastern coastal area. Moreover, ozone concentrations in the cases of the sea breeze circulation and cold water events were significantly lower (below 30 ppb) than those (70~100 ppb) in the non-clod water events, because of the low air temperature ($10{\sim}20^{\circ}C$) and high wind speed (3~5 m/s) around the southeastern coastal area.

관측과 모델 자료를 활용한 겨울철 영동지역 한기 축적(Yeongdong Cold Air Damming; YCAD)의 공간 규모 분석 (An Analysis on the Spatial Scale of Yeongdong Cold Air Damming (YCAD) in Winter Using Observation and Numerical Weather Model)

  • 남형구;정종혁;김현욱;심재관;김백조;김승범;김병곤
    • 대기
    • /
    • 제30권2호
    • /
    • pp.183-193
    • /
    • 2020
  • In this study, Yeongdong cold air damming (YCAD) cases that occur in winters have been selected using automatic weather station data of the Yeongdong region of Korea. The vertical and horizontal scales of YCAD were analyzed using rawinsonde and numerical weather model. YCAD occurred in two typical synoptic patterns such that low pressure and trough systems crossing and passing over Korea (low crossing type: LC and low passing type: LP). When the Siberian high does not expand enough to the Korean peninsula, low pressure and trough systems are likely to move over Korea. Eventually this could lead to surface temperature (3.1℃) higher during YCAD than the average in the winter season (1.6℃). The surface temperature during YCAD, however, was decrease by 1.3℃. The cold air layer was elevated around 120 m~450 m for LP-type. For LC-type, the cold layer were found at less than approximately 400 m and over 1,000 m, which could be thought of combined phenomena with synoptic and local weather forcing. The cross-sectional analysis results indicate the accumulation of cold air on the east mountain slope. Additionally, the north or northeasterly winds turned to the northwesterly wind near the coast in all cases. The horizontal wind turning point of LC-type was farther from the top of the mountain (52.2 km~71.5 km) than that of LP-type (20.0 km~43.0 km).

공동주택용 하이브리드 환기설비에 관한 연구 (A Study of Hybrid Ventilation System applying to an Apartment House)

  • 이성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1137-1143
    • /
    • 2006
  • The purpose of this research lays on examining the adequacy of the hybrid ventilation system. The hybrid ventilation system must satisfy the next to be used. Firstly, the cold-draft phenomenon must not exist in the occupied zone. Secondly, the condensation must not happen on the surfaces of vents. Thirdly, the flow of make-up air must be happened in an each space by exhausted air of a rest room and living room. We used an examination and CFD method to verify these. Trough the examination of air-vents, We confirmed that the cold-draft to be induced by make-up air does not happen and could not find the condensation in the limits of outdoor temperature higher than 265K. Through CFD simulation, We confirmed that the rapid temperature change existed only within 0.5m the occupied zone and the flow of air was happened in an each space by only exhausted air in the rest room and living room. Consequently, the hybrid system is possible method to an apartment house.

  • PDF

로봇 냉각을 위한 수냉식 냉각판의 성능 평가 (Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling)

  • 이석원;강상우;황규대;김서영;리광훈
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.189-196
    • /
    • 2008
  • The increase of system weight due to installation of cooling devices adds electrical and mechanical loads of humanoid robot, and in return, results in much heat. Therefore, the weight of cooling system is a critical issue for robot cooling. In this study, we propose non-metallic cold plates to deal with such problems. We compare thermal performances between one metallic cold plate and five different types of non-metallic cold plates. A metallic cold plate is totally made of copper. Five non-metallic PC(polycarbonate) cold plates, which are designed to reduce the overall weight of robot cooling system, are composed of a polycarbonate cover with different types of base plate. The overall heat transfer coefficients per unit mass and thermal resistances are obtained for the cold plates. The metallic cold plate shows the best thermal performance. It is interesting to note that the PC cold plate with an aluminum base plate with 18 channels shows the best overall heat transfer coefficient per unit mass. Most polycarbonate cold plates display fairly comparable thermal performance with more reduced system weight compared to the metallic cold plate.

냉각액 최소화를 통한 환경 친화적 연삭 가공기술 연구 (A Study on the Environment-Friendly Grinding Technology through Minimizing Coolant)

  • 최헌종;이석우;김대중;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.796-799
    • /
    • 2000
  • The concern of environmental problems by using coolant required the recycling technologies of used coolant and development of environmental-firiendly coolant Some methods have been developing. Those are the dry grinding with compressed cold air and grinding with misted coolant. The farmer is effective in the cooling effect, but has not the performance of lubrication. Otherwise, the latter can satisfy both of them and also decrease the environmental pollution. This paper tried to analyze the cooling effect and surface integral of coolant, compressed cold air, mist through measuring the temperature of grind point and grinding force. Especially, the grinding method with misted coolant according to parameters was done. So, the finding method with misted coolant proved to be effective as one of methods to decrease the environmental pollution.

  • PDF

가시화 기법을 이용한 열전소자 냉장고의 유동최적화에 관한 연구 (A Study on flow optimization of thermoelectric refrigerator using visualization technique)

  • 김보라;이창제;정연호;황광일;조경래
    • 한국가시화정보학회지
    • /
    • 제19권1호
    • /
    • pp.94-99
    • /
    • 2021
  • In order to increase the efficiency of thermoelectric refrigerators using the Peltier effect, it is necessary to optimize the distribution of the flow of cold air from the fan. In this study, the flow flowing upwards and downwards while changing the area of the flow path was visualized using the PIV technique for the control of cold air in a thermoelectric refrigerator. From these results, the flow rate according to the change in the area of the flow path was confirmed, and design criteria for optimizing the distribution of cold air flowing to the top and bottom of the refrigerator were suggested.