• Title/Summary/Keyword: Coincident

Search Result 505, Processing Time 0.025 seconds

FUZZY SUBALGEBRAS WITH THRESHOLDS IN BCK/BCI-ALGEBRAS

  • Jun, Young-Bae
    • Communications of the Korean Mathematical Society
    • /
    • v.22 no.2
    • /
    • pp.173-181
    • /
    • 2007
  • Using the belongs to relation ($\in$) and quasi-coincidence with relation (q) between fuzzy points and fuzzy sets, the concept of ($\alpha,\;\beta$)-fuzzy subalgebras where $\alpha,\;\beta$ are any two of $\{{\in},\;q,\;{\in}\;{\vee}\;q,\;{\in}\;{\wedge}\;q\}$ with ${\alpha}\;{\neq}\;{\in}\;{\wedge}\;q$ was introduced, and related properties were investigated in [3]. As a continuation of the paper [3], in this paper, the notion of a fuzzy subalgebra with thresholds is introduced, and its characterizations are obtained. Relations between a fuzzy subalgebra with thresholds and an (${\in},\;{\in}\;{\vee}\;q$)-fuzzy subalgebra are provided.

Simultanceous Saccharification and Fermentation of Cellulose for Lactic Acid Production

  • Yoon, Hyon-Hee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.2 no.2
    • /
    • pp.101-104
    • /
    • 1997
  • Lactic acid production from ${\alpha}$-cellulose by simultaneous saccharification and fermentation (SSF) was studied. The cellulose was converted in a batch SSF using cellulase enzyme Cytolase CL to produce glucose sugar and Lactobacillus delbrueckii to ferment the glucose to lactic acid. The effects of temperature, PH, yeast extract loading, and lactic acid inhibition were studied to determine the optimum conditions for the batch processing. Cellulose was converted efficiently to lactic acid, and enzymatic hydrolysis was the rate controlling step in the SSF. The highest conversion rate was obtained at 46$^{\circ}C$ and pH 5.0. The observed yield of lactic acid from ${\alpha}$-cellulose was 0.90 at 72 hours. The optimum pH of the SSF was coincident with that of enzymatic hydrolysis. The optimum temperature of the SSF was chosen as the highest temperature the microoraganism could withstand. The optimum yeast extract loading was found to be 2.5g/L. Lactic acid was observed to be inhibitory to the microorganisms' activity.

  • PDF

Study on Electro-optic Characteristics of Fringe-field Switching Twisted Nematic Mode using a Liquid Crystal with Negative Dielectric Anisotropy (유전율 이방성이 음인 액정을 이용한 Fringe-field Switching Twisted Hematic 모드의 전기광학 특성 연구)

  • 송일섭;신성식;이종문;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.530-535
    • /
    • 2004
  • We have studied 90$^{\circ}$ twisted nematic mode switching by fringe electric field(F-TN mode) using a liquid crystal (LC) with negative dielectric anisotropy. In the device, two polarizers are parallel each other, electrodes exist only on bottom substrate, and one of rubbing direction is coincident with polarizer axis. Therefore, the cell shows a black state before a voltage is applied. With a bias voltage generating fringe-electric field, the LC twists perpendicular to fringe electric field such that the LCs are almost homogeneously aligned except near the bottom surface since the negative type of the LC is used. Consequently, the new device exhibits much wider viewing angle than that of the conventional TN mode due to in-plane switching and relatively high transmittance since the LC director above whole electrode area aligns parallel to the polarizer axis.

A Study on the Development of the Side Load Coil Spring (횡력발생 코일스프링 설계 및 제조에 관한 연구)

  • Kwon, H. H.;Choi, S. J.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.5
    • /
    • pp.98-105
    • /
    • 1998
  • In the automotive suspension system, especially, Mcpherson strut type, if the resultant of the force through tire and the link reaction force is not coincident with the spring force, the side load against shock-absorber occur. The magnitude of side load is proportional to the difference between resultant force and spring force. To reduce side load, several method can be used, and one is to use the side load coil spring. This study summarize the development results of side load coil spring, i.e., how to design, analysis, manufacture, and test.

  • PDF

Analysis and Prediction of Structural Vibration for Diesel Engine Generator Set (디젤 발전기세트의 구조진동특성 연구)

  • 이수목;김관영;김원현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.948-954
    • /
    • 2002
  • The structural vibration of a diesel generator set was investigated through analyses and tests. FE modeling and normal mode analysis were performed and compared with measured results for both structure components and generator set assembly. The results of component analyses were fairly well coincident with measured results but those of assembled generator set showed more or less discrepancies. Discussions were given about the uncertainties for vibration characteristics of component structures and assembled running structures especially concerning their nonlinearities and damping effects. Detailed excitation analysis fellowed by forced response analysis was done from the engine and pressure data to compare with the actual measured vibration. As results the vibration prediction for frame structures of reciprocating internal combustion engine was confirmed reliable to some extent.

  • PDF

Sound Intensity Estimation with the Effect of Leakage Error from the Contaminated Data (누설오차의 영향을 고려한 음향 인텐시티의 추정)

  • 안세진;정의봉;정호경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1189-1194
    • /
    • 2002
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent micrphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional r]n analyzer will show distorted value. In this paper the expression of the Fourier transformed data of a harmonic signal is formulated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

원격어군탐지기의 시작 및 그 응용에 관한 연구 ( 1 ) - 시스템 시뮬레이션 - ( Study on the Trial Manufacture of Telesounder and its Application ( 1 ) - System Simulation - )

  • 이원우
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.135-141
    • /
    • 1994
  • In order to investigate remotely the behavior and distribution of fishes, the telesounder system which was composed of two parts with a buoy station at sea and a base station on land was manufactured trial. The buoy station at sea consists of fishfinder, transmission interface and transceiver. On the other hand, the base station on land consist of transceiver, receiving interface, trigger/signal separator and color display monitor. The system simulation for the performance of telesounder was carried out by use of echo simulator which could input echo signal into fishfinder. The received power (dBm) of transceiver at 29.4MHz decreased almost in proportion to distance between transmitter and receiver, and the electric field intensity was 12.12mV/m at 100 meters distance from transmitter. The image of color display monitor at the base station on land was very well coincident with the records of fishfinder from the buoy station located at sea. Therefore, it is concluded that the telesounder system is very useful in the analysis of the information on the behavior and the distribution of fishes detected from sea.

  • PDF

An analysis for the deflection profile of MCFC shield-slot plate by gravity (연료전지용 쉴드슬롯판의 자중처짐해석)

  • Shim U. T.;Lee K. S.;Woo D. W.;Kim J. Y.;Kim J. H.;Lee S. W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.472-475
    • /
    • 2005
  • In this study, the equivalent physical properties of the shield-slot plate that has a lot of very tiny bridge shape structures on its plane were determined by tensile tests and structural analyses. With those results in hand, numerical analyses for the deflection profile by gravity effect were carried out to compare with experimental results. The two results were shown coincident very well so that the estimated equivalent physical properties were verified enough for further studies such as curvature reduction for the shield-slot plate.

  • PDF

Coincident finding of bronchopneumonia by Pasteurella multocida, Bordetella bronchiseptica and Klebsiellosis in muskrat (사향쥐에서 Pasteurella multocida 및 Bordetella bronchiseptica에 의한 bronchopneumonia와 Klebsiellosis의 동시감염 증례)

  • Park, Mi-Young;Jeon, Oh-Sook;Cho, Yun-Kyoung;Choi, Kyung-Mook;Woo, Jong-Tae
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.2
    • /
    • pp.165-169
    • /
    • 2009
  • Suppuratives bronchopneumonia was found in a 3-month old domestic muskrat (Ondatra zibethicus). Dead muskrat showed hemorrhagic nasal discharge, severe hemorrhage and consolidation were observed in the lungs in necropsy. Histologically, severe polymorphic neutrophils and alveolar macrophages were infiltrated in the bronchus, bronchioles, alveoli. P. multocida and B. bronchiseptica were identified from the lungs, Klebsiella was isolated from the cecum. We demonstrated those organisms by biochemical test and confirmed P. multocida capsular type A by means of polymerase chain reaction (PCR).

Determination of Hypocenter Parameters Using a Personal Computer (개인용 컴퓨터에 의한 지진의 진원인자 결정)

  • Kim, So Gu;Kim, Tae Woo
    • Economic and Environmental Geology
    • /
    • v.25 no.3
    • /
    • pp.359-365
    • /
    • 1992
  • The parameters of the Korean earthquake have been determined by the manual method, which results in consuming more time and more errors. In this study we used HYPO71PC to determine earthquake parameters and to identify unknown active faults and lineaments in South Korea. The epicenters determined by the new computer technique are almost identical with the manual method of Korea Meteorological Agency. It is also found that most of epicenters are coincident with unknown faults that are defined as the un-determined faults on the tectonic map of Korea, and/or structural lineaments in South Korea.

  • PDF