• Title/Summary/Keyword: Coil type

Search Result 816, Processing Time 0.023 seconds

Evaluation of Exposure to Indoor Volatile Organic Compounds by Utilizing Emission Characteristics and Emission Factor of Household Mosquito Repellents (가정용 모기살충제의 배출 특성 및 배출계수를 이용한 실내 휘발성 유기화합물질 노출 평가)

  • Jo, Wan-Kuen;Lee, Jong-Hyo
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1123-1134
    • /
    • 2009
  • This study was designed to evaluate qualitatively and quantitatively the pollutant compositions, which were emitted from three types of mosquito repellents(MRs)(mat-, liquid-vaporized, and coil-type) by utilizing a 50-L environmental chamber. A qualitative analysis revealed that 42 compounds were detected on the gas chromatography/mass spectrometer system, and that the detection frequency depended upon chemical types. Nine of the 42 compounds exhibited a detection frequency of 100%. Four aromatic compounds(benzene, ethyl benzene, toluene, and xylene) were detected in all test MRs. The concentration equilibriums in the environmental chamber were achieved within 180 min after sample introduction. The coil-type MR represented higher chamber concentrations as compared with the mat- or liquid-vaporized-type MR, with respect to the target compounds except for naphthalene. In particular, the chamber concentrations of ethyl benzene, associated with the use of coil-type MR, were between 0.9 and $65\;mg\;m^{-3}$ whereas those of mat- and liquid-vaporized-type MRs we~e between 0.5 and $2.0\;mg\;m^{-3}$and 0.3 and $1.4\;mg\;m^{-3}$, respectively. However, naphthalene concentrations in the chamber, where a liquid-vaporized-type MR was placed, were measured as between 17.8 and $56.3\;mg\;m^{-3}$, but not detected in the chamber, where a mat- or coil-type MR was placed. The empirical model fitted well with the time-series concentrations in the environmental chamber(in most cases, determination coefficient, $R^2$ ≿ 0.9), thereby suggesting that the model was suitable for testing emissions. In regards to the target compounds except for benzene, although they were emitted from the MRs, health risk from individual exposure to them were estimated not to be significant when comparing exposure levels with no observed adverse exposure levels or lowest observed adverse exposure levels of corresponding compounds. However, it was concluded that the use of MRs could be an important indoor source as regards benzene.

Characteristic of Moving Coil type Linear Oscillatory Actuator by Multi-Pole Permancent Magnet Arrangement (영구자석 다극 배치에 의한 가동 코일형 리니어 진도 엑츄에이터의 특성)

  • 김덕현;강규홍;홍정표;김규탁
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.273-281
    • /
    • 2001
  • In order to overcome the demerit and to improve the operation characteristics of Moving Coil type Linear Oscillatory Actuator(MC-LOA) with single-pole permanent magnet, this paper presents two models having the balanced magnetic circuit by multi-pole permanent magnet. They are short coil type with two-pole single-sided and two-ple double-sided permanent magnet. The characteristics between single-pole and multi-pole permanent magnet type MC-LOA are compared. As a result, multi-pole type MC-LOA has more merits than single-pole type about operation characteristics improvement and machine volume. The characteristics analysis is performed by their dynamic analysis composed of kinetic and electric equations and Finite Element Method(FEM). The propriety of multi-pole type MC-LOA model is verified with analysis results.

  • PDF

Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL (분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.

Experimental Study on Compact type CO2 Gas Cooler(1) - Heat Flowrate and Pressure Drop in a Multi-Tube-In-Tube Helical Coil Type Gas Cooler - (CO2 가스쿨러용 콤팩트열교환기 개발에 관한 연구(1) -다중관식 헬리컬 코일형 가스냉각기내 CO2의 열유량과 압력강하-)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.30-36
    • /
    • 2010
  • The heat flowrate and pressure drop of $CO_2$ in a multi-tube-in-tube helical coil type gas cooler were investigated experimentally. The mass flowrate of $CO_2$ and coolant were varied from 0.06 to 0.075 [kg/s], respectively and the cooling pressure of gas cooler were from 8 to 10 [MPa]. The heat flowrate of $CO_2$ in the test section is increased with the increase in mass flowrate of coolant, the cooling pressure and mass flowrate of $CO_2$. The pressure drop of $CO_2$ is decreased with the decrease in mass flowrate of coolant and $CO_2$, but decreased with increase in cooling pressure of $CO_2$. The heat flowrate of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly higher than that of $CO_2$ in the double pipe type gas cooler, while the pressure drop of $CO_2$ in the multi-tube-in-tube helical coil type gas cooler is greatly lower than that of $CO_2$ in the double pipe type gas cooler. Therefore, in case of the application of $CO_2$ at the multi-tube-in-tube helical coil type gas cooler, it is expected to carry out the high-efficiency, high-performance and compactness of gas cooler.

Feasibility Study of Coil Gun Type Actuator for High Voltage Circuit Breaker (초고압 차단기용 코일건 타입 조작기의 기술적 타당성 검토)

  • Cho, Chu-Hyun;Lee, Hong-Sik;Kim, Seog-Whan;Kim, Young-Bae;Lee, Woo-Young;Kim, Hong-Kyu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.7
    • /
    • pp.367-372
    • /
    • 2006
  • A novel coil gun type actuator has been proposed and tested for its possibility as an actuator for a high voltage circuit breaker by experimental method. The 20kJ capacitor bank with the electrolytic condensers was charged up to 500V and discharged to a couple of 100 turn coils connected with parallel through a thyristor switch. The repulsive force between coil and the actuator made by copper conductor of 20kg reached up to 23,000 N, and over 800J of energy was transferred to the kinetic energy of the conductor. The experimental results showed that the coil gun type actuator has a good possibility for the high voltage circuit breaker.

A Study on the Ice-on-coil as a Static Ice Making Type (정적제빙형인 관외 제빙에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.292-298
    • /
    • 2008
  • This study was experimentally investigated to understand the ice making characteristics of ice on a coil type ice maker. The experiment was carried out under the following conditions which are the brine temperatures of $-10[^{\circ}C],\;-8[^{\circ}C],\;-6[^{\circ}C]$, brine flow velocities of 1.0[m/s], 1.4[m/s], 1.8[m/s] and initial water temperatures of $6[^{\circ}C],\;9[^{\circ}C],\;12[^{\circ}C]$, ect. The acquired conclusions shows: 1) Ice making amount is increased with decreasing in the temperature of brine. 2) Total ice making amount shows higher value in larger size coil. However, the ice making amount per heat transfer area is increased in smaller one. 3) The ice making amount is increased with decreasing in the initial water temperature. 4) It is cleared that the overturn of natural convection existed in this experimental result.

Analysis of axial magnetic field of coil type vacuum interrupter electrodes by comparing effective area at mid-gap plane (유효면적비교를 통한 COIL TYPE 진공인터럽터 전극의 측자계 분석)

  • Kim, Byoung-Chul;Yoon, Jae-Hun;Hoe, Jun;Kang, Seong-Wha;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.147-148
    • /
    • 2008
  • In this paper, we calculated the axial magnetic field at mid-gap plane between upper and lower electrode in vacuum interrupter by means of commercial finite element method Maxwell 3D and compared on the basis of "effective area" criterion. The models used in this paper are coil type(axial magnetic field) vacuum interrupter electrodes which have different numbers of coil segment. We used Dr. Schulmann's experimental equation which indicates minimum critical value of axial magnetic field to diffuse arc.

  • PDF

Characteristic of Coils According to Volume in Case of Embolization of Cerebral Aneurysm (뇌동맥류에 대한 색전술 시 체적에 따른 코일 특성)

  • Chae, Soo-In;Baek, Chang-Moo;Kim, Jeong-Koo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.247-254
    • /
    • 2012
  • This study presents the assessment results of coil length characteristics according to the volume of cerebral artery among the inpatients that received angiography and coil embolization following intracranial aneurysm from March, 2010 to September 2011. The volume rendering method was applied to the patients that received embolization to their cerebral arteries to obtain volume measurements. After coil embolization, the volume ratios were calculated with the volumes and lengths of coils. The embolic volume ratios were $43.11{\pm}3.11%$, $36.07{\pm}2.03%$, 40.91%, and 38.25% when the aneurysm sizes were 6mm or less, 6~10mm, 10~15mm and 20mm or more, respectively, being similar to the recommended volume ratios. Regardless of the types of aneurysm, the coil length according to volume was 0.65cm per $1mm^3$ of 20~$100mm^3$ when one type of 0.25mm diameter coil was used. They were 0.62cm per $1mm^3$ of 20~$150mm^3$ when one type of coil was used in the aneurysm volume of the saccular type and 0.60cm per $1mm^3$ of 20~$90mm^3$ when one type of coil was used in the aneurysm volume of the multi-lobulated type.

3.0-Tesla 자기공명 영상장치용 TX/RX L-spine RF Coil의 개발

  • 류연철;류승학;최보영;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.175-175
    • /
    • 2001
  • 목적: 현재 3.0T MRI system은 세계적으로 개발이 진행되고 있는 가운데, 3.0T에서 사용할 수 있는 RF coil의 개발이 시급한 상황이다. 1.0T 및 1.5T MRI 와는 달리 3.0T에서 사용할수 있는 Body coil 및 그에 따른 High power RF amplifier 제작에 많은 제약이 있다. 작은 용량의 RF amplifier를 이용하여 신체의 부분을 촬영 하고자 한다면, Tx/Rx 가능한 coil을 이용하면 가능할 것이다. 이러한 이유로 본 연구에서는 Tx/Rx 가능한 Quadrature type T/L-spine RF coil을 설계, 제작하여 3.0T 고자장 자기공명 영상장치에서의 임상진단 활용범위를 확대하였다. 3.0 Tesla 자기공명 영상장치에 사용을 위한 Quadrature type의 L-spine TX/RX RF 코일을 개발하여 고자장 자기공명 영상장치에서의 임상진단 활용범위의 확대를 목적으로 한다.

  • PDF

3.0-Tesla 자기공명 영상장치용 TX/RX L-spine RF Coil의 개발

  • 류연철;류승학;최보영;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.145-145
    • /
    • 2001
  • 목적 현재 3.0T MRI system은 세계적으로 개발이 진행되고 있는 가운데, 3.0T에서 사용 할 수 있는 RF coil의 개발이 시급한 상황이다. 1.0T 및 1.5T MRI 와는 달리 3.0T에서 사용할 수 있는 Body coil 및 그에 따른 High power RF amplifier 제작에 많은 제약이 있다. 작은 용량의 RF amplifier를 이용하여 신체의 부분을 촬영 하고자 한다면, Tx/Rx 가능한 coil을 이용하면 가능할 것이다. 이러한 이유로 본 연구에서는 Tx/Rx 가능한 Quadrature type Th-spine RF coil을 설계, 제작하여 3.0T 고자장 자기공명 영상장치에서의 임상진단 활용범위를 확대하였다. 3.0 Tesla 자기공명 영상장치에 사용을 위한 Quadrature type의 L-spine TX/RX RF 코일을 개발하여 고자장 자기공명 영상장치에서의 임상진단 활용범위의 확대를 목적으로 한다.

  • PDF