• Title/Summary/Keyword: Coil turns

Search Result 146, Processing Time 0.021 seconds

Fabrication of the Micromachined Transformer based on Air Core for the Application of Wireless Power Transmission (무선전력전송을 위한 에어 코어 기반의 트랜스포머 제작)

  • Kim, Sung-Tae;Cha, Doo-Yeol;Kang, Min-Suck;Cho, Se-Jun;Jang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Air core based transformers have been designed, simulated and fabricated by using micromachining process for the application of wireless power transmission with the range of frequency from 1 GHz to 20 GHz. Fabricated transformers are the types of solenoid transformers with primary and secondary coils. the size of fabricated transformer is $1.1{\times}1.5{\sim}2.15\;mm$ including ground shield. Transformers have been measured by dividing two groups based on the turns ratio between primary coil and secondary coil which are 1:1 transformers(the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7) and l:n transformers(the number of turns of primary coil and secondary coil: 3/3, 3/6, 3/9). As a result of the measurement, the lowest insertion loss of transformers ranged from 2 dB to 2.8 dB according to the number of turns between primary coil and secondary coil. And the lowest insertion loss from the transformers was measured at the frequency from 7 GHz to 11 GHz according to the number of turns between primary coil and secondary coil. Based on the measurement data from the microfabricated transformers, the transformer with the 3/3 turns in the primary coil and secondary coil showed best performance compared to others in terms of lowest insertion loss, lowest insertion loss frequency and bandwidth.

Current Limiting Characteristics of Flux-lock Type SFCL according to Inductance Variation

  • Choi Hyo-Sang;Park Hyoung-Min;Cho Yong-Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.87-89
    • /
    • 2006
  • We investigated the current limiting characteristics of flux-lock type superconducting fault current limiter(SFCL) according to inductance variation of coil 2. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting element in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity winding operations according to the winding directions between the coil 1 and coil 2. The current limiting characteristics in two winding directions were dependent of on the ratio of the number of turns of coil I and coil 2. The fault current increased when the number of turns of coil 2 increased in the subtractive polarity winding. On the contrary, the fault current decreased under the same conditions in case of the additive polarity winding.

Fabrication of the Micromachined Transformer using High Permeability NiFe Core (투자율이 높은 NiFe 코어를 이용한 마이크로 트랜스포머 제작)

  • Cho, Se-Jun;Cha, Doo-Yeol;Lee, Jai-Hyuk;Lee, Soo-Jin;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.194-198
    • /
    • 2010
  • Recently as the electronic devices are getting to be more and more smaller, transformers are needed to be micro fabricated using MEMS technology. In this paper transformers have been fabricated and measured by depositing insulation layer to reduce the loss of eddy current and in the middle core a high permeability permalloy was designed based on the turns ratio between primary coil and secondary coil which are 1:1 transformers. (the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7). The size of the transformers including ground shield are $1mm{\times}1.5mm$, $1mm{\times}1.95mm$, $1mm{\times}2.35mm$ respectively. The line width, pitch and the height of post are 50um. Based on the measured data from the micro fabricated transformers, the 3/3 turns in the primary coil and secondary coil showed the lowest insertion loss with 1.5 dB at 480 MHz and the 7/7 turns in the primary coil and secondary coil showed the highest insertion loss with 2.5 dB at 280 MHz. Also confirmed that the bandwidth goes up as the number of turns goes down. There was some difference between the actual measured data and the HFSS simulation result. It looks as if it is an error of the difference between oxidation of copper or the permeability of SU-8.

Comparison of Electrical Characteristics of The Solenoid Coils made of YBCO wire and BSCCO wire (BSCCO 선재와 YBCO 선재의 솔레노이드 코일의 전기적 특성 비교)

  • Lim, H.;Lee, D.M.;Lee, Ji-Kwang;Choi, H.;Cha, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.43-46
    • /
    • 2007
  • Solenoid coil is one of the commonly used one in superconducting power machines because it can produce uniform magnetic field at the center of the coil. Most of the AC loss in a solenoid coil is magnetization loss which is generated by the perpendicular magnetic field. This paper compares the electrical characteristics of two solenoid coils made of YBCO wire and BSCCO wire. We made and tested the BSCCO solenoid coil and YBCO solenoid coil which had the same number of turns and inner diameter. Number of turns and inner diameter of both coils were 30 turns and 10cm, respectively. AC loss of both coils were calculated by using the finite element method. Result shows that AC loss of YBCO coil was about 1/7 of that of the BSCCO coil when the current was 40A.

Effective 3-D FEM for large-scale high temperature superconducting racetrack coil

  • Huang, Xiangyu;Huang, Zhen;Xu, Xiaoyong;Li, Wan;Jin, Zhijian
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.3
    • /
    • pp.32-37
    • /
    • 2019
  • In various types of large-scale electrical applications, the number of coil turns in such machines is usually large. Electromagnetic simulation of large-scale superconducting coils (tens to hundreds of turns) is indispensable in the design process of superconducting electrical equipment. However, due to the large scale of the coil and the large aspect ratio of super-conducting material layer in HTS coated conductor, it is usually difficult or even unable to perform 3-D transient electromagnetic simulation. This paper introduces an effective 3-D electromagnetic simulation method for large-scale HTS coated conductor coil based on T-A formulation. The simulation and experimental results show that the 3-D model based on the T-A formulation using homogeneous strategy is more accurate than the traditional 2-D models. The memory usage is not sensitive to the number of turns and this model will be even more superior as the number of turns becomes larger.

Sensitivity Assessment of Spiral RF Surface Coils for MR Microscopic Imaging and Spectroscopy (자기공명미세영상 및 분광법을 위한 나선형 RF 표면코일의 감는 횟수에 따른 민감도 평가)

  • Woo, Dong-Cheol;Ha, Seung-Hoon;Choi, Chi-Bong;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.153-158
    • /
    • 2006
  • The purpose of this study was to improve the technique so as to develop an advanced sensitive RF surface coil for investigating the sensitivities of the multi-spiral surface coils, and we eventually wanted to achieve high resolution of the microscopic MR images and MR spectra. The magnetic field inhomogeneity and shape of a surface coil were statistically estimated by simulation of the magnetic field distribution. On the basis of the experimental results with single, 3 and S-turned spiral RF surface coils, we found that the 3-turned coil had the highest sensitivity. The present study showed that the sensitivity of the RF surface coil was improved by increasing the number of spiral coil turns, and also the SNR of the RF surface coil was dependent upon the number of spiral coil turns. However, we found, rather strikingly, that the sensitivity of excessive turns of the coils was decreased due to the rise of the coil's Impedance. Thus, the present results demonstrated that the sensitivity was not proportional to the number of a spiral RF coil's turns, and the number of spiral coil turns should be optimized for obtaining the highest sensitivity and SNR.

  • PDF

Optimal Design considering Magnetic Saturation Characteristic of Current Transformers for the Overcurrent Warning Circuit (과전류 경고 회로용 변류기의 자기포화 특성을 고려한 최적 설계)

  • Kim, Sun-Jong;Park, Eui-Jong;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.7
    • /
    • pp.781-786
    • /
    • 2015
  • In this paper, we analyzed characteristic of window type current transformer and we performed the optimal design consider to the loss; in order to design the current transformer figured signal of overcurrent warning circuit. The core size of window type current transformer was determined by the secondary coil turns. We analyzed current waveform, which is appeared by the number of coil turns on the core, we made sure the relation of secondary coil turns and load resistance in order to improve the non-sinusoidal wave by the flux saturation of the current transformer core. Additionally, we did improvement of the accuracy and optimal design through the transformation of the inner diameter and the stack length when the outer diameter of core is sustaining.

Measurement and Numerical Analysis of AC Loss in the HTS Pancake Coil and the HTS Solenid Coil (고온초전도 팬케이크 코일과 솔레노이드 코일의 교류손실 측정 및 수치해석)

  • Park Myung-Jin;Lee Sang-Soo;Lee Seung-Wook;Cha Guee-Soo;Lee Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.732-738
    • /
    • 2004
  • In this paper, we constructed 13 turns pancake coil and solenoid coil with HTS tape and measured AC losses of the pancake coil. The critical current of the pancake coil and the solenoid coil were 80A and 109A, respectively. To compare measured AC losses of the two coils, we carried out numerical analysis using 2-D FEM program for manufactured coils. This paper presents current density distribution, flux density distribution and AC losses of the pancake coil and the solenoid. As a result, we obtained that current density distribution was closely related to the orientation of magnetic field and distribution of AC losses were also closely related to the perpendicular component of flux density distribution in coil. The calculated AC losses of the two coils showed good agreement with measured AC losses and AC losses of the pancake coil was about 9 times bigger than that of the solenoid coil under the same turns and length.

The Development of Diagnostic Sensor for Inner Deterioration of Covered Electric Wire (피복전선의 내부 열화 검출용 센서 개발)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.244-249
    • /
    • 2014
  • In this research, it have developed a sensor that could diagnose inner deterioration of covered wires. With this sensor it observed results from simulation, and the attribute required for realization. For simulation it have used FLUX, it have considered all of geometric and electromagnetic information from coil and base metal that influences eddy current sensor's property in order to predict the final result. It assumed there is no mutual inductance in the coil with N number of turns, because equivalent current flows in coil that is continuously connected in eddy current sensor. It assumed circular coil loop draws a circle, always have self inductance, and they are connected in series and overlapped according number of turns (N) in coil, and bobbin configuration. Actual sensor was produced with consideration of inductance and number of turns (N). In conclusion, it were able to test the dependency through results from simulation, actual measurement, and modeling of simulation. It is considered that attributes of respective base metal and structure can be predicted by simulating in advance.

Optimal Coil Configuration Design Methodology Using the Concept of Equivalent Magnetizing Current (등가자화전류를 이용한 최적코일형상 설계방법)

  • Kim, Woo-Chul;Kim, Min-Tae;Kim, Yoon-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.43-49
    • /
    • 2007
  • A new electric coil design methodology using the notion of topology optimization is developed. The specific design problem in consideration is to find optimal coil configuration that maximizes the Lorentz force under given magnetic field. Topology optimization is usually formulated using the finite element method, but the novel feature of this method is that no such partial differential equation solver is employed during the whole optimization process. The proposed methodology allows the determination of not only coil shape but also the number of coil turns which is not possible to determine by any existing topology optimization concept and to perform single coil strand identification algorithm. The specific applications are made in the design of two-dimensional fine-pattern focusing coils of an optical pickup actuator. In this method, the concept of equivalent magnetizing current is utilized to calculate the Lorentz force, and the optimal coil configuration is obtained without any initial layout. The method is capable of generating the location and shape of turns of coil. To confirm the effectiveness of the proposed method in optical pickup applications, design problems involving multipolar permanent magnets are considered.