• Title/Summary/Keyword: Coil tube

Search Result 156, Processing Time 0.025 seconds

Study on Damping Coefficient of Shock Absorber with Magnetic Effects (자기효과를 이용한 충격흡수장치의 감쇠계수에 관한 연구)

  • Yi, Mi-Seon;Bae, Jae-Sung;Hwang, Jae-Hyuk;Hwang, Do-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.9
    • /
    • pp.832-838
    • /
    • 2011
  • The shock absorber with magnetic effect is suggested for a lunar lander. The shock absorber consists of a metal tube, a piston rod, and several permanent magnets moved by a piston rod in the tube, and the shock energy can be dispersed and dissipated by magnetic effects such as the magnetic force existed between a metal and magnets and the eddy current effect generated by a relative motion with a conductor and magnets. Besides, the shock-absorbing effect similar to that of a coil spring can be obtained by arranging the magnets in line, which are facing the same polar each other. The device has a very simple structure and is usable in space due to the unnecessariness of any oil or gas. The shock absorber was designed and manufactured for experiments and its spring and damping characteristics were studied by the theoretical, analytical and experimental methods.

DETECTION OF ODSCC IN SG TUBES DEPENDING ON THE SIZE OF THE CRACK AND ON THE PRESENCE OF SLUDGE DEPOSITS

  • Chung, Hansub;Kim, Hong-Deok;Kang, Yong-Seok;Lee, Jae-Gon;Nam, Minwoo
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.869-874
    • /
    • 2014
  • It was discovered in a Korean PWR that an extensive number of very short and shallow cracks in the SG tubes were undetectable by eddy current in-service-inspection because of the masking effect of sludge deposits. Axial stress corrosion cracks at the outside diameter of the steam generator tubes near the line contacts with the tube support plates are the major concern among the six identical Korean nuclear power plants having CE-type steam generators with Alloy 600 high temperature mill annealed tubes, HU3&4 and HB3~6. The tubes in HB3&4 have a less susceptible microstructure so that the onset of ODSCC was substantially delayed compared to HU3&4 whose tubes are most susceptible to ODSCC among the six units. The numbers of cracks detected by the eddy current inspection jumped drastically after the steam generators of HB4 were chemically cleaned. The purpose of the chemical cleaning was to mitigate stress corrosion cracking by removing the heavy sludge deposit, since a corrosive environment is formed in the occluded region under the sludge deposit. SGCC also enhances the detection capability of the eddy current inspection at the same time. Measurement of the size of each crack using the motorized rotating pancake coil probe indicated that the cracks in HB4 were shorter and substantially shallower than the cracks in HU3&4. It is believed that the cracks were shorter and shallower because the microstructure of the tubes in HB4 is less susceptible to ODSCC. It was readily understood from the size distribution of the cracks and the quantitative information available on the probability of detection that most cracks in HB4 had been undetected until the steam generators were chemically cleaned.

Development of Electronic Limit Switch for the Drive Unit of Incore Detector System Application (노내 핵계측 계통 구동기기의 전자식 한계스위치 개발)

  • 박종범;양승권;이상효
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.1-7
    • /
    • 2000
  • In this paper, we study a cause of malfunction of switch to control drive motor in DFMS(Digital Flux Mapping System) which can measure incore neutron flux of the nuclear plant, and develope a method to solve this problem. DFMS has the type of generating contact signal by mechanical switch lever, which is operated whenever thimble detector inserted or withdrawed through thimble Guide Tube. However the characteristics of the lever tend to be changed by mechanical degrade or bad environment and the lever finally generates errotic contact signal. Therefore we installed electric coil ass'yin the outside of Guide Tube instead of mechanical switch assy's. In addition we applied resonance effect to control circuit and installed condenser in the input of power supply to protect noise and interference. After completion of this improvement, we tested this improved device repetitively under the various conditions. In conclusion, we identified the generation of the desired contact signal and the prevention of detector failure through plant surveillance test during normal plant operation.

  • PDF

Development of inside-out probes for both Nuclear Magnetic Resonance Imaging and Nuclear Magnetic Resonance Spectroscopy (핵자기공명 영상법과 핵자기공명 분광법을 위한 뒤집음-탐침의 개발에 대한 연구)

  • Lee, Dong-Hun;Go, Rak-Gil;Jeong, Eun-Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.309-316
    • /
    • 1995
  • RF (radio-frequency) probes of Nuclear Magnetic Resonance are one of the important factors and should be designed and built properly depending upon the geometry of the samples and the information. In general there are two kinds of rf probes : one encircles the sample while the other is placed on the surface of the sample. However, in case that the samples on human internal organs have a tube shape, the two kinds of rf probes, as specified above, are usually unsuitable for the internal imaging due to the degradation of signal-to-noise ratios (SNR's). In this case a probe should be positioned as close to the area as possible by putting the probe in the tubelike sample to improve filling factor In the present study inside-out probes have been constructed in the three different shapes such as an anti-solenoidal, a saddle and a dual surface types. RF-field distributions have also been calculated depending upon the geometrical changes of anti-solenoid probes. Moreover, the performance of the inside-out probes has been checked by measuring SNR's of the images acquired. The inside-out probes constructed in this study produced better SWR's and rf-field uniformity in the area close to the probes in comparing with any other commercial probes. There is a high feasibility that the constructed probes in the present study are applicable to the diagnosis of human bodies.

  • PDF

The Clinical Study for Empyema: 176 Cases (농흉의 임상적 고찰[176예])

  • Oh, Bong-Seok;Choi, Jong-Beom;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.475-485
    • /
    • 1980
  • For the past 5 year 6 months from January 1975 to June 1980, 176 patients with empyema have been treated in Chonnam University Hospital. They were 134 males and 42 females ranging from ] 8 days to 69 years of age. [mean age: 26.1 years] The duration of illness prior to treatment was relatively shorter in pediatric group than in adult group, that is, the duration of less than 1 month was 89.5% in pediatric group and 38.0% in adult group. In bacteria study there were Staphylococcus 26.1%, Streptococcus 17.6%, E. coil 10.8%, Pseudomonas 10.8%, Diplococcus pneumoniae 5.7% and Candidia. And 4 children and 3 adults had infections of two species of bacteria. The underlying pathologic lesions were pyogenic pneumonia 34.7%, tuberculosis 29.5%, paragonimiasis 15.3%, trauma 9.7% and postoperative state. The over-all mortality rate was 1.7% [3 patients]. The causes of death were sepsis In 1 child and sepsis secondary to esophageal fistula in 2 adults. Adequate drainage and obliteration of the pleural space seems to be the most important aspect of treatment and can frequently be achieved by initial tube drainage in acute empyema, especially in the pediatric group. The chronic thick walled or loculated cavities required open window therapy, decortication, resection therapy and sterilization. Modified Eloesser`s operation and 0.3-0.5% potadine irrigation brought good result in the patients who had general weakness, marked pulmonary parenchymal destruction due to pyothorax, and pyothorax with severe bronchopleural fistula.

  • PDF

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

Development and rotating test of the high temperature superconducting motor with on-board cryocooler (탑재형 냉동기를 이용한 고온 초전도 모터 개발 및 회전 실험)

  • Ki, Tae-Kyung;Kim, Young-Kwon;Kim, Hee-Sun;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • In this paper, the prototype of the HTS motor with an on-board cryocooler, is fabricated and tested. The overall system is composed of the stator with conventional copper winding, the rotor with superconductor, and the rotating cryocooler designed from the on-board concept. The rotor is fabricated as the race-track coil with 2G, YBCO tape and contacts with the on-board cryocooler while being rotated together. An inline-type pulse tube refrigerator is used as the on-board cryocooler. The cryocooler is fabricated from optimal process to satisfy the structure and thermal stability of the on-board system. Each component is integrated according to carefully defined sequence. Specially, a combining method of torque tubes is an important part for sustaining stability of the rotor and the cryocooler. In the rotating test, the HTS motor is successfully operated with 240 rpm of rotating speed when 75 A current is supplied to the superconducting rotor. In this paper, potential problems of the HTS motor system using the on-board cryocooler are proposed and solved, and realistic possibility of this concept is also confirmed.

A Study on the Flow and Control Characteristics of Magneticfluid in Actuator (액추에이터에서의 자성유체 제어 및 유동 특성에 관한 연구)

  • Kim, Joong;Chun, Un-hack;Lee, Hee-Sang;Lee, Bong-Gyu;Hwang, Seung-Sik;Oh, Chang-Bok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.258-267
    • /
    • 1999
  • The aim of the study is to provide fundamental information for the development of magneticfluid actuator. To achieve the aim, the force and dynamic characteristics of magenticfluid are investigated by experiment for the various of tube diameter, height and position of magneticfluid column in magneticfield according to supplied voltage of solenoid coil, wave form and frquency. From this study, actuating force of magneticfluid is generated by magneticfield. The magnitude of force increases as the intensity of magneticfield becomes strong and the center of magneticfield becomes lower than the center of magneticfluid column. And the force of magneticfluid relates to the volume of magneticfluid more than the height and diameter. The response delay time decreases as the height of magmeticfluid more than the height and diameter. The response delay time decrease as the height of magneticfluid column becomes longer and the center of magneticfield becomes lower than the center of magniticfluid column. But, the approaching time increases as supplied voltage becomes higher and the center of magneticfiled becomes higher than the center of magniticfluid column. The frequency generating maximum force is 1Hz and the critical frequency is about 4Hz.

  • PDF

Fabrication of 6 double pancakes Bi-2223 HTS magnet (6 더블팬케이크 Bi-2223 고온초전도 마그네트 제작)

  • Ha, Hong-Soo;Jang, Hyun-Man;Lee, Nam-Jin;Oh, Sang-Soo;Ha, Dong-Woo;Ryu, Kang-Sik;Lee, Hai-Gun;Lee, Jun-Suck
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.373-377
    • /
    • 1999
  • HTS magnet operated at 20${\sim}$40 K was fabricated using three pieces of 100 m Bi-2223 high temperature superconductors fabricated by powder-in-tube process. It was composed of 6 double pancakes with 75 ID. and 113 OD. connected by lab splice. Coil I$_c$ of each DP.(double pancake) obtained for a 140 turn, fabricated using react and wind procedure was 6${\sim}$8 A at 77 K, self field. The maximum field was measured 0.06 T at lop = 5 A, 77 K. The joint resistance due to lap splice of HTS tapes affect badly to operate HTS magnet with persistent current mode, total effective magnet resistance included lap splice was 55 ${\mu}$ ${\omega}$ at 77 K.

  • PDF

Development of the Integrated Information System for 3D Product Design/RP/CAE/3D Mold Design/Tooling (3차원 설계/RP/CAE/3차원 금형설계/제작 정보일원화시스템 개발)

  • 윤정호;전형환;안상훈;조명철
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.1
    • /
    • pp.35-43
    • /
    • 1997
  • Concurrent Engineering is one of the methods which are used for the rapid product development. One of the important features in Concurrent Egineering is that the development process is to be parallel and the organization should be cross-functional. In order that the process be parallel and that the organization be cross-functional, an integrated information system such as PDM (Product Data Management) is required. Although the integrated data base is constructed, it could be meaningless if the application softwares were not inter-operable. This study shows an example of intergrated information system from three-dimensional product design to mold design and tooling for the development of Deflection Yoke(DY) which is one of the important parts of Cathode Ray Tube(CRT). A three-dimensional product design software, which is based on a commercial code, has been developed by ourselves. Selective Laser Sintering(SLS), which is one of the rapid prototyping techniques, has been used in this study. Mold design has been done by the three-dimensional way. A newly developed method of mold tooling, which is called Quick Die Manufacturing(QDM), has been introduced.

  • PDF