• Title/Summary/Keyword: Coil tube

Search Result 156, Processing Time 0.03 seconds

Experimental Study of Friction Factors for Laminar, Transition, and Turbulent Flow Regimes in Helical Coil Tubes (헬리컬 코일 튜브에서의 층류, 천이, 난류 영역의 마찰계수에 대한 실험적 연구)

  • Park, Won Ki;Kim, Taehoon;Do, Kyu Hyung;Han, Yong-Shik;Choi, Byung-Il
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The friction factors according to the flow regimes in helical coil tubes depend on the coil diameter, the tube diameter, and the coil pitch. In previous studies, correlations for the laminar flow regime in helical coil tubes have been proposed. However, studies on the transition flow regime and the turbulent flow regime are insufficient and further researches are necessary. In this study, characteristics of the friction factors for the laminar, transition and turbulent flow regimes in helical coil tubes were experimentally investigated. The helical coil tubes used in the experiments were made of copper. The curvature ratios of the helical coil tubes, which means the ratio of helical coil diameter to inner diameter of the helical coil tube are 24.5 and 90.9. Experiments were carried out in the range of $529{\leq}Re{\leq}39,406$ to observe the flows from the laminar to the turbulent regime. The friction factors were obtained by measuring the differential pressures according to the flow rates in the helical coil tubes while varying the curvature ratios of the helical coil tubes. Experimental data show that the friction factors for the helical coil tube with 24.5 in the curvature ratio of the helical coil tube were larger than those in the straight tube in all flow regimes. As the curvature ratio of the helical coil tube increases, the friction factor in turbulent flow regime tends to be equal to that of the straight tube. In addition, it was confirmed that the transition flow regimes in the helical coil tubes were much wider than those in the straight tube, also the critical Reynolds numbers were larger than those in the straight tube. The results obtained in this experimental study can be used as basic data for studies on the water hammer phenomenon in helical coil tubes.

Thermal Performance of a Spirally Coiled Finned Tube Heat Exchanger Under Wet-Surface Conditions

  • Wongwises Somchai;Naphon Paisarn
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.212-226
    • /
    • 2006
  • This paper is a continuation of the authors' previous work on spiral coil heat exchangers. In the present study, the heat transfer characteristics and the performance of a spirally coiled finned tube heat exchanger under wet-surface conditions are theoretically and experimentally investigated. The test section is a spiral-coil heat exchanger which consists of a steel shell and a spirally coiled tube unit. The spiral-coil unit consists of six layers of concentric spirally coiled finned tubes. Each tube is fabricated by bending a 9.6 mm diameter straight copper tube into a spiral-coil of four turns. The innermost and outermost diameters of each spiral-coil are 145.0 and 350.4 mm, respectively. Aluminium crimped spiral fins with thickness of 0.6 mm and outer diameter of 28.4 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Air and water are used as working fluids in shell side and tube side, respectively. The experiments are done under dehumidifying conditions. A mathematical model based on the conservation of mass and energy is developed to simulate the flow and heat transfer characteristics of working fluids flowing through the heat exchanger. The results obtained from the present model show reasonable agreement with the experimental data.

Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers (경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

An Experimental Study on tee Heat Transfer Enhancement Effect of the Coil Fins for Ice Storage System (빙축열 시스템에서의 코일 휜의 열전달 촉진 효과에 관한 실험적 연구)

  • 성병호;이분희;임광빈;김철주
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2004.05a
    • /
    • pp.219-224
    • /
    • 2004
  • The present study was to investigate the heat transfer enhancement effect of coil wire fins in an ice storage system. For the two cases of tubes with internal brine flows, a finned tube with coil wires on its outer surface and a smooth tube, the rates of ice layer were tested and compared for both the icing processes. The coil fins were made of a stainless steel wire with a dia. of 2.0(mm), and the coil had an outer dia. of 10(mm) and a helix angle of 60($^{\circ}$). The experimental results showed that the coil fins could substantially reduce the thermal resistance of the ice layer, and enhance the heat flow rates between the water in the storage tank and the brine. The ice storing time was found to be shortened by 13(%) for the coil fins to get the same amount of ice layer that was built on the smooth tube wall for 10 hours of operation when the same thermal conditions were provided.

  • PDF

Study on forced convective heat transfer in helically ceiled tubes (나선코일튜브내의 강제대류 열전달에 관한 연구)

  • 한규일;박종운;임태우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.282-291
    • /
    • 1998
  • Heat transfer performance are studied for the turbulent flow of water in 3 smooth tube coils having ratios of coil to tube diameter of 16, 21 and 27, and a corrugated-coiled tube having a ratio of coil to tube diameter of 29, for Reynolds numbers from 8000 to 60000 and is also compared with the limited results available to data. The experiments are carried out for the fully developed turbulent flow of water in tube coils under the condition of uniform heat flux. This work is limited 0 tube coils of R/a between 10 and 30. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. The performance of coiled tube best transfer performance. The performance of coiled tube with a similar curvature ratio is better for a corrugated-coiled tube(R/a=17) than for a smooth coiled tube(R/a=16). An empirical relation which correlates most of the data within $\pm$25% was also developed. Test result shows that the Nusselt number is found to be affected by a secondary flow due to curvature.

  • PDF

Ice Making Characteristics According to Changing Shape of Ice Making Tube (제빙관의 형태변화에 따른 제빙특성)

  • Jung, Eun-Ho;Park, KI-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.291-296
    • /
    • 2009
  • Ice accumulating system patterned ice-an-coil is the way of refrigerating regenerative materials on the surface of copper-tube inserted into the inside of ice-storage. The study experimented to understand ice-an-coil type ice making characteristics according to changing shape of ice making tube. The experiment were carried out under various conditions, that used brine temperature($-l0^{\circ}C$, $-6^{\circ}C$) brine flow rate(l.0m/s, 1.8m/s) and inlet water temperature($6^{\circ}C$, $12^{\circ}C$) etc. Mass of ice per making area increased according to the decrease of the brine temperature and inlet water temperature, but that was increased according to the increase of the brine flow rate. And I set up two hypotheses and compared the capacity of ice-making of the two cases; each had the same thermal area and one had an round-shaped copper tube but the other had an oval-shaped copper tube.

Numerical Analysis of the Expansion of a Metalic Cylinder Under Electormagnetic Pulse (전자장 pulse 하의 금속 Cylinder의 팽창에 대한 연구)

  • Seo, Ju Ha
    • Journal of Industrial Technology
    • /
    • v.8
    • /
    • pp.71-80
    • /
    • 1988
  • 높은 전압으로 충전된 Capacitor를 순간적으로 원통형 coil에 방전하면 순간적으로 강한 전자장 impulse가 발생한다. 이때 coil를 둘러 싼 금속 tube는 radial 방향의 힘을 얻어 팽창한다. 본 논문은 이때 tube내의 전자장분포와 tube 벽의 움직임을 integral equation method를 사용하여 해석하였다.

  • PDF

An Experimental Study on Dryout Pattern of Two-Phase Flow in Helically Coiled Tubes

  • Chung, Won-Seok;Sa, Young-Cheol;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1540-1549
    • /
    • 2002
  • Experimental results are presented for the effects of coil diameter, system pressure and mass flux on dryout pattern of two-phase flow in helically coiled tubes. Two tubes with coil diameters of 215 and 485 mm are used in the present study, Inlet system pressures range from 0.3 to 0.7 MPa, mass flux from 300 to 500 kg/㎡s, and heat flux from 36 to 80 kw/㎡. A partial dryout region exists because of the geometrical characteristics of the helically coiled tube. The length of the partial dryout region increases with coil diameter and system pressure. On the other hand, it decreases with increasing mass flux. The critical quality at the tube top side increases with mass flux, but decreases with increasing system pressure. This tendency is more notable when the coil diameter is larger. When the centrifugal force effect becomes stronger, dryout starts at the top and bottom sides of the tube. However, when the gravity effect becomes stronger, dryout is delayed at the tube bottom side. In some cases when the mass flux is low, dryout occurs earlier at the outer side than at the inner side of the tube because of film inversion.

Fluidization and Heat Transfer Characteristics in the Fluidized Bed(II) (기일고류동층내류동화(氣一固流動層內流動化) 및 전열특성(傳熱特性)에 관한 연구(硏究)(II))

  • Park, Jong-Suen;Baek, Ko-Kil;Kim, Yeun-Young;Jeon, Sung-Taek
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.51-60
    • /
    • 1994
  • The fluidization characteristics of the furan foundry sand fluidized bed and the heat transfer characteristics on a single spiral coil tube in the bed have been investigated. In the paper, the heat transfer coefficients for a single spiral coil tube are measured in the furan foundry sand bed as a function of the ratio of heated coil tube pitch to diameter(p/Do) and the ratio of heated coil tube pitch to particle size(p/dp). The experimental results are as follows. 1) Mean heat transfer coefficients increases according to the increasing ratio of heated coil tube pitch to diameter(p/Do). 2) The Increasing rates of mean Nusselt numbers are more greater in the case of p/Do=1.58 than p/Do=4.75. 3) Mean Nusselt number can be expressed by the following equation, $Nu_{mean}=C\;Re^m\;Pr_g^{0.4}(p/dp)^n$.

  • PDF

A Study on the Pressure Loss in Helically Coiled Tubes (나선코일 튜브 내에서의 압력손실에 관한 연구)

  • Han, K.I.;Bark, J.U.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF