• 제목/요약/키워드: Coil performance

검색결과 601건 처리시간 0.034초

실리콘 압저항형 진동 센서를 이용한 Voice-coil형 구동기의 미소 전자력 측정 (The Micro Electromagnetic Force Measurement of Voice-coil Actuator using Semiconductor Piezoresistive Type Vibration Sensor)

  • 권기진;이기찬;박세광
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권2호
    • /
    • pp.147-152
    • /
    • 1999
  • Semiconductor piezoresistive type vibration sensor was fabricated by using semiconductor process and micromachining technology. To measure the micro electromagnetic force between coil and magnet, fabricated vibration sensor was used. Toapply micro electromagnetic force produced from the micro exciter, small-sized NdFeB permanent magnet was attached on the mass of the fabricated vibration sensor. The measured electromagnetic force are about 5~180dyne when the applied sinusoidal current of 1KHz in the range of 1.5~8mA. The measurement of micro electromagnetic forcewas performed by changing the distance between coil and magnet. Output characteristics of micro electromagnetic force according to the applied coil current were linear. Furthermore, output results were used to get the transfer constant that is important to decide the efficiency and the performance of the coil and magnet.

  • PDF

전기자동차 무선 충전용 수신패드 식별코일의 형상 설계 및 운용 방안 (Receiving Pad Identification Coil for Wireless Charging of Electric Vehicle)

  • 심동현;조현우;허훈;이주아;손원진;이병국
    • 전력전자학회논문지
    • /
    • 제27권6호
    • /
    • pp.455-463
    • /
    • 2022
  • This study proposes a receiving pad identification coil for wireless charging of electric vehicles. The proposed coil identifies the shape of the receiving pad through magnetic coupling with the receiving pad. Therefore, the shape of the coil is designed to show the different magnetic properties of each receiving pad. The accuracy of this design is verified through finite element method simulation. Furthermore, the operation method of the secondary pad identification circuit is described, and the appropriate magnitude and length of the pulse voltage applied to this circuit for receiving pad identification are derived through simulation. The performance of the proposed identification coil set is verified by the experimental results.

지열을 이용한 코일 침적형 히트펌프의 성능 특성 (Performance characteristics of the Coil Deposition Type Heat Pump using Geothermal Energy)

  • 오후규;이동건;전민주;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.437-444
    • /
    • 2012
  • 본 논문은 지열을 이용한 코일 침적형 히트펌프 시스템의 운전변수에 대한 최적 설계를 위해서 히트펌프의 성능 특성을 실험적으로 조사하였다. 본 연구에서 고려된 작동변수로는 과냉각도, 증발온도, 응축온도 등이다. 그 실험결과를 요약하면 다음과 같다. 지열 이용 코일 침적형 히트펌프 시스템의 증발온도와 과냉각도가 증가할수록, 응축온도는 감소할수록 성능계수는 증가함을 알 수 있다. 즉, 지열 이용 코일 침적형 히트펌프 시스템의 증발온도, 응축온도, 과냉각도는 냉방과 난방의 성능계수에 영향을 미치는 것을 알 수 있다. 따라서 본 연구에서 제안하는 히트펌프 시스템이 최고의 성능을 나타내기 위한 최적의 운전조건을 결정할 필요가 있다.

Thermal Performance of a Spirally Coiled Finned Tube Heat Exchanger Under Wet-Surface Conditions

  • Wongwises Somchai;Naphon Paisarn
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.212-226
    • /
    • 2006
  • This paper is a continuation of the authors' previous work on spiral coil heat exchangers. In the present study, the heat transfer characteristics and the performance of a spirally coiled finned tube heat exchanger under wet-surface conditions are theoretically and experimentally investigated. The test section is a spiral-coil heat exchanger which consists of a steel shell and a spirally coiled tube unit. The spiral-coil unit consists of six layers of concentric spirally coiled finned tubes. Each tube is fabricated by bending a 9.6 mm diameter straight copper tube into a spiral-coil of four turns. The innermost and outermost diameters of each spiral-coil are 145.0 and 350.4 mm, respectively. Aluminium crimped spiral fins with thickness of 0.6 mm and outer diameter of 28.4 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Air and water are used as working fluids in shell side and tube side, respectively. The experiments are done under dehumidifying conditions. A mathematical model based on the conservation of mass and energy is developed to simulate the flow and heat transfer characteristics of working fluids flowing through the heat exchanger. The results obtained from the present model show reasonable agreement with the experimental data.

환기시스템 설치 강의실에서 시스템에어컨과 팬코일유닛의 열쾌적성 및 환기성능 평가 (Evaluation of Thermal Comfort and Ventilation Performance in the Lecture Room with Ventilation System and Two Different Air-conditioning Systems: System Air-conditioner or Fan Coil Unit)

  • 한창우;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1079-1087
    • /
    • 2005
  • In this paper, thermal comfort and ventilation performance characteristics in the lecture room with the ventilation system and two different air-conditioning systems, system air-conditioner or fan coil unit, were evaluated by experimental and numerical methods. We compared the measured data with the computational results of the predicted mean vote and carbon dioxide concentration. Additionally the ventilation effectiveness was calculated numerically. From a viewpoint of the uniformity of PMVs in the lecture room, the thermal distribution performance of the system air-conditioner was more effective than the fan coil unit. Carbon dioxide concentration and ventilation effectiveness were barely affected by the type of the air-conditioning system.

무선전력전송을 위한 에어 코어 기반의 트랜스포머 제작 (Fabrication of the Micromachined Transformer based on Air Core for the Application of Wireless Power Transmission)

  • 김성태;차두열;강민석;조세준;장성필
    • 한국전기전자재료학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2009
  • Air core based transformers have been designed, simulated and fabricated by using micromachining process for the application of wireless power transmission with the range of frequency from 1 GHz to 20 GHz. Fabricated transformers are the types of solenoid transformers with primary and secondary coils. the size of fabricated transformer is $1.1{\times}1.5{\sim}2.15\;mm$ including ground shield. Transformers have been measured by dividing two groups based on the turns ratio between primary coil and secondary coil which are 1:1 transformers(the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7) and l:n transformers(the number of turns of primary coil and secondary coil: 3/3, 3/6, 3/9). As a result of the measurement, the lowest insertion loss of transformers ranged from 2 dB to 2.8 dB according to the number of turns between primary coil and secondary coil. And the lowest insertion loss from the transformers was measured at the frequency from 7 GHz to 11 GHz according to the number of turns between primary coil and secondary coil. Based on the measurement data from the microfabricated transformers, the transformer with the 3/3 turns in the primary coil and secondary coil showed best performance compared to others in terms of lowest insertion loss, lowest insertion loss frequency and bandwidth.

Design of Crisscrossed Double-Layer Birdcage Coil for Improving B1+ Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz

  • Seo, Jeung-Hoon;Han, Sang-Doc;Kim, Kyoung-Nam
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.308-311
    • /
    • 2015
  • We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density ($B_1{^+}$) along the main magnetic field ($B_0$)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational analysis with the finite-difference time domain method (FDTD) and compared with SLBC coil in terms of the $B_1$ and the $B_1{^+}$ distribution. As per the computational calculation studies, the mean value in the two-dimensional $B_1{^+}$ map obtained at the mid-axial slice with the proposed DLBC coil is slightly lower than that obtained with the SLBC coil, but the $B_1{^+}$ value of the DLBC coil in the outermost plane (40 mm away from the central plane) shows improvements of 19.3% and 24.8% over the SLBC coil $B_1{^+}$ value when simulating a spherical phantom and realistic mouse body modeling. These simulation results indicate that, the $B_1{^+}$ homogeneity along the z-direction was improved by using DLBC configuration. Our approach enables $B_1{^+}$ homogeneity improvement along the zdirection, and it can also be applied to ultra-high field (UHF) MRI systems.

와이어 코일이 삽입된 나선형 내면가공관의 열전달 및 압력강하 특성 (Characteristics of Heat Transfer and Pressure Drop for Spirally Indented Tubes with Wire Coil Inserts)

  • 최인수;박병덕;남상철
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.395-401
    • /
    • 2001
  • The characteristics of heat transfer and pressure drop through tubes has been investigated experimentally for a compound heat transfer enhancement. The test tubes were spirally indented tubes with wire coil inserts which had a various combinations of pitch and helix angles. Pure water was used as working fluids for the experiments, Heat transfer coefficients and friction factors of the test tubes were evaluated from the values of measured temperatures, flow rates and pressure drops. An performance evaluation was performed to find an optimal combination of spirally indented tubes with wire coil inserts. When the helix angle of wire coil insert are $71^{\circ}-72^{\circ}$, the best heat transfer enhancement was shown. The friction factor was 9 - 13 times higher than those in smooth tubes, and the heat transfer was enhanced a maximum of 500%.

  • PDF

IH압력밥솥의 균일가열을 위한 WORK-COIL의 최적배치 (Optimal Placement of Work-Coil for Improving the Performance of Heat Pressure Rice Cooker Uniformly)

  • 노희석;신동명;전용석;박성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2060-2063
    • /
    • 1998
  • The proper placement of work-coil is needed for heating the interior of an IH rice cooker uniformly. It is possible that the flavor of rice is better by heating it through the optimal placement of the work-coil of the IH rice cooker. This paper describes the procedure and the result of finding the optimal placement of the work-coil by analyzing the properties of the rising temperatures of the interior through Taguchi Method.

  • PDF