• Title/Summary/Keyword: Coil

Search Result 3,823, Processing Time 0.032 seconds

Statistical analysis for HTS coil considering inhomogeneous Ic distribution of HTS tape

  • Jin, Hongwoo;Lee, Jiho;Lee, Woo Seung;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.2
    • /
    • pp.41-44
    • /
    • 2015
  • Critical current of high-temperature superconducting (HTS) coil is influenced by its own self magnetic field. Direction and density distribution of the magnetic field around the coil are fixed after the shape of the coil is decided. If the entire part of the HTS tape has homogeneous $I_c$ distribution characteristic, quench would be initiated in fixed location on the coil. However, the actual HTS tape has inhomogeneous $I_c$ distribution along the length. If the $I_c$ distribution of the HTS tape is known, we can expect the spot within the HTS coil that has the highest probability to initiate the quench. In this paper, $I_c$ distribution within the HTS coil under self-field effect is simulated by MATLAB. In the simulation procedure, $I_c$ distribution of the entire part of the HTS tape is assume d to follow Gaussian-distribution by central limit theorem. The HTS coil model is divided into several segments, and the critical current of each segment is calculated based on the-generalized Kim model. Single pancake model is simulated and self-field of HTS coil is calculated by Biot-Savart's law. As a result of simulation, quench-initiating spot in the actual HTS coil can be predicted statistically. And that statistical analysis can help detect or protect the quench of the HTS coil.

Postmortem analysis of a failed liquid nitrogen-cooled prepolarization coil for SQUID sensor-based ultra-low field magnetic resonance

  • Hwang, Seong-Min;Kim, Kiwoong;Yu, Kwon Kyu;Lee, Seong-Joo;Shim, Jeong Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.44-48
    • /
    • 2014
  • A liquid nitrogen-cooled prepolarization ($B_p$) coil made for ultra-low field nuclear magnetic resonance and magnetic resonance imaging (ULF-MR) designed to generate 7 mT/A was fabricated. However, with suspected internal insulation failure, the coil was investigated in order to find out the source of the failure. This paper reports detailed build of the failed $B_p$ coil and a number of analysis methods utilized to figure out the source and the mode of failure. The analysis revealed that pyrolytic graphite sheet linings put on either sides of the coil for better thermal conduction acted as an electrical bridge between inner and outer layers of the coil to short out the coil whenever a moderately high voltage was applied across the coil. A simple model circuit simulation corroborated the analysis and further revealed that the failed insulation acted effectively as a damping resistor of $R_{d,eff}=6{\Omega}$ across the coil. This damping resistance produced a 50 ms-long voltage tail after the coil current was ramped down, making the coil not suitable for use in ULF-MR, which requires complete removal of magnetic field from $B_p$ coil within milliseconds.

Coil Design of Pulse Induction Metal Detector (펄스 유도 방식의 금속탐지기 코일 설계)

  • Jung, Byung-Min;Chang, Yu-Shin;Han, Seung-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.389-396
    • /
    • 2015
  • A coil design of pulse induction metal detectors has been described. The search coil was demonstrated by using the wire with the diameter of 0.3 mm, 0.5 mm and 1.0 mm and the dielectric plate with the $30cm{\times}30cm$ and $35cm{\times}35cm$, the time constant and the currents of the coil as the variation of the coil size and the number of coil turns was characterized. The coil parameters like the resistance, the inductance and the time constants as the variation of the diameter of the wire, the coil size and the number of coil turns were compared and analysed through the calculation and the measurement. In addition, investigating the coil currents as the variation of the input pulse width, the coil design of pulse induction metal detectors has been discussed.

Fabrication of the Micromachined Transformer based on Air Core for the Application of Wireless Power Transmission (무선전력전송을 위한 에어 코어 기반의 트랜스포머 제작)

  • Kim, Sung-Tae;Cha, Doo-Yeol;Kang, Min-Suck;Cho, Se-Jun;Jang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Air core based transformers have been designed, simulated and fabricated by using micromachining process for the application of wireless power transmission with the range of frequency from 1 GHz to 20 GHz. Fabricated transformers are the types of solenoid transformers with primary and secondary coils. the size of fabricated transformer is $1.1{\times}1.5{\sim}2.15\;mm$ including ground shield. Transformers have been measured by dividing two groups based on the turns ratio between primary coil and secondary coil which are 1:1 transformers(the number of turns of primary coil and secondary coil: 3/3, 5/5, 7/7) and l:n transformers(the number of turns of primary coil and secondary coil: 3/3, 3/6, 3/9). As a result of the measurement, the lowest insertion loss of transformers ranged from 2 dB to 2.8 dB according to the number of turns between primary coil and secondary coil. And the lowest insertion loss from the transformers was measured at the frequency from 7 GHz to 11 GHz according to the number of turns between primary coil and secondary coil. Based on the measurement data from the microfabricated transformers, the transformer with the 3/3 turns in the primary coil and secondary coil showed best performance compared to others in terms of lowest insertion loss, lowest insertion loss frequency and bandwidth.

Biosynthetic Regulation of Invertase from Recombinant E. coil pYC17 (재조합 대장균 pYC17이 생성하는 세포내 invertase의 생합성 조절)

  • Yi, Sung-Hun;No, Jae-Duck;Lee, Dae-Hyung;Lee, Jong-Soo
    • The Journal of Natural Sciences
    • /
    • v.17 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Regulation of invertase biosynthesis was studied with the E. coil harboring recombinant plasmid, pYC17. Biosynthesis of invertase in the recombinant E. coil was effectively induced in the presence of 30mM of sucrose for 3h. Glucose also repressed the invertase induction in the recombinant E. coil at 10 mM, lower than that of parent strain (30 mM).

  • PDF

Design of the Current Segment Coil for Accelerating the Magnetic Materials (자성물질을 가속시키기 위한 전류 Segment 코일의 설계)

  • Chung, Byung-Tae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.861-866
    • /
    • 2012
  • The distance optimizing between coil and magnetic materials never be specified in the magnetic materials acceleration using the coil till now. We can know to be the distance which optimizes when being in the half position about the distance of intercoil by the result of the max point on the Differential calculus. Whether several top and bottom current segment coil structures were made and the steel ball in which the current segment coil structure is the magnetic materials could be accelerated in the optimizing distance or not confirmed. When the coil valley current about the mass of the steel ball was known as the experiment and it was but to be the nose consequently it applied to the magnetic materials and magnetic fluid, the optimal distance was solved between the coil and material.

A Trip Coil Fault Detection of Circuit Breaker (차단기 트립코일 이상감지 장치)

  • Youn, Ju-Houc;Lee, Jong-Hun;Park, Noh-Sik;Lee, Dong-Hea
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • The circuit breaker of power distribution board is essential part for the protection of electrical disaster from load short, trouble of power system. For the normal operation of circuit breaker, trip coil of the circuit breaker can cut the mechanical contact of circuit breaker from the detection of power system troubles. This paper presents a design and experimental results of trip coil fault detection system for the real time monitoring of the circuit breaker. The designed system is consisted by the trip coil fault detector which is connected to the each circuit breaker and remote monitoring unit. The trip coil fault detector can detect the impedance and operating voltage of the trip coil, and the detected values are compared with the normal state. And the remote monitoring unit can be connected to the 32 channels of trip coil fault detectors by serial communication. From the designed system, the fault and normal states of the trip coil can be remotely monitored in real time. The designed system is verified by the practical circuit breaker of power distribution board. And the results shows the effectiveness of the designed system.

Current Limiting Characteristics of Improved Flux-Lock Type SFCL According to Winding Direction of Coil 2 and Variable Number of Coil 1 and Coil 2 (개선된 자속구속형의 2차 측 권선 방향과 1차 권선수와 2차 권선수의 변화에 따른 사고전류제한 특성)

  • Kim, Yong-Jin;Du, Ho-Ik;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.714-717
    • /
    • 2010
  • The improved flux-lock type superconducting fault current limiter (SFCL) is composed of a series transformer and superconducting unit of the yttrium-barium-copper-oxide (YBCO) coated conductor. In this paper, we investigated current limiting characteristics through winding direction of coil 2 and variable number of coil 1 and coil 2 in improved flux-lock type SFCL. The better fault current characteristics and the burden of YBCO coated conductor can be confirmed from the experimental result in the higher turn ratio of coil 1 and coil 2 in the additive conditions. In case of subtractive condition, we can confirm a similar result in the same case of experimental conditions. but the burden of YBCO coated conductor has been increased from an increase in winding numbers of coil 2.

Combined Endovascular and Microsurgical Procedures as Complementary Approaches in the Treatment of a Single Intracranial Aneurysm

  • Lim, Yong-Cheol;Shin, Yong-Sam;Chung, Joon-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.1
    • /
    • pp.21-25
    • /
    • 2008
  • Objective : Both endovascular coil embolization and microsurgical clipping are now firmly established as treatment options for the management of cerebral aneurysms. Moreover, they are sometimes used as complementary approaches each other. This study retrospectively analyzed our experience with endovascular and microsurgical procedures as complementary approaches in treating a single aneurysm. Methods : Nineteen patients with intracranial aneurysm were managed with both endovascular and microsurgical treatments. All of the aneurysms were located in the anterior circulation. Eighteen patients presented with SAH, and 14 aneurysms had diameters of less than 10 mm, and five had diameters of 10-25 mm. Results : Thirteen of the 19 patients were initially treated with endovascular coil embolization, followed by microsurgical management. Of the 13 patients, 9 patients had intraprocedural complications during coil embolization (intraprocedural rupture, coil protrusion, coil migration), rebleeding with regrowth of aneurysm in two patients, residual sac in one patient, and coil compaction in one patient. Six patients who had undergone microsurgical clipping were followed by coil embolization because of a residual aneurysm sac in four patients, and regrowth in two patients. Conclusion : In intracranial aneurysms involving procedural endovascular complications or incomplete coil embolization and failed microsurgical clipping, because of anatomical and/or technical difficulties, the combined and complementary therapy with endovascular coiling and microsurgical clipping are valuable in providing the best outcome.

Optimal Coil Configuration Design Methodology Using the Concept of Equivalent Magnetizing Current (등가자화전류를 이용한 최적코일형상 설계방법)

  • Kim, Woo-Chul;Kim, Min-Tae;Kim, Yoon-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.43-49
    • /
    • 2007
  • A new electric coil design methodology using the notion of topology optimization is developed. The specific design problem in consideration is to find optimal coil configuration that maximizes the Lorentz force under given magnetic field. Topology optimization is usually formulated using the finite element method, but the novel feature of this method is that no such partial differential equation solver is employed during the whole optimization process. The proposed methodology allows the determination of not only coil shape but also the number of coil turns which is not possible to determine by any existing topology optimization concept and to perform single coil strand identification algorithm. The specific applications are made in the design of two-dimensional fine-pattern focusing coils of an optical pickup actuator. In this method, the concept of equivalent magnetizing current is utilized to calculate the Lorentz force, and the optimal coil configuration is obtained without any initial layout. The method is capable of generating the location and shape of turns of coil. To confirm the effectiveness of the proposed method in optical pickup applications, design problems involving multipolar permanent magnets are considered.