• 제목/요약/키워드: Coefficient of performance(COP)

검색결과 225건 처리시간 0.022초

하이브리드 지중열교환기 적용 히트펌프 시스템의 냉방 성능 분석 (Cooling Performance Analysis of Ground-Source Heat Pump (GSHP) System with Hybrid Ground Heat Exchanger (HGHE))

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.43-52
    • /
    • 2018
  • This paper presents the cooling performance analysis results of a ground-source heat pump (GSHP) system using hybrid ground heat exchanger (HGHE). In this paper, the HGHE refers to the ground heat exchanger (GHE) using both a vertical GHE and a surface water heat exchanger (SWHE). In order to evaluate the system performance, we installed monitoring sensors for measuring temperatures and power consumption, and then measured operation data with 4 different load burdened ratios of the hybrid GHE, Mode 1~Mode 4. The measurement results show that the system with HGHE mainly operates in Mode 1 and Mode 2 over the entire measurement period. The average cooling coefficient of performance (COP) for heat pump unit was 5.18, while the system was 2.79. In steady state, the heat pump COP was slightly decreased with an increase of entering source temperature. In addition, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further research are needed to optimize the design data for various load ratios of the HGHE.

자동차용 에어컨 압축기의 성능 향상에 대한 연구 (Study of Compressor-Performance Improvement in Automotive Air-Conditioning System)

  • 김영신;유성연;나승규
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.713-718
    • /
    • 2015
  • 본 연구의 목적은 자동차용 에어컨 시스템의 연비 개선을 위하여 압축기의 성능 향상을 도모하고자 하는데 있다. 압축기 성능은 자동차용 에어컨 압축기 전용 열량계를 이용하여 평가를 수행하였다. 압축기의 성능을 향상시키기 위하여 흡입 유량의 증대와 토출 사체적 축소를 검토하였으며, 각 개선 항목에 대한 평가를 진행하여 성능과 COP 의 개선을 확인하였다. 흡입 유량을 증대했을 경우 저속 구간보다 고속구간에서의 성능 효과가 컸으며, 토출 사체적을 축소했을 경우 상대적으로 저속 구간의 성능 개선효과가 컸다. 조합품의 경우 저속과 고속에서 전반적으로 균형 있게 개선되었으며, 토출측 온도가 가장 크게 개선되었다. 성능의 경우 저속에서 약 3.2%, 고속에서 약 8.3% 개선되었으며, COP 는 저속에서 약 5.8%, 고속에서 약 6.2% 개선되었고, 토출 온도는 저속에서 $3^{\circ}C$, 고속에서 $5^{\circ}C$ 개선되었다.

탄화수소계 냉매 R-290을 사용하는 냉동.공조 장치의 사이클 특성에 관한 연구 (Cycle performance of refrigeration and air-conditioning system using the hydrocarbon refrigerant R-290)

  • 박기원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.447-452
    • /
    • 1999
  • This paper describes the cycle performance of heat-pump system using R-22 and R-290. Experiments were performed in the smooth tube with inside diameter of 10.07mm and outside diameter of 12.07 mm and grooved inner tube having 75 fins with a height of 0.25mm Condensing temperatures were held constantly between 318K and 328 K while evaporating temperatures were varied from 257 K to 288 K mass velocities from 51 to $280 kg/m^2s$. From the experiments it was known that the evaporating temperature and condensing temperature had more affected by the compressor shaft power than the tube geometries. Cooling capacity of the R-22 and R-290 had similar values in the smooth and grooved inner tubes. The coefficient of performance(COP) was calculated using the compressor shaft power volumetric refrigeration capacity compression ratio and cooling capacity. The COP of the R-290 had slightly higher values than that of R-22 The major parameters affecting the heat pump cycle performance wee the refrigerant proper-ties and operating conditions rather than the geometric shapes of the heat exchanger

  • PDF

관정간 도수통로를 설치한 개방형 지열 시스템의 냉방성능 실험 (Performance Analysis for Open-loop Geothermal System with Spill-way technology by Real-scale Experiment)

  • 김홍교;배상무;남유진;전운;오종현;이병호
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.186-194
    • /
    • 2018
  • A ground-source heat pump system (GSHP) is more energy efficient than other heat-source systems because it uses annual constant underground and water temperatures. Especially, two-well geothermal systems using groundwater as the heat source can achieve higher performance than closed-loop geothermal systems. However, performance of two-well geothermal systems is decreased by occurring overflow according to scale during long-term operations. Therefore, this study presents a two-well pairing geothermal system that controls the groundwater level of a diffusion well. In addition, a two-well pairing geothermal system and an SCW geothermal system were installed, and a comparative analysis of cooling performance depending on system operation under the same load conditions was conducted. The result was that the average heat pump coefficient of performance (COP) of the two-well pairing system was 6.5, and the entire system COP was 4.3.

The Control of Superheat and Capacity for a Variable Speed Refrigeration System Based on PI Control Logic

  • Hua, Li;Jeong, Seok-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권2호
    • /
    • pp.54-60
    • /
    • 2007
  • In this paper, we suggest the high efficient control method based on general PI control law for a variable speed refrigeration system. In the variable speed refrigeration system, the capacity and the superheat are mainly controlled by an inverter and an electronic expansion valve, respectively, for saving energy and improving coefficient of performance. Thus, we proposed a decoupling model to eliminate the interfering loop between the capacity and superheat at first. Next, we designed PI controller to control the capacity and superheat independently and simultaneously. Finally, the control performance was investigated through some experiments. The experimental results showed that the proposed PI controller based on the decoupling model can obtain good control performance under the various control references and thermal load.

개방형 지열히트펌프 시스템의 성능평가 (Performance Evaluation of Open-Loop Ground Water Heat Pump system)

  • 김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.9-14
    • /
    • 2006
  • Open loop or ground water heat pump systems are the oldest of ground-source systems. Standing column wells can be used as highly efficient ground heat exchanger in geo-thermal heat pump systems, where hydrological and geological conditions are suitable. These systems require some careful considerations for well design, ground water flow, heat exchanger selection etc This paper describes 9round water temperature variations, performances in heat ins and cool ing mode and the results of ground water analysis.

  • PDF

트윈 로타리 압축기의 행정 체적비가 압축기 성능에 미치는 영향 (Effect of displacement volume ratio on compressor performance for a twin rotary compressor)

  • 안종민;김현진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.171-176
    • /
    • 2008
  • As one way of design optimization of two-stage two-cylinder rotary compressor used for R410A heat pump application, displacement volume ratio, being defined by the ratio of the second stage cylinder volume to that of the first stage, has been varied and its effect on the compressor performance has been investigated by a computer simulation program. For simplicity, only the cylinder height of the second stage was varied to change the volume ratio. With increasing the volume ratio in the range of VR=$0.55{\sim}0.9$, volumetric efficiency increased monotonically, but adiabatic efficiency showed a maximum at around VR=0.6. Mechanical efficiency was little influenced by the volumetric ratio. As a consequence, maximum improvement of the compressor performance was found at around VR=0.7. Compared to a one-stage two-cylinder rotary compressor with about the same cooling capacity, COP improvement was about 6.96%.

  • PDF

이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구 (Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions)

  • 손동진;백창현;허재혁;강훈;김용찬
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.273-280
    • /
    • 2011
  • In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.

응축수를 이용한 이동식 에어컨의 성능특성에 관한 연구 (A Study of Performance Characteristics on Portable Air Conditioner by Using Condensation Water)

  • 김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.762-767
    • /
    • 2012
  • 본 연구는 실내외기가 일체화된 이동식 에어컨을 대상으로 장치 운전 중 발생되는 응축수를 응축기에 분사한 경우, 응축수가 장치의 성능특성에 미치는 영향을 파악한 연구이다. 연구 결과 응축기 입출구 냉매온도 및 출구 공기온도는 응축수를 이용하지 않는 기존방식에 비해 낮게 유입 및 유출되어 응축수에 의해 상당한 응축부하가 처리되는 것을 알 수 있었다. 또한 동일한 조건에서 장치의 냉동능력과 성능계수는 평균 약 3%, 13~16%정도 높게 나타났으며, 압축기 소비동력 또한 약 27%정도 낮게 나타나응축수를 이용한 경우가 주기적인 응축수 배출에 따른 문제점 해결 이외에도 장치의 성능향상에 크게 기여하는 결과를 얻을 수 있었다.

탄화수소계 냉동공조 시스템의 성능특성에 관한 실험 (Performance Characteristics of Refrigeration and Air Conditioning System Using Hydrocarbon Refrigerants)

  • 이호생;이근태;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.728-734
    • /
    • 2004
  • Environmentally friendly refrigerants with zero ozone layer depletion potential are required to be used in refrigerators and air conditioners due to the difficulties related to ozone layer depletion and global warming. A rigorous study for the system performance with new refrigerants having zero ozone layer depletion potential is inevitable before adopting that as a new fluid. The HFC(Hydrofluorocarbon) potential has been recommended as alternatives. In this paper. system performance in the heat pump facilities were studied using R-290, R-600a. R-1270 as an environment friendly refrigerant. R-22 as a HCFC's refrigerant. The experimental apparatus has been set-up as a conventional vapor compression type heat Pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70mm with 1.315mm wall thickness is used for this investigation. The test results showed that the COP of hydrocarbon refrigerants were superior to that of R-22 and the maximum increasing rate of COP was found in R-1270. The refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. The compressor work was obtained with the maximum value in R-1270 and the minimum one in R-22.