• Title/Summary/Keyword: Coefficient of Variation(CV)

Search Result 249, Processing Time 0.031 seconds

Uniformity Analysis of Unmanned Aerial Application with Variable Rate Spray System (무인항공 변량방제 시스템의 살포 균일도 분석)

  • Koo, Young Mo;Bae, Yeonghwan
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.111-125
    • /
    • 2018
  • In this study, we evaluated the uniformity of deposition rate and particle size distributions of the variable rate application technique using the unmanned rotorcraft by measuring the spray pattern according to path location in the range of spraying flight. The coefficient of variation (CV) of the lateral coverage rate for the overlapped distribution with the spray swath of 3.6 m in both guidance and auto-pilot flight modes maintaining constant flight speed was about 30% and the CV of the coverage rate by the flight path location was extremely small. Therefore, it was assessed that the variable rate application technology compensating for the variation of ground speed was superior in terms of spray uniformity. In addition, the droplet size distributions in both volume median diameter(VMD) and number median diameter(NMD) were adequate for aerial application and uniform in terms of lateral distribution. Thereafter, we intend to contribute to a precise application on small-scaled fields using the unmanned agricultural rotorcraft by the variable rate application.

Exploration and Application of Regulatory PM10 Measurement Data for Developing Long-term Prediction Models in South Korea (PM10 장기노출 예측모형 개발을 위한 국가 대기오염측정자료의 탐색과 활용)

  • Yi, Seon-Ju;Kim, Ho;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.114-126
    • /
    • 2016
  • Many cohort studies have reported associations of individual-level long-term exposures to $PM_{10}$ and health outcomes. Individual exposures were often estimated by using exposure prediction models relying on $PM_{10}$ data measured at national regulatory monitoring sites. This study explored spatial and temporal characteristics of regulatory $PM_{10}$ measurement data in South Korea and suggested $PM_{10}$ concentration metrics as long-term exposures for assessing health effects in cohort studies. We obtained hourly $PM_{10}$ data from the National Institute of Environmental Research for 2001~2012 in South Korea. We investigated spatial distribution of monitoring sites using the density and proximity in each of the 16 metropolitan cities and provinces. The temporal characteristics of $PM_{10}$ measurement data were examined by annual/seasonal/diurnal patterns across urban background monitoring sites after excluding Asian dust days. For spatial characteristics of $PM_{10}$ measurement data, we computed coefficient of variation (CV) and coefficient of divergence (COD). Based on temporal and spatial investigation, we suggested preferred long-term metrics for cohort studies. In 2010, 294 urban background monitoring sites were located in South Korea with a site over an area of $415.0km^2$ and distant from another site by 31.0 km on average. Annual average $PM_{10}$ concentrations decreased by 19.8% from 2001 to 2012, and seasonal $PM_{10}$ patterns were consistent over study years with higher concentrations in spring and winter. Spatial variability was relatively small with 6~19% of CV and 21~46% of COD across 16 metropolitan cities and provinces in 2010. To maximize spatial coverage and reflect temporal and spatial distributions, our suggestion for $PM_{10}$ metrics representing long-term exposures was the average for one or multiple years after 2009. This study provides the knowledge of all available $PM_{10}$ data measured at national regulatory monitoring sites in South Korea and the insight of the plausible longterm exposure metric for cohort studies.

Influence of Site-specific Fertilizer Application Using GPS and Digital Fertility Map on Rice Yield and Quality (전자지도 이용 변량시비가 쌀 수량 및 품질에 미치는 영향)

  • Chi, Jeong-Hyun;Lee, Jae-Hong;Kim, Hee-Oong;Choi, Byoung-Rourl;Park, Jung-Soo;Park, Kyung-Yeol;Jung, In-Gue
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.54 no.2
    • /
    • pp.192-197
    • /
    • 2009
  • This study was conducted to investigate the effect of site-specific variable fertilization following digital fertility map generated from soil analysis on rice growth and yield. The site-specific application of fertilizer was implemented by using rice transplanter equipped with side dressing applicator and global positioning system (GPS). Coefficient of variation (C.V.) of soil nitrogen content was reduced after the experiment, and spatial variation of semivariogram was reduced. Rice growth from tillering to ripening stage, plant height, tiller and panicle number increased at site-specific variable fertilization treatment, and coefficient variation (C.V.) of each growth characteristics was lower than those of conventional fertilization treatment. As a result, fertility in the rice field was more uniform become of site-specific fertilizer application. Head rice yield of site-specific application plot increased by 9% (i.e., to from 450 kg/10a to 492 kg/10a of the control plot) and its CV was significantly reduced to 3.5 compared to 7.8 of the control plot. In addition, there was no significant difference in amylose, protein contents and whiteness of milled rice, but its CV was reduced.

Regional Variation of EQ-5D Index and Related Factors in Community Health Survey: Major Role of Psychosocial Factors in Korea (지역사회건강조사에서 EQ-5D index의 지역간 변이와 관련 요인: 사회심리적 요인의 중요성)

  • Kim, Eunsu;Nam, Hae-Sung
    • Journal of agricultural medicine and community health
    • /
    • v.45 no.4
    • /
    • pp.183-193
    • /
    • 2020
  • Objectives: As an ecological study, this study was performed to identify the community-level variation of health related quality-of-life (HRQOL), and to explore the factors that explain the variation, using 2017 Korean Community Health Survey (KCHS) data. Methods: Community health indicators of KCHS, which are correlated with the EQ-5D index of Si-gun-gu districts, were selected as independent variables. Multiple linear regression model was used to derive factors that explain regional variations in the EQ-5D index. Results: The EQ-5D index variation in 229 districts nationwide was 1.1 times for extremal quotient (EQ) and 1.0 for coefficient of variance (CV). The Si-gun-gu districts with the EQ-5D index in the lower 25% were more distributed in the province (27.7%) than in the metropolitan area (20.3%). As a result of multiple linear regression analysis, the depressed mood experience rate, perceived stress rate, suicide ideation rate, and physician diagnosed arthritis rate were derived as major factors of the variation. Conclusions: In order to reduce the gap in HRQOL between the districts, the priority of local health policies should be placed on the above factors including psychosocial factors.

Analysis of Spray Characteristics of Tractor-mounted Boom Sprayer for Precise Spraying

  • Kim, Ki-Duck;Lee, Hyeon-Seung;Hwang, Seok-Joon;Lee, Young-Joo;Nam, Ju-Seok;Shin, Beom-Soo
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.258-264
    • /
    • 2017
  • Purpose: This study determines the spray characteristics and effective spray width of a tractor-mounted commercial boom sprayer through experiments. Methods: Performance tests were conducted to investigate the spray characteristics of the nozzles on a commercial boom sprayer. The flow rate and spray width of a single nozzle were measured at three levels of spray pressure (0.5, 0.7, and 1.0 MPa) and spray height (15, 30, and 45 cm), respectively. The average value of three repetition tests was used as the representative value. A coefficient of variation (CV) was used as an index of spray uniformity, and the width that guarantees CV values of approximately 15% was determined as the effective spray width. The spray characteristics of the overall boom sprayer were derived analytically by superimposing the spray characteristics of a single nozzle. Results: The test results for a single nozzle showed that the spray width tended to increase as the spray height and spray pressure increased. The effective spray width for a single nozzle was the largest at a spray pressure of 1.0 MPa and spray height of 45 cm, which resulted in a coverage of 84 cm of width. The effective spray width for the entire boom sprayer was also the largest at the spray pressure of 1.0 MPa and spray height of 45 cm, with a magnitude of 424.5 cm. The chemical spraying work in an actual field was simulated by applying a spray width of 400 cm. As a result of the operation for three swaths, the CV value was less than 10% for 1,200 cm of the overall spray width, which meant that uniform application was achieved. Conclusions: It was reasonable to set the effective spray width of the boom sprayer used in this study to 400 cm.

Study on Correlation Between the Internal Pressure Distribution of Slit Nozzle and Thickness Uniformity of Slit-coated Thin Films (슬릿 노즐 내부 압력 분포와 코팅 박막 두께 균일도 간의 상관관계 연구)

  • Gieun Kim;Jeongpil Na;Mose Jung;Jongwoon Park
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.19-25
    • /
    • 2023
  • With an attempt to investigate the correlation between the internal pressure distribution of slit nozzle and the thickness uniformity of slot-coated thin films, we have performed computational fluid dynamics (CFD) simulations of slit nozzles and slot coating of high-viscosity (4,800 cPs) polydimethylsiloxane (PDMS) using a gantry slot-die coater. We have calculated the coefficient of variation (CV) to quantify the pressure and velocity distributions inside the slit nozzle and the thickness non-uniformity of slot-coated PDMS films. The pressure distribution inside the cavity and the velocity distribution at the outlet are analyzed by varying the shim thickness and flow rate. We have shown that the cavity pressure uniformity and film thickness uniformity are enhanced by reducing the shim thickness. It is addressed that the CV value of the cavity pressure that can ensure the thickness non-uniformity of less than 5% is equal to and less than 1%, which is achievable with the shim thickness of 150 ㎛. It is also found that as the flow rate increases, the average cavity pressure is increased with the CV value of the pressure unchanged and the maximum coating speed is increased. As the shim thickness is reduced, however, the maximum coating speed and flow rate decrease. The highly uniform PDMS films shows the tensile strain as high as 180%, which can be used as a stretchable substrate.

  • PDF

Evaluation of the Homogeneity of Korean Diagnosis Related Groups (한국형진단명기준환자군 분류체계의 동질성 평가)

  • Kim, Hyung Seon;Lee, Sun Hee;Nam, Chung Mo
    • Health Policy and Management
    • /
    • v.23 no.1
    • /
    • pp.44-51
    • /
    • 2013
  • Background: This study designed to evaluate the homogeneity of Korean diagnosis related group (KDRG) version 3.4 classification system. Methods: The total 5,921,873 claims data submitted to the Health Insurance Review and Assessment Service during 2010 were used. Both coefficient of variation (CV) and reduction in variance of cost were measured for evaluation. This analysis was divided into before and after trimming outliers at the level of adjacent DRG (ADRG), aged ADRG (AADRG) split by age, and DRG split by complication and comorbidity. Results: At the each three level of ADRG, AADRG, and DRG, there were 38.9%, 38.7%, and 30.0% of which had a CV > 100% in the untrimmed data and there were 1.4%, 1.4%, and 1.9% in the trimmed one. Before trimming outliers, ADRGs explained 52.5% of the variability in resource use, AADRGs did 53.1% and DRGs did 57.1%. The additional explanatory power by age and comorbidity and complication (CC) split were 0.6%p and 4.6%p for each, which were statistically significant. After trimming outliers, ADRGs explained 75.2% of the variability in resource use, AADRGs did 75.6%, and DRGs did 77.1%. The additional explanatory power were 0.4%p and 2.0%p for each, which were statistically significant too. Conclusion: The results demonstrated that KDRG showed high homogeneity within groups and performance after trimming outliers. But there were DRGs CV > 100% after age or CC split and the most contributing factor to high performance of KDRG was the ADRG rather than age or CC split. Therefore, it is recommended that the efforts for improving clinical homogeneity of KDRG such as review of the hierarchical structure of classification systems and classification variables.

Delayed Deproteinization Causes Methodological Errors in Amino Acid Levels in Plasma Stored at Room Temperature or -20℃

  • Li, Junyou;Piao, Chunxiang;Jin, Huazi;Wongpanit, Kannika;Manabe, Noboru
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.12
    • /
    • pp.1703-1708
    • /
    • 2009
  • Deproteinization has been recognized as a prerequisite for amino acid analysis of plasma samples. For plasma stored at room temperature, delaying deproteinization for 30, 60 or 120 minutes did not result in significant changes in the mean CV (coefficient of variation), which ranged from 4.4 to 5.6%. However the mean CV of aspartic acid, ${\alpha}$-aminoadipic acid, alanine and lysine was about 10%. When the plasma was stored frozen at -20${^{\circ}C}$, the CV was increased at 0 and 120 minutes after thawing, to 12.4% (range, 4.1 to 35.3%) and 8.0% (2.5 to 30.7%), respectively. The concentrations in plasma during storage at room temperature of all the amino acids analyzed showed significant changes. In plasma stored for 30 minutes at room temperature, 17 amino acids increased in concentrations and two decreased. Extending this period to 60 or 120 minutes increased the instability as compare to the reference group. Storing plasma at -20${^{\circ}C}$ for 2 weeks resulted in significantly greater changes in the amino acid concentrations than at room temperature. On extending the storage time at room temperature, after thawing, to 30, 60, and 120 minutes, 21, 20, and all 22 amino acids respectively changed significantly (p<0.01). The present study indicates that methodological errors occur in the concentrations determined for all amino acids when plasma is left at room temperature. The storage of frozen non-deproteinized plasma accompanied more significant changes in most amino acid concentrations and thus should be avoided. Deproteinization should be performed as soon as possible after plasma collection.

Involvement of EMG Variables and Muscle Characteristics in Force Steadiness by Level (수준별 힘 안정성에 대한 EMG 변인 및 근육 특성의 관여)

  • Hyeon Deok Jo;Maeng Kyu Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.336-345
    • /
    • 2023
  • The present study was designed to evaluate changes in neuromuscular properties and the structural and qualitative characteristics of muscles during submaximal isometric contractions at low-to-relatively vigorous target forces and to determine their influence on force steadiness (FS). Thirteen young adult males performed submaximal isometric knee extensions at 10, 20, 50, and 70% of their maximal voluntary isometric contraction using their non-dominant legs. During submaximal contractions, we recorded force, EMG signals from vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF), and ultrasound images from the distal RF (dRF). Force and EMG standard deviation (SD) and coefficient of variation (CV) values were used to measure FS and EMG steadiness, respectively. Muscle thickness (MT), pennation angle (PA), echo intensity (EI), and texture features were calculated from ultrasound images to assess the structural and qualitative characteristics of the muscle. FS, neuromuscular properties, and texture features showed significant differences across different force levels. Additionally, there were significant differences in EMG_CV among the quadriceps at the 50% and 70% force levels. The results of correlation analysis revealed that FS had a significant relationship with EMG_CV in VM, VL, and RF, as well as with the texture features of dRF. This study's findings demonstrate that EMG steadiness and texture features are influenced by the magnitude of the target force and are closely related to FS, indicating their potential contribution to force output control.

An Efficient Estimation of Local Area Unemployment Rate Based on Small Area Estimation (소지역 추정법을 이용한 효율적인 지역 실업률 추정)

  • Kim, Soo-Taek
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.6
    • /
    • pp.1129-1138
    • /
    • 2011
  • Small area estimation has received significant intention in recent years due to a growing demand for reliable local area statistics. Traditional area-specific direct estimates based solely on sample survey data in the areas of interest do not provide adequate small area precision; however, design-based indirect local area estimators borrow strength from sample observations of related areas to increase the effective sample size. Design-based indirect estimation methods such as synthetic and composite estimators are considered to adjust local area unemployment rate estimates in the Korean Economically Active Population Survey. This study suggests an efficient alternative to minimize the cost to construct the unemployment rate of a local area through simulation under the condition that we can maintain a certain level of CV for the estimates. We obtained the results that the composite estimators using a sample size greater than 10 are more stable and significant at the level of CV 25% in our design scheme.