• Title/Summary/Keyword: Coefficient

Search Result 30,167, Processing Time 0.062 seconds

Identification of Flavonoids from Extracts of Opuntia ficus-indica var. saboten and Content Determination of Marker Components Using HPLC-PDA (손바닥선인장 추출물의 플라보노이드 구조 규명 및 HPLC-PDA를 이용한 지표성분의 함량 분석)

  • Park, Seungbae;Kang, Dong Hyeon;Jin, Changbae;Kim, Hyoung Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.2
    • /
    • pp.210-219
    • /
    • 2017
  • This study aimed to establish an optimal extraction process and high-performance liquid chromatography (HPLC)-photodiode array (PDA) analytical method for determination of marker compounds, dihydrokaempferol (DHK) and 3-O-methylquercetin (3-MeQ), as a part of materials standardization for the development of health functional foods from stems of Opuntia ficus-indica var. saboten (OFS). The quantitative determination method of marker compounds was optimized by HPLC analysis, and the correlation coefficient for the calibration curve showed very good linearity. The HPLC-PDA method was applied successfully to quantification of marker compounds in OFS after validation of the method in terms of linearity, accuracy, and precision. Ethanolic extracts from stems of O. ficus-indica var. saboten (OFSEs) were evaluated by reflux extraction at 70 and $80^{\circ}C$ with 50, 70, and 80% ethanol for 3, 4, 5, and 6 h. Among OFSEs, OFS70E at $80^{\circ}C$ showed the highest contents of DHK and 3-MeQ of $26.42{\pm}0.65$ and $3.88{\pm}0.29mg/OFS100g$, respectively. Furthermore, OFSEs were determined for their antioxidant activities by measuring 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging and lipid peroxidation (LPO) inhibitory activities in rat liver homogenate. OFS70E at $70^{\circ}C$ showed the most potent antioxidant activities with $IC_{50}$ values of $1.19{\pm}0.11$ and $0.89{\pm}0.09mg/mL$ in the DPPH radical scavenging and LPO inhibitory assays, respectively. To identify active components of OFS, various chromatographic separation of OFS70E led to isolation of 11 flavonoids: dihydrokaempferol, dihydroquercetin, 3-O-methylquercetin, quercetin, isorhamnetin 3-O-glucoside, isorhamnetin 3-O-galactoside, narcissin, kaempferol 7-O-glucoside, quercetin 3-O-galactoside, isorhamnetin, and kaempferol 3-O-rutinoside. The results suggest that standardization of DHK in OFSEs using HPLC-PDA analysis would be an acceptable method for the development of health functional foods.

Evaluation of Fabricated Semiconductor Sensor for Verification of γ-ray Distribution in Brachytherapy (근접치료용 방사성 동위원소의 선량분포 확인을 위한 디지털 반도체 센서의 제작 및 평가)

  • Park, Jeong-Eun;Kim, Kyo-Tae;Choi, Won-Hoon;Lee, Ho;Cho, Sam-Joo;Ahn, So-Hyun;Kim, Jin-Young;Song, Yong-Keun;Kim, Keum-bae;Huh, Hyun-Do;Park, Sung-Kwang
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.280-285
    • /
    • 2015
  • In radiation therapy fields, a brachytherapy is a treatment that kills lesion of cells by inserting a radioisotope that keeps emitting radiation into the body. We currently verify the consistency of radiation treatment plan and dose distribution through film/screen system (F/S system), provide therapy after checking dose. When we check dose distribution, F/S systems have radiation signal distortion because there is low resolution by penumbra depending on the condition of film developed. In this study, We fabricated a $HgI_2$ Semiconductor radiation sensor for base study in order that we verify the real dose distribution weather it's same as plans or not in brachytherapy. Also, we attempt to evaluate the feasibility of QA system by utilizing and evaluating the sensor to brachytherapy source. As shown in the result of detected signal with various source-to-detector distance (SDD), we quantitatively verified the real range of treatment which is also equivalent to treatment plans because only the low signal estimated as scatters was measured beyond the range of treatment. And the result of experiment that we access reproducibility on the same condition of ${\gamma}$-ray, we have made sure that the CV (coefficient of variation) is within 1.5 percent so we consider that the $HgI_2$ sensor is available at QA of brachytherapy based on the result.

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

A Study on the Symptom Distress and Suffering of Five Major Cancer Patients (암질병에 따른 암환자의 불편감과 고통에 관한 연구)

  • Kwon, Mi-Hyoung;Kim, Boon-Han
    • Asian Oncology Nursing
    • /
    • v.3 no.2
    • /
    • pp.145-154
    • /
    • 2003
  • Purpose: The study was to furnish basic raw materials that evaluate the efficacy of meatal care according to the form and the relative importance of symptom distress which most of cancer sufferers have been experienced. For that, an investigation of five diverse major cancer symptom distress made a comparison between symptom distress and degree of suffering. Method: Study subjects were 138 inpatients with stomach cancer, lung cancer, hepatocellular carcinoma(HCC), large intestine cancer and breast cancer, except those in the terminal-stage, in 'H' university hospital in Seoul and 'K' center in Ilsan gathered from November 20, 2002 to February 20, 2003. To measure the correlation between feeling of discomfort and agony caused by cancer, 5 point scale (from zero to four), stood on the basis of Symptom Distress Scale (SDS, Rodes & Watson, 1987), was used for this study and the Cronbach's coefficient alpha was 0.95. Accumulated data was analyzed with SPSS 10.0 for window, also used by ANOVA and Duncan's Multiple Range Test. Pearson's Correlation Analysis. Results: 1. Symptom distress of cancer patients was noted and defined in their severity-fatigue, anorexia, pain, depression, dyspepsia, changing appearance and nausea. The degree of symptom distress was fatigue, dyspepsia, depression, anorexia, pain, changing appearance and the degree of suffering was nausea, pain, anorexia, dyspepsia, vomiting, breathing difficulty, changing appearance and fatigue. 2. Examining the difference of degree of symptom distress in each cancer cases, it takes the precedence of them. First, in case of stomach cancer, depression, pain, vomiting and nausea were shown in sequence. In case of lung cancer depression, pain, sleeping problem, anxiety, changing appearance, inattentiveness and vomiting were showed in sequence, depression, changing appearance, sleeping problem, pain in case of HCC, depression, pain in case of large intestine cancer and lastly in case of breast cancer changing appearance, depression, pain and anxiety were shown in sequence. The category of the degree of symptom distress that has a signifiant difference was anorexia, activity discomfort, fatigue, constipation or diarrhea, breathing difficulty, dyspepsia, caughing, fever or chillness, scotoma and urinary disorder. Verifying the highest degree of symptom distress in each cancer cases, anorexia was 1.94(F=4.00, p<.01) in stomach cancer, activity discomfort was 0.97(F=3.08, p<.01) in lung cancer and HCC, fatigue was 2.32(F=4.64, p<.01) in HCC, constipation or diarrhea was 1.83(F=22.31, p<.001) in large intestine cancer, breathing difficulty was 1.83(F=4.00, p<.01) in lung cancer, dyspepsia was 2.69(F=9.98, p<.001) in stomach cancer, coughing was 1.53(F=20.49, p<.001) in lung cancer, fever or chillness was 1.23(F=6.88, p<.001) in lung cancer, scotoma was 1.20(F=3.02, p<.05) in lung cancer and urinary disorder was 1.54(F=11.56, p<.001) in HCC. 3. Examining the difference degree of suffering on cancer cases, the result was as follows; depression of lung cancer was 1.17(F=3.76, p<.01), anorexia of stomach cancer was 1.61(F=3.89, p<.01), constipation or diarrhea of large intestine cancer was 1.42(F=10.43, p<.001), changing appearance of breast cancer was 1.65(F=5.43, p<.001), breathing difficulty of lung cancer was 2.27(F=18.57, p<.001), dyspepsia of stomach cancer was 1.97(F=13.56, p<.001), coughing of lung cancer was 1.70(F=22.07, p<.001), fever or chillness of lung cancer was 1.13(F=4.41, p<.01), scotoma of lung cancer was 0.87(F=3.34, p<.05), anxiety of lung cancer was 0.87(F=4.50, p<.001) and urinary disorder of HCC was 1.43(F=16.71, p<.001). 4. In consequence, comparing between symptom distress and degree of suffering on cancer patients undergoing chemotherapy, lung cancer patients showed the highest feeling of discomfort following stomach cancer, HCC, breast cancer and large intestine cancer(F=2.88, p<.05). On those undergoing radiotherapy, lung cancer, HCC, breast cancer, large intestine cancer was in sequence(F=3.78, p<.05) and those resisting radiotherapy, lung cancer, HCC, stomach cancer, large intestine cancer and breast cancer was in sequence(F=2.72, p<.05). 5. Correlation between symptom distress and degree of suffering on cancer patients was generally significant. Conclusion: this study not only defines a significant correlation between symptom distress and degree of suffering but also proffers basic data to evaluate the efficient meatal care depending upon diverse spectrums of symptom distress and degree of suffering.

  • PDF

Normative data of penile length in Korean newborns (한국인 신생아 음경 길이에 대한 연구)

  • Kim, Sang Yeob;Jun, Jae Sung;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.944-949
    • /
    • 2008
  • Purpose : As modern society has became more open, interest in healthy internal and external growth has increased, including that pertaining to penile length in children. A micropenis is defined as one where penile length is more than 2 SD (standard deviation) below the mean, and it can be traced back to chromosome and endocrine disorders. The authors executed this study to suggest guidelines for the study of the micropenis and standard information for penile length in Korean newborns. Methods : The subjects of this study were 168 male infants between 37 and 42 weeks of gestational age, none of whom had any complications during pregnancy or birth; each had been born in Daegu Fatima Hospital between February and June 2007. Penile length was measured using conventional stretched penile length measurement (CPLM) and syringe methods. Results : Penile length was $3.02{\pm}0.25cm$ (F=36.467, $R^2=0.180$, P<0.001) when measured with CPLM, and $3.29{\pm}0.26cm$ (F=9.149, $R^2=0.052$, P<0.001) with the syringe method. There was no statistically significant difference in the penile length of newborn infants as a result of taking measurements with the two methods, and both methods showed significance at 0.631 in terms of Pearson's correlation coefficient, at the level of P=0.01. Conclusion : In this study, penile length tended to be longer when gestational age was longer, and a micropenis can be assumed to be one less than 2.5 cm using CPLM and less than 2.8 cm using the syringe method. In the case of a concealed penis, the syringe method is helpful. When a micropenis is assumed, close observation by outpatient department personnel, and additional endocrine and chromosome studies should be undertaken after sufficiently consulting the parents.

Effect of Nutrient Solution Concentration on the Growth and Mineral Uptake of Various Wrap-up Vegetables and Herbs Grown with Mixed Planting in DFT Hydroponics (담액 수경재배 시 양액농도 처리가 혼식한 쌈 채소류와 허브류의 생육과 무기양분 흡수에 미치는 영향)

  • Seo, Tae-Cheol;Rho, Mi-Young;Gang, Nam-Jun;Lee, Seong-Chan;Choi, Young-Hah;Yun, Hyung-Kweon
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.395-406
    • /
    • 2007
  • The twenty seven wrap-up vegetables (13 Compositae, 14 Brassicaceae) and seven herbs (6 Labiatae, 1 Umbelliferae) were cultivated with a deep flow technique (DFT) hydroponic beds and treated with 3 levels of nutrient solution concentrations of 1.2, 2.4, and $3.6dS{\cdot}m^{-1}$ in summer and autumn season. The pH and electrical conductivity (EC) change of nutrient solution, fresh weight, and mineral contents of plants were investigated. The pH was maintained lower in high electrical conductivity (EC) treatment and in summer than autumn. EC of nutrient solution in EC $3.6dS{\cdot}m^{-1}$ treatment increased up to $4.8dS{\cdot}m^{-1}$ during the growing period in summer season. The growth of tested plants showed high variations by plant species and nutrient solution concentrations. The coefficient variation (CV) of the shoot fresh weight of plants was higher in summer than autumn. The growth of Compostiae and herbs was better at EC $1.2dS{\cdot}m^{-1}$, and 14 Brassicaceae was better at EC $2.4dS{\cdot}m^{-1}$ in summer. In autumn, the growth was better at EC $2.4dS{\cdot}m^{-1}$ in all plants except kale 'TBC F1' and red rape 'honchaetae'. In mineral contents, total nitrogen and potassium were higher in autumn than summer. Total nitrogen, potassium, calcium, magnesium were higher in Brassicaceae than others. Iron and manganese, however, were higher in Compositae. As the results, this study suggests that mixed planting of 27 wrap-up vegetables and 7 herbs in DFT hydroponics in two seasons was possible and EC $1.2dS{\cdot}m^{-1}$ in summer and EC $2.4dS{\cdot}m^{-1}$ in autumn be recommended as for the nutrient solution concentration to produce them safely year round.

Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation (온실설비 작동용 태양광발전시스템의 발전 성능 분석)

  • Yoon, Yong-Cheol;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2009
  • For the purpose of reducing the cost for greenhouse operation by acquiring the electric power necessary for it, this study installed a solar photovoltaic system on the roof of the building adjacent to green-houses and experimentally examined the quantity of power generation based on weather conditions. The results of the study are as per the below: The maximum, average and minimum temperature while the experiment was conducted was $0.4{\sim}34.1,\;-6.1{\sim}22.2$, and $-14.1{\sim}16.7^{\circ}C$ respectively, and the solar radiation was $28.8MJ{\cdot}m^{-2}$ (maximum), $14.9MJ{\cdot}m^{-2}$ (average), and $0.6MJ{\cdot}m^{-2}$ (minimum). The quantity of electric power didn't increase in proportion to the quantity of solar radiation and instead, it was almost consistent around 750W. Daily maximum, average and minimum consumption of electric power was 5.2kWh, 2.5kWh and 0kWh respectively. Based on the average electric power consumption of the system used for this experiment, it was sufficient in case the capacity and the working time of a hot blast heater are small, but it was short in case they are big. In case the capacity of the hot blast heater is big, the average electric power quantity will be sufficient for array area $21m^2$, about three times of the present area. In summer when the temperature of the array becomes high, the generation of electric power didn't increase in proportion to the quantity of solar radiation, but this experiment result shows a high correlation between two factors (coefficient of correlation 0.84).

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Reliability Based Stability Analysis and Design Criteria for Reinforced Concrete Retaining Wall (신뢰성(信賴性) 이론(理論)에 의한 R.C.옹벽(擁壁)의 안정해석(安定解析) 및 설계규준(設計規準))

  • Cho, Tae Song;Cho, Hyo Nam;Chun, Chai Myung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.71-86
    • /
    • 1983
  • Current R.C. retaining wall design is bared on WSD, but the reliability based design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the cantilever retaining wall, which is most common type of retaining wall, and also proposes the theoretical bases of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis and design of each part of cantilever retaining wall are derived and the uncertainty measuring algorithms of each equation are also derived by MFOSM using Coulomb's coefficient of the active earth pressure and Hansen's bearing capacity formula. The levels of uncertainties corresponding to these algorithms are proposed appropriate values considering our actuality. The target reliability indices (overturning: ${\beta}_0$=4.0, sliding: ${\beta}_0$=3.5, bearing capacity: [${\beta}_0$=3.0, design for flexure: [${\beta}_0$=3.0, design for shear: ${\beta}_0$=3.2) are selected as optimal values considering our practice based on the calibration with the current R.C. retaining wall design safety provisions. Load and resistance factors are measured by using the proposed uncertainties and the selected target reliability indices. Furthermore, a set of nominal safety factors, allowable stresses, and allowable shear stresses are proposed for the current WSD design provisions. It may be asserted that the proposed LRFD reliability based design criteria for the R.C. retaining wall may have to be incorporated into the current R.C. design codes as a design provision corresponding to the USD provisions of the current R.C. design code.

  • PDF