• Title/Summary/Keyword: Code system

Search Result 6,233, Processing Time 0.032 seconds

A Study on a concatenated RS code and Turbo code for OFDM system over burst noise channel

  • Choi Sang Min;Moon Byung Hyun;Park Jong Soo
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.649-652
    • /
    • 2004
  • In this paper, a concatenated RS and Turbo code is proposed for OFDM system over burst error channel. The concatenated code used in this study is a RS(255,2D2) code and a rate 1/2 turbo code. The turbo code uses 2 recursive systematic convolutional (RSC) code as the constituent codes and the parity bit are punctured to get the desired code rate. It is shown by simulation that the conventional OFDM system fails when there exists burst noise. The concatenated RS and turbo code obtains at least 5dB gain over the turbo code at the bit error probability of $10^{-3}$.

  • PDF

The Concatenated Coding Scheme for OFDM system over burst noise channel

  • Byung-Hyun, Moon;Sang-Min, Choi
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.9 no.2
    • /
    • pp.17-22
    • /
    • 2004
  • In this paper, a concatenated RS and Turbo code is proposed for OFDM system over burst error channel. The concatenated code used in this study is a RS(255,202) code and a rate 1/2 turbo code. The turbo code uses 2 recursive systematic convolutional (RSC) code as the constituent codes and the parity bit are punctured to get the desired code rate. It is shown by simulation that the conventional OFDM system fails when there exists burst noise. The concatenated RS and turbo code obtains at least 5dB gain over the turbo code at the bit error probability of 10/sup -3/.

  • PDF

A System of Multi RFID code Identification Translation using Ontology (온톨로지를 이용한 다중 RFID 코드 식별 변환 시스템)

  • Byun, Ji-Yung;Yang, Moon-seok;Cha, Ji-Yun;No, Young-sik;Byun, Young-cheol
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.591-594
    • /
    • 2008
  • Currently RFID code systems are classified into ISO, EPC, uCode, KKR code, Mobile RFID code, and etc. According to RFID code systems, RFID system is changed. For various RFID code systems, it's difficult to make it to the network and permanence of RFID business. And the existing system isn't add new RFID code systems to RFID system, and change it efficiently. This paper is proposed to a system of Multi RFID code Identification Translation using Ontology. This system is able to identify code data from RFID reader using ontology build into the identifier info and translation info of RFID code systems, and translate to URN data. Therefore in case of extending and changing RFID code systems, we can add and change the identifier info and translation info of RFID code systems in ontology.

  • PDF

A Study of Construction Quality Management System using QR code (QR코드를 활용한 품질경영시스템에 관한 연구)

  • Park, Sang-Min;Lim, Tae-Kyung;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.137-139
    • /
    • 2012
  • This paper presents a system architecture and database of construction quality management system which encourages real time information tracking and monitoring. It improves the real time quality record tracking by using QR code technology in the project delivery. The advantages and issues relative to QR code and the database structures of the tracking system are presented. Conventional project scheduling system, operation modeling and analysis system, and quality management system are hybridized using QR code technology. The system improves project quality management by tracking the atomic tasks which consists of a construction process at the lowest level of construction hierarchy. It analyzes the quality records to determine the causes of abnormality and/or nonconformity. Using QR code technology, the construction quality management system may be more effective than the conventional one. It was confirmed that the quality management processes in construction project delivery can be more visible and controllable by integrating QR code technology, project scheduling system, and quality management system.

  • PDF

Separation of Kernel Space and User Space in Zephyr Kernel (Zephyr 커널에서 커널 공간과 사용자 공간의 분리 구현)

  • Kim, Eunyoung;Shin, Dongha
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.4
    • /
    • pp.187-194
    • /
    • 2018
  • The operating system for IoT should have a small memory footprint and provide low power state, real-time, multitasking, various network protocols, and security. Although the Zephyr kernel, an operating system for IoT, released by the Linux Foundation in February 2016, has these features but errors generated by the user code can generate fatal problems in the system because the Zephyr kernel adopts a single-space method that both the user code and kernel code execute in the same space. In this research, we propose a space separation method, which separates kernel space and user space, to solve this problem. The space separation that we propose consists of three modifications in Zephyr kernel. The first is the code separation that kernel code and user code execute in each space while using different stacks. The second is the kernel space protection that generates an exception by using the MPU (Memory Protection Unit) when the user code accesses the kernel space. The third is the SVC based system call that executes the system call using the SVC instruction that generates the exception. In this research, we implemented the space separation in Zephyr v1.8.0 and evaluated safety through abnormal execution of the user code. As the result, the kernel was not crashed by the errors generated by the user code and was normally executed.

Evaluation of the Bar Code Medication Administration and Blood Transfusion System in a Tertiary Hospital (투약.수혈 바코드 시스템 적용 평가)

  • Cho, Myung-Sook;Song, Mi-Ra;Jang, Mi-Ra
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.18 no.1
    • /
    • pp.23-32
    • /
    • 2012
  • Purpose: The purpose of this study was to assess the clinical application of a bar code medication administration and blood transfusion system and to identify its effects from the aspect of patient safety and nurse satisfaction in a tertiary hospital. Methods: The system in this study was PDA with bar code reading capability and wireless networking function. The logs created during application of the system and administration error reports were analyzed. For nurses' satisfaction with the system, data were collected from 337 nurses using the instrument developed by Otieno et al. and analyzed using descriptive statistics. Results: The system application rate was 98.8%, and the main failure cases in the system application included bar code or network related factors. When the system was applied, 0.02% of errors were prevented. The nurses were satisfied with the system from the aspect of patient safety, however relatively less satisfied with the system from the aspect of work efficiency. Conclusion: The results of the study indicate the usefulness for patient safety of applying the bar code medication administration and blood transfusion system to clinical practice. However technological improvements including bar code and network communication are necessary to ensure higher work efficiency in nursing practice.

Research on the PAPR Reduction Method using Selection of Extra Code Set in PB/MC-CDMA System (PB/MC-CDMA 시스템에서 여분의 코드집합을 이용한 PAPR 감쇄기법에 관한 연구)

  • Lee, Kyu-Jin;Lee, Dong-Joon;Lee, Kye-San;Kim, Jin-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.1
    • /
    • pp.110-118
    • /
    • 2009
  • The PB/MC-CDMA(Partial Block Multi Carrier Code Division Multilple Access) system can improve the performance by reducing the ICI(Inter-Code Interference) between users. Also, this system can achieve the frequency diversity gain by avoiding ISI(Inter Symbol Interference). Therefore, the performance of PB/MC-CDMA system is better than that of conventional MC-CDMA(Multi Carrier Code Division Multiple Access) system. However, similarly to other multi-carrier systems, it still has a PAPR(Peak to Average Power Ratio) issue. In this paper, we propose a peak power reduction technique involving optimized spreading code selection without side information for the PB/MC-CDMA. The PB/MC-CDMA system in each block of units reuses the code so the extra code will be remained. This extra code is divided into several groups to calculate the PAPR and solving the PAPR problem by transferring the selected code which has minimum peak power.

  • PDF

Verification of SPACE Code with MSGTR-PAFS Accident Experiment (증기발생기 전열관 다중파단-피동보조급수냉각계통 사고 실험 기반 안전해석코드 SPACE 검증)

  • Nam, Kyung Ho;Kim, Tae Woo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.84-91
    • /
    • 2020
  • The Korean nuclear industry developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code and this code adpots two-phase flows, two-fluid, three-field models which are comprised of gas, continuous liquid and droplet fields and has a capability to simulate three-dimensional model. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for accident management plan of nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification work for separate and integral effect experiments is required. In this reason, the goal of this work is to verify calculation capability of SPACE code for multiple failure accident. For this purpose, it was selected the experiment which was conducted to simulate a Multiple Steam Generator Tube Rupture(MSGTR) accident with Passive Auxiliary Feedwater System(PAFS) operation by Korea Atomic Energy Research Institute (KAERI) and focused that the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The MSGR accident has a unique feature of the penetration of the barrier between the Reactor Coolant System (RCS) and the secondary system resulting from multiple failure of steam generator U-tubes. The PAFS is one of the advanced safety features with passive cooling system to replace a conventional active auxiliary feedwater system. This system is passively capable of condensing steam generated in steam generator and feeding the condensed water to the steam generator by gravity. As the results of overall system transient response using SPACE code showed similar trends with the experimental results such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it could be concluded that the SPACE code has sufficient capability to simulate a MSGTR accident.

Numerical Algorithm for Phase Offsets of Binary Codes in the Code Division Multiple Access System

  • Park, Hong-Goo
    • ETRI Journal
    • /
    • v.28 no.2
    • /
    • pp.227-230
    • /
    • 2006
  • There has been a growing need for increased capacity in cellular systems. This has resulted in the adoption of the code division multiple access (CDMA) system as a multiple channel access method. Thus, it is important to obtain the phase offsets of binary codes in the CDMA system because distinct phase offsets of the same code are used to distinguish signals received at the mobile station from different base stations. This letter proposes an efficient algorithm to compute the phase offset of a binary code in the CDMA system through the use of the basic facts of number theory and a new notion of the subcodes of a given code. We also formulate the algorithm in a compact form.

  • PDF

Performance Analysis of Multirate MC-CDMA Systems using OVSF Code Grouping (OVSF 코드그룹화를 이용한 다중전송률 MC-CDMA 시스템의 성능분석)

  • Kim, Nam-Sun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12C
    • /
    • pp.1135-1142
    • /
    • 2006
  • This article presents a new asynchronous MC-CDMA system to implement multiple data rate communications. In a W-CDMA downlink, the OVSF code is used for spreading code for various multimedia traffic. Proposed system utilizes the OVSF code that generated by generation property for spreading. The proposed MC-CDMA system use different lengths of OVSF code as a spreading code according to their data rate. The groupwise processing is accomplished by code grouping in OVSF code generation tree. Between each group, the code grouping interference canceller is performed to cancel other group interference. At that time the proposed receiver does not require any information about interference users. For the analysis of average BER performance, we propose system model and computer simulation were used. We also compare the system performance with that of a single rate MC-CDMA system used orthogonal code as a spreading code.