• Title/Summary/Keyword: Code & standard

Search Result 1,438, Processing Time 0.028 seconds

An Automatic Identification System of Biological Resources based on 2D Barcode and UCC/EAN-128 (2차원 바코드와 UCC/EAN-128을 이용한 생물자원 자동인식시스템)

  • Chu, Min-Seok;Ryu, Keun-Ho;Kim, Jun-Woo;Kim, Hung-Tae;Han, Bok-Ghee
    • The KIPS Transactions:PartD
    • /
    • v.15D no.6
    • /
    • pp.861-872
    • /
    • 2008
  • As rapid development of computing environment, field of automatic identification research which interoperates with various physical objects and digital information is making active progress. Although the automatic identification system is widely used in various industries, application of automatic identification system in the field of medical health doesn't reach other industry. Therefore research in medical health supplies such as medical equipment, blood, human tissues and etc is on progress. This paper suggests the application of automatic identification technology for biological resources which is core research material in human genome research. First of all, user environment requirements for the introduction of automatic identification technology are defined and through the experiments and research, barcode is selected as a suitable tag interface. Data Matrix which is 2D barcode symbology is chosen and data schema is designed based on UCC/EAN-128 for international defecto standard. To showapplicability of proposed method when applied to actual environment, we developed, tested and evaluated application as following methods. Experiments of barcode read time at 196 and 75 below zero which is actual temperature where biological resources are preserved resulted read speed of average of 1.6 second and the data schema satisfies requirements for the biological resources application. Therefore suggested method can provide data reliability as well as rapid input of data in biological resources information processing.

Radiological Characterization of the High-sensitivity MOSFET Dosimeter (고감도 MOSFET 선량계 방사선학적 특성 연구)

  • Cho Sung Koo;Kim Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.215-219
    • /
    • 2004
  • Due to their excellence for the high-energy therapy range of photon beams, researchers show increasing interest in applying MOSFET dosimeters to low- and medium-energy applications. In this energy range, however, MOSFET dosimeter is complicated by the fact that the interaction probability of photons shows significant dependence on the atomic number, Z, due to photoelectric effect. The objective of this study is to develop a very detailed 3-dimensional Monte Carlo simulation model of a MOSFET dosimeter for radiological characterizations and calibrations. The sensitive volume of the High-Sensitivity MOSFET dosimeter is very thin (1 ${\mu}{\textrm}{m}$) and the standard MCNP tallies do not accurately determine absorbed dose to the sensitive volume. Therefore, we need to score the energy deposition directly from electrons. The developed model was then used to study various radiological characteristics of the MOSFET dosimeter. the energy dependence was quantified for the energy range 15 keV to 6 MeV; finding maximum dependence of 6.6 at about 40 keV. A commercial computer code, Sabrina, was used to read the particle track information from an MCNP simulation and count the tracks of simulated electrons. The MOSFET dosimeter estimated the calibration factor by 1.16 when the dosimeter was at 15 cm depth in tissue phantom for 662 keV incident photons. Our results showed that the MOSFET dosimeter estimated by 1.11 for 1.25 MeV photons for the same condition.

  • PDF

A Case Study on Quick Response (QR) Codes and Satisfaction in the Management of Public Records (공공기관 기록물관리에서의 QR코드 도입사례와 이용만족도 연구)

  • Hong, Deok-Yong
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.18 no.3
    • /
    • pp.145-163
    • /
    • 2018
  • The act was designed to identify the introductory cases of the use of quick response (QR) codes in records management by public institutions and propose measures to enhance users' satisfaction with their work. This study looked at the definition of the QR codes and the user services that can be provided by the records depository and reviewed the introduction cases using the codes. The reason QR codes are used by records depositors is that public institutions currently have a single-person system that specializes in records management. With the number of employees and the number of records becoming more extensive, explaining the contents of all tasks accurately as well as other professional contents to employees who lack understanding of the records management life cycle is becoming more difficult. The introductory cases were divided into information on how to register nonelectronic records, information on location and history of important records and administrative museum, and education on standard records management. The research was conducted by dividing the research team's "Records Management Guide" (QR code status) into experimental groups and control groups for officials of the Busan Metropolitan Government. There were significant differences in the level of satisfaction with records management guidance depending on whether or not QR codes were used. When the first and second surveys were compared in December 2017 and March 2018, the results of the first survey averaged 2.94, but the second survey showed high results at 3.75 and was statistically significant. This can be said to be more satisfactory by introducing QR codes than guidance provided by existing type. Although this research examines introductory cases of records management by public institutions using QR codes and user satisfaction, future tasks are to be applied to Records Management System and document production systems so that completion can be improved.

Trends in Korean Pediatric Poisoning Patients: Retrospective Analysis of National Emergency Department Information System (한국 소아청소년 중독 환자의 경향: 국가응급진료정보망을 이용한 후향적 연구)

  • Lee, Kyeongjae;Kim, Kyung Hwan;Shin, Dong Wun;Park, Junseok;Kim, Hoon;Jeon, Woochan;Park, Joon Min;Kim, Hyunjong
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.2
    • /
    • pp.69-78
    • /
    • 2017
  • Purpose: This study reports the clinical features of infant, child, school aged and adolescent patients treated for acute poisoning in nationwide emergency departments (EDs). Methods: We retrospectively analyzed clinical data pertaining to patients under 19 years of age who were treated for acute poisoning in nationwide EDs from 2013 to 2015. The data were collected by the National Emergency Department Information System (NEDIS). All patients were divided into three groups: 'Infant and child group' (0 to 5 years), 'school age group' (6 to 12 years) and 'adolescent group' (13 to 18 years). General characteristics, Korea Standard Classification of Disease $7^{th}$ (KCD-7) codes and results of care were collected. Results: There were 14,500 pediatric poisoning cases during the study period. The distribution of patient age was bimodal with two peaks among infant, child and adolescent group. The proportion of alert mentality at the ED visit of the infant and child group was 99.3%, while that of the adolescent group was 86.4%. The proportion of intentional intoxication was higher in the adolescent group (40.7%) than other age groups. Among children less than 13 years of age, various poisonous substances and therapeutic drugs were common. Conclusion: There were some clinical differences in acute poisoning patients between age groups. It is necessary to establish a preventive plan considering characteristics by age. Since the KCD-7 code has limitations in analyzing the characteristics of poisoning patients, it is necessary to consider the registration system of poisoning patients.

Design and Implementation of an HNS Accident Tracking System for Rapid Decision Making (신속한 의사결정을 위한 HNS 사고이력관리시스템 설계 및 구현)

  • Jang, Ha-Lyong;Ha, Min-Jae;Jang, Ha-Seek;Yun, Jong-Hwui;Lee, Eun-Bang;Lee, Moon-jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.2
    • /
    • pp.168-176
    • /
    • 2017
  • HNS accidents involve large-scale fires and explosions, causing numerous human casualties and extreme environmental pollution in the surrounding area. The widespread diffusion of effects should be prevented through rapid decision making. In this study, a high-quality, standardized, and digitized HNS accident databases has been generated based on the HNS standard code proposed. Furthermore, the HNS Accident Tracking System (HATS) was applied and implemented to allow for systematic integration management and sharing. In addition, statistical analysis was performed on 76 cases of domestic HNS accident data collected over 23 years using HATS. In Korea, an average of 3.3 HNS accidents occurred each year and major HNS accident factors were Springs (41 %), Aprons (51 %), Chemical Carriers (49 %), Crew's Fault (45 %) and Xylenes (12 %). (The number in parentheses is the percentage of HNS accident factors for each HNS accident classification)

Simulation of the High Frequency Hyperthermia for Tumor Treatment (종양치료용 고주파 열치료 인체적용 시뮬레이션)

  • Lee, Kang-Yeon;Jung, Byung-Geun;Kim, Ji-won;Park, Jeong-Suk;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.257-263
    • /
    • 2018
  • Hyperthermia supplies RF high-frequency energy above 1MHz to the tumor tissue through the electrodes. And the temperature of the tumor tissue is increased to $42^{\circ}C$ or more to cause thermal necrosis. A mathematical model can be derived a human body model for absorption and transmission of electromagnetic energy in the human model and It is possible to evaluate the distribution of temperature fields in biological tissues. In this paper, we build the human model based on the adult standard model of the geometric shape of the 3D model and use the FVM code. It is assumed that Joule heat is supplied to the anatomical model to simulate the magnetic field induced by the external electrode and the temperature distribution was analyzed for 0-1,200 seconds. As a result of the simulation, it was confirmed that the transferred energy progressively penetrates from the edge of the electrode to the pulmonary tumors and from the skin surface to the subcutaneous layer.

Marinelli Beaker Measurement and Self Absorption Correction and Application for Various Environmental Samples in Monte Carlo Simulation (몬테카를로 시뮬레이션에서의 다양한 환경 샘플에 대한 Marinelli 비이커 측정 및 자기 흡수 보정과 적용)

  • Jang, Eun-Sung;Gim, Yang-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.605-611
    • /
    • 2017
  • The structure of the actual detector was computed using the code of the PENELOPE. Using the standard mixed sources (450, 1,000 ml), compare the effectiveness of each energy according to various densities and height of the PENELOPE computer simulation, and calculate the effectiveness of the various environmental specimens and apply them to various environmental specimens to determine the lower limit. The values obtained by the obtained value were obtained by applying the obtained efficiency to the actual environmental specimens and obtaining the lower limit values. The density correction factor is 1.155 g of the density correction factor of $0.4g/cm^3$ (59.54keV), 1.153 (661 keV), $1.06g/cm^3$ 1.064 (1,836.04keV), 1.03, and 1.033. It was confirmed that the radioactivity concentration of environmental samples decreased as the amount of specimen was measured increases, and the MDA value decreased as time measured increases.

On characteristics of environmental correction factors in the South Indian Ocean by Topex/Poseidon satellite altimetric data (Topex/Poseidon 위성의 Altimeter자료를 이용한 남인도양의 환경보정인자 특성에 관한 연구)

  • 윤홍주;김영섭;이재철
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.2
    • /
    • pp.117-128
    • /
    • 1998
  • Topex/Poseidon satellite, launched in Auguest 1992, has provided more 5 years of very good quality data. Efficient improvements, either about instrumental accuracy or about sea level data correction, have been made so that Topex/Poseidon has become presently a wonderful tool for many researchers. The first mission data of 73 cycles, September 1992 - August 1994, was used to our study in order to know characteristics of environmental correction factors in the Amsterdam-Crozet-Kerguelen region of the South Indian Ocean. According to standard procedures as defined under user handbook for sea surface height data processes, then we have chosen cycles 43 as the cycle of reference because this cycle has provided the completed data for measurement points and has presented the exacted position of ground track compared to another cycles. It was computed variations of various factors for correction in ascending ground track 103(Amsterdam-Kerguelen continental plateau) and descending ground track170 (Crozet basin). Here the variations of ionosphere, dry troposphere, humid troposphere, electromagnetic bias, elastic tide and loading tide were generally very smaller as a few of cm, but the variations of oceanic tide(30-35cm) and inverted barometer(15-30cm) were higher than another factors. For the correction of ocean tide, our model(CEFMO: Code d' Elements Finis pour la Maree Oceanique) - This is hydrodynamic model that is very well applicated in all oceanic situations - was used because this model has especially good solution in the coastal and island area as the open sea area. Conclusionally, it should be understood that the variation of ocean free surface is mainly under the influence of tides(>80-90%) in the Amsterdam - Crozet- Kerguelen region of the South Indian Ocean.

A Comparative Study on the Semantic and Functional Appropriateness of the Safety Sign Color Standards in Construction Sites (건설안전표지 색채기준의 의미적·기능적 적절성 판단 및 개선방안 도출을 위한 국가 간 비교법제 연구)

  • Jang, YeEun;Yi, June-Seong
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.1 no.1
    • /
    • pp.22-30
    • /
    • 2018
  • Construction accidents in Korea are continuously increasing. Safety signs with high visibility color can diminish such accidents in dangerous places. In order for safety color to be more effective as a global communication means in construction sites, it needs to be checked out whether safety color standard reflect the characteristics of construction industry such as worker or work environment. This paper compared safety color standards among Korea, the US, the UK, and Australia. First, blue color was included in all, which should be corrected considering aged workers increasing in construction industry. Because with age, the ability to distinguish between blue, purple, and gray colors decreases. Second, Korea, which has only single code designated to safety colors, should find alternatives like tolerance to be applicable to a variety of light environments on construction sites, as the contrast which affect the visibility may decrease in dark conditions.

Service Life Variation for RC Structure under Carbonation Considering Korean Design Standard and Design Cover Depth (국내설계기준과 피복두께를 고려한 RC 구조물의 탄산화 내구수명의 변동성)

  • Kim, Yun-Shik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.15-23
    • /
    • 2021
  • In this paper, service life for RC(Reinforced Concrete) substructure subjective to carbonation was evaluated through deterministic and probabilistic method considering field investigation data and Design Code(KDS 14 20 40). Furthermore changes in service life with increasing COV(Coefficient of Variation) and equivalent safety index meeting the same service life were studied. From the investigation, the mean and its COV of cover depth were evaluated to 70.0 ~ 90.0 mm and 0.2, respectively. With intended failure probability of 10.0 % and 70 mm of cover depth, service life decreased to 137 years, 123 years, and 91 years with increasing COV of 0.05, 0.1, and 0.2, respectively. In the case of 80 mm of cover depth, it changes to 179 years, 161 years, and 120 years with increasing COV. The equivalent safety index meeting the same service life from deterministic method showed 1.66 ~ 3.43 for 70 mm of cover depth and 1.61 ~ 3.24 for 80 mm of cover depth, respectively. The various design parameters covering local environment and quality condition in deterministic method yields a considerable difference of service life, so that determination of design parameters are required for exposure conditions and parameter variation.