• Title/Summary/Keyword: Coaxial

Search Result 1,000, Processing Time 0.028 seconds

A Square Coaxial Transmission Line with a Thin-Wire Inner Conductor to Measure the Absorbing Performance of Electromagnetic Absorbers

  • Kang, Tae-Weon;John Paul;John Paul
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • A low-frequency coaxial reflectometer(LCR) with a thin-wire inner conductor is designed and constructed to measure nondestructively the absorbing performance of electromagnetic absorbers in the frequency range of 10 MHz to 200 MHz. The LCR consists of a square coaxial transmission line and a network analyzer with a time-domain measurement capability. Inherent characteristics of a square coaxial line with a thin-wire inner conductor which deteriorate the impedance matching of the input port of the LCR are addressed. And the characteristics are improved by employing a multiwire inner conductor. Measured and calculated reflection losses of a flat ferrite tile absorber are presented.

The Study of Characteristics of Tubular Type Coaxial Shunt for High Current Measuring System (대전류 측정용 Tubular Coaxial Shunt 특성에 관한 연구)

  • Roh, Chang-Il;La, Dae-Ryeol;Kim, Sun-Koo;Jung, Heung-Soo;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.834-836
    • /
    • 2003
  • This paper describes the optimal design, construction and performance evaluation of coaxial shunts used in high current testing laboratory for current measuring system. These shunts, which are of tubular type coaxial shunts, the currents to be measured range from Amperes to several kiloAmperes, and the frequency of the signals has a bandwidth from DC to megaHertz. The shunt must have the mechanical strength to support the forces produced by the transient current, above all, the measuring capabilities of shunt are dependent upon short response time and it must be as free as possible of inductive effects. In this paper presents both characteristic of shunt and design of tubular type coaxial shunt.

  • PDF

Shield Wire Stripping of Micro Coaxial Cable for Medical Device Using Laser (레이저를 이용한 의료기기용 미세 동축케이블의 실드선 탈피)

  • Lee, Jeong-Wan;Kim, Jung-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.64-71
    • /
    • 2009
  • Recently as ultrasonic medical devices are gradually developed, many of those require smaller and more precision coaxial cables in the probe. So, the use of micro coaxial cable becomes an efficient solution for ultrasonic machine. However, there are many difficulties in stripping micro coaxial cable by traditional mechanical process. In this paper we use the Nd:YAG laser for the efficient striping of conduct wire of cable. Through some experiments, we found that there is a new possibility in the proposed method. Also, we propose a pre-process of the cable before stripping in order to enhance the performance.

Characteristic Analysis of High Speed Coaxial Magnetic Gear by Two-Dimensional Finite Element Analysis (2차원 유한요소 해석을 이용한 고속용 마그네틱 기어의 형상에 따른 특성 해석)

  • Lee, Jeong-In;Shin, Kyung-Hun;Bang, Tae-Kyoung;Lee, Sang-Hwa;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.36-43
    • /
    • 2019
  • In this paper, the characteristics of the coaxial magnetic gear according to the shape of the same gear ratio are analyzed using the two - dimensional finite element analysis. The rotor shape is SMCMG, CPCMG and RCMG. After this we analyzed the characteristics according to three shapes. Also, the amount of permanent magnet used in each shape was compared. Next, characteristics analysis of the magnetic gear according to the shape at the same torque was performed. And the total weight and efficiency of the magnetic gears were compared and verified.

A Study on the Manufacture of the Water Sensor (물방울 감지 센서의 제작에 관한 연구)

  • Kim, Jin Kook;Lee, Yun Min
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.2
    • /
    • pp.37-45
    • /
    • 2014
  • This paper is a study of the water sensor using a coaxial cavity resonator. This water sensor uses the resonant frequency variation of the coaxial cavity resonator when there is a water drop of the used coaxial cavity resonator. And we made resonant frequencies by controlling the input voltage of the oscillator which will be mainly resonated in the coaxial cavity resonator. First, we made the coaxial cavity resonator by simulating the resonator structure with the proposed size and we expect the resonant frequency from the simulation and then we decide the VCO from the result. Second, we made the water drop detecting sensor circuit and measured the water sensor. We decided the size of the resonator as inner conductor 5mm, outer conductor 14mm, the height of resonator 9.5mm, and the height of the glass 6mm from the simulated result. The simulated resonant frequencies are 3.09GHz and we made the VCO frequency ranges from 2.56GHz to 3.2GHz. The measured resonant frequency is 2.97GHz and the return loss is under -8. 4 dB at the center frequency. When the water is dropped on the glass of the resonator, the voltage has changed from 690mV to 145mV. It shows the proposed water sensor can detect the water by the resonant frequency variation of the resonator.

Design of a Compact Coaxial Waveguide Feed Horn for Dual Band (이중 대역 소형 동축 도파관 급전 혼 설계)

  • Yun, Sohyeun;Uhm, Manseok;Yom, Inbok
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.109-113
    • /
    • 2015
  • This paper presents the study results on a dual band feed horn for the focused reflector. A coaxial waveguide structure is attractive to avoid blockage from the feeder. The inner conductor as a hollow waveguide is designed to excite TE11 of a circular waveguide for high frequency. For low frequency, the design of the outer coaxial waveguide that propagates coaxial TE11 and prevents fundamental TEM is presented. The horn size for generation of these modes results in the degradation of performance. The return loss is improved by a capacitive iris and an inductive iris The enhanced pattern symmetry by dual mode is presented. The horn design in this paper are verified through the test.

A Coaxial Waveguide-based Spatial Combiner Using Finline-to-Microstrip Transitions (핀라인-마이크로스트립 변환을 이용한 동축선로 도파관 형태의 공간 결합기)

  • Kim, Bo-Ki;Lee, Su-Hyun;Kim, Hyoung-Jong;Shin, Suk-Woo;Kim, Sang-Hoon;Kim, Jae-Duk;Choi, Jin-Joo;Kim, Seon-Joo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.5
    • /
    • pp.79-86
    • /
    • 2011
  • In this paper, a S-band coaxial waveguide-based spatial combiner is proposed. The proposed combiner consists of coaxial waveguide, impedance transformer, and finline-to-microstrip transformer. The coaxial waveguide is used as the host of the combining circuits for higher output power and better uniformity by equally distributing the input power to each element. The finline-to-microstrip transformer is designed by using antipodal antenna, and obtained low reflection coefficient by applying the small reflection theorem. The measurement results show the coaxial waveguide combiner has a maximum combining efficiency of 95%.

An Experimental Study of the Wall Temperature of the Supersonic Impinging Coaxial Jet Using an FLIR (적외선 카메라를 이용한 초음속 충돌 동축제트의 벽면 온도 측정)

  • Gwak, Jong-Ho;Kumar, V. R. Sanal;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1631-1636
    • /
    • 2004
  • The supersonic impinging jet has been extensively applied to rocket launching system, gas jet cutting control, gas turbine blade cooling, etc. In such applications, wall temperature of an object on which supersonic jet impinges is a very important factor to determine the performance and life of the device. However, wall temperature data of supersonic impinging jets are not enough to data. The present study describes an experimental work to measure the wall temperatures of a vertical flat plate on which supersonic, dual, coaxial jet impinges. An Infrared camera is employed to measure the wall temperature distribution on the impinging plate. The pressure ratio of the jet is varied to obtain the supersonic jets in the range of over-expanded to moderately under-expanded conditions at the exit of coaxial nozzle. The distance between the coaxial nozzle and the flat plate was also varied. The coaxial jet flows are visualized using a Shadow optical method. The results show that the wall temperature distribution of the impinging plate is strongly dependent on the jet pressure ratio and the distance between the nozzle and plate.

  • PDF

Multi-gear Combination Analysis for High Gear Ratio of Coaxial Magnetic Gear (동축 마그네틱 기어의 고 기어비 적용을 위한 다중 기어 조합분석)

  • Park, Eui-Jong;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.2
    • /
    • pp.355-362
    • /
    • 2021
  • Since coaxial magnetic gears use non-contact power transmission, friction, wear, noise, and heat generated in the power transmission process of existing mechanical gears can be minimized. Currently, research for application to various industries is being actively conducted, but among the characteristics of coaxial magnetic gears, the problem of rapidly decreasing torque density at a high gear ratio was discussed. This paper proposes a direction for multiple gear combination using low gear ratio coaxial magnetic gears with high torque density. In order to confirm the effectiveness of the method, the torque density was compared with a single high gear ratio model, and the combination and design direction of multiple coaxial magnetic gears were shown.

The Experimental Study of Supersonic, Dual, Coaxial, Free, Jets (The effects of the assistant jet pressure ratio) (초음속 환형동축 자유 제트유동에 관한 실험적 연구 (보조제트 압력비 영향에 관하여))

  • 이권희;이준희;김희동
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.2
    • /
    • pp.51-58
    • /
    • 2001
  • Supersonic, axisymmetric, jets issuing from several kinds of dual, coaxial, nozzles were experimentally investigated. Four different kinds of coaxial, dual nozzles were employed to characterize the major. features of the supersonic, coaxial, dual jets. Two convergent-divergent supersonic nozzles with different impinging angle on the jet axis of were designed to have the Mach number 2.0 and used to compare the coaxial jet flows with those discharging from two sonic nozzles. The primary pressure ratio was changed in the range from 4.0 to 10.0 and the assistant jet ratio from 1.0 to 4.0. The results obtained show that the assistant jets from the annular. nozzle affect the coaxial jet flows and an increase of both the primary jet pressure ratio and assistant jet pressure ratio lead to a longer supersonic length of the dual, coaxial jet.

  • PDF