• Title/Summary/Keyword: Coating Tool

Search Result 198, Processing Time 0.022 seconds

Effect of Intermediate Layer Coated Diamond Particles on Performance of Diamond Tool (다이아몬드 입자에 형성된 중간층이 다이아몬드 공구 성능에 미치는 영향)

  • Son, Kyung-Sik;Lee, Jung-Hoon;Choi, Yong-Je;Jung, Uoo-Chang;Chung, Won-Sub
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.5
    • /
    • pp.216-222
    • /
    • 2013
  • In order to improve the performance of electrodeposited diamond-nickel composite, surface modification of diamond particles was carried out using powder immersion reaction assisted coating (PIRAC). Titanium and chromium were selected as coating elements, which are known as carbide former. With respect to the powder elements, various phases were formed on diamond; metallic Ti and TiC for Ti powder, $Cr_3C_2$ for Cr powder, and TiC and $Cr_3C_2$ for Ti-Cr mixed powder. Surface modified diamond particle showed higher specific surface area, especially Ti coating induced considerable increase of specific surface area. The increase of specific surface area suggests increase of surface roughness, and that was confirmed by surface observation using FE-SEM. In addition, wear properties of diamond-nickel composite including surface modified diamonds were improved, and Ti coated diamond showed the highest performance. The wear property of diamond-nickel composite is dependent on adhesion strength between diamond particle and nickel layer. Therefore, surface modification of diamond particle by PIRAC increasing surface roughness is effective to improve the properties of diamond-nickel composite.

Polydopamine Coating Behaviors on the Acrylic Acid Grafted-Nanofibers (아크릴산이 그라프트된 나노섬유에서의 폴리도파민 코팅)

  • Shin, Young Min;Kim, Woo-Jin;Park, Jong-Seok;Gwon, Hui-Jeong;Nho, Young-Chang;Lim, Youn-Mook
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.371-376
    • /
    • 2011
  • The surface property of the materials used in tissue engineering application has been essential to regulate cellular behaviors by directing their adhesion on the materials. To modulate surface property of the synthetic biodegradable materials, a variety of surface modification techniques have used to introduced surface functional groups or bioactive molecules, recently polydopamine coating method have been introduce as a facile modification method which can be coated on various materials such as polymers, metals, and ceramics regardless of their surface property. However, there are no reports about the degree of polydopamine coating on the materials with different hydrophilicity. In the present study, we prepared acrylic acid grafted nanofibrous meshes using electron-beam irradiation, and then coated meshes with polydopamine. Polydopamine successfully coated on the all meshes, both properties of acrylic acid and polydopamine were detected on the meshes. In addition, the degree of polydopamine deposition on the materials has been altered according to surface hydrophilicity, which was approximately 8-times greater than those on the non-modified materials. In conclusion, dual effect from the acrylic acid grafting and polydopamine may give a chance as a alternative tool in tissue engineering application.

Experimental and numerical research on ballistic performance of carbon steels and cold worked tool steels with and without Titanium Nitride (TiN) coating

  • Ergul, Erdi;Doruk, Emre;Pakdil, Murat
    • Steel and Composite Structures
    • /
    • v.23 no.2
    • /
    • pp.153-160
    • /
    • 2017
  • It is extremely important to be aware of the ballistic performances of engineering materials in order to be able to choose the lightest armor providing full ballistic protection in civil and military applications. Therefore, ballistic tests are an important part of armor design process. In this study, ballistic performance of plates made of carbon steel and cold worked tool steel against 7.62 mm AP (armor-piercing) bullets was examined experimentally and numerically in accordance with NIJ standards. Samples in different sizes were prepared to demonstrate the effect of target thickness on ballistic performance. Some of these samples were coated with titanium nitride using physical vapor deposition (PVD) method. After examining all successful and unsuccessful samples at macro and micro levels, factors affecting ballistic performance were determined. Explicit non-linear analyses were made using Ls-Dyna software in order to confirm physical ballistic test results. It was observed that the ballistic features of steel plates used in simulations comply with actual physical test results.

Corrosion Behavior of Hard Coated Ti-Zr-N Film on the Tool Steels

  • Eun, Sang-Won;Choe, Han-Cheol
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.289-293
    • /
    • 2010
  • To investigate the corrosion behavior of tools steel surface in various coating film, the surface of hard coated Ti-Zr-N film on the tool steel by using magnetron-sputtering methods was researched using various experimental methods. STD 61 steels were manufactured by using vacuum furnace and solutionized for 1hr at $1050^{\circ}C$. Steel surface was coated with Ti-Zr-N film at $150^{\circ}C$ and 100W for 1h by using DC-sputtering equipment. Surface characteristics of Ti-Zr-N film coated specimens were investigated by OM, XRD, FE-SEM and nano-scratch tester. And corrosion behaviors of the coated specimen were investigated by polarization test and electrochemical impedance spectroscopy(EG&G Co, PARSTAT 2273. USA). It was found that Ti-Zr-N film coated sample had a thick coated layer and showed a good wear resistance and corrosion resistance of surface compared with ZrN and TiN coated sample. The corrosion resistance and mechanical property of Ti-Zr-N film coated STD 61 alloy increased as sputtering time increased.

Biological Applications of Helium Ion Microscopy

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • v.43 no.1
    • /
    • pp.9-13
    • /
    • 2013
  • The helium ion microscope (HIM) has recently emerged as a novel tool for imaging and analysis. Based on a bright ion source and small probe, the HIM offers advantages over the conventional field emission scanning electron microscope. The key features of the HIM include (1) high resolution (ca. 0.25 nm), (2) great surface sensitivity, (3) great contrast, (4) large depth-of-field, (5) efficient charge control, (6) reduced specimen damage, and (7) nanomachining capability. Due to the charge neutralization by flood electron beam, there is no need for conductive metal coating for the observation of insulating biological specimens by HIM. There is growing evidence that the HIM has substantial potential for high-resolution imaging of uncoated insulating biological specimens at the nanoscale.

Performance Evaluation of Chip Breaker Utilizing Neural Network (신경망기법에 의한 칩브레이커의 성능평가)

  • Kim, Hong-Gyoo;Sim, Jae-Hyung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.64-74
    • /
    • 2007
  • The continuous chip in turning operation deteriorates precision of workpiece and causes a hazardous condition to operator. Thus the chip form control becomes a very important task for reliable machining process. So, grooved chip breaker is widely used to obtain reliable discontinuous chip. However, developing new cutting insert having chip breaker takes long time and needs lots of research expense due to a couple of processes such as forming, sintering, grinding and coating of product and many different evaluation tests. In this paper, performance of commercial chip breaker is evaluated with neural network which is learned with a back propagation algorithm. For the evaluation, several important elements(depth of cut, land, breadth, radius) which directly influence the chip formation were chosen among commercial chip breakers and were used as input values of neural network. With the results of these input values, the performance evaluation method was developed and applied that method to the commercial tools.

A study on the chemically vapor deposited TiC, TiN, and Ti(C, N) on $Si_3N_4$-TiC ceramic tools ($Si_3N_4$-TiC ceamic 공구에 화학증착된 TiC, TiN 및 Ti(C, N)에 관한 연구)

  • 김동원;김시범;이준근;천성순
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1988.06a
    • /
    • pp.39-42
    • /
    • 1988
  • 요업체 절삭공구(ceramic tool)는 공구강이나 초경제품에 비해 고속 절삭 작업이 가능하며 생산성을 높일 수 있기 때문에 최근 주목을 받고 있다. 본 실험에서 모재(substrate)로 사용된 $Si_3N_4$-TiC ceramic은 요업체 공구중에서 파괴인성이 우수하며, 주철이나 초합금을 절삭할 때 우수한 성능을 나타낸다. 그러나 요업체 절삭공구중에서 경도가 낮은 편에 속하며, Fe,Mn,O와 $Si_3N_4$가 화학적 반응을 일으켜서, steel을 절삭할 때 상면 마모(crater wear)가 심하게 발생하기 때문에 우수한 성능을 나타내지 못하고 있는 실정이다. 따라서 이러한 단점을 보완하기 위해 공구의 표면에 보호피막(protective coating)을 입히는 것은 필수적이다. 본 연구에서는 반응변수들이 TiC 및 TiN 증착층의 증착속도, 미세구조, 화학적 조성 및 증착층과 substrate 사이의 interface를 조사하여 각 증착층의 최적증착조건을 규명하고자 한다.

  • PDF

Oxidation Resistance and Preferred Orientation of TiAIN Thin Films (TiAIN 박막의 우선방위와 내산화성)

  • Park, Yong-Gwon;Park, Yong-Gwon;Wey, Myeong-Yong
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.676-681
    • /
    • 2002
  • Microstructure, mechanical properties, and oxidation resistance of TiAIN thin films deposited on quenched and tempered STD61 tool steel by arc ion plating were studied using XRD, XPS and micro-balance. The TiAIN film was grown with the (200) orientation. The grain size of TiAIN thin film decreased with increasing Al contents, while chemical binding energy increased with Al contents. When hard coating films were oxidized at $850^{\circ}C$ in air, oxidation resistance of both TiN and TiCN films became relatively lower since the surface of films formed non-protective film such as $TiO_2$. However, oxidation resistance of TiAIN film was excellent because its surface formed protective layer such as $_A12$$O_3$ and $_Al2$$Ti_{7}$$O_{15}$, which suppressed oxygen intrusion.

The NMRD Profiles of Ultrasmall Superparamagnetic Iron Oxide: Computer Simulation

  • 장용민;황문정;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.107-107
    • /
    • 2001
  • 목적: 초상자성 nano-particle 조영제의 자기이완효과에 관한 out sphere 기전에 기초하여 각각의 자기장의 세기에서 T1/T2 자기이완율을 나타내는 NMRD profile을 수치적으로 simulation 하는 프로그램을 개발하고자 하였다. 대상 및 방법: 초상자성 nano-particle 조영제의 경우 초상자성 물질을 생체적합성 고분자로 표면 coating하기 때문에 상자성 조영제와는 달리 전적으로 "out sphere"기여도만을 고려하였고 또한 초상자성 물질의 경우 자기적 에너지의 크기가 매우 크기 때문에 상자성 조영제의 기전에서 사용되는 "low field"근사를 사용할 수 없으므로 Brillouin 함수로 표현되는 총자화에 대한 표현을 적용하였다. nano-particle내에 포함된 Fe 원자수에 따른 T1 및 T2 NMRD Profile과 온도에 따른 T1 및 T2 NMRD Profile 그리고 초상자성 nano-particle size에 따른 T1 및 T2 NMR Profile을 PC (CPU=800 Mhz, memory=128 MB) 환경하에서 symbolic computation tool 인 MathCad (MathCad, USA)를 사용하여 구현하였다.

  • PDF

Tribological Characteristics of Soft/Hard Coating for High-Speed Rotating Machine Elements (고속회전 하는 정밀부품을 위한 연질/경질 코팅의 트라이볼로지적 특성에 관한 연구)

  • 오진규;정구현;김대은;유제환;김형채
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.393-397
    • /
    • 2003
  • Recently, rotating elements which use mechanical and electrical systems have been utilized for high speed and accuracy to increase the performance. The most important thing to get a more reliable system is to understand the friction, wear and characteristics which has an effect on various coated surfaces. In this study, the tribologicali characteristics of various soft/hard materials were investigated by using a custom-built pin-on-reciprocator tester From the experimental results, it was found that the friction coefficients of the soft material coated surfaces were lower under various normal loads due to trier self-lubricating ability and material transfer to the counter surface.

  • PDF