• 제목/요약/키워드: Coated material

검색결과 1,689건 처리시간 0.031초

타이타늄의 표면개질에 따른 도재 결합 특성 (THE BOND CHARACTERISTICS OF PORCELAIN FUSED BY TITANIUM SURFACE MODIFICATION)

  • 최택휴;박상원;방몽숙;양홍서;박하옥;임현필;오계정;김현승;이광민;이경구
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.169-181
    • /
    • 2007
  • Statement of problem: Titanium is well known as a proper metal for the dental restorations, because it has an excellent biocompatibility, resistance to corrosion, and mechanical property. However, adhesion between titanium and dental porcelains is related to the diffusion of oxygen to the reaction layers formed on cast-titanium surfaces during porcelain firing and those oxidized layers make the adhesion difficult to be formed. Many studies using mechanical, chemical and physical methods to enhance the titanium-ceramic adhesion have been actively performed. Purpose: This study meant to comparatively analyse the adhesion characteristics depending on different titanium surface coatings after coating the casts and wrought titanium surfaces with Au and TiN. Material and method: In this study, the titanium specimens (CP-Ti, Grade 2, Kobe still Co. Japan) were categorized into cast and wrought titanium. The wrought titanium was cast by using the MgO-based investment(Selevest CB, Selec). The cast and wrought titanium were treated with Au coating($ParaOne^{(R)}$., Gold Ion Sputter, Model PS-1200) and TiN coating(ATEC system, Korea) and the ultra low fusing dental porcelain was fused and fired onto the samples. Biaxial flection test was done on the fired samples and the porcelain was separated. The adhesion characteristics of porcelain and titanium after firing and the specimen surfaces before and after the porcelain fracture test were observed with SEM. The atomic percent of Si on all sample surfaces was comparatively analysed by EDS. In addition, the constituents of specimen surface layers after the porcelain fracture and the formed compound were evaluated by X-ray diffraction diagnosis. Result: The results of this study were obtained as follows : 1. The surface characteristics of cast and wrought titanium after surface treatment(Au, TiN, $Al_2O_3$ sandblasting) were similar and each cast and wrought titanium showed similar bonding characteristics. 2. Before and after the biaxial flection test, the highest atomic weight change of Si component was found in $Al_2O_3$ sandblasted wrought titanium(28.6at.% $\rightarrow$ 8.3at.%). On the other hand, the least change was seen in Au-Pd-In alloy(24.5at.% $\rightarrow$ 9.1at.%). 3. Much amount of Si components was uniformly distributed in Au and TiN coated titanium, but less amount of Si's was unevenly dispersed on Al2O3 sandblasting surfaces. 4. In X-ray diffraction diagnosis after porcelain debonding, we could see $Au_2Ti$ compound and TiN coating layers on Au and TiN coated surfaces and $TiO_2$, typical oxide of titanium, on all titanium surfaces. 5. Debonding of porcelain on cast and wrought titanium surface after the biaxial flection is considered as a result of adhesion deterioration between coating layers and titanium surfaces. We found that there are both adhesive failure and cohesive failure at the same time. Conclusion: These results showed that the titanium-ceramic adhesion could be improved by coating cast and wrought titanium surfaces with Au and TiN when making porcelain fused to metal crowns. In order to use porcelain fused to titanium clinically, it is considered that coating technique to enhance the bonding strength between coating kKlayers and titanium surfaces should be developed first.

체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 - (Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets -)

  • 이성호;선경;최재걸;손호성;정재승;안상수;오혜정;이환성;이혜원;김광택;정윤섭;김영하;김형묵
    • Journal of Chest Surgery
    • /
    • 제35권3호
    • /
    • pp.171-176
    • /
    • 2002
  • 배경: 혈액이 이물질과 접촉을 하면 체내에서 응고 및 염증기전을 활성화 시키게 되고 임상적으로 폐 및 신장 기능의 저하, 출혈 등을 유발할 수 있고 심한 경우 다발성 장기기능 저하까지 발생할 수 있다. 이 때문에 혈액-이물질 접촉표면을 개선하는 여러 가지 시도들이 이루어지고 있고 혈액접촉표면의 적합성을 평가하는 지표의 선택은 대단히 중요하다. 접촉면의 응고기전에서 혈소판의 침착이 가장 중요한 단계이고 혈소판의 침착을 확인하기 위하여 표면흡착 정도를 비교하는 방법이 흔히 사용되고 있는데, 대부분 in-vitro 혹은ex-vivo조건에서 시행되고 있으므로 생체 내 in-vivo상황을 정확히 대변한다고 보기 힘들다. 따라서 본 연구는 in-vivo 실험조건에서 동위원소(radioisotope)를 이용하여 혈소판의 표면흡착 정도를 정량 분석하는 방법의 유용성을 분석하고자 계획되었다. 대상 및 방법: 돼지(20-25 kg, n=6)를 이용하여 하행대동맥 우회회로를 구성하였다. 우회회로는 헤파린 표면처리가 안된 일반 PVC 도관(대조군; Capiox, Terumo, Japan)과 이온결합 헤파린 표면 처리된 PVC 도관(실험군; Duraflo ll, Baxter, USA)을 Y-connector로 연결하여 2개의 회로를 동시에 구성하였다. 수술 전날 동종의 실험동물로부터 혈액을 채취하여 원심분리를 통해 고농도 혈소판 용액(platelet concentrate)을 추출하였고, 수술 당일 동위원소(Tc-99m-HMPAO, 180 $\mu$Ci)을 섞어 30분간 방치한 다음, 10분간 원심분리하여 침전층의 labeling efficiency를 측정하였다. 분리된 침전층에 혈장을 섞어(5 ml) 실험동물에 정맥주사한 후, 전신 헤파린 처치 상태에서(1 mg/kg) 하행대동맥을 차단하여 우회도관 쪽으로 2시간 동안 혈액을 순환시키고 분리하였다. 각 도관의 내강을 생리식염수 500 ml로 동시에 세척한 다음, 일정 간격으로10$\times$10 mm 크기의 절편을 5개 채취하였다. 절편을 세분하여 측정튜브에 담아 동위원소 측정기(gamma counter, Cobra II , Packard ,USA)를 이용하여 Tc-99m-HMPAO의 분당 count수를 측정함으로써 혈소판의 흡착정도를 정량분석 비교하였다. 결과: 동위원소 측정기를 이용한 평균 count수는 각각의 실험군과 대조군의 비율을 이용하여 비교하였다. 평균 count수는 대조군에서 537.3 Ci/min였고 실험군에서는 311.1Ci/min로 측정되었으며, 두 군 사이의 비율은 대조군에 비하여 실험군이 1: 0.58로 통계적으로 유의하였다.(p=0.004) 결론: 위결과를 통하여 실험군이 대조군에 비하여 혈소판 표면흡착측면에서 우수하다는 것을 정량적으로 증명할 수 있었다. 저자 등이 사용한 in-vivo 동위원소 측정법으로 혈소판 흡착정도의 생체 내 실험으로 유용하며 의료용 고분자 재료의 혈액적합성 판정의 지표로 제시하고자 한다.

유통 주방기구의 재질별 용출 특성 평가 -금속제 주방기구 중심으로- (Evaluation of Elution Characteristics by Material for Kitchen Utensils - Focusing on the Metallic Kitchen Utensils)

  • 김재관;임경숙;김명길;박성희;서미영;이유나;김정선;구은정;채선영;박용배;윤미혜
    • 한국식품위생안전성학회지
    • /
    • 제36권1호
    • /
    • pp.51-59
    • /
    • 2021
  • 본 연구는 2019년 경기도내 대형매장과 중소형매장 및 재리시장에서 유통 중인 스테인리스, 알루미늄, 철 등 금속제 주방기구 82건을 대상으로 중금속 등 11종(납, 카드뮴, 비소 등)의 오염도를 조사하여 금속제 주방기구의 위생관리를 위한 기초자료로 활용하고자 하였다. 금속제 주방기구의 용출시험결과, 금속의 용출빈도는 철>알루미늄>크롬, 니켈>아연>구리>납>비소>안티몬>주석>카드뮴의 순으로 이었고 용출률은 7.3-93.9%이었다. 조사 대상 82건 중 알루미늄 주방기구 1건에서 니켈이 기준을 초과(결과 1.4 mg/L, 기준 0.1 mg/L 이하)한 것으로 나타났으며 그 밖에 기준이 설정되어 있지 않은 철에 코팅한 주방기구에서 니켈이 식품용 기구 및 용기·포장 공전 금속제 기준을 5배-193배 초과한 것으로 나타나 이에 대한 기준규격의 설정이 필요한 것으로 판단된다. 코팅하지 않은 금속제와 내부를 코팅한 주방기구 평균 용출량을 비교해보면, 알루미늄과 철은 코팅한 주방기구에서 낮게 나타났고 나머지 대부분의 중금속은 코팅한 주방기구에서 높은 수준으로 나타났다. 국산과 수입산으로 나누어 평균 용출량을 비교한 결과, 알루미늄과 철은 국산 및 수입산 모두 다른 중금속에 비해 높은 수준으로 나타났는데 알루미늄은 국산주방기구에서, 철은 수입산 주방기구에서 높게 나타났다. 주방기구의 코팅재질별로 평균 용출량을 비교한 결과, 불소수지 코팅에서는 알루미늄, 세라믹 코팅에서는 알루미늄, 철, 법랑코팅에서는 니켈, 알루미늄, 철, 구리, 기타(실리콘과 티타늄)코팅에서는 철의 용출량이 높게 나타났다.

건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선 (Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants)

  • 신우진;이철원;김만구
    • 분석과학
    • /
    • 제20권4호
    • /
    • pp.261-267
    • /
    • 2007
  • 건축자재에서 방출되는 오염물질을 평가하는 20 L 시험챔버법은 챔버 내부에 노출되는 시료의 표면방출만을 측정한다. 일정한 크기로 절단한 시편을 알루미늄 호일로 감싼 후 시편홀더에 고정시켜 20 L 시험챔버 내에 위치시킨 후 방출시험을 실시한다. 이때 시편홀더의 기밀성이 보장되지 못한다면 시료절단면에서 방출되는 오염물질로 인하여 정확한 평가가 이루어질 수 없다. 이러한 절단면의 영향은 표면처리를 하여 표면에서 보다 절단면에서 더 많은 오염물질이 방출되는 판상재(합판, 장판) 시료의 경우 더 크다. 이 연구에서는 바닥재로 사용되는 장판을 대상으로 20 L 시험챔버와 1 L 시험챔버의 방출시험결과를 비교하여 시편홀더의 기밀성을 확인하였다. 또한 가구재로 사용되는 LPM 양면처리한 MDF를 대상으로 현행의 시험방법과 시료절단면을 VOC 저방출 tape으로 밀봉한 방법을 비교하여 시편홀더의 부족한 기밀성의 개선이 가능하지 확인하였다. LPM 양면처리한 MDF의 7일 경과 후 방출강도는 TVOC의 경우 Tape 사용 유무에 따라 각각 $0.009mg/m^2h$, $0.003mg/m^2h$로 기밀성을 보완할 수 있었다. 또한 n=3에서 상대표준편차가 현행의 방법은 $0.004mg/m^2h$, tape을 사용했을 경우 $0.002mg/m^2h$로 현행 방법의 시험편홀더 기밀성 부족으로 인한 절단면의 불균일한 영향을 VOC 저방출테이프 사용으로 배제할 수 있었다.

Micromorphological and Chemical Characteristics of Cengal (Neobalanocarpus heimii) Heartwood Decayed by Soft Rot Fungi

  • Kim, Yoon Soo;Singh, Adya P.;Wong, Andrew H.H.;Eom, Tae-Jin;Lee, Kwang Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • 제34권2호
    • /
    • pp.68-77
    • /
    • 2006
  • The heartwood of cengal (Neobalanocarpus heimii) is known to have a high degree of decay resistance by virtue of its high extractive content. After 30 years in ground contact an utility pole of this tropical hardwood was found to be degraded only in the surface layers by cavity-forming soft rot fungi. The present work was undertaken 1) to characterize the degradation of cengal heartwood from the aspect of ultrastructure and chemistry and 2) to investigate the correlation between soft rot decay and its extractive microdistribution in wood tissues. The chemical analysis of cengal heartwood revealed the presence of a high amount of extractives as well as lignin. The wood contained a relatively high amount of condensed lignin and the guaiacyl units. Microscopic observations revealed that vessels, fibers and parenchyma cells (both ray and axial parenchyma) all contained extractives in their lumina, but in variable amounts. The lumina of fibers and most axial parenchyma were completely or almost completely filled with the extractives. TEM micrographs showed that cell walls were also impregnated with extractives and that pit membranes connecting parenchyma cells were well coated and impregnated with extractives. However, fungal hyphae were present in the extractive masses localized in cell lumina, and indications were that the extractives did not completely inhibit fungal growth. The extent of cell wall degradation varied with tissue types. The fibers appeared to be more susceptible to decay than vessels and parenchyma. Middle lamella was the only cell wall region which remained intact in all cell types which were severely degraded. The microscopic observations suggested a close correlation between extractive microdistribution and the pattern and extent of cell wall degradation. In addition to the toxicity to fungi, the physical constraint of the extractive material present in cengal heartwood cells is likely to have a profound effect on the growth and path of invasion of colonizing fungi, thus conferring protection to wood by restricting fungal entry into cell walls. The presence of relatively high amount of condensed lignin is also likely to be a factor in the resistance of cengal heartwood to soft rot decay.

페시베이션 박막이 녹색 유기발광다이오드의 광학특성에 미치는 영향 (Effects of Passivation Thin Films on the Optical Properties of the Green Organic Light Emitting Diodes)

  • 문세찬;이상희;박병민;피재호;장호정
    • 마이크로전자및패키징학회지
    • /
    • 제23권1호
    • /
    • pp.11-15
    • /
    • 2016
  • 유기발광다이오드(orgianic light emitting diodes, OLEDs)는 대형 유연 디스플레이와 발광원으로서 사물인터넷 (IoT)의 하드웨어 기기 등 다양한 분야에서 연구가 진행되고 있다. 그러나 낮은 일함수의 금속 및 쉽게 반응하는 유기재료 자체의 특성으로 인하여 외부환경에 매우 취약한 단점을 가지고 있으며 특히, 수분과 산소에 민감하여 외부와의 접촉 시 성능이 급속도로 저하되는 현상을 나타내게 된다. 이를 방지하기 위해 PVD, CVD, ALD 와 같은 방법으로 보호막 형성 연구를 진행 중에 있지만 복잡한 공정 및 높은 비용의 문제점 등이 있다. 그러므로 외부 환경에 의한 성능 저하를 차단해주는 저렴하고 단순한 공정의 페시베이션(passivation) 박막 기술 개발이 매우 중요하다. 본 연구에서는 유기발광다이오드의 수명 향상을 위하여 스핀코팅(spin-coating) 방법으로 녹색 유기발광다이오드 소자 위에 조성비에 따른 페시베이션 박막을 형성한 후 녹색 유기발광다이오드의 휘도특성 변화를 조사하였다. 페시베이션 용액은 poly vinyl alcohol (PVA)를 기반으로 sodium alginate (SA)를 0, 10, 20, 40 wt%의 조성비로 제조하였으며, 40 wt%의 조성비에서 가장 좋은 배리어 보호 특성을 나타내었다. 최종적으로 PVA + SA 용액의 최적화된 페시베이션 보호막을 제작할 수 있었다.

표면전하 거동 조절을 이용한 탈크-실리카 복합체의 제조 (Preparation of Talc-Silica Composites by Controlling Surface Charge Behavior)

  • 윤기훈;박민경;문영진;이동규
    • 한국응용과학기술학회지
    • /
    • 제34권1호
    • /
    • pp.116-124
    • /
    • 2017
  • 색조 화장품 원료로 사용되는 무기안료 탈크와 소수성 실리카의 제타전위 차를 조절하여 표면처리된 판상 무기안료 복합체를 제조하였다. 탈크는 색조 화장품의 처방에서 주로 쓰이는 판상 무기물질로서 피부에 대한 발림성과 퍼짐성을 갖는 백색 안료이다. 또한 분산성과 신장성이 우수하며, 내열성, 내광성, 내화학성 등에 안정하다. 실리카는 일반적인 색조화장품에서 화장의 지속성을 높여주며 제형에서의 안정성을 높여주는 역할을 한다. 본 연구에서는 탈크와 소수성 실리카를 각각 양이온성, 음이온성 계면활성제로 표면전하를 조절한 후 제타전위 차를 이용하여 탈크 표면에 소수성 실리카를 표면처리하여 무기안료 복합체를 제조하였다. 제조된 무기안료 복합체는 소수성 실리카가 탈크 표면 위에 $1{\mu}m$ 이하로 코팅되어 있으며 효과적인 소수성을 띤다. 무기안료의 표면전하 분석을 위해 제타전위를 측정하였고, 계면활성제 표면처리된 안료는 FT-IR 로 계면활성제의 작용기를 확인하였다. 무기안료 복합체의 표면은 SEM, EDS, FIB 등으로 관찰하였으며, XRD, FT-IR 등으로 구조를 확인하였다.

나노 납/활성탄을 사용한 ISG용 울트라 전지 음극소재의 전기화학적 특성 (Electrochemical Characteristics of Ultra Battery Anode Material using the Nano Pb/AC for ISG)

  • 황진웅;이종대
    • Korean Chemical Engineering Research
    • /
    • 제55권5호
    • /
    • pp.593-599
    • /
    • 2017
  • 본 연구에서는 활성탄과 납 전구체를 사용하여 나노 Pb/AC 복합소재를 제조한 후, 울트라 전지용 음극소재의 전기화학적 특성을 조사하였다. 나노 Pb/AC 복합소재는 활성탄에 나노 Pb 입자를 흡착시킨 후 감압 수세하여 제조하였다. 제조된 복합소재의 물리적 특성은 SEM, BET, EDS를 통해 분석하였으며, $1740m^2/g$, 1.95 nm의 비표면적과 평균 기공크기를 얻었다. 울트라 전지의 음극은 납 극판에 나노 Pb/AC를 딥코팅하여 제조되었다. 울트라 전지는 이산화납을 사용한 양극과 나노 Pb/AC 복합소재 음극을 사용하였으며 전해액은 5M의 황산용액($1.31g/cm^3$)을 사용하였다. 전기화학적 성능은 충 방전, 순환전압전류, 임피던스, 사이클 테스트를 통해 조사되었다. 제조된 나노 Pb/AC를 이용한 울트라 배터리는 기존의 납 축전지와 AC를 코팅한 납 축전지보다 개선된 초기 용량과 사이클 특성을 보였다. 이러한 실험 결과로부터 나노 Pb/AC의 적절한 첨가가 수소발생 반응이 억제됨에 따라 용량 및 장기 사이클 안정성을 향상시킴을 알 수 있었다.

임플란트-지대주-나사의 적합에 관한 연구 (A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE)

  • 김낙형;정재헌;손미경;백대화
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.

불가사리(Asterias amurensis) 추출물을 첨가한 사료의 급이가 조피볼락(Sebastes schlegeli)의 성장, 혈액성상 및 식세포 활성산소 생산에 미치는 효과 (Effects of Supplemental Asterias amurensis Extract in the Experimental Diets on Growth, Blood Chemistry and Superoxide Production of Kidney Phagocytes of Sebastes schlegeli)

  • 박희연;임치원;김연계;최태진;윤호동;이가정;서연경;김지영;박기의
    • Applied Biological Chemistry
    • /
    • 제50권4호
    • /
    • pp.362-366
    • /
    • 2007
  • 수산 해적생물인 불가사리의 주정추출물을 농도별로 사료에 첨가하여 조피볼락의 성장, 혈액성상 및 식세포 활성산소 생산에 미치는 효과를 조사하였다. 불가사리추출물의 함량이 다른 사료를 급여한 조피볼락의 1일성장율(SGR), 사료계수(FCR), 비만도(CF), 생존율(SR)을 비교한 결과, 실험군별 유의적인 차이를 보이지 않았다. 이는 불가사리추출물에 의한 먹이 기피현상을 방지하기 위해 사료를 코팅을 하였기 때문인 것으로 사료된다. 불가사리추출물이 조피볼락의 체내 대사계에 미치는 영향을 알아보기 위해 혈청 중의 glucose, total cholesterol의 함량과 GOT를 측정한 결과, glucose와 total cholesterol의 함량은 불가사리추출물의 함량이 증가할수록 높아지는 경향을 보였다. 한편, 혈청 GOT는 실험군별로 유의적인 차이를 보이지 않았으며 이는 불가사리추출물이 독성이 거의 없기 때문인 것으로 추정된다. 불가사리추출물 첨가사료의 급이가 조피볼락의 면역계에 미치는 영향을 알아보기 위하여 식세포의 활성산소 생산량을 측정한 결과, 불가사리추출물의 첨가에 따라 농도 의존적으로 증가하였다. 이상의 실험결과에서 불가사리추출물은 면역증강 기능성 사료첨가제로 활용할 수 있을 것으로 사료되었다.