• Title/Summary/Keyword: Coated Circuit

Search Result 122, Processing Time 0.031 seconds

Operating properties of superconducting fault current limiters with a sing1e line-to-ground fault in a three-phase system (3상 전력계통의 1선 지락사고에 대한 초전도한류기의 동작특성)

  • 최효상;현옥배;김혜림;황시돌;차상도
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.261-262
    • /
    • 2003
  • We performed unsymmetrical analysis of a single line-to-ground fault in a three-phase system. The current limiting elements were meander type YBCO stripes coated with Au shunt. When the fault occurred, short circuit currents were effectively limited within 1-2 msec after fault instant. The unsymmetrical rate of fault phase was distributed from 6.4 to 1.4 and most of the fault current flowed in the grounding line due to its direct grounding system.

  • PDF

Generated heat decrease of resistive superconducting fault current limiter using diodes (Diode를 이용한 저항형 초전도 한류기의 열발생 저감방안)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.925-927
    • /
    • 2000
  • We fabricated a resistive superconducting fault current limiter of meander type based on a YBCO film. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. When diodes were inserted in the parallel circuit to restrict the temperature increase in the SFCL element by reducing power supply cycles, the voltage could be increased to $\sqrt{2}$ times with the same quench resistance at a half and full cycles.

  • PDF

Influence of polymer coating on SFCL recovery under load

  • Gorbunova, D.A.;Kumarov, D.R.;Scherbakov, V.I.;Sim, Kideok;Hwang, Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.44-47
    • /
    • 2019
  • This paper is a study of recovery under load process of superconducting fault current limiter (SFCL). SFCL consists of five parallel-connected high-temperature superconductor (HTS) tapes additionally stabilized by stainless tape. Previously, HTS was heated by current pulse to simulate a short circuit in a power grid. During the cooling period, the current amplitude decreased to 23% or less of HTS critical current value, which is the simulation of network re-switching. When HTS with a polymer coating is cooled, temperature gradient on thermal insulation layer occurs, that prevents a boiling crisis and improves the heat sink into liquid nitrogen. Two samples are coated with a 30 ㎛ and 50 ㎛ polylactide (PLA) layers, reference sample has no polymer coating on it. Samples with a polymer coating show 3-5 times faster cooling than the reference one.

A Study on the Corrosion Properties of Underwater Wet Arc Welds using the SM 41 (선체용 압연 강판의 습식 수중 아크 용접부의 부식특성에 관한 연구)

  • Kwak, H.H.;Kim, C.G.;Kim, M.N.;Hwang, S.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.111-118
    • /
    • 2006
  • Underwater wet arc welds were experimentally performed on 11mm thick KR-RA steel plate using six different types of flux coated electrodes of 4.0mm diameter, KSKR, KSKT, USBL, JPUW, UWEA and UWEB. From analysis of bead appearance, detachability of weld slag, spatter occurrence and arc stability, JPUW gives the best result, and UWEB is superior to KSKR and KSKT. By experimental result of hardness distribution on the weld bonds, UWEB weld has the narrowest bond structure which is probable condition to get the best mechanical properties of weld. UWEB and JPUW welds have more even hardness distribution across weld deposit and base metal. Upon polarization test to measure the respondency of corrosion, the electrode of UWEB shows the most excellent degree due to the low open circuit potential difference.

  • PDF

Boundary and Flat Area Estimation of Circuit Elements in Conformal Coated PCB (Conformal Coating 된 PCB에서 회로 소자의 경계면과 평탄면 영역 추정)

  • Lee, Dong Hee;Kang, Myung Hwan;Cho, Sungryung;Jung, Kyeong Hoon;Kang, Dong Wook
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.06a
    • /
    • pp.8-10
    • /
    • 2018
  • 자동차에서 전장부품이 차지하는 비중이 증가하고 있다. 그런데 전장부품이 증가하면서 전자제어장치의 오작동으로 인한 사고 및 인명손실의 위험이 커졌다. 자동차 환경에서 발생하는 진동, 열기, 습기, 전자파를 차단하여 전장부품의 안정성을 확보와 위험을 최소화하기 위해 자동차 OEM에서는 Conformal Coating 기술을 적용하는 것이 일반적이다. Conformal Coating된 PCB 회로의 신뢰성을 높이기 위해서는 코팅 과정에서 발생하는 기포를 억제해야 한다. 그럼에도 불구하고 기포가 발생한 경우에는 해당 PCB를 폐기하는 것이 중요하다. 본 논문에서는 코팅된 PCB에서 발생한 기포를 자동으로 검사하기 위한 전처리 과정으로서 검사 소자의 경계면과 평탄면 영역을 추정/분할하는 영상처리 알고리즘을 제안한다. 코팅 기포의 특성이 소자의 경계면과 평탄면에서 매우 다르게 나타나므로 효율적인 기포 검출을 위해서 영역 분할은 필수적인 전처리 과정이다.

  • PDF

Comparison of Fault Current Limiting Characteristics between the separated Three-phase Flux-lock Type SFCL and the Integrated Three-phase Flux-lock Type SFCL (분리된 삼상 자속구속형 전류제한기와 일체화된 삼상 자속구속형 전류제한기의 전류제한 특성 비교)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.8
    • /
    • pp.689-693
    • /
    • 2009
  • We investigate the comparison of fault current characteristics between the separates three-phase flux-lock type superconducting fault current limiter(SFCL) and integrated three-phase flux-lock type superconducting fault current limiter(SFCL). The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core and superconducting elements are connected to secondary coil in series. Superconducting elements are used by the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. But the integrated three-phase flux-lock type SFCL consists of three-phase flux-reactors wound on an iron core. Flux-reactor consists of the same turn's ratio between coil 1 and coil 2 for each single phase. To compare the current limiting characteristics of the separated three-phase flux-lock type SFCL and integrated three-phase flux-lock type SFCL, the short circuit experiments are carried out fault condition such as the single line-to-ground fault. The experimental result shows that fault current limiting characteristic of the separated three-phase flux-lock type SFCL was better than integrated three-phase flux-lock type SFCL. And the integrated three-phase flux-lock type SFCL has an effect on sound phase.

Performance Characteristics of Polymer Photovoltaics using Dimethyl Sulphoxide incorporated PEDOT:PSS Buffer Layer

  • Park, Seong-Hui;Lee, Hye-Hyeon;Jo, Yeong-Ran;Hwang, Jong-Won;Gang, Yong-Su;Choe, Yeong-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.238-239
    • /
    • 2010
  • Dimethyl sulphoxide (DMSO) is one of the widely-used secondary dopants in order to enhance the conductivity of poly(3, 4-ethylenedioxy-thiophene):poly(styrene sulfonate) (PEDOT:PSS) film. In this work, we investigated the effect of DMSO doping in to PEDOT:PSS on the electrical performance of the bulk heterojunction photovoltaics consisting of poly(3-hexylthiophene-2, 5-diyl) and phenyl-C61-butyric acid methyl ester. Correlation between the power conversion efficiency and the mechanism of improving conductivity, surface morphology, and contact properties was examined. The PEDOT:PSS films, which contain different concentration of DMSO, have been prepared and annealed at different annealing temperatures. The mixture of DMSO and PEDOT:PSS was prepared with a ratio of 1%, 5%, 15%, 25%, 35%, 45%, 55% by volume of DMSO, respectively. The DMSO-contained PEDOT:PSS solutions were stirred for 1hr at $40^{\circ}C$, then spin-coated on the ultra-sonicated glass. The spin-coated films were baked for 10min at $65^{\circ}C$, $85^{\circ}C$, and $120^{\circ}C$ in air. In order to investigate the electrical performance, P3HT:PCBM blended film was deposited with thickness of 150nm on DMSO-doped PEDOT:PSS layer. After depositing 100nm of Al, the device was post-annealed for 30min at $120^{\circ}C$ in vacuum. The fabricated cells, in this study, have been characterized by using several techniques such as UV-Visible spectrum, 4-point probe, J-V characteristics, and atomic force microscopy (AFM). The power conversion efficiency (AM 1.5G conditions) was increased from 0.91% to 2.35% by tuning DMSO doping ratio and annealing temperature. It is believed that the improved power conversion efficiency of the photovoltaics is attributed to the increased conductivity, leading to increasing short-circuit current in DMSO-doped PEDOT:PSS layer.

  • PDF

Effects of Bonding Conditions on Joint Property between FPCB and RPCB using Thermo-Compression Bonding Method (열압착법을 이용한 경.연성 인쇄회로기판 접합부의 접합 강도에 미치는 접합 조건의 영향)

  • Lee, Jong-Gun;Ko, Min-Kwan;Lee, Jong-Bum;Noh, Bo-In;Yoon, Jeong-Won;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.63-67
    • /
    • 2011
  • We investigated effects of bonding conditions on the peel strength of rigid printed circuit board (RPCB)/ flexible printed circuit board (FPCB) joints bonded using a thermo-compression bond method, The electrodes on the FPCB were coated with Sn by a dipping process. We confirmed that the bonding temperature and bonding time strongly affected the bonding configuration and strength of the joints. Also, the peel strength is affected by dipping conditions; the optimum dipping condition was found to be temperature of $270^{\circ}C$ and time of 1s. The bonding strength linearly increased with increasing bonding temperature and time until $280^{\circ}C$ and 10s. The fracture energy calculated from the F-x (Forcedisplacement) curve during a peel test was the highest at bonding temperature of $280^{\circ}C$.

Development of Distribution Superconducting Fault Current Limiter and its Monitoring System for Power IT Application (배전급 초전도한류기 및 전력 IT 응용을 위한 실시간 모니터링 시스템 개발)

  • Park, Dong-Keun;Seok, Bok-Yeol;Ko, Tae-Kuk;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.398-402
    • /
    • 2008
  • Recently, the development of superconducting fault current limiters (SFCLs) has been required as power demands increase in the power system. A distribution-level prototype resistive SFCL using coated conductor (CC) has been developed by Hyundai Heavy Industries Co., Ltd. and Yonsei University for the first time in the world. The ratings of the SFCL are 13.2kV/630A at normal operating condition. A novel non-inductive winding method is used in fabricating coils so there is almost zero impedance during normal operation. The distribution SFCL is cooled by sub-cooled liquid nitrogen $(LN_2)$ of 65K and 3 bar to enhance cryo-dielectric performance, critical current density, and thermal conductivity. In order to make reliable operation of an SFCL in real power systems, we monitored and controled its operation conditions by using supervisory control and data acquisition (SCADA) method. Thus, a monitoring system for the SFCL employing information technology (IT) is proposed and developed to be on the lookout for the operation conditions such as inside temperature, inside pressure, $LN_2$ level, voltage and current. Since operation temperature should be kept constant, bang-bang control for temperature feedback with a heater attached to the cold head of cryo-cooler is applied to the system. Short-circuit tests with prospective fault current of 10kA and AC dielectric withstand voltage tests up to 143kV for 1 minute were successfully performed at Korea Electrotechnology Research Institute. This paper deals with the development of a distribution level SFCL and its monitoring system for reliable operation.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.