• Title/Summary/Keyword: Coagulation System

Search Result 272, Processing Time 0.034 seconds

Evaluation of Biological Aerated Filter Position on Water Treatment Processes for Water Quality Improvement (상수원수 전처리 시 효율향상을 위한 생물여과 반응기 위치선정)

  • Choi, Hyung-Joo;Choi, Dong-Ho;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.677-686
    • /
    • 2006
  • This study was the effectiveness of two downflow BAF(Biological Aerated Filter) systems at conventional water treatment system. A BAF reactor placed in front of coagulation and sedimentation tanks(Mode A) and after coagulation and sedimentation tanks(Mode B) that were compared in terms of removal of suspended particles, organic matters, and ammonia nitrogen. The suspended particles removal efficiency was over 80% for both Mode A and B, although Mode A gave slightly better results. $BOD_5$ removal and nitrification efficiencies were more than 90% for both reactor. The organic matter and ammonia removals were also superior in the Mode A. The biofilm thickness and biomass increased as increment of EBCT and the upper part of reactor more about 30% than lower part. The specific oxygen uptake rate(SOUR) was higher the upper part of reactor and Mode A than the lower part of reactor and Mode B. A cost analysis showed that the Mode A system was more cost effectiveness. It could save the coagulant dose by about 67% and the chlorine demand by about 95%. The ideal place to put the BAF reactor was in front of the coagulation/sedimentation process.

Application of Photocatalytic Degradation for Efficient Treatment of Organic Matter in Landfill Leachate in Jeju Island (제주도 매립장 침출수 중 유기물의 효율적 처리를 위한 광촉매 분해 반응의 응용)

  • Lee, Chang-Han;Lee, Taek-Kwan;Cho, Eun-Il;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.31 no.8
    • /
    • pp.677-689
    • /
    • 2022
  • In order to photocatalytically treat organic matter (CODCr) and chromaticity effectively, chemical coagulation and sedimentation processes were employed as a pretreatment of the leachate produced from landfill in Jeju Island. This was performed using FeCl3·6H2O as a coagulant. For the treated leachate, UV/TiO2 and UV/TiO2/H2O2 systems were investigated, using 4 types of UV lamps, including an ozone lamp (24 W), TiO2 as a photocatalyst, and/or H2O2 as an initiator or inhibitor for photocatalytic degradation. In the chemical coagulation and sedimentation process using FeCl3·6H2O, optimum removal was achieved with an initial pH of 6, and a coagulant dosage of 2.0 g/L, culminating in the removal of 40% CODCr and 81% chromaticity. For the UV/TiO2 system utilizing an ozone lamp and 3 g/L of TiO2, the optimum condition was obtained at pH 5. However, the treated CODCr and chromaticity did not meet the emission standards (CODCr: 400 mg/L, chromaticity: 200 degrees) in a clean area. However, for a UV/TiO2/H2O2 system using 1.54 g/L of H2O2 in addition to the above optimum UV/TiO2 system, the results were 395 mg/L and 160 degrees, respectively, which were within the emission standard limits. The effect of the UV lamp on the removal of CODCr, and chromaticity of the leachate decreased in the order of ozone (24 W) lamp > 254 nm (24 W) lamp > ozone (14 W) lamp > 254 nm (14 W) lamp. Only CODCr and chromaticity treated with the ozone (24 W) lamp met the emission standards.

Effect of spinning parameters of polyethersulfone based hollow fiber membranes on morphological and mechanical properties

  • Tewfik, Shadia R.;Sorour, Mohamed H.;Shaalan, Hayam F.;Hani, Heba A.
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.43-51
    • /
    • 2018
  • Hollow fiber (HF) membranes are gaining wide interest over flat membranes due to their compaction and high area to surface volume ratio. This work addresses the fabrication of HF from polysulfone (PS) and polyethersulfone (PES) using N-methylpyrrolidone (NMP) as solvent in addition to other additives to achieve desired characteristics. The semi-pilot spinning system includes jacketed vessel, four spinneret block, coagulation and washing baths in addition to dryer and winder. Different parameters affecting dry-wet spinning phase inversion process were investigated. Dope compositions of PES, NMP and polyvinyl pyrrolidone (PVP) of varying molecular weights as additive were addressed. Some critical parameters of importance were also investigated. Those include dope flow rate, air gap, coagulation & washing baths and drying temperatures. The measured dope viscosity was in the range from 1.7 to 36.5 Pa.s. Air gap distance was adjusted from 20 to 45 cm and coagulation bath temperature from 20 to $46^{\circ}C$. The HF membranes were characterized by scanning electron microscope (SEM), atomic force microscope (AFM) and mechanical properties. Results indicated prevalence of finger like structure and average surface roughness from about 29 to 78.3 nm. Profile of stress strain characteristics revealed suitability of the fibers for downstream interventions for fabrication of thin film composite membrane. Different empirical correlations were formulated which enable deeper understanding of the interaction of the above mentioned variables. Data of pure water permeability (PWP) confirmed that the fabricated samples fall within the microfiltration (MF)-ultrafiltration (UF) range of membrane separation.

Long-Term Expression of von Willebrand Factor by a VSV-G Pseudotyped Lentivirus Enhances the Functional Activity of Secreted B-Domain-deleted Coagulation Factor VIII

  • Park, Sang Won;Choi, Sang-Yun
    • Molecules and Cells
    • /
    • v.24 no.1
    • /
    • pp.125-131
    • /
    • 2007
  • von Willebrand factor (vWF) is a multimeric glycoprotein which functions within the coagulation system. It colocalizes with factor VIII (FVIII) by non-covalent interaction and alters its intracellular trafficking. vWF is also instrumental in maintaining the stability of secreted FVIII. The principal objective of this study was to generate a lentivirus-based vWF expression vector for gene therapy of hemophilia A. We inserted a vWF of 8.8 Kb into a lentiviral vector thereby producing VSV-G-pseudotyped vEx52. However, its titer was quite low, presumably because the length of vWF gene exceeds the size limit of the lentiviral vector. In order to overcome the low-titer, we concentrated the vEx52 and thus increased the efficiency of transduction approximately 6-fold with $1/100^{th}$ of the volume. However, as concentration requires an additional laborious step, we attempted to enhance the transduction efficiency by deleting exons 24-46 and 29-46 in pRex52 to construct pRex23 and pRex28, and in pvEx52, yielding pvEx23 and pvEx28, respectively. The transfected pRex52 had a profound effect on the activity of secreted FVIII, and this activity declined as domains of vWF were deleted. However, when the domain-deleted vWF-lentiviruses were transduced into K562 cells, the vEx28 increased the activity of the secreted FVIII compared to what was observed with vEx52. This result is probably due to higher efficiencies of transduction and expression while retaining the essential domains required for proper interaction with FVIII.

Clinical Outcomes of Percutaneous Plasma Disc Coagulation Therapy for Lumbar Herniated Disc Diseases

  • Kim, Sang-Hyun;Kim, Sung-Chul;Cho, Ki-Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • Objective : This is prospective study of clinical outcomes of percutaneous plasma disc coagulation Therapy (PDCT) in patients with herniated lumbar disc disease (HLD) to evaluate the safety and efficacy in its clinical application and usefulness as a reliable alternative to microscopic discectomy. Methods : Forty-six patients were enrolled in this study from April 2006 to June 2010. All patients had one-level HLD. Disc degeneration was graded on routine T2-weighted magnetic resonance Image (MRI) using the Pfirrmann's grading system and all index levels were grade 3 and grade 4. Indications for surgery were radiculopathy caused by disc protrusion with soft consistency. MRI was done at one month after the procedure in all patients to check post-PDCT change. The clinical outcomes were evaluated using Visual Analog Scales (VAS) score and MacNab's criteria. Results : This study was approved by the Institutional Review Board of our institution. The age of the study population ranged from 16 to 59 years with a mean age of 37.2 years. There were 29 males and 17 females in this study. The mean period of clinical follow-up was 21 months. The average preoperative VAS score for radiculopathy was $7.4{\pm}1.4$, while the final follow-up VAS score was $1.4{\pm}0.7$ (p<0.001). In MacNab's criteria, 41 patients (89.1%) had achieved favorable improvement (excellent and good) until later follow-up. There were one patient from infection and two patients who needed to convert to open discectomy. Conclusion : PDCT is a safe and efficient treatment modality in a selective patient with HLD.

Inhibition Activities of Sea Weeds on Prolyl Endopeptidase, Tyrosinase and Coagulation (해조류 메탄올 추출물의 Prolyl Endopeptidase, Tyrosinase 저해 및 항응고 활성 스크리닝)

  • Lee, Hyun-Jin;Kim, Jin-Hui;Lee, Chu-Hyun;Kim, Jong-Sik;Kwak, Sang-Tae;Lee, Kyung-Bok;Song, Kyung-Sik;Choi, Byung-Wook;Lee, Bong-Ho
    • Korean Journal of Pharmacognosy
    • /
    • v.30 no.3
    • /
    • pp.231-237
    • /
    • 1999
  • About forty sea weeds were screened for their inhibitory effects against prolyl endopeptidase, tyrosinase and thrombus coagulation. Out of them, methanolic extract of Ecklonia cava, Sargassum patens, Sargassum hemiphyllum, Sargassum thunbergii, Sargassum singgildianum, Hizikia fusiformis, and Ishige okamurae inhibited more than 90% of prolyl endopeptidase activity at 40 ppm. Sargassum siliquastrum and Ecklonia cava exhibited 51% and 76% of inhibitory activity against tyrosinase at 40 ppm, respectively. In APTT assay system, Sargassum singgildianum, Pterocladia capilacea and Hizikia fusiformis delayed coagulation of thrombus about two times (210, 211, and 198% over control at ca 367 ppm, respectively) and in TT assay, Lomentaria catenata, Laurencia okamurae, and Hizikia fusiformis did most effectively (216,197, and 251% at ca 367 ppm, respectively).

  • PDF

Hemophilia B (factor IX deficiency) in a Labrador retriever dog

  • Kim, Jun-Hwan;Noh, Dong-Ho;Song, Ru-Hui;Lee, Da-Mi;Cho, Ho-Seong;Yu, Do-Hyeon;Park, Jin-Ho;Park, Chul
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.2
    • /
    • pp.191-193
    • /
    • 2011
  • A 3-month-old intact male, Labrador retriever was presented with the history of coagulopathy and anemia. The results of initial screening tests of the hemostatic system yielded a tentative diagnosis of hemophilia. Activated partial thromboplastin time (APTT) was distinctly prolonged (106 seconds) and prothrombin time (PT) was not detected due to markedly prolonged test time. Whole blood transfusions (20 me l/kg body weight) were carried out prior to assays of coagulation factor. After transfusion, the patient recovered well and hemorrhage ceased. Blood samples were assessed for coagulation factor activity. The patient showed markedly low factor IX coagulation activity (5%, reference range: 7~140%) and was diagnosed with hemophilia B. After recovery, the patient was discharged from the hospital. However, 4 months later the patient was re-hospitalized for recurrence of the initial symptoms. The owner did not want to pursue further treatment and the patient died of respiratory distress two days later.

Effect of Nano-sized Carbon Black Particles on Lung and Circulatory System by Inhalation Exposure in Rats

  • Kim, Jong-Kyu;Kang, Min-Gu;Cho, Hae-Won;Han, Jeong-Hee;Chung, Yong-Hyun;Rim, Kyung-Taek;Yang, Jeong-Sun;Kim, Hwa;Lee, Moo-Yeol
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.282-289
    • /
    • 2011
  • Objectives: We sought to establish a novel method to generate nano-sized carbon black particles (nano-CBPs) with an average size smaller than 100 nm for examining the inhalation exposure risks of experimental rats. We also tested the effect of nano-CBPs on the pulmonary and circulatory systems. Methods: We used chemical vapor deposition (CVD) without the addition of any additives to generate nano-CBPs with a particle size (electrical mobility diameter) of less than 100nm to examine the effects of inhalation exposure. Nano-CBPs were applied to a nose-only inhalation chamber system for studying the inhalation toxicity in rats. The effect on the lungs and circulatory system was determined according to the degree of inflammation as quantified by bronchoalveolar lavage fluid (BALF). The functional alteration of the hemostatic and vasomotor activities was measured by plasma coagulation, platelet activity, contraction and relaxation of blood vessels. Results: Nano-CBPs were generated in the range of 83.3-87.9 nm. Rats were exposed for 4 hour/day, 5 days/week for 4 weeks to $4.2{\times}10^6$, $6.2{\times}10^5$, and $1.3{\times}10^5$ particles/$cm^3$. Exposure of nano-CBPs by inhalation resulted in minimal pulmonary inflammation and did not appear to damage the lung tissue. In addition, there was no significant effect on blood functions, such as plasma coagulation and platelet aggregation, or on vasomotor function. Conclusion: We successfully generated nano-CBPs in the range of 83.3-87.9 nm at a maximum concentration of $4.2{\times}10^6$ particles/$cm^3$ in a nose-only inhalation chamber system. This reliable method can be useful to investigate the biological and toxicological effects of inhalation exposure to nano-CBPs on experimental rats.

Effect of cake resistance by first-aggregation of in-line injection system (인라인 주입방식의 최초응집이 케이크 저항에 미치는 영향)

  • KIM, Taeyoung;PARK, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.281-288
    • /
    • 2008
  • Cake resistance is influenced by floc size deposited on membrane surface. Enlarging floc size can reduce cake resistance. The small particles are enlarged by coagulation and flocculation process in conventional mixing tank at membrane filtration system. Fully-grown flocs for reducing the cake resistance, however, are ruptured while passing through a pump. In light of this fact, this study aims to experimentally look at the reaggregation phenomenon of mixing system. In addition, reaggregation phenomenon of mixing system is compared with first-aggregation of in-line injection system in which coagulant is injected just before a pump. These results suggest that first-aggregation of in-line injection system is better than reaggregation of mixing system for G-value above $3100sec^{-1}$. Since G-value in pipe of actual membrane filtration system are usually larger than $3100sec^{-1}$. The performance of in-line injection system is expected to be better than the conventional mixing tank system.

Characteristics of Adsorption on the RO Membrane Surface by Coagulants Types (응집제 종류에 따른 RO막 표면 흡착 특성)

  • Jeong, Youngmi;Park, Chanhyuk;Lee, Sanghyup;Kweon, Jihyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.477-483
    • /
    • 2007
  • A coagulation process for RO (reverse osmosis) membrane pretreatment system was an effective technology to remove colloidal and particulate matters. However, coagulant residuals from the pretreatment process may negatively affect RO membrane performance. The bench-scale coagulant exposure study was performed to investigate the effect of their residual on adsorbed mass which related to the membrane performance. Coagulant addition in this study ranged from 0 to 5mg/L ferric chloride, alum, and 2mg/L cationic polymer(poly-di-methyldiallyl ammonium chloride) as coagulant aids. This results showed that adsorbed mass is not significantly increased during short-time period, however, accumulated mass of coagulants on the membrane surface is significantly increased during long-time experimental period. The effect of pH on coagulants adsorption characteristics was significantly differed due to the electrostatic repulsive interactions between soluble coagulants and membrane surface charge. This data suggest that the RO membrane performance of drinking water treatment plant could be decreased by adsorption of residual coagulants when applied for the coagulant pretreatment process.