• 제목/요약/키워드: Coagulation System

검색결과 271건 처리시간 0.024초

Metabolomics comparison of rumen fluid and milk in dairy cattle using proton nuclear magnetic resonance spectroscopy

  • Eom, Jun Sik;Kim, Eun Tae;Kim, Hyun Sang;Choi, You Young;Lee, Shin Ja;Lee, Sang Suk;Kim, Seon Ho;Lee, Sung Sill
    • Animal Bioscience
    • /
    • 제34권2호
    • /
    • pp.213-222
    • /
    • 2021
  • Objective: The metabolites that constitute the rumen fluid and milk in dairy cattle were analyzed using proton nuclear magnetic resonance (1H-NMR) spectroscopy and compared with the results obtain for other dairy cattle herds worldwide. The aim was to provide basic dataset for facilitating research on metabolites in rumen fluid and milk. Methods: Six dairy cattle were used in this study. Rumen fluid was collected using a stomach tube, and milk was collected using a pipeline milking system. The metabolites were determined by 1H-NMR spectroscopy, and the obtained data were statistically analyzed by principal component analysis, partial least squares discriminant analysis, variable importance in projection scores, and metabolic pathway data using Metaboanalyst 4.0. Results: The total numbers of metabolites in rumen fluid and milk were measured to be 186 and 184, and quantified as 72 and 109, respectively. Organic acid and carbohydrate metabolites exhibited the highest concentrations in rumen fluid and milk, respectively. Some metabolites that have been associated with metabolic diseases (acidosis and ketosis) in cows were identified in rumen fluid, and metabolites associated with ketosis, somatic cell production, and coagulation properties were identified in milk. Conclusion: The metabolites measured in rumen fluid and milk could potentially be used to detect metabolic diseases and evaluate milk quality. The results could also be useful for metabolomic research on the biofluids of ruminants in Korea, while facilitating their metabolic research.

일체형 완속교반/침전 그물망 압착식 섬유여과장치를 이용한 하수처리장 반류수 내 고농도 인 및 부유물질 처리 (Treatment of Phosphorus and Suspended Solid in Reject Water of Sewage Using an Integrated Slow Mixing/Sedimentation and Net Fit Fiber Filtration System)

  • 김정숙;김민호;김미란;장정국
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.816-821
    • /
    • 2017
  • 하수 및 폐수 내 고농도의 인 및 부유물질 제어를 위해 개발한 일체형 완속교반/침전 그물망 압착식 섬유여과시스템을 이용하여 하수처리장의 반류수 내 부유성 고형물 및 인 처리에 적용했을 경우에 따른 성능을 검토하고자 하였다. 6가지 Mode로 실험을 하였으며, 16.7, 33.3, 41.7 및 50.0 ton/day 유량과 Al/P 몰비 2~4의 조건에서 실험을 행하였다. 응집제를 주입하였을 경우에 모두 높은 총인(T-P) 제거 효율을 보였지만 연속운전시간이 7.8 min~11.4 min으로 짧아지는 단점이 생겼다. 이를 극복하기 위해 일체형 완속교반/침전 그물망 압착식 섬유여과시스템을 응집/급속교반/공기주입/완속교반/침전공정 및 여과공정으로 진행 시 연속운전시간이 88.2 min으로 다른 모드로 운전한 결과에 비해 8~11.3배 정도 증가하였다. 역세수량율도 5.4%로 매우 낮게 나타남에 따라 이 공정이 가장 효율적인 처리방안으로 평가되었다.

아급성흡입독성시험을 이용한 3-Methylpentane의 GHS 분류·표시 (A Study on GHS Classification of 3-Methylpentane by Subacute Inhalation Toxicity)

  • 정용현;한정희;신서호
    • 한국가스학회지
    • /
    • 제21권1호
    • /
    • pp.6-17
    • /
    • 2017
  • 본 연구는 3-methylpentane에 대한 흡입유해성을 평가하여 국제연합에서 정하는 화학물질의 분류 및 표지에 관한 세계조화시스템(Globally harmonized system, GHS)지침 및 고용노동부고시 제2013-37호에 따른 3-methylpentane의 화학물질 분류 표시 자료를 생산하기 위하여 OECD 화학물질 시험가이드라인 아급성흡입독성시험 TG 412(Subacute inhalation toxicity) 시험법에 따라 수행하였다. 본 연구를 위하여 6주령의 랫드(Rat)를 도입하여 1주간 순화시킨 후 암수 각각 대조군 5마리, 저농도군(284 ppm) 5마리, 중농도군(1,135 ppm) 5마리, 고농도군(4,540 ppm) 5마리 등으로 군을 구성하여 일일 6시간, 주 5일, 4주 동안 시험물질을 랫드에 전신으로 노출시켰다. 시험물질 노출을 종료하고 2주 후 시험동물을 희생하여 시험물질에 의한 시험동물의 영향을 평가하였다. 사료섭취량 변화, 체중 변화, 임상관찰, 혈액검사, 부검 소견, 장기무게 측정, 조직병리검사 등 모든 시험결과에서 시험물질에 의한 영향은 나타나지 않아 3-methylpentane의 무유해영향농도는 암수 모두 4,540 ppm이상으로 판단되어 세계조화시스템(GHS) 지침 및 고용노동부고시 제2013-37호(화학물질의 분류 표시 및 물질안전보건에 관한 기준)의 특정표적장기독성(반복노출) 구분 표시 물질에 해당하지 않은 물질로 판단되었다.

실 규모 물 처리 공정 및 후속 흡착 처리에 의한 오염원 제거 잠재성 평가 (Potential of Contaminant Removal Using a Full-Scale Municipal Water Treatment System with Adsorption as Post-Treatment)

  • 변해일;여건희;응우옌 홍안;김영웅;김동건;이태훈;정설화;최영화;오승대
    • 토지주택연구
    • /
    • 제15권1호
    • /
    • pp.167-177
    • /
    • 2024
  • 본 연구에서는 하이드로사이클론, 응결/응집, 용존공기부상 단일 공정이 결합한 실 규모 물순환 조합공정(HCFD)의 오염 지표수 처리 성능을 평가하였다. 실 규모 물순환 공정은 수질 변동이 큰 유입 원수를 대상으로 안정적인 수처리 효율을 보였으며, 유입수의 주요 수질 지표가 매우 나쁨(BOD, TP, COD) 혹은 약간 나쁨(SS)이었으나, 방류수는 매우 좋음(BOD, SS, TP) 혹은 좋음(COD) 수준으로 향상되었다. 물순환 시스템 방류수의 후속 고도 처리를 위해 활성탄 기반 흡착 공정의 용존성 유기물 및 미량오염물질(잔류의약물질 APAP 및 산업 화학물질 AO7) 처리 잠재성을 평가하였다. 오염원 흡착 특성은 흡착동역학 및 등온 흡착실험과 관련된 모델링 기법을 이용하여 관찰하였다. 실험 결과, 후처리 활성탄 흡착은 잔류 유기물, APAP, AO7 유기물에 대한 높은 오염원 제거 잠재성이 있음이 확인되었으며, 오염원 흡착속도 및 최대 흡착량 값은 유사 2차 반응속도 모델과 Langmuir 등온흡착 모델에 의해 결정되었다. 본 연구 결과, 활성탄 기반 흡착 공정은 기존의 물순환 조합공정과 연계시 수처리 효율을 상호 보완적으로 높이고, 흡착 공정은 전단의 입자 분리 공정으로 제거가 어려운 용존성 오염원의 후속 처리에 대한 높은 잠재성이 있음을 시사한다.

공장폐열(工場廢熱) 회수장치(回收裝置)에 관한 연구(硏究) -U자형(字型) 다관식(多管式) 열교환기(熱交換機)의 성능(性能)에 관하여- (Study on the Exhaust Heat Recovery Equipment in a Factory - On the Performance of a U-shape Multitube Heat Exchanger -)

  • 김영복;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제8권2호
    • /
    • pp.49-61
    • /
    • 1983
  • U shape multitube heat exchanger was equipped in the flue to recover the exhaust heat from the boiler system. The fluids of the exhaust heat recovery equipment were the flue gas as the hot fluid, and the water as the cold fluid. The flow geometry of the fluids was cross flow - two pass, the hot fluid being mixed and the cold fluid unmixed. The results of the theoretical and the experimental analysis and the economic evaluation are summarized as follows. 1) The heat exchanger effectiveness and the temperature efficiency of the hot fluid were about 35% when the fuel consumption rate was 140 - 150 L/15min. The temperature efficiency for the cold fluid ranged from 3.0% to 4.5%. The insulation efficiency ranged from 85% to 98%, which was better than the KS air preheater insulation efficiency of 90%. 2) The relationship between the fuel consumption rate, F, and the outlet temperature, $T_{h2}$, of the flue gas from the heat exchanger was $T_{h2}$ = 0.927F + 110. In order to prevent the low temperature corrosion from the coagulation of $SO_3$, it is necessary to maintain the fuel consumption rate above 82 L/15min. 3) The ratio of the exhaust heat from the boiler system to the total energy consumption was about 14.5%. With the installation of the exhaust heat recovery equipment, the energy recovery ratio to the exhaust heat was about 25%. Accordingly, about 3.6% of the total fuel consumption was estimated to be saved. 4) Economic analysis indicated that the installation of the exhaust heat recovery equipment was feasible to save the energy, because the capital reocvery period was only 10 months when the fuel consumption rate was 80 L/15min. 4 months when it was 160 L/15min. 5) Based on the theoretical and the experimental analysis, it was estimated to save the energy of about 18 million Won per year, if four heat exchangers are installed in a factory. 6) A further study is recommended to identify the relationship among the flow rate of the exhaust gas, the size of the heat exchanger and the capacity of the air preheater. For a maximum heat recovery from the exhaust gas an automatic control system is required to control the flow rate of the cold fluid depending on the boiler load.

  • PDF

역삼투막 전처리로서의 2단 섬유상 여과기를 이용한 정수처리 연구 (Potable Water Treatment Study using the Double Stage Fiber Filter for the Pre-treatment of the Reverse Osmosis Membrane)

  • 배시열;장형욱;윤창한
    • 멤브레인
    • /
    • 제20권2호
    • /
    • pp.97-105
    • /
    • 2010
  • 2009년 1월 3일부터 12월 1일까지 11개월간 공업용수를 주변지역에 공급하는 A정수장 응집침전조의 상등수를 대상으로 실험을 진행한 본 연구는 RO막 전처리 장치로서의 압력식 섬유여과기인 PCF 여과기 2대를 직렬연결한 공정의 적용 가능성을 평가한 것이다. 성능평가는 SDI (Silt Density Index)를 통해 간접적으로 RO막에 대한 전처리 성능을 평가하였다. 실험 기간 동안 PCF Filter로 유입된 원수의 탁도는 평균 0.79 (0.28~4.01) NTU이었으며, 처리수의 탁도는 평균 0.16(0.04~0.50) NTU로 탁도 제거효율은 평균 77%이었다. 일일 평균 처리유량은 약 230 $m^3$/day고 평균 역세유량은 8.7 $m^3$/day로 평균 역세수량은 3.8%로 나타났다. 여과수의 탁도 및 SDI 값은 측정 전 보관시간에 따라 증가하는데 이번 실험에서 몇몇 시료는 1~11일 동안 보관한 후 탁도 및 SDI가 측정되었으며, 이들 전체의 평균 SDI 값은 3.6 (2.26~5.00)으로 RO 제조업체에서 RO의 수명보증을 위해 통상 요구하는 SDI 값인 5.0 이하를 나타내었다. 따라서 RO 전처리공정의 SDI 측면에서 2단 섬유여과 공정이 적합함을 알 수 있었다.

HMUS와 SBR 반응조를 이용한 축분처리에 관한 연구 (Pig slurry treatment by the pilot scale hybrid multi-stage unit system (HMUS) followed by sequencing batch reactor (SBR))

  • 이영신;한기봉
    • 유기물자원화
    • /
    • 제21권2호
    • /
    • pp.63-70
    • /
    • 2013
  • 현장 실규모의 다단공정으로 ATAD, EGSB 및 SBR을 조합한 HMUS 공정을 이용하여 돼지 축분 처리가능성을 시험하였다. 실험결과 고농도 유기물, 질소와 인의 제거에 효과적이었다. 각 오염항목의 시스템 공정별 처리효율이 ATAD 공정에서는 CODcr이 43.3%로 제일 높게 나타났다. 다음 단계인 응집침전 공정에서는 TS의 제거효율이 96.5%로 가장 높게 나타났다. 운전조건 중 OLR은 3-6Kg $COD/m^3{\cdot}day$ 및 선속도는 1.5-4 m/h의 범위일 때 평균 CODcr 제거 효율은 HRT 3일에서 가장 높게 나타났다. 유입수의 성상이 영향을 미치는 고온호기성 산화반응은 TS가 50,000 mg/L 이상 되어야 고온발열효과를 얻어 병원균을 사멸할 수 있는 온도를 얻었다. EGSB 공정을 거치는 동안 유기물제거량 당 발생된 가스발생량은 $2.3{\sim}8.5m^3/kgTS{\cdot}d$ (평균 $5.2m^3/kgTS{\cdot}d$)로 나타났다. 후처리단계인 간헐포기공정에서 전체운전기간 중 평균제거효율은 CODcr 71.7%, TS 64.1%, TN 45.9%, 및 TP 50.4% 로 나타났다.

펜톤산화 공정에서 발생하는 슬러지의 재활용 방안 (Methodology Development for the Reuse of Sludge Generated from Fenton's Oxidation Process)

  • 구태완;조순행;최영수
    • 대한환경공학회지
    • /
    • 제22권6호
    • /
    • pp.1083-1091
    • /
    • 2000
  • 본 연구는 펜톤산화 공정에서 발생되는 펜톤슬러지를 응집제와 펜톤산화 공정에서의 촉매로 재이용할 수 있는지 여부를 검토하여 고농도의 난분해성 유기물질을 함유한 침출수를 효과적이고 경제적으로 처리할 수 있는 기술을 개발하는데 그 목적을 두었다. Batch-Scale 연구 결과 펜톤슬러지를 응집제와 펜톤산화 공정의 촉매제로 혼합사용하여 응집 공정과 펜톤산화 공정에 적용할 경우 약품만을 사용하는 경우보다 응집제의 사용량을 50%, 펜톤산화 공정의 촉매제 사용량을 50% 감소시킬 수 있었으며, 응집 공정과 펜톤산화 공정에서 발생되는 슬러지의 발생량도 감소시킬 수 있는 것으로 조사되었다. 실험실 규모의 연속식 처리 실험을 수행한 결과 펜톤슬러지를 응집제로 재이용함으로써 평균 8.5% 정도 유기물 제거효율이 증가하였으며, 슬러지의 발생량은 35% 감소하는 것으로 조사되었다. 또한 펜톤슬러지를 펜통촉매제로 재이용함으로써 유기물 제거면에서 평균 5.3% 정도 효율이 증가하였으며, 슬러지의 발생량은 14% 정도 감소하는 것으로 조사되었다. 이상의 결과로 펜톤산화 공정에서 발생하는 슬러지의 재이용은 약품 비용이나 슬러지 처리 비용을 절감시킬수 있을 것으로 결론지을 수 있다.

  • PDF

총인 수질기준강화를 위한 국내 하수종말처리장의 물리화학적처리 특성조사 및 경제성 분석 (Survey of Physicochemical Methods and Economic Analysis of Domestic Wastewater Treatment Plant for Advanced Treatment of Phosphorus Removal)

  • 박혜영;박상민;이기철;권오상;유순주;김신조
    • 대한환경공학회지
    • /
    • 제33권3호
    • /
    • pp.212-221
    • /
    • 2011
  • 우리나라의 공공하수처리시설은 생물학적 인 제거공정을 운전하고 있으나, '12년부터 지역구분(I, II, III)에 따라 각각 0.2, 0.3 및 0.5 mg/L로 강화되는 방류수수질기준을 준수하기 위해서는 화학물질을 이용한 추가적인 인 처리시설을 적용할 필요성이 대두되었다. 강화된 총인의 수질기준을 만족하기 위해 적용된 물리화학적 처리기술 성능의 구체적인 운영자료 구축을 위하여, 화학적 응집제 사용 중인 인 처리시설 중 모범적으로 가동하고 있는 국내 시설의 운영 데이터를 분석하여 처리성능을 평가하였다. 또한, jar 테스트를 이용해 물리화학적 인 제거공정 적용 시 최적 응집제 주입율 도출, 인 제거 및 슬러지 발생특성을 관찰하고 약품비용과 슬러지 발생증가량을 산정하여 실처리장에 응집제 적용 시 예상되는 경제성 분석을 하였다. 활성슬러지를 이용한 jar 테스트 결과, 0.5와 0.2 mg/L 이하의 총인 농도를 달성하기 위해 필요한 최소한의 응집제(황산알루미늄, 폴리염화알루미늄)의 주입농도는 각각 25와 30 mg/L (as $Al_2O_3$)이며, 2차 처리수의 경우에는 동일한 총인 농도를 달성하기 위해 요구되는 응집제 주입농도가 활성슬러지에 비해 약 1/12~1/3 수준으로 감소하였다. jar 테스트 결과, 활성슬러지에 응집제를 주입할 경우에 고형물 농도가 약 10~11%가 증가할 것으로 예측되었다. 한편, 활성슬러지에 응집제를 주입하는 경우의 응집제(황산알루미늄) 구입비는 2차 처리수에 주입하는 경우에 비해 약 4~10배 정도가 증가할 것으로 산정되었다. 또한, 슬러지 발생량은 약 4~10배 정도 증가할 것으로 예측되었다.

수용액 중의 염료 제거를 위한 폐수처리공정의 특성(1) -화학적 응집 및 생물학적 처리- (Characteristics of The Wastewater Treatment Processes for The Removal of Dyes in Aqueous Solution(1) - Chemical Precipitation or Biological Treatment -)

  • 한명호;허만우
    • 한국염색가공학회지
    • /
    • 제17권2호
    • /
    • pp.31-39
    • /
    • 2005
  • This study was conducted to remove the dyes in dye wastewater by the chemical precipitation or biological treatment which are one of the main pollutants in dye wastewater. In order to remove the disperse dyes effectively in aqueous solution by chemical precipitation process, coagulation and flocculation tests were carried out using several coagulants on various reaction conditions. It was found that the Ferrous sulfate was the most effective coagulant for the removal of disperse dye(DB79), and we could get the best result for the removal of disperse dye(DB56) in the aspects of TOC removal efficiency and sludge yield. When the Ferrous sulfate dosage was 800mg/l, the sludge settling velocity was very fast$(SV_{30}=4\%)$, and the color was effectively removed in the disperse dye(DB79) solution. Although the color removal was ineffective when the Alum was used as a coagulant, the sludge yield decreased in comparison with the Ferrous sulfate or the Ferric sulfate being used in the disperse dye(DB56) solution. In order to decolorize disperse dye(DR17) by using biological treatment process, a strain which has potential ability to degrade disperse dyes was isolated from natural system. The optimal culture conditions of temperature and pH were found to be $40^{\circ}C\;and\;8.5\~9$, respectively. When yeast extract was mixed with polypeptone at the mixing ratio of 1:1 as a nitrogen source, decolorization efficiency was highest$(93\%)$ among the nitrogen sources. The strain screened was excellent to adjust to pH, and it seems to have ability to control pH needed to growth. The optimal culture conditions in concentration of $MgSO_{4.}\cdot7H_2O\;and\;KH_2PO_4$ were $0.1\%(w/v)\;and\;0.2\%(w/v)$, respectively. Strains degrading and decolorizing reactive dyes, RB198 and RR141 which were isolated from water system, are named RBK1 and RRK. And the cell growth characteristics of RBK1 and RRK were investigated. The optimal culture conditions of temperature and pH were found to be 30t' and 7.0, respectively. Optimum nitrogen source was peptone, and it was found that decolorization efficiencies by strains RBK1 and RRK, were $85\%\;and\;62\%$, respectively, with introduction of 4,000mg/l of peptone. In the case of RBK1, color removal efficiencies were very high below 400mg/l. Decolorization efficiency was over $90\%$ at 20hours of culture time. The Color degradation ability of RRK was lower than that of RBK1.