• Title/Summary/Keyword: CoSpace

Search Result 2,083, Processing Time 0.044 seconds

A Study of Co-Working Space Operation Strategy: Focused on Operation Elements Analysis by AHP Method (코워킹스페이스 운영전략 연구: AHP 기법을 통한 운영요소 분석을 중심으로)

  • Seo, Jong-Seok;Lee, Geun-Choon;Ock, Young-Seok
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.4
    • /
    • pp.157-165
    • /
    • 2015
  • The purpose of this study is to suggest a successful operating strategy of co-working space. Therefore, the operating elements were identified through a literature research. And then, verified through site investigation and interview of operation managers. We found out that the high level operating elements are 'Co-working management', 'Membership management' and 'Supporting management' And the low level elements of Co-working management are 'Relationship facilitation', 'Networking event & Party' and 'Community & Communication', Membership management's are 'Service diversity & Price plan', 'Promotion & PR' and 'Alliance & Partnership', Supporting management's are 'Space & Interior', 'Facility & Device, Solution' and 'Mentoring & Education'. And the questionnaire was designed and conducted to Co-working space operators through the AHP method. As a result of the collected data analyzing, the highest priority was the operational element 'Community & Communication', and 'space and interior' is next, 'Service diversity & Price plan' is the third. The results were discussed with the relevant experts and it presents the following operating strategies. First, to create an environment suitable to voluntary coworking is the most important element. In particular, good management of 'Community & Communication' should be considered as a high priority operations strategy in a coworking space. Second, interior and space utilization helps in making the environment and atmosphere conducive to coworking. Office devices and facilities such as IT infra, printer, fax, scan, paper...etc are also important elements. But the reason why these necessary items are given a low priority is that these items don't need any special strategy. Third, in order to create a stable profit, 'Service diversity & Price plan' should be the characteristics of each coworking space because it will attract and secure enough customers. This study is valuable, it could be a great guideline for coworking space in an early stage to adopt operating model and strategy

  • PDF

Influences of Physical Work Environment on Job Satisfaction and Job Performance -Focusing on Personal Working, Co-Working and Amenity Space- (중소기업의 물리적 업무환경이 직무만족 및 직무성과에 미치는 영향 -개인집중업 공간, 협업 공간, 어메니티 공간을 중심으로-)

  • Ahn, Hyang-Cha;Lee, Sang-Jik
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.261-271
    • /
    • 2021
  • This study was conducted to empirically analyze the effect of the physical work environment of SMEs on work satisfaction and work performance. For the research, the physical work environment was subdivided into Focusing on Personal Working space, co-working space, and amenity space to establish a research model. For empirical analysis, a questionnaire survey was conducted targeting small and medium-sized enterprises(SMEs) workers. 250 valid copies were taken for analysis. Hypotheses were tested by multiple regression using SPSS 24. The study results were as follows. Focusing on Personal working space, co-working space, and amenity space all had a significant positive (+) effect on job satisfaction of SME employees. In addition, Focusing on personal working space, co-working space had a significant positive (+) effect on job performance. Amenity space was not tested for a significant influence on job performance. The contribution of this study was to identify the causal relationship between the physical work environment and the employee's job satisfaction and job performance in the absence of studies. In future research, it is ultimately necessary to identify the relationship with the business performance of a company.

Tracing the earliest phases of star formation: A pilot survey of Planck Cold Clumps

  • Yi, Hee-Weon;Lee, Jeong-Eun;Liu, Tie;Kim, Kee-Tae;Wu, Yuefang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.54.1-54.1
    • /
    • 2015
  • We observed 38 Planck Cold Clumps (PCCs) in the $850{\mu}m$ dust continuum emission using the JCMT/SCUBA-2, and detected the emission in 15 clumps containing dense cores. In this poster we present the preliminary results. The PCCs are cold, dense, and thus, they are considered as objects in the early evolutionary stages of star formation. The sources in our sample were selected based on the Purple Mountain Observatory (PMO) 13CO (1-0) integrated intensity maps. In order to examine whether these cores detected in $850{\mu}m$ continuum have potential to be prestellar cores, we compare each core mass estimated from the $850{\mu}m$ continuum with the Virial mass and Bonnor-Ebert (BE) mass calculated from the 13CO (1-0) or C18O (1-0) spectra. By comparing the two column densities from the dust continuum and the 13CO (1-0) or C18O (1-0) line, we also derive the CO depletion factor, which could be an indicator of core evolution. The moment maps of the 13CO (1-0) line are used to study the physical properties (e.g. kinematics, turbulence) of PCCs. We investigate difference between the sources with and without detectable $850{\mu}m$ emission to study the formation conditions of dense cores.

  • PDF

Comparison of the PMV and $CO_2$ Concentration, Energy Consumption Characteristics of Central Air-Conditioning System and System Air-Conditioner with Ventilation System for Large Space (중형공간에서 중앙공조방식과 시스템에어컨 방식에 따른 PMV와 $CO_2$농도, 에너지소비량 비교)

  • Sung, Sang-Chul;Noh, Kwang-Chul;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.298-303
    • /
    • 2008
  • PMV, $CO_2$ and the energy consumption performance were numerically investigated in a large space with air-conditioning systems of four type. The numerical results showed that thermal comforts in the occupied zone are nearly similar in three systems except 3-way wall type system air-conditioner with ventilation system installed 2.2m height from the bottom. In case of 3-way wall type system air-conditioner the energy consumption for cooling loads was reduced about 25.5% compared to other air-conditioning systems. From the viewpoint of IAQ, it was turned out that system air-conditioner with ventilation system became worse about 20% compared to central air-conditioning systems for cooling load. The PMV, $CO_2$ concentration and energy consumption of all systems for heating loads were similar in a large space considered.

  • PDF

The Effect of the Distance Between $CO_2$ Agent Nozzle and Wall ($CO_2$소화제 노즐과 벽간 거리의 영향)

  • Park Chan-Su
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.27-34
    • /
    • 2004
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the effect of flow and CO₂ mass transfer according to the distance between the CO₂ nozzle of CO₂ fire fighting system and the rear wall in a protection space. Flow fields and CO₂ concentration fields were measured. The different recirculation flow form and wall jet was developed according to increasing the distance between CO₂ nozzles and rear wall. In all the case, CO₂ mass transfer was generated toward the center of a protection space from each walls, but the CO₂ mass fraction of front and rear areas based on CO₂ nozzles showed higher or lower by increasing the distance between CO₂ nozzle and rear wall.

Development of Passive-Type Daylighting System for Large Space (대공간 적용을 위한 패시브형 자연채광시스템 개발)

  • Sung, Tae-Kyung;Park, Yeon-Min;Kim, Joung-Min;Lee, Chung-Sik;Lee, Euol-Young;Joung, Che-Bong;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.1-10
    • /
    • 2015
  • Whereas recent domestic buildings and industrial facilities are being constructed as large as possible, the daylighting systems for the large space have rarely been developed. Domestic situation has been reported as only several small or medium sized daylighting systems have been developed, and the large scaled systems have entirely being imported from abroad. We have developed a large scaled daylighting system for the big space. The developed system have been evaluated in terms of the average system efficiency and daylighting factor. Each results are shown with tabulated experimental data.