• Title/Summary/Keyword: Co-working

Search Result 952, Processing Time 0.028 seconds

Relationship between Psychosocial Factors, Job Stress Contents, Fatigue Symptoms and Quality of Nursing Services among General Hospital Nurses (종합병원 간호사들의 사회심리적 요인, 직무스트레스 및 피로와 간호서비스의 질과의 관련성)

  • Lee, Myung-Jun;Yoon, Seok-Han;Cho, Young-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.569-581
    • /
    • 2016
  • The purpose of this study was to define the quality of nursing services in relation to a nurse's psychosocial factors (type A behavior pattern, self-esteem, locus of control, and anxiety), job stress, and fatigue. This study targeted 503 nurses currently working at one of six general hospitals in Daejeon city, the data were collected by a self-administered questionnaire, which was surveyed from April 1 to June 30, 2014. According to multivariate logistic regression analysis, the high self-esteem, locus of control, and strong support by supervisor and co-workers decrease the risk of a low career quality. In contrast, high situational fatigue and overall fatigue increase the risk of a low career quality. According to the results of hierarchical multiple regression analysis, the quality of nursing services increased with age, the subjective health condition was satisfying, aptitude corresponded to the jobs, self-esteem was high, anxiety was low, support by co-workers was strong, and the overall fatigue was low. Above results suggest that the quality of nursing services of nurses who work at a general hospital has a strong correlation with the psychosocial factors, job stress, and fatigue.

Integrated Security Management with MCGA in IPv6 Network (IPv6 네트워크 환경에서 MCGA를 고려한 통합적인 보안관리 방안)

  • Oh, Ha-Young;Chae, Ki-Joon;Bang, Hyo-Chan;Na, Jung-Chan
    • The KIPS Transactions:PartC
    • /
    • v.14C no.1 s.111
    • /
    • pp.27-38
    • /
    • 2007
  • IPv6 has appeared for solving the address exhaustion of IPv4 and for guaranteeing the problems of security and QoS. It occurs the unexpected new attacks of IPv6 as well as the existing attacks of IPv4 because of the increasing address space to 128bits and the address hierarchies for efficient network management and additions of the new messages between nodes and routers like neighbor discovery and auto address configuration for the various comfortable services. For the successful transition from IPv4 to IPv6, we should get the secure compatibility between IPv4 hosts or routers working based on secure and systematic policy and IPv6. Network manager should design security technologies for efficient management in IPv4/IPv6 co-existence network and IPv6 network and security management framework designation. In this paper, we inspected the characteristics of IPv4 and IPv6, study on security requirement for efficient security management of various attacks, protocol, service in IPv4/IPv6 co-existence and IPv6 network, and finally suggest integrated solution about security vulnerability of IPv6 network in considering of analysis of IPv6 system, host and application, IPv6 characteristics, modified CGA(MCGA).

Electrochemical Quantitative Analysis of Mn(II) for the Study of Mn-Dissolution Behavior of LiMn2O4 (LiMn2O4의 Mn용출 현상 연구를 위한 전기화학적 Mn(II) 정량 분석법)

  • Son, Hwa-Young;Lee, Min-Young;Ko, Hyoung-Shin;Lee, Ho-Chun
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.131-137
    • /
    • 2011
  • A simple and rapid electrochemical method for the quantitative analysis of $Mn^{2+}$ ion is demonstrated with a view to examine the $Mn^{2+}$ dissolution behavior of $LiMn_2O_4$. The method described herein is based on the oxidation reaction of $Mn^{2+}$ to $Mn^{4+}(MnO_2)$ in aqueous buffer solution. Under the optimum condition (pH 8.9 0.04 M $NH_3-NH_4Cl$ buffer solution and glassy carbon working electrode), the linear range of $5{\mu}M-100{\mu}M$ (0.275-5.5 ppm) [$Mn^{2+}$] is obtained for the Linear sweep voltammetry(LSV) and $0.2{\mu}M-10{\mu}M$ (0.011-0.55 ppm) [$Mn^{2+}$] for the differential pulse voltammetry (DPV), respectively. It is also noted that the oxidation reaction of $Mn^{2+}$ ion is reduced with increasing amount of the electrolyte ($LiPF_6$, EC, EMC) added to the measuring solution, which is found to be mainly due to $LiPF_6$ and EC rather than EMC.

Analysis of Consumption of Homemade Organically Processed Food Analysis of The Carbon Emission Reduction Effect from No-Tillage in Pepper (Capsicum annuum L.) Cultivation (고추의 무경운 재배에 따른 탄소저감효과 분석)

  • Lee, Gil-Zae;Choi, Yoon-Sil;Yang, Seung-Koo;Lee, Jin-Hong;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.4
    • /
    • pp.503-518
    • /
    • 2012
  • Korean type of no-tillage cultivation method which was applied on this study used the ridge and the furrow and constantly recycling them as it was suitable for Korea's weather and farming conditions. This no-tillage cultivation was reported to have little negative impact such as reduction of production (Kwon et al., 1997). In addition, it was found to have a lot of benefits as it requires less agro-materials and energy costs as well as shortened working hours because tillage operation is not needed. (Yang et al., 2012). According to an analysis, no-tillage cultivation can reduce greenhouse gas emissions by $344.7kgCO^2$ (58%) in every 10a ($1,000m^2$) compared to ordinary pepper farming technique (Korea averages). Direct-indirect reduction effects from using fertilizer and using less amount of energy were 92% and 44% respectively both of which can be considered very high. Besides the direct effects of no-tillage cultivation, soil management using no-tillage technique raises carbon sequestration effect on soil as time goes on (West & Marland, 2002), that is why the technique is expected to have constant carbon emission reduction effect. For theses reasons, distribution and expansion of Korean type no-tillage cultivation are expected to play a role as major agro-green technologies for achieving our goal of reducing greenhouse gas emissions in agricultural sector.

Formulation of Alternative Non-Aqueous Cleaning Agents to Chlorofluorocarbon Compounds for Cleaning Flux, Solder and Grease (Flux, Solder 및 Grease 세정용 CFC 대체 비수계 세정제 배합 연구)

  • Jung, Young Woo;Lee, Ho Yeoul;Lee, Myoung Jin;Song, Ah Ram;Bae, Jae Heum
    • Clean Technology
    • /
    • v.12 no.4
    • /
    • pp.250-258
    • /
    • 2006
  • CFC compounds such as CFC-113 and 1,1,1-TCE, etc. have been used in various industries due to their excellent chemical stability, thermodynamic characteristics, non-inflammability and anti-corrosiveness. However, in oder to protect the earth environment, "the Montreal Protocol on substances that deplete the ozone layer" was adopted in 1989 for prevention of production and utilization of these CFC compounds and alternative cleaning agent have been required in the industry. The objective of this study is to develop non-aqueous cleaning agents that do not require major change of cleaning system, have excellent cleaning efficiency, are favorable to the environment, are harmless to the human body, and are not generated corrosive materials. In this work, non-aqueous cleaning agents have been formulated with glycol ether series and paraffinic hydrocarbon series with siloxane, and their physical properties and cleaning efficiencies were analyzed and compared with those of regulated materials. As a result of physical properties measurement of the formulated cleaning agents, it is expected that they may have good penetration ability into contaminated materials due to their properties with low density and low surface tension. Measurement of flash point and vapor pressure of the cleaning agents will be helpful for evaluation of their safety and working environment. The experimental results of cleaning flux, solder and grease by the formulated cleaning agents show that their cleaning abilities of soils were good and that there were no residues on the substance after cleaning. Therefore, alternative cleaning agents which have equivalent cleaning ability to regulating materials, good penetration ability and low hazard to human body, have been developed in this work.

  • PDF

A benchmarking of electricity industry for improving the integrated water resources management (IWRM) policy (통합물관리 정책실현을 위한 전력산업 벤치마킹 연구)

  • Kim, Dong Hyun;Kim, Taesoon;Jung, Heoncheol;Jeong, Eunsung;Lee, Seung Oh;Jung, Changsam
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.spc1
    • /
    • pp.785-795
    • /
    • 2020
  • Recently, the integrated management of the quantity and quality of water was been derived by the Ministry of Environment in Korea. This reconstruction in the national government organization can be recognized as the major politic measure. For this IWRM (Integrated Water Resources Management), it is necessary to be able to fairly distribute, operate and manage water resources in a situation where related techniques are needed to fully support, such as measuring exactly the demand and supply of water resources. The reason why IWRM is difficult, despite the development of related technologies, is because the management entities are highly diverse and their interests are much complicated. Thus, this study is tried to suggest specific improvement for current policies by benchmarking the KPX (Korea Power Exchange). In the field of water management as similar to the electric industry, there is an essential need for a working-level organization that can manage, control, monitor, and regulate water resources with practical and plenipotentiary control like the non-profit organization, KPX. Such time has come for decisive policy changes through benchmarking the structure, system, productivity, and challenges of the electricity industry in the water policy.

Design of Portable Welded-Nitrogen Vessel (11 kg, 10 L and 50 bar) for Shipbuilding (선박용 휴대형 질소용기(11 kg, 10 L 및 50 bar)의 두께 및 외형 설계)

  • Seong, Hansaem;Kim, Jaeyeol;Eom, Taejin;Kawk, Hyo Seo;Lee, Kwang O;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.263-270
    • /
    • 2017
  • The shipbuilding industry uses large stationary tanks to store low-pressure air, which is used to open and close large shut-off valves. However, when supplying air from the tank to a distant valve, there are problems related to the need for supplementary pipes and the pressure drop during transportation. In this study, a portable welded vessel for storing high-pressure nitrogen (11 kg, 10 L, and 50 bar) was designed to prevent air leakage and improve the convenience of workers. This pressure vessel was elliptical to reduce the number of welded parts, which are structurally weak. The thickness and ratio of the major and minor axes of the pressure vessel were calculated to verify its structure stability at the working pressure (50 bar), and that the proposed weight and capacity were satisfactory. The residual stress caused by the welding process was calculated by performing a transient thermal-structural coupled field analysis using the ANSYS parametric design language (APDL), and the fatigue life of the vessel was verified based on the Goodman criterion.

A Study on the Emissions Characteristics of a LPG Vehicle According to Various Test Modes and Ambient Conditions (다양한 시험모드와 환경조건에 따른 LPG 차량의 배출특성 연구)

  • Lee, Min-Ho;Ha, Jong-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • As the interest on the air pollution is gradually rising up at home and abroad, automotive and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward various main issues : whether PM emissions should be regulated for diesel and gasoline vehicles and whether gasoline and LPG powered vehicles can be further neglected from PM emission inventories. Finally, the greenhouse gas regulation has been discussed including automotive emission regulation. The greenhouse gas and emissions of automotive had many problem that cause of ambient pollution, health effects. Based on various test modes and ambient conditions, this paper discusses the characteristics of LPG on exhaust emissions and greenhouse gases. Also, this paper assessed emission characteristics due to the test temperature. These test temperature were performed by dividing the temperature of the test mode and the lowest local temperature in winter. Through this study, the correlation of vehicle test mode and ambient condition, exhaust emission, greenhouse gas emission was analyzed.

Development of Dry Process Caisson Method for Maintenance of Submerged Harbor Structure (수중 항만구조물의 유지보수를 위한 건식 케이슨 공법 개발)

  • Lee Joong-Woo;Oh Dong-Hoon;Kwak Seung-Kyu;Kim Sung-Tae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.163-170
    • /
    • 2006
  • Together with the trend of enhancement in domestic industrial development and economic progress due to import and export, the demand for construction of the roads, bridges, especially port facilities, and several coastal protection and ocean structures is increasing rapidly. MOMAF of Korean Government is driving construction of 9 new ports and renovation of the existing fishery ports. Among these structures most of bridge base, wharves, dolphins, quays, and jetties are being newly built of steel or concrete pile. As the base, supporting bulkheads, and piles are underwater after construction, it is difficult to figure out the status of structures and not enough to get maintenance and strengthen the structures. Every year, moreover, these works suck the government budget due to higher incomplete maintenance expense for protection from corrosions of structures and increased underwater construction period. For the purpose of cutting down the expense of government budget, it is necessary to extend the life cycle of the existing structures. Therefore, we developed a new method for maintenance of submerged structures near the waterline by allowing dry work environment with the floating caisson. The method shows easy to move around the working area and handle. It also showed not only a significant reduction maintenance expenses and time for anti-corrosion work but also better protection. This will be a milestone to reduce the maintenance and construction expenses for the shore and water structures.

  • PDF

Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings (일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가)

  • Chung, Eun Kyo;Kim, Ki Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.