• 제목/요약/키워드: Co-operation

검색결과 3,065건 처리시간 0.038초

영구자석 동기 서보 전동기의 제어에 관한 연구 (A study on Permanent Magnet Synchronous Servo Motor Control)

  • 김종구;최욱돈;정명길;이현상;김명찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.543-547
    • /
    • 1991
  • This paper illustrates maximum torque per ampare radio operation and efficiency operation, which are prevalently applied to the control of permanent magnet synchronous motor(PMSM). Maximum torque per ampare ratio operation minimizes the copper loss of PMSM and maximum efficiency operation minimizes the total loss of PMSM. To verify the difference of these method, simulation and experiment results applied to IPMSM(Interior type PMSM) and SPMSM(Surface mounted PMSM) are presented.

  • PDF

반연속식과 직렬식 공정에서 Chlorella sp. HA-1의 $CO_2$ 고정화 특성

  • 이재영;권태순;양지원
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.455-456
    • /
    • 2000
  • Characteristics of $CO_2$ fixation by Chlorella sp. HA-1 were studied in a semi-continuous mode in a series operation. A high $CO_2$ fixation rate for a long time was obtained, when the method of semi-continuous mode was employed, in which the controlling parameter was the dilution ratio. A constant $CO_2$ fixation rate was maintained even when the dilution ratio was increased with the increment of 0.1 at the initial value of 0.5. The method of series operation was used to improve the efficiency of $CO_2$ fixation. The total amount of $CO_2$ fixation was proportion to the number of reactor in series operation.

  • PDF

노면전철형식의 경량전철 운전규정에 관한 연구 (The Study of Operation provision for lightrail of tram formats)

  • 이수환;김유호;이훈구;편선호;황현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1023-1024
    • /
    • 2008
  • The road surface scripture season must be interpreted with hitherto whole aspect line scripture season different. TRAM (street cars) it respects an operation it stands and back must be operated the bus which runs place and riding grade different public transportation means and to be mixed. With the numerous crossroads zebra crossing and the coat platform must operate back. The role of the operation article most is important. It undergoes the influence of traffic signal specially directly. It considers each facility etc. of the road and must construct a proper equipment in him with connection method of the signal system which it follows in the middle urethra. Must secure the fixed time characteristic of the operation which road surface scripture season is efficient and expression speed and operation. In order the [le] according to interface plan with traffic signal it does to consider a traffic signal first of all. This the research of operation provision is necessary.

  • PDF

배전운영 시스템에서 상시개방 연계 스위치 투입에 의한 루프 운전 중 구간전압 계산 방법 (Section Voltage Calculation while a Loop Operation by Tie-Switch Close in a Distribution Management System)

  • 서정수;임일형;박종호;신용학;최면송
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.397-403
    • /
    • 2016
  • Generally, an electrical distribution configuration is a radial system with one-way current in a distribution management system (DMS). All feeders in a DMS have tie-switches to make radial system. Sometimes, DMS should change a tie-switch for operation. In that case, the tie-switch has to be closed first; then a switch is opened as another tie-switch in order to prevent blackout for customers. At the moment when the tie-switch is closed, distribution system is operated in a loop state, not radial. Before the loop operation, DMS operator has to check any expected events for stable distribution system operation; and the most important event is a mis-operation of a protection relay. In addition, DMS operator should check voltage profile violation but a calculation method of section voltages had not been used. Thus, this paper proposes a calculation method of section voltages at a loop operation in a DMS. The proposed calculation algorithm is verified by Matlap Simulink.

신재생연료 혼소를 통한 미분탄 화력 발전소의 CO2 저감 방안 도출 (Approach to Reduce CO2 by Renewable Fuel Cofiring for a Pulverized Coal Fired Boiler)

  • 김태현;최상민;양원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.19-20
    • /
    • 2013
  • The cofiring of renewable fuel in coal fired boilers is an attractive option to mitigate $CO_2$ emissions, since it is relatively low cost option for efficiently converting renewable fuel to electricity by adding biomass as partial substitute of coal. However, it would lead to reduce plant efficiency and flexibility in operation, and increase operation cost and capital cost associated with renewable fuels handling and firing equipment. The aim of this study is to investigate reduction of carbon dioxide at varying percentage of biomass in fuel blend to the boiler biomass, and estimate operation and capital cost. Wood pellet, PKS (palm kernel shell), EFB (empty fruit bunch) and sludge are considered as a renewable fuels for a cofiring with coal. Several approaches by the cofiring ratio are chosen from past plant demonstrations and commercial cofiring operation, and they are evaluated and discussed for CO2 reduction and cost estimation.

  • PDF

Analysis of Tropospheric Carbon Monoxide over East Asia

  • Lee, S.H.;Choi, G.H.;Lim, H.S.;Lee, J.H.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.615-617
    • /
    • 2003
  • Carbon monoxide (CO) is one of the important trace gases because its concentration in the troposphere directly influences the concentrations of tropospheric hydroxyl (OH), which controls the lifetimes of tropospheric trace gases. CO traces the transport of global and regional pollutants from industrial activities and large scale biomass burning. The distributions of CO were analyzed using the MOPITT data for East Asia, which were compared with the ozone distributions. In general, seasonal CO variations are characterized by a peak in the spring, which decrease in the summer. The monthly average for CO shows a similar profile to that for O$_3$. This fact clearly indicates that the high concentration of CO in the spring is possibly due to one of two causes: the photochemical production of CO in the troposphere, or the transport of the CO into East Asia. The seasonal cycles for CO and O$_3$ in East Asia are extensively influenced by the seasonal exchanges of different air mass types due to the Asian monsoon. The continental air masses contain high concentrations of O$_3$ and CO, due to the higher continental background concentrations, and sometimes to the contribution from regional pollution. In summer this transport pattern is reversed, where the Pacific marine air masses that prevail over Korea bring low concentrations of CO and O$_3$, which tend to give the apparent summer minimums.

  • PDF

Biological Fixation of $CO_2$ by Chlorella sp. HA-1 in a Semi-Continuous and Series Reactor System

  • LEE JAE-YOUNG;KWON TAE-SOON;BAEK KITAE;YANG JI-WON
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권3호
    • /
    • pp.461-465
    • /
    • 2005
  • Characteristics of biological $CO_2$ fixation by Chlorella sp. HA-1 were investigated in a semi-continuous and series reactor system using an internally illuminated photobioreactor to overcome shortcomings of physicochemical technologies such as adsorption and membrane separation. High $CO_2$ fixation rate was achieved in the semi-continuous reactor system, in which the dilution ratios of the culture medium were controlled. The average $CO_2$ fixation rate was maintained almost constantly when the dilution ratio increased by 0.1 increment from the initial value of 0.5. The total removal efficiency of $CO_2$ was enhanced by employing a series reactor system. The average $CO_2$ fixation rate increased until 4.013 g $CO_2\;day^{-1}$ in a series operation of four reactors, compared to 0.986 g $CO_2\;day^{-1}$ in a batch operation mode. The total $CO_2$ fixation rate was proportional to the number of reactors used in the series reactor system. In the series reactor system of semi-continuous operation, a large amount of $CO_2$ was removed continuously for 30 days. These results showed that the present reactor systems are efficient and economically feasible for a biological $CO_2$ fixation.

공작기계 주축용 스핀들 전동기 구동에 관한 연구 (A Study on the Spindle Motor Drive for the Spindle of Machining Center)

  • 한영성;안성찬;송종환;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2110-2112
    • /
    • 1997
  • The induction motor drive for the spindle of machining center is required to do not only a constant torque operation in low speed region(below base rpm), but also a constant power operation in high speed region(beyond base rpm). Also, control voltage shortage due to high speed operation must be overcome. The vector controlled inverter system with input 3 phase pwm converter is designed for that kind of condition. We experimented the performance of the inverter system with spindle motor made by Hyosung industries co.

  • PDF

제트 팬 가동위치에 따른 장대터널 내 CO 농도 변화율에 대한 전산해석 (Investigate on the rate of change of CO concentration in a tunnel under changed position of the jet fans by using numerical method)

  • 민재홍;김대현;정진택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2765-2770
    • /
    • 2008
  • The purpose of tunnel ventilation system for long road tunnels is to keep certain levels of Visibility Index and the concentration of CO. Additional equipments such as jet fans are used in road tunnel to discharge pollutants in the road tunnel. The control algorism of tunnel ventilation system takes the value of sensors as input, and then gives the operation method of jet fans in tunnel as output. Information on the variation of CO concentration in tunnel when jet fans are running is needed to minimize their operation time. Numerical analysis is used in this paper because of the difficulty of conducting experiments under standard condition for ventilation of road tunnel. The concentration of CO has been calculated by using 3-dimensional CFD under transient condition with speed of cars, quantity of air ventilation, and the results for various operation position of jet fans are compared.

  • PDF