• 제목/요약/키워드: Co-inserted

검색결과 252건 처리시간 0.024초

임플란트 주위염 치료 효과의 프랙탈 분석 (Fractal analysis of the surgical treatment of ligature-induced peri-implantitis in dogs)

  • 김학균;김진수
    • Imaging Science in Dentistry
    • /
    • 제40권3호
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose : To evaluate the effect of surgical treatment of ligature-induced peri-implantitis in dogs using fractal analysis. Also, the capabilities of fractal analysis as bone analysis techniques were compared with those of histomorphometric analysis. Materials and Methods : A total of 24 implants were inserted in 6 dogs. After a 3-months, experimental periimplantitis characterized by a bone loss of about 3 mm was established by inducing with wires. Surgical treatment involving flap procedure, debridement of implants surface with chlorhexidine and saline (group 1), guided bone regeneration (GBR) with absorbable collagen membrane and mineralized bone graft (group 2), and $CO_2$ laser application with GBR (group 3) were performed. After animals were sacrificed in 8 and 16 weeks respectively, bone sections including implants were made. Fractal dimensions were calculated by box-counting method on the skeletonized images, made from each region of interest, including five screws at medial and distal aspects of implant, were selected. Results : Statistically significant differences in the fractal dimensions between the group 1($0.9340{\pm}0.0126$) and group 3($0.9783{\pm}0.0118$) at 16 weeks were found (P<0.05). The fractal dimension was statistically significant different between 8($0.9395{\pm}0.0283$) and 16 weeks in group 3 (P<0.05). These results were similar with the result of the evaluation of new bone formation in histomorphometric analysis. Conclusions : Treatment of experimental peri-implantitis by using $CO_2$ laser with GBR is more useful than other treatments in the formation of new bone and also the tendency of fractal dimension to increase relative to healing time may be a useful means of evaluating.

초기 균열길이 및 섬유방향이 CFRP/GFRP 하이브리드 적층재의 층간 파괴에 미치는 영향 (The Effects of the Initial Crack Length and Fiber Orientation on the Interlaminar Delamination of the CFRP/GFRP Hybrid Laminate)

  • 권오헌;권우덕;강지웅
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.12-17
    • /
    • 2013
  • Considering the wind power system and the rotor blades which are composed of much technology, the wind power blade would be the most dangerous part because it revolves at high speed and weighs about dozens of tons, if the accident happens. Therefore, the light weight composite materials have been replacing as substitutional materials. The object of this study is to examine the delamination and damage for CFRP/GFRP hybrid composite that is used for strength improvement of a wind power blade. The influence of the initial crack length and fiber orientation for the interlaminar delamination was exposed for the blade safety. Plain woven CFRP instead of GFRP was inserted into the layer of the box spar for improving the strength and blade life. DCB(Double Cantilever Beam) specimen was used for evaluating fracture toughness and damage evaluation of interlaminar delamination. The material used in the experiment is a commercial material known as CF 3327 EPC in plain woven carbon prepreg(Hankuk Carbon Co.) and UD glass fiber prepreg(Hyundai Fiber Co.). From the results, crack growth rate is not so different according to the variation of the initial crack length. Mode I interlamainar fracture toughness of fiber direction $0^{\circ}$ is higher than that of $45^{\circ}$. Interlaminar fracture has an effect on fiber direction and K decreased with lower value according to increasing initial crack length. Also energy release rate fracture toughness was evaluated because CFRP/GFRP hybrid composite with a different thickness is under the mixed mode loading condition. The interlaminar fracture was almost governed by mode I fracture even though the mixed mode.

Potential of polylactic-co-glycolic acid (PLGA) for delivery Jembrana disease DNA vaccine Model (pEGFP-C1-tat)

  • Unsunnidhal, Lalu;Wasito, Raden;Setyawan, Erif Maha Nugraha;Warsani, Ziana;Kusumawati, Asmarani
    • Journal of Veterinary Science
    • /
    • 제22권6호
    • /
    • pp.76.1-76.15
    • /
    • 2021
  • Background: The development of a vaccine for Jembrana disease is needed to prevent losses in Indonesia's Bali cattle industry. A DNA vaccine model (pEGFP-C1-tat) that requires a functional delivery system will be developed. Polylactic-co-glycolic acid (PLGA) may have potential as a delivery system for the vaccine model. Objectives: This study aims to evaluate the in vitro potential of PLGA as a delivery system for pEGFP-C1-tat. Methods: Consensus and codon optimization for the tat gene was completed using a bioinformatic method, and the product was inserted into a pEGFP-C1 vector. Cloning of the pEGFP-C1-tat was successfully performed, and polymerase chain reaction (PCR) and restriction analysis confirmed DNA isolation. PLGA-pEGFP-C1-tat solutions were prepared for encapsulated formulation testing, physicochemical characterization, stability testing with DNase I, and cytotoxicity testing. The PLGA-pEGFP-C1-tat solutions were transfected in HeLa cells, and gene expression was observed by fluorescent microscopy and real-time PCR. Results: The successful acquisition of transformant bacteria was confirmed by PCR. The PLGA:DNA:polyvinyl alcohol ratio formulation with optimal encapsulation was 4%:0.5%:2%, physicochemical characterization of PLGA revealed a polydispersity index value of 0.246, a particle size of 925 nm, and a zeta potential value of -2.31 mV. PLGA succeeded in protecting pEGFP-C1-tat from enzymatic degradation, and the percentage viability from the cytotoxicity test of PLGA-pEGFP-C1-tat was 98.03%. The PLGA-pEGFP-C1-tat demonstrated luminescence of the EGFP-tat fusion protein and mRNA transcription was detected. Conclusions: PLGA has good potential as a delivery system for pEGFP-C1-tat.

Anchor 볼트 형태의 Strain Gauge 센서를 이용한 지게차 적재 중량 측정 시스템 (Forklift Weight Measurement System using Anchor Bolt Type Strain Gauge Sensor)

  • 한치문;임춘식;이성렬
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.200-206
    • /
    • 2019
  • 산업현장에서의 지게차의 전복에 의한 안전사고 빈도가 매우 높은 편이다. 지게차 전복의 가장 큰 원인은 과적으로, 이를 방지하기 위해서 적재 중량을 측정해야 한다. 가장 보편적인 적재 중량 측정 방식은 로드셀(load cell)로 측정 오차가 적은 장점이 있지만 설치 단가가 비싸다는 점 때문에 산업현장에 쉽게 적용하지 못하고 있다. 본 연구는 로드 셀 방식의 대안으로 제시되었지만 측량 정밀도가 높지 않은 strain gauge 센싱 방식을 적용한 지게차 새로운 적재 중량 측정 시스템을 제안한다. 센서의 측량 정밀도와 내구성을 높이기 위해 4개의 센서가 각각 4개의 anchor bolt에 삽입되는 구조로 제작하였다. 제작된 anchor 볼트 형태의 strain gauge 센서를 지게차에 적용하여 측정한 결과 1%의 측정 오차를 얻을 수 있었다.

A Preliminary Study on Evaluation of TimeDependent Radionuclide Removal Performance Using Artificial Intelligence for Biological Adsorbents

  • Janghee Lee;Seungsoo Jang;Min-Jae Lee;Woo-Sung Cho;Joo Yeon Kim;Sangsoo Han;Sung Gyun Shin;Sun Young Lee;Dae Hyuk Jang;Miyong Yun;Song Hyun Kim
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.175-183
    • /
    • 2023
  • Background: Recently, biological adsorbents have been developed for removing radionuclides from radioactive liquid waste due to their high selectivity, eco-friendliness, and renewability. However, since they can be damaged by radiation in radioactive waste, a method for estimating the bio-adsorbent performance as a time should consider the radiation damages in terms of their renewability. This paper aims to develop a simulation method that applies a deep learning technique to rapidly and accurately estimate the adsorption performance of bio-adsorbents when inserted into liquid radioactive waste. Materials and Methods: A model that describes various interactions between a bio-adsorbent and liquid has been constructed using numerical methods to estimate the adsorption capacity of the bio-adsorbent. To generate datasets for machine learning, Monte Carlo N-Particle (MCNP) simulations were conducted while considering radioactive concentrations in the adsorbent column. Results and Discussion: Compared with the result of the conventional method, the proposed method indicates that the accuracy is in good agreement, within 0.99% and 0.06% for the R2 score and mean absolute percentage error, respectively. Furthermore, the estimation speed is improved by over 30 times. Conclusion: Note that an artificial neural network can rapidly and accurately estimate the survival rate of a bio-adsorbent from radiation ionization compared with the MCNP simulation and can determine if the bio-adsorbents are reusable.

대형싸이로에 있어서 훈증제의 수직적 침투력 (A Study on Gravity Penetration of Fumigants in the Jumbo Silo)

  • 하재규;오정우;유기열;김병호
    • 한국응용곤충학회지
    • /
    • 제20권2호
    • /
    • pp.103-106
    • /
    • 1981
  • 이 시험은 수직싸이로에서 대두를 훈증소독하는 경우 훈증제별로 침투확산력을 조사할 목적으로 실시한것으로써 그 결과를 요약하면 다음과 같다. 1. 대두의 표면에 M.B를 단독으로 투약한 경우 M.B Gas의 침투확산속도는 대만히 빨라 투약후 4시간 이내에 싸이로 기부에 60mg/l 이상의 M.B Gas가 검출되었으며 10시간 이후로부터는 M.B Gas의 농도가 차 감소하는 경향이었다. 2. M.B Gas의 Carrier로 $CO_2$ Gas를 동시에 사용하였을 때는 M.B Gas의 침투확산속도가 M.B 단독 사용시보다 더욱 빨라져 투약후 1.5 시간이내에 싸이로 기부의 M.B Gas 농도는 70mg/l 이상을 나타내었다. 3. Phostoxin을 투약한 경우는 M.B를 투약한 경우 와는 반대로 침투확산력이 매우 미약하여 투약후 48시간동안 싸이로의 기부에서 10mg/l 이상의 농도를 검지할 수 없었다. 4. 소독효과를 조사하기 위해서 공시충으로 쌀바구미를 싸이로 기부에 삽입하였던바 M.B 및 $CO_2$구에서 는 완전한 살충효과를 얻었으나 Phostoxin 사용구에서는 대부분 생충으로 발견되었다.

  • PDF

장애 환자의 전신 마취를 위한 세보플루란 흡입 유도 시 발생한 호흡 저하의 혈액 가스 분석 (Blood Gas Analysis of Respiratory Depression during Sevoflurane Inhalation Induction for General Anesthesia in the Disabled Patients)

  • 윤태완;김승오
    • 대한소아치과학회지
    • /
    • 제45권4호
    • /
    • pp.508-513
    • /
    • 2018
  • 세보플루란에 의한 일회 환기량은 낮은 용량에서는 호흡수의 증가로 안정적이다. 그러나 진정 깊이가 증가하면 폐포 환기는 세보플루란에 의해 감소되어 결과적으로는 $PaCO_2$가 증가한다. 호흡 억제의 발생은 깊이 진정된 장애 환자에서 심한 저산소증과 고탄산혈증의 위험을 증가시킨다. 세보플루란 흡입 마취는 여러 위험성이 내제되어 있으며 체내 산 염기 상태에 따라 혈역학적 변화가 발생하기에 예기치 못한 문제 상황이 발생할 수 있다. 세보플루란으로 장애인의 마취 유도 시 발생하는 호흡 억제로 인한 체내 산 염기 상태가 안정한지 알아보고자 이 연구를 진행하였다. 마취 유도는 4 vol% 세보플루란, 4 L/min 아산화질소, 4 L/min 산소를 자발 호흡 하에서 환자 안면부에 마스크를 거치하여 유도하였다. 그 뒤 환자의 의식소실 및 근육 긴장 완화 후 즉시 전문가에 의해 IV line을 거치한 뒤 정맥 채혈을 하여 정맥 내 혈액가스 분석을 하였다. 깊은 진정 상태에서 전체 환자의 평균 pH는 $7.36{\pm}0.06$으로 측정되었다. $PvCO_2$는 전체 환자에서는 평균 $48.8{\pm}8.50mmHg$로 측정되었다. $HCO_3{^-}$는 전체 환자에서 평균 $27.2{\pm}3.0mmol/L$로 측정되었다. 결론적으로 장애인을 대상으로 한 치과 진료시 세보플루란을 이용한 흡입 진정에 대한 체내 산 염기 반응은 비교적 안정적이었다.

벤치급 CO2 포집공정에서 흡수반응기의 내부구조에 따른 K-계열 고체흡수제의 성능평가 (Performance Evaluation of K-based Solid Sorbents Depending on the Internal Structure of the Carbonator in the Bench-scale CO2 Capture Process)

  • 김재영;임호;우제민;조성호;문종호;이승용;이효진;이창근;이종섭;민병무;박영철
    • Korean Chemical Engineering Research
    • /
    • 제55권3호
    • /
    • pp.419-425
    • /
    • 2017
  • 본 연구에서는 벤치급 건식 $CO_2$ 포집 성능평가 장치에서 흡수반응기 내부의 구조와 형태에 따른 K-계열 흡수제(KEP-CO2P2, 한국전력공사 전력연구원)의 성능특성을 확인하였다. 흡수반응기 혼합영역(mixing-zone)에 구조와 형태가 다르게 제작된 두 종류의 열교환기가 적용되었으며, 각각 CASE 1과 CASE 2로 나뉘어 동일한 조업조건으로 연속운전을 수행하였다. 연속운전동안 흡수반응 온도는 $75{\sim}80^{\circ}C$, 재생반응 온도는 $190{\sim}200^{\circ}C$, 그리고 반응기체($CO_2$) 농도는 12~14 vol%으로 설정하였다. 특히 흡수제의 흡수능 비교를 위해 흡수반응기 혼합영역의 차압을 400~500 mm$H_2O$로 유지하며 운전하였다. 또한 반응 후 채집한 시료는 반응성 비교를 위해 TGA를 이용하여 물성분석을 하였다. CASE 1 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 64.3%, 2.40 wt%으로 산출 되었고, CASE 2 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 81.0%, 4.66 wt%으로 산출되었다. 또한 반응 후 흡수제에 대한 TGA 측정 결과의 무게감량을 이용하여 흡수제의 동적흡수능을 계산한 결과, CASE 1과 CASE 2 실험에서 반응 후 흡수제의 동적흡수능은 각각 2.51 wt%와 4.89 wt%으로 산출되었다. 결론적으로 동일한 조업조건에서 흡수반응기 내부에 삽입되는 열교환기의 구조와 형태에 따라 흡수제의 성능 차이가 있는 것을 확인하였다.

라만 분광학과 분자모델링을 이용한 메탄 및 육불화황 혼합 가스 하이드레이트 성장 거동 연구 (Raman Spectroscopy and Molecular Modeling Study on the CH4 and SF6 Mixture Gas Hydrate Growth Behavior)

  • 임준혁;이주동;박성수;엄기헌;원용선
    • 청정기술
    • /
    • 제19권4호
    • /
    • pp.476-480
    • /
    • 2013
  • 라만 분광학과 분자 모델링을 이용하여 메탄과 육불화황의 혼합 기체 가스 하이드레이트의 성장거동을 연구하였다. 라만 분광학 결과에 의하면 메탄을 객체 가스로 사용할 경우 메탄이 물 분자로 이루어지는 가스 하이드레이트 호스트 구조 내의 큰 동공을 채우고 차례로 작은 동공이 채워지게 되는데 반하여 육불화황을 혼합한 경우 육불화황과 메탄이 경쟁적으로 큰 동공을 채우고 이어 작은 동공에는 메탄만 채워지는 방식으로 전체 가스 하이드레이트 구조가 안정화됨을 관찰하였다. 분자 모델링에 의한 결합에너지 계산 결과 큰 동공의 경우 육불화황은 -26.9 kcal/mol, 메탄은 -24.2 kcal/mol의 결합에너지를 보여 육불화황이 채워지는 것이 약간 더 안정함을 알 수 있었고 작은 동공의 경우 육불화황은 1.2 kcal/mol, 메탄은 -22.0 kcal/mol로 큰 크기의 육불화황이 작은 동공에는 채워질 수 없음을 보여주었다. 이와 같은 접근법은 향후 다양한 객체 기체 가스 하이드레이트의 성장거동을 예측하는데 적용될 수 있을 것이다.

MPEG 동영상 컨텐츠 보호를 위한 양자화-적응적 워터마킹 알고리즘 (A Quantization-adaptive Watermarking Algorithm to Protect MPEG Moving Picture Contents)

  • 김주혁;최현준;서영호;김동욱
    • 대한전자공학회논문지SP
    • /
    • 제42권6호
    • /
    • pp.149-158
    • /
    • 2005
  • 본 논문에서는 동영상 컨텐츠의 위${\cdot}$변조, 불법사용 및 복제를 방지하기 위하여 비가시성과 공격에 대한 강인성을 동시에 만족하는 blind 워터마킹 방법을 제안하였다. 이 방법은 MPEG-2 동영상 압축시스템을 대상으로 하며, 이 압축시스템의 적응적 양자화에 부합하도록 양자화 스케일 코드에 따라 삽입할 워터마크 비트 수를 조절하도록 설계하였다. 워터마크의 삽입위치는 영상의 주파수 특성에 따라 삽입할 영상블록을 선정하고, 선정된 영상블록의 가로, 세로, 대각선의 주파수 특성과 블록내의 각 계수의 주파수 특성을 고려하여 계수를 선정하였다. 또한 각 계수에 삽입할 워터마크 비트 수는 양자화 스텝을 고려하여 결정하였다. 이 알고리즘은 C/C++ 언어로 구현하였으며, 자체 제작한 MPEG-2 시스템을 테스트 베드로 하여 비가시성과 강인성을 실험하였다. 실험결과 삽입한 워터마크의 비가시성이 충분히 만족되었고, 일반적인 공격방법에 대해 추출된 워터마크의 에러율이 $10\%$ 이하의 강인성을 보였다. 따라서 제안한 방법은 MPEG-2 시스템을 사용하는 동영상 압축, 특히 네트워크 적응적 압축이 필요한 응용분야에서 매우 유용하게 사용될 수 있으리라 사료된다.