• Title/Summary/Keyword: Co-fire

Search Result 935, Processing Time 0.031 seconds

Research on the Reliability Improvement of Automatic Fire Alarm System (자동화재탐지설비의 신뢰성 개선에 관한 연구)

  • Son, Young-Jin;Lee, Young-Il;Lee, Sang-Hyeon
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.42-49
    • /
    • 2008
  • This research is to provide a scheme for an automatic fire alarm system with higher reliability through solving problems of malfunctioning (false or missing fire alarm) and power interruption (result from frequently unwanted activation, etc) of an automatic fire alarm system. A digital control system with microprocessor-based is proposed to reduce the possibility of malfunctioning through a combinational use of heat, smoke and CO sensors. Higher reliability could be achieved by these multiple sensors based fire detection system and fire distinction algorithm. In this research, we implemented actual fire detection system and conducted fire test to verify improvement on reliability.

FIRE WATER SYSTEM RELIABILITY IN INDUSTRIAL APPLICATIONS

  • James M. Dewey;Kim, Yong-Dal
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.526-533
    • /
    • 1997
  • Reliability of fire protection systems is often discussed, written about, and even put into codes and standards. However, reliability is seldom considered for the fire protection system as a whole. Why does this happen and why should the designer consider the system as a whole\ulcorner Existing codes and standards incorporate the concept of reliability usually In the form of key component redundancy for some parts of a system. The "Fire Safety Concepts Tree" presented in the National Fire Protection Association Guide 550, Guide to the Fire Safety Concepts Tree, provides a starting point for considering the performance of a water based fire suppression system. Considering fire protection objectives for water based fire suppression systems, means of evaluating system reliability can be developed. This development requires identification of system components that are significant to the overall system reliability.

  • PDF

On the Consideration of CO and Soot Yield Concept in FDS Fire Field Model (FDS 화재해석 모델에 적용된 CO와 연기 생성율 개념에 대한 고찰)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.93-99
    • /
    • 2009
  • 본 연구는 ISO-9705 표준화재실의 40% 축소모형실험 결과와 FDS 화재해석 결과의 비교분석을 통하여 FDS 화재해석 모델에 적용된 CO 와 soot의 생성율(yield rate)에 기초한 접근방식의 타당성을 검토한다. 일반적으로 생성율은 연료적인 특성인 동시에 공간의 환기조건이나 열적조건등에 영향을 받게 된다. 그러나 FDS 해석에 적용되는 연료의 생성율은 환기량이 충분한 상태(well ventilated condition)에서 측정되어진 물성으로써 공간내부의 CO와 soot 농도는 연료의 종류와 화원의 크기에 의해서만 결정된다. 따라서 환기조건과 연료특성에 따른 화재공간 내부에서의 CO와 soot 농도를 측정하여 이 결과를 FDS 시뮬레이션 결과와 직접 비교함으로써 환기조건 및 연료종류에 따른 CO 와 soot의 생성율 개념의 타당성을 고찰해보고자 한다.

  • PDF

Evaluation of the Prediction Performance of FDS Combustion Models for the CO Concentration of Gas Fires in a Compartment (구획실 내 가스연료 화재의 CO 농도에 대한 FDS 연소모델의 예측성능 평가)

  • Baek, Bitna;Oh, Chang Bo;Hwang, Chel-Hong;Yun, Hong-Seok
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The prediction performance of combustion models in the Fire Dynamics Simulator (FDS) were evaluated by comparing with experiment for compartment propane gas fires. The mixture fraction model in the FDS v5.5.3 and Eddy Dissipation Concept (EDC) model in the FDS v6.6.3 were adopted in the simulations. Four chemical reaction mechanisms, such as 1-step Mixing Controlled, 2-step Mixing Controlled, 3-step Mixing Controlled and 3-step Mixed (Mixing Controlled + finite chemical reactions) reactions, were implemented in the EDC model. The simulation results with each combustion model showed similar level for the temperature inside the compartment. The prediction performance of FDS with each combustion model showed significant differences for the CO concentration while no distinguished differences were identified for the $O_2$ and $CO_2$ concentrations. The EDC 3-step Mixing Controlled largely over-predicted the CO concentration obtained by experiment and the mixture fraction model under-predicted the experiment slightly. The EDC 3-step Mixed showed the best prediction performance for the CO concentration and the EDC 2-step Mixing Controlled also predicted the CO concentration reasonably. The EDC 1-step Mixing Controlled significantly under-predict the experimental CO concentration when the previously suggested CO yield was adopted. The FDS simulation with the EDC 1-step Mixing Controlled showed difficulties in predicting the $CO_2$ concentration when the CO yield was modified to predict the CO concentration reasonably.

Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room (반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The objective of this study is to evaluate the prediction accuracy of FDS(Fire Dynamic Simulator) for the thermal and chemical characteristics of under-ventilated fire with unsteady fire growth in a semi-closed compartment. To this end, a standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time (until maximum 2.0 MW based on ideal heat release rate) using a spray nozzle located at the center of enclosure. To verify the capability of FDS, the predicted results were compared with a previous experimental data under the identical fire conditions. It was observed that with an appropriate grid system, the numerically predicted temperature and heat flux inside the compartment showed reasonable agreement with the experimental data. On the other hand, there were considerable limitations to predict accurately the unsteady behaviors of CO and $CO_2$ concentration under the condition of continuous fire growth. These results leaded to a discrepancy between the present evaluation of FDS and the previous evaluation conducted for steady-state under-ventilated fires. It was important to note that the prediction of transient CO production characteristics using FDS was approached carefully for the under-ventilated fire in a semi-closed compartment.

The performance analysis and design verification about the fire control system using Modeling and Simulation (M&S를 이용한 사격통제 시스템의 설계검증 및 성능분석에 관한 연구)

  • Yun, Dong Sik;Kim, Chon Hwan;Lim, Young Taek;Bae, Yoon Ji
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Gun fire solution computed in ballistic computing unit (BCU) needs to evaluated before applying in real fire. In this paper, ballistic performance analysis method is studied for reasonable prediction or hit probability with ballistics error presentation on hitting plane. Also Gun fire solution using interacting multiple model (IMM) algorithm is analyzed through proposed method.

  • PDF

A Study on the Fire Safety Management measures from during a fire toxic gases generated (Focus to Co gas measures) (화재시 생성된 유독가스로부터의 소방 안전관리 방안 연구(Co 가스 대책을 중심으로))

  • Kim, Byeong-Seok;Jang, Byeong-Jip;Choe, Man-Cheol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.55-66
    • /
    • 2011
  • Recently developed a variety of architectural interior decoration according hwadoeme type of toxic gases generated during fire also are becoming diversified, resulting in fatal casualties occurred in the trend is also being increased. During a fire, toxic gas that is generated varies depending on the combustible material occurs. However, all combustible materials, including carbon, incomplete combustion of carbon monoxide which is generated in the most common toxic gases can be seen as one. Accordingly, in this study of organic solids that are generated in case of fire toxic gases, and briefly discuss the characteristics of the risks and, by far the most common Co gas for measures to prevent human casualties, seolbijeok, the temperature dependence, divided into four aspects of administrative daechaekdeung explained.

  • PDF

Study of the Real Condition and Improvement Plans of a Fire Protection System Installed at Museum Storage (수장고에 설치된 소방시설의 실태 및 개선방안에 관한 연구)

  • Park, Jong-A;Joo, Seung-Ho;Kang, Eun-Soo;Lee, Dae-Keon
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.60-66
    • /
    • 2018
  • Museum storage has been a unique area for experts, such as curators and managers etc., is a part that requires attention among the recent changes in museums because of changes to a type that is being opened gradually to visitors. On the other hand, there is an increased the risk of a fire according to negligence etc. of visitors. Hence, appropriate measures for a fire protection system to respond to varying museum storage are required. This study examined the status of fire protection systems applied to museum storage visiting 40 domestic public museums with the support of the Ministry of Culture, Sports and Tourism, and a direction to install a fire protection system was presented by drawing cases of fire protection systems with less adaptability or poor management or excellent fire protection systems, and a direction for improvement was presented.

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

The Characteristics of $CO_2 $ Extinguishant Transfer According to the Nozzle Conditions of a Fixed Eire System (고정식 소화장치 노즐조건에 따른 $CO_2 $전달특성)

  • 박찬수;최주석;전철균
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.41-48
    • /
    • 2004
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the characteristics of $CO_2 $;, extinguishant transfer by varying the location of the injection nozzle, which affects the effect of a $CO_2 $;, fire fighting system used in the form of fixed systems for the marine engine room. Flow fields and $CO_2 $;, concentration fields were measured according to the location of the injection nozzle. In the case of arranging the injection nozzle on the center of the ceiling, the low-normal concentration distribution was developed along the $CO_2 $;, jet due to the downward flow created by impinging ceiling jets in the symmetric plane. The concentration line reaches its peak due to the mass transfer of $CO_2 $;, at the comer.