• 제목/요약/키워드: Co-current flow

검색결과 257건 처리시간 0.03초

Mo 및 Co계 분말의 용사조건에 따른 기계적 특성 변화 (Variation of Mechanical Properties with Powder Spraying Conditions in Mo and Co Alloy)

  • 하국현
    • 한국분말재료학회지
    • /
    • 제2권3호
    • /
    • pp.201-207
    • /
    • 1995
  • In general, the characteristics of plasma spray coating are strongly dependent on process conditions. In this paper, Mo and Co alloy coating layers were made by plasma spraying with different spray parameters and characterized using X-ray diffraction, scanning electron microscopy(SEM), hardnass test, and wear test. It was found that the coating characteristics were mainly affected by phase composition of the powder, spray distance, arc current, and gas flow rate.

  • PDF

미소 사다리꼴 그루브를 갖는 채널내의 유동에서 기-액의 상호마찰의 영향 (Friction in Micro-Channel Flows of a Liquid and Vapor in Trapezoidal Grooves)

  • 서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.124-129
    • /
    • 2000
  • The flow of liquid and vapor is investigated in trapezoidal grooves. The effect of variable shear stress along the interface of the liquid and vapor is studied for both co-current and counter-current flows. Velocity contours and results fur the friction are obtained for both trapezoidal grooves. An approximate relation that was previously utilized for the friction for the liquid was modified to obtain accurate agreement with the results for trapezoidal grooves.

  • PDF

LCD 소자 최적화의 실험적 고찰 (An Experimental Investigation of LDD Device Optimization)

  • 강대관;김달수;김현철;송낙운
    • 대한전자공학회논문지
    • /
    • 제27권3호
    • /
    • pp.72-78
    • /
    • 1990
  • 본 논문에서는 LDD 소자의 최적화의 물리적 의미를 수치 씨뮬레이션을 통해 다루었으며 관련 실험을 통하여 최적화된 LDD 구조를 해석해 보았다. 첫째, 수치해석에 의하면 최적화 조건시에 드레인 n-영역에서의 전계는 고르며 낮은 분포를 보이고 있고, 전류는 이 영역에서 넓게 퍼져 흘렀다. 아울러 이때 최적점은 모든 공정 및 전기조건을 고려하여 총체적으로 최적화하여 얻어져야함이 발견되었다. 둘째, 실험에 의하면 최적 조건의 경우 기판전류와 드레인 전류비에 의해 n-영역의 최대전계는 극소화되었다. 이때 소자의 수명은 최대가 되었으며 n-영역의 저항은 channel 저항에서 $n^+$ 접합 저항으로 유연하게 변환이 되었다.

  • PDF

원적외선 레이저 펌핑용 가변파장 $CO_2$ 레이저 (Tunable $CO_2$ Laser for FIR Laser Pumping)

  • 진윤식;정기형;이헌주
    • 한국광학회지
    • /
    • 제1권2호
    • /
    • pp.155-161
    • /
    • 1990
  • 메틸알코올 레이저의 여기용으로 저속축류형의 가변파장 $CO_2$ 레이저를 제작하였다. 파장가변은 ZnSe Brewster 창과 반사 회절격자를 사용하였으며, 반사 회절격자는 Blaze wavelength 10.6$\mu\textrm{m}$, 100grooves/mm 인 평면형이다. 실험은 $CO_2$ 레이저의 연속발진 출력특을 살펴보고, $CO_2$ 레이저의 전 발진구간을 파장가변시켜 얻어진 출력분포를 $CO_2$ 레이저의 이득 곡선과 비교하였다. 연속발진 출력은 기체 혼합비 $CO_2: N_2$ : He=1:3:10, 전류 55mA, 압력 14 torr 일 때 100W를 얻었다. 가변된 파장은 10.4$\mu\textrm{m}$ 영역의 R(6)-R(38), P(6)-P(36), 9.4$\mu\textrm{m}$ 영역의 R (10)-R(32), P(10)-P(38)의 약 60여개의 회전선이 발진함을 확인하였고, 이 때의 파장은 9.3295$\mu\textrm{m}$에서 10.7648$\mu\textrm{m}$까지 변화하였다. 각 영역에서 얻어진 출력분포는 $CO_2$ 레이저의 이득곡선과 잘 일치하였고, 최대 출력은 20W 정도였다.

  • PDF

배전운영 시스템에서 상시개방 연계 스위치 투입에 의한 루프 운전 중 구간전압 계산 방법 (Section Voltage Calculation while a Loop Operation by Tie-Switch Close in a Distribution Management System)

  • 서정수;임일형;박종호;신용학;최면송
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.397-403
    • /
    • 2016
  • Generally, an electrical distribution configuration is a radial system with one-way current in a distribution management system (DMS). All feeders in a DMS have tie-switches to make radial system. Sometimes, DMS should change a tie-switch for operation. In that case, the tie-switch has to be closed first; then a switch is opened as another tie-switch in order to prevent blackout for customers. At the moment when the tie-switch is closed, distribution system is operated in a loop state, not radial. Before the loop operation, DMS operator has to check any expected events for stable distribution system operation; and the most important event is a mis-operation of a protection relay. In addition, DMS operator should check voltage profile violation but a calculation method of section voltages had not been used. Thus, this paper proposes a calculation method of section voltages at a loop operation in a DMS. The proposed calculation algorithm is verified by Matlap Simulink.

아크시간이 초고압 가스차단기의 차단성능에 미치는 영향 (Effect of arcing time on the interruption Performance of EHV class GCB)

  • 박경엽;신영준;송기동;정진교;송원표;권기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.161-163
    • /
    • 1998
  • The interruption performance of EHV class gas circuit breakers critically depends on the flow conditions inside interrupter and the external circuit conditions. In case of puffer type gas circuit breakers the flow conditons are significantly influenced by arcing time. In this paper the calculated results of RRRV and pressure rise at current zero with varying arcing time are presented and the effect of arcing time on the thermal interruption performance of EHV class gas circuit breakers is analyzed.

  • PDF

마이크로채널 반응기를 이용한 강화된 저온 피셔-트롭쉬 합성반응의 전산유체역학적 해석 (Intensified Low-Temperature Fischer-Tropsch Synthesis Using Microchannel Reactor Block : A Computational Fluid Dynamics Simulation Study)

  • ;나종걸;박성호;정익환;이용규;한종훈
    • 한국가스학회지
    • /
    • 제21권4호
    • /
    • pp.92-102
    • /
    • 2017
  • 피셔-트롭쉬 합성반응은 CO와 H2의 혼합가스로 이루어진 합성가스를 부가가치가 높은 탄화수소 제품으로 변환시킨다. 본 논문에서는 저온 피셔-트롭쉬 합성반응과 단일, 다중 마이크로채널 반응기에 패킹시킨 촉매를 기반으로 강화된 반응조건의 열전달을 고려하여 전산유체역학 기반의 시뮬레이션을 진행하고 분석하였다. 단일채널모델을 통하여 CO 전환률이 ~65% 이상, $C_{5+}$ 선택도가 ~74% 이상을 달성하면서도 Co 기반의 super-active 촉매를 통해 GHSV를 $30000hr^{-1}$을 달성할 수 있음을 보였다. 다중 마이크로채널 반응기모델에서는 열전달 시뮬레이션을 동시에 해석하여, 3가지의 다른 반응기구조에 대해서, 직교류 wall boiling 냉매를 사용시 ${\Delta}T_{max}$가 23 K였으며 평행유동 subcooled 냉매와 평행유동 wall boiling 냉매의 경우 각각 15 K와 13 K의 ${\Delta}T_{max}$를 보였다. 반응기 전체적으로 498 - 521 K에서 온도제어가 가능했으며 계산된 사슬성장 가능성은 저온 피셔-트롭쉬 합성에 적합한 것으로 보인다.

분리된 접지망에서 CT 2차회로 고장전류 Flow 특성 (Fault current flow characteristics of CT secondary circuit connected isolated ground meshes)

  • 이상길;김경열;최형주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.772-773
    • /
    • 2011
  • 발전단지내 발전소와 변전소 접지망이 서로 연결되지 않고 독립적으로 구성된 경우 설비보호를 위한 보호회로가 큰 대지전위 차로 인해 손상되거나 보호설비가 오동작할 우려가 있다. 본 논문에서는 독립된 접지망간 연결된 보호회로에 대지전위 차로 인해 발생할 수 있는 문제를 분석하였으며 고장전류가 유입된 접지망 전위가 상승하면 CT(Current Transformer)회로가 이중접지 된 곳에서는 보호회로가 오동작할 수 있는 조건이 형성되고, 이중접지가 안되었다 할지라도 대지전위 상승이 회로를 통해 전달되어 회로와 외함간 절연파괴가 일어날 수 있으므로 보호회로 케이블이 발전소와 변전소간 연결된 곳에서는 반드시 접지망을 연결하여야 한다는 것을 확인할 수 있었다.

  • PDF

사다리꼴 그루브를 갖는 미소 채널 내의 유동에서 기-액의 상호마찰의 영향 (The Influence of Liquid-Vapor Interactions on Friction in Micro-Channel Flow with Trapezoidal Grooves)

  • 서정세
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.12-17
    • /
    • 2002
  • Abstract The flow of liquid and vapor is investigated in trapezoidal grooves. The effect of variable shear stress along the interface of the liquid and vapor is studied for both co-current and counter-current flows. Velocity contours and results for the friction are obtained for both trapezoidal grooves. An approximate relation that was previously utilized for the friction for the liquid was modified to obtain accurate agreement with the results for trapezoidal grooves.

수소/산소/이산화탄소 혼합기의 백금촉매반응특성 : 비균일 반응의 점화 온도 (Heterogeneous Ignition of $H_2/O_2/CO_2$ Mixture Over Platinum Catalyst)

  • 남창호;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.90-96
    • /
    • 2001
  • Catalytic ignition of $H_2/O_2/CO_2$ mixtures over platinum catalyst is experimentally investigated by using microcalorimetry. For comparison, $N_2$ and Ar is also used as diluent gas. The gas mixture flows toward platinum foil heated by electric current at atmosphere pressure and ambient temperature. The ignition temperature range 350-445K according to the fuel ratio, dilution ratio and diluent gas. It increases as the fuel ratio and dilution ratio increase. $H_2/O_2$ mixture with $CO_2$ ignites at higher temperature than with other diluents by 30-50K. Several experimental evidences show the inhibition effects of $CO_2$ in $H_2-O_2$ heterogeneous reaction is considerable

  • PDF