• 제목/요약/키워드: Co-cr alloy

검색결과 302건 처리시간 0.032초

정밀주조 Hastelloy C-276 합금의 미세조직과 기계적 성질에 미치는 W 함량과 열처리의 영향 (Effect of Tungsten Contents and Heat Treatment on the Microstructures and Mechanical Properties of Hastelloy C-276 Alloy Investment Castings)

  • 유병기;박흥일;배차헌;김성규;정해용
    • 한국주조공학회지
    • /
    • 제37권1호
    • /
    • pp.21-29
    • /
    • 2017
  • The effects of W content and heat treatment on the microstructure and mechanical properties of Hastelloy C-276 alloy investment castings were discussed. As the W content was increased, dendritic microstructure was refined and network type precipitate formed during solidification was distributed on the dendritic grain boundaries. Cr, Fe and Mn were highly segregated in the Ni-based dendrite matrix, and Mo, W, C and Si were in the precipitates. Due to the heat treatment, fine granular and flake precipitates were newly formed in the matrix, and unresolved network type precipitates remained on the grain boundary. The network type precipitates and the granular and flake precipitates formed by heat treatment were confirmed to be ${\mu}$ phase intermetallic compounds with similar compositions. Due to the increase of the W content and the heat treatment, hardness and tensile strength were significantly increased. However, tensile strength after aging treatment was decreased with the W content. These results can be explained in that brittle fracturing by the unresolved network type precipitates dispersed in the grain boundary was predominant over ductile fracturing by the dimple ruptures originating from the fine granular precipitates in the matrix.

Seawater ballast tank 환경에서 저합금강의 내식성에 미치는 합금원소의 영향 (Effects of Alloying Elements on Corrosion Resistance of Low Alloyed Steels in a Seawater Ballast Tank Environment)

  • 김동우;김희산
    • 대한금속재료학회지
    • /
    • 제48권6호
    • /
    • pp.523-532
    • /
    • 2010
  • Co-application of organic coating and cathodic protection has not provided enough durability to low-alloyed steels inseawater ballast tank (SBT) environments. An attempt has made to study the effect of alloy elements (Al, Cr, Cu, Mo, Ni, Si, W) on general and localized corrosion resistance of steels as basic research to develop new low-allowed steels resistive to corrosion in SBT environments. For this study, we measured the corrosion rate by the weigh loss method after periodic immersion in synthetic seawater at $60^{\circ}C$, evaluated the localized corrosion resistance by an immersion test in concentrated chloride solution with the critical pH depending on the alloy element (Fe, Cr, Al, Ni), determined the permeability of chloride ion across the rust layer by measuring the membrane potential, and finally, we analyzed the rust layer by EPMA mapping and compared the result with the E-pH diagram calculated in the study. The immersion test of up to 55 days in the synthetic seawater showed that chromium, aluminium, and nickel are beneficial but the other elements are detrimental to corrosion resistance. Among the beneficial elements, chromium and aluminium effectively decreased the corrosion rate of the steels during the initial immersion, while nickel effectively decreased the corrosion rate in a longer than 30-day immersion. The low corrosion rate of Cr- or Al-alloyed steel in the initial period was due to the formation of $Cr_2FeO_4$ or $Al_2FeO_4$, respectively -the predicted oxide in the E-pH diagram- which is known as a more protective oxide than $Fe_3O_4$. The increased corrosion rate of Cr-alloyed steels with alonger than 30-day exposure was due to low localized corrosion resistance, which is explained bythe effect of the alloying element on a critical pH. In the meantime, the low corrosion rate of Ni-alloyed steel with a longer than 30-day exposure wasdue to an Ni enriched layer containing $Fe_2NiO_4$, the predicted oxide in the E-pH diagram. Finally, the measurement of the membrane potential depending on the alloying element showed that a lower permeability of chloride ion does not always result in higher corrosion resistance in seawater.

The High Temperature Oxidation Behavior of Diffusion Aluminized MarM247 Superalloy

  • Matsunaga, Yasuo;Matsuoka, Akira;Nakagawa, Kiyokazu
    • Corrosion Science and Technology
    • /
    • 제2권1호
    • /
    • pp.53-57
    • /
    • 2003
  • The MarM247 based superalloy (8wt.%Cr- 9wt.%Co- 3wt.%Ta- 1.5wt.%Hf- 5.6%wt.Al- 9.5wt.%W- Bal. Ni) specimens were diffusion aluminized by for types of pack cementation methods, and their coating structure and their high temperature oxidation resistance were investigated. The coated specimens treated at 973K in high aluminum concentration pack had a coating layer containing large hafunium rich precipitates, which were originally included in substrate alloy. After the high temperature oxidation test in air containing 30 vol.% $H_2O$ at 1273K ~ 323K, the deep localized corrosion which reached to the substrate were observed along with these hafnium rich precipitates. On the other hand, the coated specimens treated at 1323K using low aluminum concentration pack showed the coating layer without the large hafunium rich precipitates, and after the high temperature oxidation test at 1273K for 1800 ksec, it did not show the deep localized corrosion. The nickel electroplating before the aluminizing forms thick hafnium free area, and its high temperature oxidation resistance were comparable to platinum modified aluminizing coatings at 1273K.

전해질 농도와 식각시간에 따른 비귀금속합금의 표면조도 변화 (EFFECTS OF ELECTROLYTE CONCENTRATION AND ETCHING TIME ON SURFACE ROUGHNESS OF NI-CR-BE ALLOY)

  • 허재웅;전영찬;정창모;임장섭
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.178-190
    • /
    • 2000
  • The purpose of this study was to evaluate the surface roughness of Ni-Cr-Be alloy($Verabond^{(R)}$, Aalba Dent Inc., USA) according to electrolyte concentration and etching time. Total of 150 metal specimens ($12{\times}10{\times}1.5mm$) composed of 5 polisded specimens, 5 sandblasted specimens, 140 etched specimens were prepared. Etched groups were divided into 28 groups by the $HClO_4$ concentrations(10, 30, 50, 70%) and etching times(15, 30, 60, 120, 180, 240, 300 seconds). The mean surface roughness(Ra) and the etching depth were measured with Optical 3-dimensional surface roughness measuring machine(Accura 1500M, Intek Engineering Co., Korea) and observed under SEM. The results obtaind were as follows: 1. Surface roughness(Ra) and etching depth were affected by the order of etching time, electrolyte concentration, and their interaction(P<0.05). 2. Surface roughness(Ra) and etching depth were increased with etching time in 10%, 30% electrolyte concentrations, but they had no significant difference with etching time in 70% (P<0.05). 3. Surface roughness(Ra) and etching depth decreased in the order of 30, 10, 50, 70% electrolyte concentrations from 120 seconds etching time(P<0.05). 4. The remarkable morphologic changes in etched surface were observed along the grain boundaries in 15, 30 seconds of 10%, 30% concentrations and the morphologic changes could be denoted in the grains themselves as well as along the boundaries with the lapse of time. Even though the noticeable morphologic changes also took place in etched surface with 50% concentration, the degree of changes were less than that of changes with 10%, 30%. However, there were little morphologic changes with 70% concentration regardless of etching time. 5. Surface roughness(Ra) of sandblasting group with $50{\mu}m\;Al_2O_3$ had no significant difference with 30%-30 seconds etched group(P<0.05).

  • PDF

Incoloy 909 합금의 최적 알루미나이징 확산 코팅 (Optimal Aluminizing Coating on Incoloy 909)

  • 권순우;윤재홍;주윤곤;조동율;안진성;박봉규
    • 한국표면공학회지
    • /
    • 제40권4호
    • /
    • pp.175-179
    • /
    • 2007
  • An Fe-Ni-Co based superalloy Incoloy 909 (Incoloy 909) has been used for gas turbine engine component material. This alloy is susceptible to high temperature oxidation and corrosion because of the absence of corrosion resistant Cr. For the improvement of durability of the component of Incoloy 909 aluminizing-chromate coating by pack cementation process has been investigated at relatively low temperature of about $550^{\circ}C$ to protect the surface microstructure and properties of Incoloy 909 substrate. As a previous study to aluminizing-chromate coating by pack cementation of Incoloy 909, the optimal aluminizing process has been investigated. The size effects of source Al powder and inert filler $Al_O_3$ powder and activator selection have been studied. And the dependence of coating growth rate on aluminizing temperature and time has also been studied. The optimal aluminizing process for the coating growth rate is that the mixing ratio of source Al powder, activator $NH_4Cl$ and filler $Al_O_3$ are 80%, 1% and 19% respectively at aluminizing temperature $552^{\circ}C$ and time 20 hours.

HVOF 용사 코팅 공정 조건에 따른 코팅층의 기공도 예측 (Porosity Prediction of the Coating Layer Based on Process Conditions of HVOF Thermal Spray Coating)

  • 전준협;서남혁;이종재;손승배;이석재
    • 한국분말재료학회지
    • /
    • 제28권6호
    • /
    • pp.478-482
    • /
    • 2021
  • The effect of the process conditions of high-velocity oxygen fuel (HVOF) thermal spray coating on the porosity of the coating layer is investigated. HVOF coating layers are formed by depositing amorphous FeMoCrBC powder. Oxygen pressure varies from 126 to 146 psi and kerosene pressure from 110 to 130 psi. The Microstructural analysis confirms its porosity. Data analysis is performed using experimental data. The oxygen pressure-kerosene pressure ratio is found to be a key contributor to the porosity. An empirical model is proposed using linear regression analysis. The proposed model is then validated using additional test data. We confirm that the oxygen pressure-kerosene pressure ratio exponentially increases porosity. We present a porosity prediction model relationship for the oxygen pressure-kerosene pressure ratio.

지대치삭제의정확도가레이져신터링기술로제작된Co-Cr 코핑의변연적합도에미치는영향 (Influence of the accuracy of abutment tooth preparation on the marginal adaptation of Co-Cr alloy copings fabricated with a selective laser sintering technology)

  • 김서랑;곽재영;허성주;김성균;김명주
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.337-344
    • /
    • 2015
  • 목적: 본 연구의 목적은 지대치 삭제의 정확도와 metal coping의 변연적합도와의 상관관계를 알아보는 데 있다. 이를 통해, 세 가지 다른 제작 방식 (주조, milling, 기법)이 이 상관관계에 미치는 영향을 비교해 보고자 한다. 재료 및 방법: 두 개의 master medel을 서로 다른 방식으로 제작하였다; 첫 번째 모델은 치과의사에 의해 deep chamfer margin을 가지도록 지대치 삭제된 것이고, 두 번째 모델은 3-D designing software program을 이용하여 동일한 삭제원칙에 따라 제작되었다. 각각의 모델에 대하여 세 가지 제작 방식으로 코발트-크롬 코핑을 12개씩 제작하여, 총 72개의 시편을 얻었다. 각 시편을 master model상에 적합시키고 공초점 레이저 주사 현미경으로 변연적합도를 측정하였다. 결과: SLS system (P=.0231)과 주조방식(P<.0001)에서는 computer designed model이 hand prepared model에 비하여 유의하게 우수한 변연적합도를 보였다. 그러나 milling group에서는 두 모델 간에 유의한 차이를 나타내지 않았다(P=.9962). 결론: 본 연구에 한하여, 지대치 삭제의 정확도가 금속 코핑의 변연적합도에 미치는 영향은 그 제작 방식에 따라 달랐다. 제작 방식에 따른 변연적 합도는 SLS system이 가장 우수하였고 지대치 삭제의 정확도에 의해 영향을 받았다. 한편, milling 방식은 세 가지 방식 중 가장 큰 변연 격차를 나타내었으며 지대치 삭제의 정확도에 영향을 받지 않았다.

Coping design에 따른 도재전장관의 파절강도에 관한 연구 (THE FRACTURE RESISTANCE OF CERAMOMETAL CROWN WITH VARIOUS COPING DESIGN)

  • 정완모;동진근;진태호
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.125-132
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of the metal coping design on the fracture resistance of ceramometal crown. The Ni-Cr alloy(Supranium, Krupp Co., German) and Vaccm-fired porcelain powder(Vita VMK 689, Vita Co., Germany) were used in this study. The measurement of fracture resisitance of ceramometal crown was done with Instron Universial Testing Machine(Instro Co., Model no.4201). The obained results were as fellows : 1. The fracture resistance measured at the buccal cusp tip was the highest value in the group that those position of ceramometal junction was 2mm superior to the lingual finshing margin(100.25Kg) and the fracture resistance revealed on order of the group that those position was 2mm buccal to the central groove(51.64Kg). 2. The fracture resistance measured at the central groove was higher value in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm superior to lingual finishing margin(132.48Kg). 3. In all cases, the fracture resistance at the central groove was higher than that at the buccal cusp tip.

  • PDF

초고속 스핀들의 내구성 향상을 위한 WC-Co 분말의 HVOF 용사 코팅 (HVOF Thermal Spray Coating of WC-Co for Durability Improvement of High Speed Spindle)

  • 김길수;백남기;윤재홍;조동율;윤석조;오상균;황순영;천희곤
    • 한국표면공학회지
    • /
    • 제39권4호
    • /
    • pp.179-189
    • /
    • 2006
  • High velocity oxygen fuel(HVOF) thermal spray coating of WC-Co powder is one of the most promising candidate for the replacement of the traditional hard chrome plating and ceramics coating because of the environmental problem of the very toxic $Cr^{6+}$ known as carcinogen and the brittleness of ceramics coating. WC-Co micron and nano powder were coated by HVOF thermal spraying method for the study of durability improvement of the high speed spindle. Coatings were planned by Taguchi program for the four spray parameters of spray distance, flow rates of hydrogen, oxygen and powder feed rate. Optimal coating process was obtained by the studies of coating properties such as porosity, surface roughness, micro hardness, and micro structure. WC-Co micron and nano powder were coated on the Inconel 718 substrate by the optimal coating process obtained in this study. The wear behaviors were studied by the sliding wear tester at room temperature and at an elevated temperature of $500^{\circ}C$ for the application to high speed spindle. Sliding wear test was carried out for four most promising hard coatings of chrome coating, ceramics coatings such as $A1_2O_3,\;Cr_2O_3$ and HVOF Co-alloy T800 for the comparison of their wear behaviors. HVOF WC-Co coating was better than other coatings showing highest micro hardness of 1400 Hv and comparable friction coefficients with others. HVOF WC-Co coating is a strong candidate for the replacement of the traditional hard chrome plating for the high speed spindle.

원자흡수법을 이용한 다원소 동시 분석 실험 조건에 관한 기초 특성 연구 (Characterization and Studies of Compromised Experimental Conditions for the Simultaneous Multielemental Analysis by Flame Atomic Absorption Spectrometry)

  • 최성규;이현주;박양순;김효진
    • 약학회지
    • /
    • 제39권2호
    • /
    • pp.148-152
    • /
    • 1995
  • For comparison between the compromised experimental condition and the best conditions for each element by flame atomic absorption spectrometer, the absorbances were measured with changing the burner height and HCL current. The optimum absorbance for simultaneous analysis of 6 elements was observed at 1 mA of HCL current and at 4 mm of burner height except Cr and Co. The stability of flame atomic absorption spectrometer on each element was found to be better than 5%. To investigated the accuracy of this instrument, POSCO RM-07 as a real sample was analysed at these compromised experimental conditions and found to be better than 0.04%.

  • PDF