• Title/Summary/Keyword: Co-contamination

Search Result 447, Processing Time 0.029 seconds

Development of Regenerative Braking Control Algorithm for In-wheel Motor Type Fuel Cell Electric Vehicles Considering Vehicle Stability (차량 안정성을 고려한 인휠모터 방식 연료전지 전기자동차용 회생제동 알고리즘 개발)

  • Yang, D.H.;Park, J.H.;Hwang, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.2
    • /
    • pp.7-12
    • /
    • 2010
  • In these days, the researches about hybrid and fuel cell electric vehicles are actively performed due to the environmental contamination and resource exhaust. Specially, the technology of regenerative braking, converting heat energy to electric energy, is one of the most effective technologies to improve fuel economy. This paper developed a regenerative braking control algorithm that is considered vehicle stability. The vehicle has a inline motor at front drive shaft and has a EHB(Electo-hydraulic Brake) system. The control logic and regenerative braking control algorithm are analyzed by MATLAB/Simulink. The vehicle model is carried out by CarSim and the driving simulation is performed by using co-simulation of CarSim and MATLAB/Simulink. From the simulation results, a regenerative braking control algorithm is verified to improve the vehicle stability as well as fuel economy.

  • PDF

Development of an Ultraviolet Raman Spectrometer for Standoff Detection of Chemicals

  • Ha, Yeon Chul;Lee, Jae Hwan;Koh, Young Jin;Lee, Seo Kyung;Kim, Yun Ki
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.247-251
    • /
    • 2017
  • In this study, an ultraviolet Raman spectrometer was designed and fabricated to detect chemical contamination on the ground. The region of the Raman spectrum that indicated the characteristics of the chemicals was $350-3800cm^{-1}$. To fabricate a Raman spectrometer operating in this range, the layout and angle of optical components of the spectrometer were designed using a grating equation. Experimental devices were configured to measure the Raman spectra of chemicals based on the fabricated Raman spectrometer. The wavenumber of the spectrometer was calibrated by measuring the Raman spectrum of polytetrafluoroethylene, $O_2$, and $N_2$. The spectral range of the spectrometer was measured to be 23.46 nm ($3442cm^{-1}$) with a resolution of 0.195 nm ($30.3cm^{-1}$) at 253.65 nm. After calibration, the main Raman peaks of cyclohexane, methanol, and acetonitrile were found to be similar to the references within a relative error of 0.55%.

Decontamination of Duct Waste Arising from the Decommissioning of TRIGA Research Reactor (TRIGA 연구로 해체 시 발생하는 덕트 폐기물의 제염)

  • 최왕규;이근우;정경환;오원진;박진호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.720-724
    • /
    • 2003
  • In order to develop the decontamination process for self-disposal with authorization of duct waste generated from the decommissioning of retired TRIGA research reactors, the surface characterization of duct specimen taken from TRIGA research reactor was carried out and the adequate decontamination method was selected. It can be known that the paint coated internal surface of duct is contaminated with $^{60}Co$and $^{137}Cs$, which are penetrated into the paint layer and incorporated into zinc plated surface of galvanized iron as the material of duct. Two step chemical decontamination process, in which sodium hydroxide and sulfuric acid solutions are used in turn, is quite successful to remove the surface contamination of duct waste.

  • PDF

Characteristics of Machined Surface Roughness and Surface Layers of WC-Co Tools with Plasma Source Ion Implantation (WC-Co 공구의 이온 주입에 따른 표면층 및 가공된 표면거칠기 특성)

  • Kang, Seong-Ki;Kim, Yung-Kyu;Wang, Duck-Hyun;Chun, Young-Rok;Kim, Won-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.106-113
    • /
    • 2010
  • The most suitable condition for plasma source ion implantation(PSII) was found based on the study of the characteristics of PSIIed tool and machined surfaces. The depth analysis according to the chemical bonding state of elements and surface component elements through the XPS and SIMS, was conducted to find the improved property of the PSIIed surface. Due to the diffusion of PSII, the nitrogen was found up to a depth of about 150nm according to the supplied voltage and ion implanted time. The deep diffusion by nitrogen caused the surface modification, but the formation of oxide component was found due to the residual gas contamination on the surface. Statistical method of ANOVA was conducted to find the effects of spindle speed and feed rate in interaction for machined surface roughness with PSIIed tools. The surface modification was found largely occurred by the nitrogen implanted surface with 2 hours for 27kV, 35kV and 43kV.

Performance of Polymer Suspension Insulator with Shed Profile (갓 형상에 따른 폴리머 현수애자의 열화특성)

  • Cho, H.G.;Lee, U.Y.;Kang, S.H.;Lim, K.J.;Yeo, H.G.;Ji, W.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.539-542
    • /
    • 2003
  • Recently, the polymer insulators which are being used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination which lead to the well known phenomenon of dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the aging property of polymer insulator with shed shape(regular, alternative type) is analyzed through numerical analysis, CEA(canadian electricity association) tracking wheel test and IEC 61109 Annex C.

  • PDF

Microbiological Qualities and Post-Pasteurization Contaminations of UHT Milk Produced in Korea (한국에서 생산되는 UHT 우유의 살균 후 오염과 미생물학적 품질)

  • Park, Seung-Young;Park, Jung-Min;Yang, Jin-Oh;Jung, Hoo-Kil;Chun, Ho-Nam;Lee, Byong-Hoon
    • Journal of Dairy Science and Biotechnology
    • /
    • v.24 no.1
    • /
    • pp.9-18
    • /
    • 2006
  • Total 150 packs of UHT milk and UHT-ESL milk, produced by different domestic milk companies, were compared at refrigerated and room temperature for 35 days in terms of microbiological qualities such as incidence date, number of incidence packs, and numbers of bacteria, and post-pasteurization contamination. Overall qualities of UHT-ESL milk were slightly better than that of UHT milk in relations to total bacteria in milk. No coliforms were detected in two groups of UHT milk samples after 35 days. Aerobic spores were more common in two brands of UHT milks stored in 20$^{\circ}$C than those in 7$^{\circ}$C, in which spores were broken out at 7 and 14 day. No incidences of thermoduric bacteria were founded until 14 days in two groups of UHT milks, but high level of counts (<300${\sim}$<3,000 CFU/ml) after 21 days at 20$^{\circ}$C and 40${\sim}$3,600 CFU/ml at 7$^{\circ}$C were detected, respectively. Psychrotrophic bacteria were higher in UHT milk than in UHT-ESL milk, in which began to detect at 28 days. No post-pasteurization contamination by salmonella spp. and staphylococcus aureus were found throughout the experimental periods. One may conclude that the shelf life of UHT milk under cold-chains system can be extended up to 21days, as long as UHT treated milk are filled in sterilized containers by aseptic packaging system.

  • PDF

Development of a Pre-treating Equipment and the Carcass Disposal System for Infected Poultry (감염가금 전처리 및 폐사가축 처리시스템 개발)

  • Hong, J.T.;Kim, H.J.;Yu, B.K.;Lee, S.H.;Hyun, C.S.;Ryu, I.S.;Oh, K.Y.;Kim, S.;Kwon, J.H.;Tack, D.S.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • When we bury the infected poultry into the ground, we have many problems such as the difficulty of making sufficient area for burying, environmental contamination by the leachate, unpleasant ordor. Also, in case of burning the carcass of the infected poultry, there are some problems such as high cost, dust, unpleasant odor, etc. It could cause environmental contamination which many peoples and environmental organization complains about. In this study, we develop a treating system which treats the infected poultry carcass in a environmental method preventing the environment contamination. This system is composed of many processes. The euthanasia system uses rigid vinyl to trap and to do a euthanasia the infected poultry with lethal gas, carbon dioxide. And then, with the tractor attached grappler infected poultry carcass could be put into the carcass treating system. The euthanasia system uses rigid vinyl to trap the infected birds and to confine lethal gas, carbon dioxide. Infected poultry carcass are moved to carcass disposal system by collecting device which is attached at tractor. The carcass treatment system (capacity of disposal : 6.3 $m^3$) is installed on a truck and do one pass work, which is input, crush, stir, sterilize, and discharge treated carcass. 1,000 chickens was killed within 9.7min by $CO_2$ (300L/min) in the tent (10 $m^3$). The collecting device could carry 142 chickens at a time, and the movable carcass treatment system could sterilize 2 tons carcass per hour (at one time). This treatment systems was eco-friendly because it reduced the volume of carcass by 31.9% with no wastewater generation.

Effect of Carbon Dioxide in Fuel on the Performance of PEMFC (연료중의 이산화탄소 불순물에 의한 고분자전해질연료전지의 성능변화 연구)

  • Seo, Jung-Geun;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.42-46
    • /
    • 2008
  • Even though fuel cell have high efficiency when pure hydrogen from gas tank is used as a fuel source, it is more beneficial to generate hydrogen from city gas (mainly methane) in residential application such as domestic or office environments. Thus hydrogen is generated by reforming process using hydrocarbon. Unfortunately, the reforming process for hydrogen production is accompanied with unavoidable impurities. Impurities such as CO, $CO_2$, $H_2S$, $NH_3$, $CH_4$, and $CH_4$ in hydrogen could cause negative effects on fuel cell performance. Those effects are kinetic losses due to poisoning of the electrode catalysts, ohmic losses due to proton conductivity reduction including membrane and catalyst ionomer layers, and mass transport losses due to degrading catalyst layer structure and hydrophobic property. Hydrogen produced from reformer eventually contains around 73% of $H_2$, 20% or less of $CO_2$, 5.8% of less of $N_2$, or 2% less of $CH_4$, and 10ppm or less of CO. This study is aimed at investigating the effect of carbon dioxide on fuel cell performance. The performance of PEM fuel cell was investigated using current vs. potential experiment, long run(10 hr) test, and electrochemical impedance measurement when the concentrations of carbon dioxide were 10%, 20% and 30%. Also, the concentration of impurity supplied to the fuel cell was verified by gas chromatography(GC).

Development of V-SAM Process and Surface Characterization for Anti-contamination of CMP Conditioner (CMP Conditioner의 오염방지를 위한 V-SAM 공정개발과 박막특성 분석)

  • Kim, Dong-Chan;Kim, In-Kwon;Kim, Jeong;Chun, Jong-Sun;Park, Mun-Seak;Park, Jin-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.56-56
    • /
    • 2009
  • 반도체 device가 점점 고집적화, 다층화 되면서 막질의 평탄화를 위한 CMP (chemical mechanical planarization) 공정은 반도체 제작 공정에서 필수 요건이 되었다. 특히 pad conditioning은 CMP 공정 중, 막질의 제거율과 균일도를 유지시키기 위한 중요한 공정이다. 하지만, conditioner를 장시간 사용할 경우 slurry residue와 같은 잔류 오염물질들이 conditioner의 표면의 오염을 유발할 수 있고 이로 인해 conditioner의 수명이 단축되거나 웨이퍼 표면에 결함을 유발할 수도 있다. 본 연구에서는 이를 방지하기 위해 vapor SAM을 이용하여 Ni conditioner 표면에 소수성 박막을 증착하여 오염여부를 평가해 보았다. 먼저, Ni wafer를 이용하여 증착 온도와 압력에 따라 소수성 박막을 증착하여 표면특성을 평가해 보았다. 증착전과 후에 Ni wafer 표면의 접촉각은 contact angle analyzer (Phoenix 400, SEO, Korea)를 이용하여 측정하였다. 박막 표면 형상과 거칠기는 AFM (XE-100, PSIA, Korea)를 이용하여 평가되었고 묘면 성분 분석을 위해 FT-IR (Nicolet 6700, Thermo Scientific, USA)이 사용되었다. SEM (S-4800, Hitach, Japan)은 박막 증착 전과 후의 conditioner를 이용하여 실제 conditioning후 conditioner 표면의 particle 오염정도를 관찰하기 위해 사용되었다. 또한, conditioner 표면에 실제 오염되어있는 particle 개수를 평가하기 위해 particle size analyzer (Accusizer 780A, Particle Sizing Systems Co., USA)을 사용하였다. 본 실험을 통해 최적 증착 조건을 확립하였으며 실제 conditioner 표면에 소수성 박막을 증착 후 $100^{\circ}$ 이상의 높은 contact angle을 확인할 수 있었다. 또한, 소수성 박막이 증착된 conditioner의 경우 실제 conditioning후 표면 particle 오염이 현저히 감소되었음을 확인할 수 있었다.

  • PDF

Assesment of Indoor Air Quality within Public Transport Vehicles operating in specified locations throughout Seoul (서울 일부 지역 교통수단의 실내 공기질 평가)

  • Sohn Jong-Ryeul;Choi Dal-Woong;Choi Jung-Sook;Woo Wan-Gi
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.12-20
    • /
    • 2006
  • This paper was conducted concerning the degree of indoor air quality in public transport vehicles such as taxicabs, buses and subway trains, as sampled through the active participation of drivers and passengers in Seoul between 13th August 2005 and 2nd November 2005. The results were summarized as follows: 1. Among the measured substances especially respirable particulate matters ($PM_{10}$), total bacteria counts (TBC) and carbon dioxide ($CO_2$) exceeded the standard level of $150{\mu}g/m^3,\;800CFU/m^3$ and 1000ppm. 2. The concentration of carbon dioxide ($CO_2$) in taxi recorded 2491ppm, which is more than the standard amount of 1000ppm. This level was comparatively higher than all other public transportation methods. Total bacteria counts (TBC) in bus and subway recorded $1082CFU/m^3\;and\;1856CFU/m^3$, respectively. 3. The drivers who regularly work long hours showed the higher concern about contamination of the air inside the public transport vehicles and they considered it to be worse than the air outside. In contrast, the general public showed less concern about the air quality inside the public transport vehicles. However, they too acknowledged that the quality of the air inside the public transport vehicles was poor. In regards to the degree of indoor air quality in the public transport vehicles, a counterplan must be implemented urgently to effectively combat the excessive levels of $PM_{10}$, microorganism and $CO_2$. We need to gather more conclusive evidence pertaining to other possible contaminants and influencing factors.