• 제목/요약/키워드: Co-contamination

검색결과 451건 처리시간 0.032초

Adsorption properties of MgO protective layer in AC PDP

  • Manakhov, Anton;Nikishin, Nikolay;Hur, Min;Heo, Eun--Gi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.384-387
    • /
    • 2008
  • We have studied the adsorption of contaminations on the MgO protective layer by Thermal Desorption Spectrometry (TDS). The result shows that the increase in exposure time, MgO thickness and humidity multiply the quantity of adsorbed contaminations. It is also found that the desorption activation energy and contamination quantity is decreased by the additional firing process of MgO layer under oxygen environment.

  • PDF

일개 고등학교 환경에서 메치실린 내성 포도알균의 오염도 조사 (Study on the Contamination of Methicillin-Resistant Staphylococcus (MRS) in a High School Environment)

  • 홍승복;백윤희
    • 대한임상검사과학회지
    • /
    • 제49권4호
    • /
    • pp.420-426
    • /
    • 2017
  • 메치실린 내성 포도알균(methicillin resistant Staphylococci, MRS)는 인체 여러 부위에서 집락화 될 수 있으며 의료기관과 연관된 사람에서 흔히 분리된다. 이 연구는 밀접한 단체생활을 하는 일개 고등학교 한 개 반의 학생들 손과 그들이 사용하는 책상에서 MRS 균의 오염 정도를 평가하고자 하였다. Staphylococcus aureus가 28명의 학생의 손 중에서 2 균주가 분리되었으며 모두 메치실린에 감수성이었다. 응고인자 음성 포도알균(coagulase negative Staphylococci, CoNS)는 26 균주가(26/28, 92.9%) 분리되었으며 이들 균주 중 14 균주는 메치실린 내성균(MRCoNS)이었다. 14 MRCoNS 중 S. warneri가 가장 흔하였으며(8/14, 57%), 이들은 대부분의 $non-{\beta}-lactam$ 항생제에 감수성 이었다. 31개의 책상에서는 S. aureus는 분리되지 않았으나 26 CoNS (26/31, 83.9%)가 분리되었다. 손과 책상에서 분리된 포도알균 이외의 균은 Micrococcus와 Bacillus spp.이었다. 결론적으로 MRSA는 이번 연구에서 분리되지 않았으나 mecA 유전자를 갖고 있는 MRCoNS는 학생들의 손에서 높은 비율로 분리되었다. 손씻기와 같은 예방 교육을 강화할 뿐만 아니라 이들 균의 오염 및 보균율 등의 조사와 같은 능동적 감시 등이 이들 균의 감염예방과 전파 차단을 위해 필요할 것으로 사료된다.

유리섬유가 충진된 PTFE 절연재를 채용한 이상용 절연구분장치 개발 (Development of Enhanced Insulator for Section Insulator)

  • 조호령;주종민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2173-2174
    • /
    • 2011
  • At the moment, the section insulators for different phases used for over head contact wire system has been all imported since its first application. However, because the section insulators need frequent maintenance and replacement due to the wear by the friction with pantograph and the contamination, which causes its life shorter than as expected, it is required to develop the insulation material with better wear-resistance characteristics and contamination-resistance characteristics. In this thesis, the author developed the section insulator which adopts Teflon tube insulation material which is composed of the Teflon material with the excellent electrical characteristics and wear-resistance characteristics for a longer expected life than that made of conventional FRP.

  • PDF

원자력 발전소 손발오염 검사장비 설계 (Design of Hand and Foot Radiation Contamination Monitor in Nuclear Power Plant)

  • 박종범;윤기갑;김중선;손창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2828-2830
    • /
    • 2000
  • When changing old parts of the System or establishing new system of the Nuclear power plane it's contribution that given effective economics and learning radiation detector and protect contamination for human, It will be contributed to minimizing pollution of employee for radioactivity as spread of supply with the products in cheaper price then foreign products in new or existing N.P.P.

  • PDF

방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작 (Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent)

  • 김정호;박혜민;주관식
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가 (An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms)

  • 김기철;송근수;김형태;유경훈;신대건;박덕준
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

대도시 지표수와 퇴적물의 환경지구화학적 특성: 중금속 및 VOCs 오염 (Environmental Geochemical characteristics of urban runoff and sediments from gully pot along the main roads in urban area: Heavy metals and VOCs contamination)

  • 이평구;박성원;전치완;신성천
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.129-135
    • /
    • 2000
  • Four types of land use were selected for sampling and study with different characteristics of heavy metal contamination during the period from August 1998 to June 2000. A series of studies have been carried out concerning the physicochemical characteristics of the sediments settling down in a gully pot to evaluate the contamination of Pb, Zn, Cd, Co, Cr and Cu. An examination of six elements indicated that Zn, Cu and Pb were the heavy metals severely impacted by anthropogenic input in Seoul. An assessment of 60 volatile organic compounds (VOCs) in urban runoff and ground water was conducted based on samples collected from 31 sites and 12 wells, respectively, in Seoul City. The higher levels of alkyl benzenes in urban runoff indicated that Seoul areas were mainly contaminated through traffic sources.

  • PDF

이송 중 액체오염 검출센서 개발에 관한 연구 (Study on the Sensor Development for Liquid Contamination during Delivery)

  • 정이하;김병한;홍주표
    • 반도체디스플레이기술학회지
    • /
    • 제15권2호
    • /
    • pp.70-73
    • /
    • 2016
  • Previously proposed contamination detecting sensor was revisited for the investigation of the liquid tendency. Experiments revealed different output voltages for several kinds of liquid input, but showed same values for various flow rates of each liquid. The transmittance of the liquid was measured, and it is well correlated with the voltages. Linearity in values and the compensation of the sensor to sensor deviation were tried to obtain. And, long term test was performed as attached at the manufacturing equipment in the field.

국내산 생강 및 생강가루의 Beauvericin과 Enniatins 오염도 조사 (Survey on Contamination of Beauvericin and Enniatins in Korean Ginger and Ginger Powder)

  • 이미정;임수빈;최정혜;김점순;이데레사;장자영
    • 한국식품위생안전성학회지
    • /
    • 제37권5호
    • /
    • pp.347-355
    • /
    • 2022
  • 본 연구에서는 국내산 생강(n = 43)과 생강가루(n = 31)를 대상으로 beauvericin (BEA)과 enniatins (ENNs)의 오염 실태를 조사하였다. 생강 시료 중 62.79%가 BEA에 오염되었으며, 최대 오염농도는 640.07 ㎍/kg으로 오염률과 오염농도가 조사 대상 독소 중 가장 높았다. 생강에서 ENNs의 오염률은 최대 11.63% (ENB, ENB1)이었으며, 최대 오염농도는 91.02 ㎍/kg (ENA)였다. 생강가루에서는 ENB의 오염률이 70.97%로 가장 높았으나, 오염농도는 BEA이 최대 1, 344.18 ㎍/kg으로 조사 대상 독소 중 가장 높았다. 생강가루의 ENA, ENA1, ENB, ENB1의 오염률은 29.03%, 22.58%, 70.97%, 35.48%였으며, 최대 오염농도는 220.45 ㎍/kg, 156.61 ㎍/kg, 413.99 ㎍/kg, 70.29 ㎍/kg로 ENB의 오염률과 오염농도가 높았다. BEA과 ENNs은 생강보다 생강가루에서 오염농도가 높았다. 생강과 생강가루에서 BEA과 ENNs의 중복 오염률은 각각 16.28%와 64.52%로 생강에 비해 생강가루에서 독소의 중복오염률이 높았다. 본 연구는 한국산 생강과 생강가루의 BEA과 ENNs의 발생 및 이들의 중복 오염을 처음으로 보고하는 것이다.

서울지역 가로수 토양과 은행나무 잎 중의 중금속 원소들의 지구화학적 분산과 오염특성 (Geochemical Dispersion and Contamination Characteristics of Heavy Metals in Soils and Leaves of Ginkgo biloba in Seoul Area)

  • 추미경;김규한;이진수;전효택
    • 자원환경지질
    • /
    • 제38권3호
    • /
    • pp.221-236
    • /
    • 2005
  • 도시화$\cdot$산업화의 인위적 오염원에 의한 중금속 원소들의 분산양상과 오염특성을 파악하기 위하여 서울지역내의 은행나무 잎과 가로수 토양 시료를 채취하여 토양 pH와 Fe, Mn, Pb, Zn, Cu, Cd, Ni, Cr, Co등의 중금속 함량을 측정하였다. 서울지역의 대부분의 토양 pH는 6-9의 범위로 약산성 및 약알칼리성을 보였다. 토양에서 Cd-Co, Cr-Ni, Cu-Zn, Pb-Zn는 높은 상관성을 보이고 있어 Cd은 Co와 배출원이 유사하고, Cr은 Ni과 Zn는 Cu, Pb의 배출원이 유사함을 예측할 수 있었다. 가로수 토양과 은행나무 잎 시료에 대한 원소들의 분포특성은 세척하지 않은 은행나무 잎의 Cd과 Pb, Cu와 Zn의 오염양상이 유사하다. 세척하지 않은 은행나무 잎에서 Cr과 Ni이 유사한 분포패턴을 보였다. 토양에 대해 오염지수에 의하면 공단지역과 교통량 밀집지역에서의 오염도가 높고, 특히 Cd, Cu, Zn에 의한 오염이 심하다. 토양시료에 대한 판별분석결과, 주거지역과 전원지역에서보다 공단지역과 교통량 밀집지역에 부화되는 원소는 Ni> Cr>Pb 순이다. 공단지역과 교통량 밀집지역을 구분하는데 가장 큰 설명력을 가지는 원소는 Cd이며, 교통량 밀집지역에서는 다른 원소에 비해 Co, Pb, Zn가 부화되어 있다.