• Title/Summary/Keyword: Co-contaminants

Search Result 201, Processing Time 0.025 seconds

The Use of Demand Controlled Ventilation in Multi-Purposed Facility (수요기반 환기량 조절법 (DCV)의 다중이용시설 적용방안)

  • Jeong, Jae-Weon;No, Sang-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.111-116
    • /
    • 2008
  • The objective of this paper was to show the possibility of demand-controlled ventilation (DCV) using the current Korean ventilation standard for multi-purposed facilites. Two attractive DCV approaches; $CO_2$-DCV and RFID-DCV were applied to DCV simulations for a theoretical public assembly space served by a dedicated outdoor air system (DOAS) with enthalpy recovery device. A numerical model for predicting realtime occupant number, ventilation rate, and $CO_2$ concentration under given conditions was developed using a commercial equation solver program. It was found that the current ventilation standard causes unstable ventilation system control in DCV applications, especially under $CO_2$-DCV. It is because the ventilation rate (per person) used in Korea is the sum of the outdoor air required to remove or dilute air contaminants generated by both occupant and building itself, and not a pure function of occupant numbers. Finally, it makes DCV control unstable when ventilation flow is regulated only by the number of occupants. In order for solving this problem, current Korean ventilation standard was modified as a form of ASHRAE Standard 62.1-2007 showing good applicability to various DCV approaches. It was found that this modification enhances applicability of the current ventilation standard to DCV significantly.

  • PDF

Cobalt ferrite nanotubes and porous nanorods for dye removal

  • Girgis, E.;Adel, D.;Tharwat, C.;Attallah, O.;Rao, K.V.
    • Advances in nano research
    • /
    • v.3 no.2
    • /
    • pp.111-121
    • /
    • 2015
  • $CoFe_2O_4$ nanotubes and porous nanorods were prepared via a simple one-pot template-free hydrothermal method and were used as an adsorbent for the removal of dye contaminants from water. The properties of the synthesized nanotubes and porous nanorods were characterized by electron diffraction, transmission electron microscopy and x-ray powder diffraction. The Adsorption characteristics of the $CoFe_2O_4$ were examined using polar red dye and the factors affecting adsorption, such as, initial dye concentration, pH and contact time were evaluated. The overall trend followed an increase of the sorption capacity reaching a maximum of 95% dye removal at low pHs of 2-4. An enhancement in the removal efficiency was also noticed upon increasing the contact time between dye molecules and $CoFe_2O_4$ nanoparticles. The final results indicated that the $CoFe_2O_4$ nanotubes and porous nanorods can be considered as an efficient low cost and recyclable adsorbent for dye removal with efficiency 94% for Cobalt ferrite nanotubes and for Cobalt ferrite porous nanorods equals 95%.

Preprocess of GaAs Epitaxial Layer Growth by MBE (MBE에 의한 GaAs 에피층 성장을 위한 사진처리 과정)

  • Kang, Tae Won;Lee, Jae Jin;Hong, Chi You;Kim, Jin Whang;Chung, Kwan Soo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.243-248
    • /
    • 1986
  • The impurities in As and Ga sources and the contamination of the GaAs substrate prior to growing of MBE GaAs epitaxial layer have been investigated using RHEED, AES and RGA methods. The as source was contaminated by H2O, CO, CO2 and AsO, and the Ga source was contaminated by H2, H2O, CO and CO2. These contaminants could easily be removed by prebaking the source. On the other hand, GaAs substrate was contaminated principally carbon and oxygen. The oxygen could easily be removed by heating the substrate above 480\ulcorner, and the carbon could also be reduced by sputtering the substrate with 1ke V Ar+. The chemically etched substrate surface prior to growing the layer was rough, but it was made to be smooth and clean by heating it above 530 \ulcorner.

  • PDF

Measurements and CFD Analysis for Release Rate of CO2 and Characteristics of Natural Ventilation in Lecture Room (강의실 CO2 발생률과 자연환기 특성의 측정 및 CFD 분석)

  • Lee, Donghae;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.1
    • /
    • pp.86-94
    • /
    • 2021
  • Lecture rooms are crowded with many attendees. Moreover, they rely significantly on the natural ventilation through windows for removing and controlling indoor contaminants such as CO2. With the aim of broadening the understanding of the characteristics of natural ventilation phenomena in lecture rooms, the average individual CO2 release rates of attendees were measured during the course of a lecture and compared with previously reported CO2 release rates. In addition, the effects of natural ventilation through windows on the time-variant CO2 concentrations in the center of the lecture room were measured and analyzed. Moreover, details about the overall and regional CO2 concentrations, as well as the air flows in the lecture room, were simulated and analyzed with computational fluid dynamics software, Fluent 2020 R2. It was found that the average individual CO2 release rates were slightly slower than previously reported rates. The local CO2 concentrations in the lecture room for regions with a high density of attendees increased over a short period of time, although the natural ventilation was already started by opening the windows. The overall CO2 concentration in the lecture room rapidly decreased in the early stage of ventilation, but declined very slowly after a longer period of ventilation time. Therefore, in order to enhance the efficiency of a lecture room's natural ventilation, it is recommended to homogeneously distribute the attendees in the lecture room, and to frequently open the windows for short periods of time.

Indoor Air Quality and Human Health Risk Assessment for Un-regulated Small-sized Sensitive Population Facilities (소규모 다중이용시설의 실내공기질 실태조사 및 건강위해성평가: 민감군 이용시설을 중심으로)

  • Shin, Hyejin;Park, Woosang;Kim, Bokyung;Ji, Kyunghee;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.397-407
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate human health risk assessment of indoor air pollutants at small-sized public-use facilities (e.g., daycare centers, hospital and elderly care facilities) that the susceptible population is mainly used. Methods: To assess indoor air quality (IAQ), the concentrations of indoor air contaminants such as HCHO, benzene, toluene, ethylbenzene, xylene, styrene, PM-10, CO, $NO_2$ and $O_3$ in air samples were measured according to the Indoor Air Quality Standard Method. By conducting the questionnaire survey, the major factors influencing IAQ were identified. Human health risk assessment was carried out in the consideration of type of use (user and worker) at 75 daycare centers, 34 hospitals and 40 elderly care facilities. Results: As a result of measurement of indoor air contaminants, the average concentration of HCHO and TVOCs in hospitals was higher than daycare centers and elderly care facilities, about 8.8 and 23.5% of hospitals were exceeded by IAQ standard. In human health risk assessment, for the user of daycare centers and elderly care facilities, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value. Except for HCHO, other values were determined under acceptable risk. Similarly, for the worker of hospitals, the mean carcinogenic risk of HCHO inhalation was higher than acceptable value and other values were evaluated under acceptable risk. In contrast, the risk levels of other contaminants measured in elderly care facilities were acceptable. In the determination of factors influencing IAQ, the construction year, building type, ventilation time, and the use of air cleaner were identified. Conclusions: This study provides the information for establishing the plans of public health management of IAQ at small-sized public-use facilities that have not yet been placed under the regulation. The findings suggest the consideration of human health risk assessment results for the IAQ standards.

Co-contamination of Aflatoxins with Ochratoxin A and Zearalenone in Thuja orientalis Semen

  • Cho, So-Yean;Kang, Shin-Jung;Jung, Joo-Hee;Jeong, Byeong-Ok;Jeong, Choon-Sik
    • Toxicological Research
    • /
    • v.25 no.3
    • /
    • pp.125-131
    • /
    • 2009
  • Korea is representative of a country that consumes herbal medicines; most of the herbal medicines circulating in South Korea have been imported from developing countries in Southeast Asia, such as China and Indonesia. Recently, domestic hygiene and safety are issues that have come to the forefront, because herbal medicines currently in circulation could possibly contain contaminants or residues. Furthermore, the appearance or discovery of harmful new species due to environmental and industrial developments is becoming a social problem. Therefore, it may be necessary to consider and investigate these matters on a continual basis. Recently, mycotoxin contaminations in such foods as cereals, nuts, and powdered red pepper have been reported. They have become a problematic issue; the possibility of contamination in herbal medicines has also been considered. Nevertheless, recognition of and research into mycotoxin contamination in herbal medicines has been scarce because herbal medicine is used in only a few nations. In this research, we identified contamination by aflatoxin which is known to be the most potent mutagenic, carcinogenic, and teratogenic mycotoxin in Thujae Semen, a herbal medicine. We also found co-contaminations involving other mycotoxins, including ochratoxin A and zeraleanone.

CHARACTERIZATION AND STABILIZATION OF WASTE DUSTS FROM SHREDDED AUTOMOBILES INDUSTRIES

  • Takashi, Furuyama;Abel, Bissombolo;Sukeyuki, Mori;Masamichi, Hata;Yoshitsugu, Koga;Tetsuo, Ikejiri
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.699-704
    • /
    • 2001
  • Until recently, disposal to landfill has been the most convenient way to deal with the increasing amount of residues the shredding industries produce. But the shortage of such disposal sites and the risk that liquid drained from these waste dusts may pollute ground water have increased the environmental pressures to find more effective solutions. The present study is an alternative approach that suggests identifying waste dusts characteristics and selecting an appropriate binder for hazardous materials to reduce the amount of contaminants (mainly lead) that were leaking into the soil. Investigations on the characteristics of automobiles waste dusts show that these materials are composed mainly of cottons and sponge like substances, plastics, rubber, glasses and gravel, metals, and electric wires. Besides, the percentage in weight of organic (inflammable) materials is about 70% and the lead contamination, which has not a ionic but a particulate nature, is particularly remarkable in cottons and sponge like materials. Binding additives such as K-20 and sodium carbonate were not effective but the addition of 5 % of cement (in weight of the investigated sample) followed by a 3-minute stirring and a 4-hour storage could drastically reduce the run off of lead below the maximum authorized level. No addition of water was necessary in this method.

  • PDF

Evaluation on Removal of Organics and Nutrients from Reverse Osmosis Concentrate using Activated Carbon (활성탄을 이용한 역삼투 농축수의 유기물 및 영양염류 제거 평가)

  • Joo, Sung Hee;Park, Jong Min;Lee, Yang Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.479-482
    • /
    • 2012
  • Membrane process has been one of the widely applied wastewater treatment options, especially in field. However, one of the tricky issues in the process is to treat concentrates generated from reverse osmosis (RO) system in a manner of saving cost with maximum efficiency for treating a wide range of contaminants. Stimulated with the challenging issues, we have conducted a series of experimental studies in the evaluation for removing organics and nutrients using activated carbon. Results indicated that while powdered activated carbon (PAC) efficiently removed organics and the extent of removal was proportional to the PAC dosage, little removal of nitrogen and phosphorus was observed despite increasing the PAC dose. Interestingly, applying PAC was superior in removing organics than using granular activated carbon (GAC). These results suggest smaller particle size with higher surface area could provide greater chemical reactivity in removing organics.

A Study on Etching of $UO_2$, Co, and Mo Surface with R.F. Plasma Using $CF_4\;and\;O_2$

  • Kim Yong-Soo;Seo Yong-Dae
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.507-514
    • /
    • 2003
  • Recently dry decontamination/surface-cleaning technology using plasma etching has been focused in the nuclear industry. In this study, the applicability of this new dry processing technique are experimentally investigated by examining the etching reaction of $UO_2$, Co, and Mo in r.f. plasma with the etchant gas of $CF_4/O_2$ mixture. $UO_2$ is chosen as a representing material for uranium and TRU (TRans-Uranic) compounds while metallic Co and Mo are selected because they are the principal contaminants in the used metallic nuclear components such as valves and pipes made of stainless steel or inconel. Results show that in all cases maximum etching rate is achieved when the mole fraction of $UO_2\;in\;CF_4/O_2$ mixture gas is $20\%$, regardless of temperature and r.f. power. In case of $UO_2$, the highest etching reaction rate is greater than 1000 monolayers/min. at $370^{\circ}C$ under 150 W r.f. power which is equivalent to $0.4{\mu}m/min$. As for Co, etching reaction begins to take place significantly when the temperature exceeds $350^{\circ}C$. Maximum etching rate achieved at $380^{\circ}C\;is\;0.06{\mu}m/min$. Mo etching reaction takes place vigorously even at relatively low temperature and the reaction rate increases drastically with increasing temperature. Highest etching rate at $380^{\circ}C\;is\;1.9{\mu}m/min$. According to OES (Optical Emission Spectroscopy) and AES (Auger Electron Spectroscopy) analysis, primary reaction seems to be a fluorination reaction, but carbonyl compound formation reaction may assist the dominant reaction, especially in case of Co and Mo. Through this basic study, the feasibility and the applicability of plasma decontamination technique are demonstrated.

SOx and NOx removal performance by a wet-pulse discharge complex system (습식-펄스방전 복합시스템의 황산화물 및 질소산화물 제거성능 특성)

  • Park, Hyunjin;Lee, Whanyoung;Park, Munlye;Noh, Hakjae;You, Junggu;Han, Bangwoo;Hong, Keejung
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.1-13
    • /
    • 2019
  • Current desulfurization and denitrification technologies have reached a considerable level in terms of reduction efficiency. However, when compared with the simultaneous reduction technology, the individual reduction technologies have issues such as economic disadvantages due to the difficulty to scale-up apparatus, secondary pollution from wastewater/waste during the treatment process, requirement of large facilities for post-treatment, and increased installation costs. Therefore, it is necessary to enable practical application of simultaneous SOx and NOx treatment technologies to remove two or more contaminants in one process. The present study analyzes a technology capable of maintaining simultaneous treatment of SOx and NOx even at low temperatures due to the electrochemically generated strong oxidation of the wet-pulse complex system. This system also reduces unreacted residual gas and secondary products through the wet scrubbing process. It addresses common problems of the existing fuel gas treatment methods such as SDR, SCR, and activated carbon adsorption (i.e., low treatment efficiency, expensive maintenance cost, large installation area, and energy loss). Experiments were performed with varying variables such as pulse voltage, reaction temperature, chemicals and additives ratios, liquid/gas ratio, structure of the aeration cleaning nozzle, and gas inlet concentration. The performance of individual and complex processes using the wet-pulse discharge reaction were analyzed and compared.