• Title/Summary/Keyword: Co-22%Cr

Search Result 124, Processing Time 0.025 seconds

The magnetic characteristics of Co-Cr-(Ta) films (Co-Cr-(Ta)박막의 자기특성)

  • Kim, K-H;Jang, K-U;Kim, J-H;S Nakagawa;M Naoe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.242-244
    • /
    • 1996
  • The effects of $Co_{67}$C $r_{33}$ underlayer on the crystallographec and magnetic characteristics of the Co-Cr-Ta layer deposited on the underlayer was investigated. The diffraction intensity $I_{p(002)}$ of Co-Cr-Ta layers on the $Co_{67}$C $r_{33}$ layer was stronger than that of single layer and Co-Cr-Ta/Ti double layer. Therefore, the crystallinity of Co-Cr-Ta layer was improved by the $Co_{67}$C $r_{33}$ underlayers rather than Ti ones. However, the coercivity $H_{c}$ of Co-Cr-Ta layers deposited on $Co_{67}$C $r_{33}$ underlayer was as low as 250 Oe even at substrate temperature of 22$0^{\circ}C$. This $H_{c}$ decrease seems to be attributed to the effect of the $Co_{67}$C $r_{33}$ underlayer as well as interval time between deposition of the underlayer and the Co-Cr-Ta layer.yer.layer.yer.

  • PDF

A Study on the V22Ti16Zr16Ni39X7(X=Cr, Co, Fe, Mn, Al) Metal Hydride Electrodes (V22Ti16Zr16Ni39X7(X=Cr, Co, Fe, Mn, Al) 금속수소화물전극에 관한 연구)

  • Kim, Jeong-Seon;Cho, Won-Il;Cho, Byung-Won;Yun, Kyung-Suk;Kim, Sang-Joo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • Lattice structure, hydrogen absorption characteristics, discharge capacity and cycle life of $V_{22}Ti_{16}Zr_{16}Ni_{39}X_7$(X= Cr, Co, Fe, Mn, Al) alloys were investigated. The matrix phases of these alloys were the C14 Laves phase. Chromium-containing alloy had a vanadium-rich phase in addition to the Laves phase. The chromium, maganese, or aluminum-containing alloys had lower hydrogen equilibrium pressure and larger hydrogen absorption content than the cobalt or iron-containing alloys. The discharge capacities of these alloys were 270~330mAh/g. The discharge capacity according to the alloying element X decreased in the order of Mn>Cr>Co, Al)Fe. The charge/discharge cycle lives of the chromium, cobalt or iron-containing alloys were longer than those of maganese or aluminum-containing alloys due to the lower vanadium dissolution rate.

  • PDF

Sputtering Pressures Dependence on Magnetic Switching Volumes of CoSm/Cr Magnetic Thin Films (스퍼터링 압력에 따른 CoSm/Cr자성 박막의 Magnetic Switching Volumes)

  • 정순영;김성봉
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.232-236
    • /
    • 2000
  • CoSm thin films with a Cr underlayer have received continuous attention as a potential material for a high density longitudinal magnetic recording media. In this study the Ax gas sputtering pressure effects on the magnetic properties of CoSm thin films, which were fabricated by using a dc magnetron sputtering machine, were investigated. The magnetic switching volume is especially important parameter to understand the thermal stability of the written information, magnetization reversal process and media noise. Therefore, in this paper the effects of sputtering pressure on the magnetic switching volume of CoSm thin films grown on Cr underlayer with the same sputtering conditions was studied. As the Ar sputtering pressure during sputtering of the CoSm magnetic layer increases from 5 to 30 mTorr, the measured switching volumes decreased from 9.0 to 5.2$\times$10$^{-18}$ cm$^3$. The calculated diameter of switching unit from V* was less than 22 nm, which satisfies the Sharrock's requirement on the thermal stability of the high density longitudinal magnetic recording media.

  • PDF

Sintering and Electrical Properties According to Sb/Bi Ratio(II) : ZnO-Bi2O3-Sb2O3-Co3O4-Cr2O3 Varistor (Sb/Bi비에 따른 5원계 바리스터의 소결거동 및 전기적 특성(II) : ZnO-Bi2O3-Sb2O3-Co3O4-Cr2O3)

  • Hong, Youn-Woo;Lee, Young-Jin;Kim, Sei-Ki;Kim, Jin-Ho
    • Korean Journal of Materials Research
    • /
    • v.22 no.12
    • /
    • pp.682-688
    • /
    • 2012
  • In this study we aimed to examine the co-doping effects of 1/6 mol% $Co_3O_4$ and 1/4 mol% $Cr_2O_3$ (Co:Cr = 1:1) on the reaction, microstructure, and electrical properties, such as the bulk defects and the grain boundary properties, of ZnO-$Bi_2O_3-Sb_2O_3$ (ZBS; Sb/Bi = 0.5, 1.0, and 2.0) varistors. The sintering and electrical properties of Co,Cr-doped ZBS, ZBS(CoCr) varistors were controlled using the Sb/Bi ratio. Pyrochlore ($Zn_2Bi_3Sb_3O_{14}$), ${\alpha}$-spinel ($Zn_7Sb_2O_{12}$), and ${\delta}-Bi_2O_3$ were formed in all systems. Pyrochlore was decomposed and promoted densification at lower temperature on heating in Sb/Bi = 1.0 by Cr rather than Co. A more homogeneous microstructure was obtained in all systems affected by ${\alpha}$-spinel. In ZBS(CoCr), the varistor characteristics were improved (non-linear coefficient, ${\alpha}$ = 20~63), and seemed to form ${Zn_i}^{{\cdot}{\cdot}}$(0.20 eV) and ${V_o}^{\cdot}$(0.33 eV) as dominant defects. From impedance and modulus spectroscopy, the grain boundaries were found to be composed of an electrically single barrier (0.94~1.1 eV) that is, however, somewhat sensitive to ambient oxygen with temperature. The phase development, densification, and microstructure were controlled by Cr rather than by Co but the electrical and grain boundary properties were controlled by Co rather than by Cr.

Kinetics and Stereochemistry of CO Substitution Reactions of Half-Open Chromocene Carbonyls(Ⅱ) : Reactions of Cp$(\eta^{5}-2,4-Me_{2}C_{5}H_{5})$CrCO and Phosphines

  • Chung, Jong-Jae;Roh, Byung-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.6
    • /
    • pp.669-673
    • /
    • 1993
  • The CO substitution reactions of the complex, $Cp(S-2,4-Me_2C_5H_5)CrCo$ with $PR_3(PR_3=PMePh_2,\;P(OCH_3)_3,\;PMe_2Ph)$ were investigated spectrophotometrically at various temperatures. From the reaction rates, it was suggested that the CO substitution reaction took place by first-order (dissociative) pathway. Activation parameters in decaline were ${\Delta}H^{\neq}\;=\;22.0\;kcal{\cdot}mol^{-1}$, ${\Delta}S^{\neq}=\;-3.8cal{\cdot}mol^{-1}{\cdot}K^{-1}$. Unusually low value of ${\Delta}S{\neq}$ suggests an ${\eta}^5-S{\to}{\eta}^5-U$ conversion of the pentadienyl ligand. This suggestion was confirmed by the Extended-Huckel molecular orbital (EHMO) calculations, which revealed that the total energy of $Cp(S-2,4-Me_2C_5H_5$)CrCO is about 0.42 kcal/mol more lower than that of $Cp(U-2,4-Me_2C_5H_5)CrCO$ and the energy of $[Cp(U-2,4-Me_2C_5H_5)Cr{\cdots}CO]^{\neq} $ transition state is about 2.43 kcal/mol lower than that of $[Cp(S-2,4-Me_2C_5H_5)Cr{\cdots}CO]^{\neq}$ transition state.

22-gauge Co-Cr versus stainless-steel Franseen needles for endoscopic ultrasound-guided tissue acquisition in patients with solid pancreatic lesions

  • Yuki Tanisaka;Masafumi Mizuide;Akashi Fujita;Ryuhei Jinushi;Rie Shiomi;Takahiro Shin;Kei Sugimoto;Tomoaki Tashima;Yumi Mashimo;Shomei Ryozawa
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.237-245
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) using Franseen needles is reportedly useful for its high diagnostic yield. This study compared the diagnostic yield and puncturing ability of EUS-TA using 22-gauge cobalt-chromium (CO-Cr) needles with those of stainless-steel Franseen needles in patients with solid pancreatic lesions. Methods: Outcomes were compared between the 22-gauge Co-Cr Franseen needle (December 2019 to November 2020; group C) and stainless-steel needle (November 2020 to May 2022; group S). Results: A total of 155 patients (group C, 75; group S, 80) were eligible. The diagnostic accuracy was 92.0% in group C and 96.3% in group S with no significant intergroup differences (p=0.32). The rate of change in the operator (from training fellows to experts) was 20.0% (15/75) in group C and 7.5% (6/80) in group S. Stainless-steel Franseen needles showed less inter-operator difference than Co-Cr needles (p=0.03). Conclusions: Both Co-Cr and stainless-steel Franseen needles showed high diagnostic ability. Stainless-steel Franseen needles are soft and flexible; therefore, the range of puncture angles can be widely adjusted, making them suitable for training fellows to complete the procedure.

Magnetic properties and the shapes of magnetic domain for $CoCr_{16.2}Pt_{10.8}Ta_4$ alloy films with the prior deposition of Ti layer ($CoCr_{16.2}Pt_{10.8}Ta_4$ 합금박막의 Ti 우선증착에 따른 자기적 특성과 자구형상변화)

  • 이인선;김동원
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 2000
  • A quaternary alloy film of $CoCr_{16.2}Pt_{10.8}Ta_4$was investigated for its magnetic properties and c-axis orientation with and without Ti underlayer. Additional elements such as Ta, Pt have been frequently introduced in CoCr alloy film for perpendicular recording as a means of improving magnetic performance. It has been reported that the addition of Pt and Ta in CoCr increase the coercivity and the magnetic isolation of columnar grains, respectively. However, CoCrPtTa perpendicular magnetic layer should be more increased its perpendicular magnetic anisotropy than at present for the application of ultrahigh recording density. The improvement of underlayers and substrate materials is one of the promised schemes to intensify the perpendicular magnetic anisotropy. In this study, the insertion of Ti underlayer shows the remarkable improvement of c-axis orientation compare with the direct deposition on the bare glass. The mechanism about this effect of Ti underlayer on CoCrPtTa is not to be clarified yet. Meanwhile, it is found that the magnetic domain of CoCrPtTa on 20 nm Ti underlayer has the continuous stripe pattern but the one of CoCrPtTa on 90 nm Ti underlayer shows the discrete mass type from the results of MFM investigation. This phenomenon is to be a distinct evidence that the improvement of perpendicular anisotropy by the adoption of Ti underlayer is originated from the reinforcement of the grain boundary segregation in CoCrPtTa alloy. Moreover, the transition of the M-H hysteresis pattern with the thickness of Ti underlayer indicates that the major contribution of Ti underlayer is not the magnetocrystalline anisotropy but the shape anisotropy due to the formation of uniform columnar grains by the nonmagnetic alloy segregation.

  • PDF

Comparison of the Marginal Fitness of Ceramic Co-Cr Metal Crown (도재용 코발트-크롬 금속관의 변연적합도 비교)

  • Jeon, Byung-Wook;Kim, Bu-Sob
    • Journal of Technologic Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: In this study, the marginal fitness of ceramic Co-Cr metal crown made by precision casting, milling, and selective laser melting method were compared. Methods: The ceramic Co-Cr metal crown manufactured by precision casting used the lost wax(LC specimen) method. The abutment were scanned and then made by milling(CM specimen), selective laser melting(CS specimen) method. The specimen were cut bucco-lingual and mesio-distal, and absolute marginal discrepancy and marginal gap were measured using a digital microscope. The surface roughness of the crown was also observed. Results: On the bucco-lingual axial, absolute marginal discrepancy was the LC specimen $31.72({\pm}4.58){\mu}m$, the CM specimen $78.29({\pm}3.28){\mu}m$ and the CS specimen $143.13({\pm}3.83){\mu}m$, respectively. On the bucco-lingual axial, marginal gap was the LC specimen $22.70({\pm}1.46){\mu}m$, the CM specimen $22.70({\pm}1.49){\mu}m$ and CS specimen $99.60({\pm}1.57){\mu}m$, respectively. Conclusion: For ceramic Co-Cr metal crowns, LC specimen was superior for absolute marginal discrepancy and marginal gap. The surface of metal crowns by selective laser melting were the roughest.

Study of High Temperature Corrosion Behavior of Fe-Cr Steel in Sewage Sludge-(SO2-O2-H2O-bal. CO2) mixed Gas Environment (하수슬러지-(SO2-O2-H2O-bal. CO2) 혼합 가스 분위기에서 Fe-Cr 강의 고온부식거동 연구)

  • Kim, Min Jung;Park, Joo Chang;Ryu, In Sun
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.2
    • /
    • pp.72-79
    • /
    • 2020
  • Two Fe-Cr steels of T22 steel and STS430 steel were corroded at 650 and 750℃ for 100hr in sewage sludge-(0.3% SO2-6% O2-10% H2O-balance CO2) mixed gas environment. T22 steel corroded faster than STS430, indicating that the Cr content significantly influence the corrosion rates. T22 formed thick and non-protective Fe2O3 as the major oxide and Fe3O4 as the minor one. With an increase in corrosion temperature, their corrosion rates increased, being accompanied with formation of pores and cracks in the thickened oxide scales that were non-adherent. STS430 steel formed Fe2O3, Fe3O4 as the outer scale and (Fe, Cr)-O as the inner layer by which its corrosion rate is greatly reduced. Both the T22 and STS430 steel samples formed multi-layered scales by outward diffusion of Fe ions and inward diffusion of oxygen and sulfur ions at high-temperature more than 650℃.