• Title/Summary/Keyword: Co 치료기

Search Result 141, Processing Time 0.026 seconds

A Design and Implementation of CO2 Infuser for a Carbon Dioxide (카복시 테라피용 CO2 주입기의 설계 및 구현)

  • Park, Sung-Kon;Ahn, Chan-Jin
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.483-492
    • /
    • 2015
  • This thesis analysis the CARBO 3000 that is one of a $CO_2$ infuser and improve its effectiveness. The thesis designs H/W and S/W that controls the $CO_2$ infusing mass compared to the CARBO 3000. Specially the designed H/W has a newly CPU, LCD, a flow velocity controller, a solenoid valve and a flow sensor. Also the designed S/W is composed of GUI and the algorithm to control the $CO_2$ infusing mass. The designed and implemented the $CO_2$ Infuser in this thesis is tested for the performance. The commercial measuring sensor is used for the test. The testing results say that the designed and implemented the $CO_2$ Infuser in this thesis is much more accurate compared to the CARBO 3000 on $CO_2$ infusing.

Evaluation of the possibility of clinical application by surface dose measurement of ViewRay in MFW treatment (MFW 치료 시 ViewRay의 표면선량 측정에 따른 임상 적용 가능성 평가)

  • Sun, Geo Jun;Son, Sang Jun;Lee, Yang Hoon;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.169-176
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate clinical applicability of Co-60 ViewRay treatment plan to increase the skin dose in case of high skin dose is required such as Malignant Fungating Wound By measuring the presence / absence of Bolus application and skin dose by the treatment device and comparing it Materials and Methods : Nine inner measuring points of 2.5 cm lattice arrangement and all 13 measuring points including upper and lower left and right measuring points touching the chest and skin were marked. After CT was taken, each treatment plan was formulated through Eclipse and ViewRay-TPS, and a Fixed beam-IMRT treatment plan was formulated so that the left chest V2Gy=95 % is delivered. Before measurement QED detector was calibrated and the QED detector was positioned at the 13 measurement points displayed on Phantom and surface dose of each treatment planner was measured using 5 mm Bolus application using True-beam and View-ray before and after, measure three times and compare each before applying 5 mm Bolus. Results : The surface dose of the Co-60 ViewRay and the linear accelerator appeared at $76.8%{\pm}5.2%$ vs. $67.3{\pm}%7.5%$ and the surface dose after application of 5 mm Bolus was $87.6%{\pm}8.9%$ vs. $80.3%{\pm}10.2%$ It was measured at 10.2 % (p<0.001). Conclusion : As a result of the surface dose measurement of each treatment instrument, Co-60 ViewRay confirmed that the surface dose reached 95.6 % of 6 MV Linac with conventional 5 mm bolus, despite not using Bolus (p<0.001). Also, by utilizing magnetic resonance images for each treatment, it is possible to observe the change in the treatment site without the problem of exposure, it is easy to formulate an adaptive treatment plan and it is easy to secure the skin dose, so the size In the case of Malignant Fungating Wound patients who need fast skin changes and need high skin doses, Co-60 ViewRay is considered to be more useful than linear accelerators.

  • PDF

Construction of Semi-universal Wedge Filter and Clinical Application for Co-60 Teletherapy Unit (코발트60 원격치료기에 대한 Semiuniversal Wedge Filter의 제작과 임상응용)

  • Kim, Myung-Ho;Yun, Suk-Rok;Shin, Dong-Oh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.3 no.1
    • /
    • pp.45-50
    • /
    • 1989
  • Wedge filter are used in high energy radiation therapy to obtain uniform isodose lines at small volume tumor and irregular body surface. The aim of this study is not only to describe the method of construction and setting of semi-universal wedge filter for $^{60}Co$ radiation therapy but also to get the optimum treatment planning by clinical application of wedge filter.

  • PDF

The Remedial Effect Measurement of an Obesity Remedy Machine for Home Use (새로운 가정용 비만치료기의 비만치료효과 측정)

  • Lee Jae-Hoon;Lee Dong-Hyung
    • Science of Emotion and Sensibility
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2005
  • This paper reports the remedial effect measurement of an obesity remedy machine for home use which has been developed by H Co. and the authors. It is expected that the machine enhances it's remedial effect and usability by utilizing medium frequency and thermotherapy belt etc. In order to measure it's remedial effect, a clinical experiment, which participates eight young female subjects, has been conducted for one month. The experiment includes the measurements on the changes of Gas-Exchange Responses of subjects through Cardio-Pulmonary Exercise Testing. The experimental results show that the obesity remedy machine helps the subjects to reduce their weights, fat rates, and $VCO_2s$. Thus, it turns out that the machine can be a good candidate for medical treatment on the obesity.

  • PDF

STATISTICAL CORRELATION ANALYSIS OF CVM, SMI AND MANDIBULAR LENGTH WITH NORMAL OCCLUSION IN GROWING CHILDREN (소아청소년기 정상 교합 아동에서 경추골 및 수완부골 성숙도에 대한 하악골 성장의 연관성)

  • Kim, Soo-Yung;Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.357-365
    • /
    • 2012
  • There are orthodontic treatment which involves tooth movements and orthopedic treatment which involves skeletal movement. In childhood and adolescence, especially for the treatment of orthopedic treatment, the evaluation of bone maturity and growth potential is very important. The purpose of this study is to assess the developmental stage and to compare the amount of mandibular growth with cephalometric radiographs and hand-wrist radiograph in 6 to 13-year-old children with normal occlusion. The results are as follows : SMI and CVM showed a significant correlation (p < 0.05). Ar-Go, Co-Go, N-Go, S-Gn, N-Me, Co-Gn, Go-Me, Go-Gn increased with increasing maturity of hand-wrist and Ar-Go, Co-Go, N-Go, S-Gn, N-Me, Co-Gn, Go-Me, Go-Gn increased with increasing maturity of cervical vertebrae maturation. Also Ar-Go, Co-Go, N-Go, S-Gn, N-Me, Co-Gn, Go-Me, Go-Gn showed a significant correlation with each of the cervical vertebrae maturation stages and hand-wrist maturation stages (p < 0.05). These results suggested that mandibular growth had a significant correlation with cervical vertebrae maturation stages and hand-wrist maturation stages.

Development of High Voltage Power Supply for A-BNCT (A-BNCT(Boron Neutron Capture Therapy) 시스템 구동을 위한 고전압 전원장치개발)

  • Lee, kyunkyu;Park, S.S.;Choi, B.H.;Kim, D.S.;Kim, Y.W.;Kim, H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.638-641
    • /
    • 2018
  • 현재 선진국에서는 고출력 양성자 선형 가속기를 기반으로 한 의료용 암치료기인 BNCT(Boron Neutron Capture Therapy)에 대해 활발히 연구 중이며 다원시스도 2016년부터 A-BNCT 사업을 진행 중이다. A-BNCT에 적용된 양성자 선형 가속기의 RF(Radio Frequency)전원을 공급하기 위해 352 MHz, 1.5 MW의 고출력을 가지는 클라이스트론을 사용하였다. 클라이스트론의 출력인 RF의 크기와 위상을 안정적으로 제어하기 위해 90 kV, 30 A, 120 Hz, 1.7 ms의 구형파 출력을 가지는 고전압 전원장치를 적용하였다. 또한 고전압 전원장치의 출력전압 변동률을 0.5% 이내로 유지시키기 위해 전압보상회로를 적용하여 회로 시뮬레이션과 실부하 실험을 통해 펄스전원장치의 성능을 검증하였다.

  • PDF

A Study on the dosimetry in boundary of shielding block in high energy irradiation (고에너지 방사선치료에서 차폐물 경계부위의 선량분포에 관한 고찰)

  • Kim, Myung-Se;Kim, Sung-Kyu;Shin, Sei-One
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.115-120
    • /
    • 1990
  • Scatter-air ratios are used for the purpose of calculating scattered dose in the medium. The computation of the primary and the scattered dose separately is particularly useful in the dosimetry of irregular fields with shielding block in radiation field, dose distribution of scattered radiation using 18MeV Linear accelerator and Co-50 teletherapy measured. The effect of scattered radiation dose by protecting block was been ignored in radiation therapy, 2-3% of scattered radiation may be 90-200 cGy which could be influence vitial complications such as cataract, oligospermia or sterility. So that exect calculation of such scattered radiation especially for large field $\bar{c}$ small protection of vitial organ is very important. The purpose of this article is to calculate scattered radiation by protecting block exactly for irregular field $\bar{c}$ Linac or Co-60 irradiation and to applicate these data in clinical radiation field. Authors could obtain following results. 1. The lesser angle between shielding block showed more scattered radiation. 2. With decreasing distance between shielding blocks, the dependent of scattered radiation were increased. 3. Output of 18MeV Linear accelerator and Co-60 was related linear proportion on field size, but independent according to the size of shielding block in 18MeV Linear accelerator.

  • PDF

A Measurement of Kerma and Absorbed Dose in Photon Fields (Photon Beam에 대한 Kerma와 흡수선량의 측정)

  • Kim, Sung-Hee;Shin, Seung-Aea;Chu, Sung-Sil
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.77-82
    • /
    • 1986
  • Determination of the relation between the kerma(Kinetic Energy Released in Material) and the absorbed dose is one of the basic problems of dosimetry. Kerma and absorbed dose were measured for 6 MV X-ray from the high energy medical linear accelerator and $^{60}Co$ gamma-ray. The experimental results show that the absorbed dose in the transient equilibrium region practically coincide with the kerma in water and Al for $^{60}Co$. The maximum dose depths were $1.45g/cm^2$ for 6MV X-ray and $0.48g/cm^2\;for\;^{60}Co$ gamma-ray. The ratios of the absorbed dose at maximum build-up to the collision kerma at the surface, ($K^{att}$), were 0.949 for 6MV X-ray and 0.992 for $^{60}Co$ gamma-ray. No difference was found between water and Al when the standard field size was used. This results show that the dependence of $K^{att}$ on the material is very small.

  • PDF

Extraction of the Liver from Computed Tomography Using Co-occurrence Matrix (Co-occurrence Matrix를 이용한 CT 영상에서 간 영역의 추출)

  • 이성기
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • 의료영상 처리는 의료 전문가들이 의료영상을 이용한 진단, 치료, 및 연구를 함에 있어 중요한 역할을 하고 있다. 많은 영상 분할 방법들이 의료영상 처리분야에서 성공적으로 사용되고 있다. 본 논문에서는 CT 영상에서 간 영역을 자동으로 추출하는 방법을 제시한다. 본 논문에서는 간 영역을 추출하기 위해 co-occurrence matrix를 적용하였고, 추출된 영역에서 뼈와 근육, 신장 영역을 제거하였다. 제안된 방법은 의료 전문가가 추출한 결과와 비교하여 좋은 결과를 보여주었다.

  • PDF