• Title/Summary/Keyword: Co(II) determination

Search Result 61, Processing Time 0.022 seconds

Extraction of Water-Soluble Porphyrin and Metalloporphyrins into Acetonitrile by Salting-out

  • Tabata, Masaaki;Kumamoto, Midori
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.511-517
    • /
    • 1995
  • A cationic water soluble porphyrin (5,10,15,20-tetrakis (l-methyl-pyridinium-4-yl)porphyrin, $H_2tmpyp^{4+}$) and its metalloporphyrins (MP) were easily extracted into acetonitrile separated by addition of sodium chloride ($4mol\;dm^{-3}$) in the presence of sodium perchlorate, where M denotes $Zn^{2+}$, $Cu^{2+}$, $Co^{3+}$, $Fe^{3+}$, and $Mn^{3+}$ and $P^{2-}$ is porphyrinate ion. The extracted ion-pair complexes were completely dissociated to $[MP(ClO_4)_3]^+$, and $[MP(ClO_4)_2]^{2+}$. The extraction and the dissociation constants were determined by taking into account of the partition constant of sodium perchlorate ($K_D=1.82{\pm}0.01$). The chemical properties of the separated acetonitrile phase as $E_{T(30)}$ and $D_{II,I}$ were determined and compared with other water miscible solvents (acetone, actonitrile, 1,4-dioxane, tetrahydrofuran, 1-propanol and 2-propanol). Furthermore, a sensitive and selective method was proposed for the determination of a subnanogram amount of copper(II) in natural water samples by using the present salting-out method and the porphyrins.

  • PDF

Progesterone assays as an aid for improving reproductive efficiency in dairy cattle II. Use of plasma or milk progesterone profiles for differential diagnosis of ovarian cysts (Progesterone 농도측정(濃度測定)에 의한 유우(乳牛)의 번식효율증진(繁殖效率增進)에 관한 연구(硏究) II. 혈액(血液) 및 유즙(乳汁)중 progesterone 농도측정(濃度測定)에 의한 난소낭종(卵巢囊腫)의 감별진단(鑑別診斷))

  • Kang, Byong-kyu;Choi, Han-sun;Choi, Sang-gong;Son, Chang-ho;Chon, Hong-suk
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.1
    • /
    • pp.181-188
    • /
    • 1994
  • In 60 dairy cows with inactive ovaries, follicular cyst, luteal cyst, persistent corpus luteum and silent heat as diagnosed by rectal palpation, and those that had not resumed ovarian cycles until 60 days postpartum, progesterone concentrations for differential diagnosis of reproductive disorders were measured and were compared in matched plasma, skim milk and milk fat samples at 10 days interval. The incidence rate of reproductive disorders were as follows; inactive ovaries 20(33.3%), silent heat 11(18.3%), follicular cyst 7(11.7%), luteal cyst 7(11.7%), persistent corpus luteum 7(11.7%), pyometra 4(6.7%), vaginitis 2(3.3%), cystic corpus luteum 1(1.7%), and endometritis 1(1.7%), respectively. Cows having a progesterone concentration in plasma and skim milk < 1.0 ng/ml, and in milk fat < 80.0 ng/ml were considered to have inactive ovaries or follicular cyst. Those with concentrations in plasma and skim milk ${\geq}1.0ng/ml$, and in milk fat ${\geq}80.0ng/ml$ were regarded as the cases of luteal cyst or persistent corpus luteum. Progesterone concentrations in above cows did not differ significantly between the time of initial determination and the 10 days after initial determination. But progesterone concentrations in cows with silent heat did differ significantly between the time of initial determination and the 10 days after initial determination(P<0.05). The accuracy of rectal palpation for making a differential diagnosis of ovarian dysfunction, as defined on basis of progesterone concentrations, were as follows; follicular cyst 55.6%, luteal cyst 50.0%, inactive ovaries 90.5% and persistent corpus luteum 60.0%, respectively. It may be concluded that progesterone determinations at 10 days interval is practical as an aid to diagnosing ovarian dysfunction, particularly follicular cyst and luteal cyst.

  • PDF

High throughput automated 96-well solid-phase extraction and liquid chromatography-tandem mass spectrometric analysis of beraprost in human plasma

  • Chang, Kyu-Young;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.224.1-224.1
    • /
    • 2003
  • A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the determination of beraprost in human plasma. Plasma samples were transferred into 96-well OASIS HLB extraction plate using an automated sample handling system and the drugs were eluted with methanol. The eluents were then evaporated and reconstituted with water. All sample transfer and solid-phase extraction (SPE) was automated through the application of both the PerkinElmer MultiPROBE II HT and TOMTEC Quadra 96 workstation. (omitted)

  • PDF

The Determination of the Sand Drift Movement Using Radioactive Tracer at Young Il Bay (방사성 동위원소를 이용한 영일만 해역표사의 조사)

  • Yang, Kyung Rin
    • 한국해양학회지
    • /
    • v.4 no.1
    • /
    • pp.9-16
    • /
    • 1969
  • The sand drift movement at Young Il Bay area was tentatively investigated using Co-60 glass sand. Grain size and specific gravity of the glass sand which has originally contained natural cobalt, Co-59, was made similar to those of the real coastal sand, and was irradiated in a beam port of the reactor Triga Mark II to make the glass sand radioactive by the reaction of 59Co(n, r)60Co. The radioactive cobalt glass sand was deposited on the preselected point of sea bed, and, after a couple of weeks, the drift of sand was traced by means of specially designed water-proof G-M detector. Net counts at each point were plotted to figure out equicount lines and consequently such aspects as the direction of sand drift movement, the scope of distribution and the relative drift velocity etc. were indicated.

  • PDF

Synthesis of Heptadentate Nitrogen-Oxygen Ligands (N4O3) with Substituting Groups and Determination of Stability Constants of Their Transition Metal(II) Complexes (치환기를 가진 일곱 자리 질소-산소(N4O3)계 리간드 합성과 전이금속(II) 이온 착물의 안정도상수 결정)

  • Kim, Sun-Deuk;Lee, Do-Hyub;Seol, Jong-Min
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.541-550
    • /
    • 2010
  • A new $N_4O_3$ heptadentate ligand, N,N'-Bis(2-hydroxybenzyl)-1,3-bis[(2-aminoethyl)amino]-2-propanol(H-BAP 4HCl)was synthesized. The hydrochloric acid salts of Br-BAP 4HCl, Cl-BAP 4HCl, $CH_3O$-BAP 4HCl and $CH_3$-BAP 4HCl containing Br-, Cl-, H-, $CH_3O-$ and $CH_{3^-}$ groups at the para-site of the phenol group of the H-BAP were synthesized. The structures of the ligands were confirmed by C. H. N. atomic analysis and $^1H$ NMR, $^{13}C$ NMR, UV-visible and mass spectra. The elemental stepwise protonation constants(${logK_n}^H$) of the synthesized $N_4O_3$ ligands showed six steps of the proton dissociation. The orders of the overall dissociation constants($log{\beta}_p$) of the ligands were Br-BAP < Cl-BAP < H-BAP < $CH_3O$-BAP < $CH_3$-BAP. The orders agreed well with that of Hammett substituent constants($\sigma_p$). The calculated stability constants($logK_{ML}$) between the ligands and transition metal ions agreed well with the order of the overall proton dissociation constants of the ligands but they showed a reverse order in Hammestt substituent constants($\sigma_p$). The order of the stability constants between the transition metal ions with the ligands were Co(II) < Ni(II) < Cu(II) > Zn(II) > Cd(II) > Pb(II).

Determination of global ice loads on the ship using the measured full-scale motion data

  • Lee, Jae-Man;Lee, Chun-Ju;Kim, Young-Shik;Choi, Gul-Gi;Lew, Jae-Moon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.301-311
    • /
    • 2016
  • This paper describes the whole procedures to determine ice-induced global loads on the ship using measured full-scale data in accordance with the method proposed by the Canadian Hydraulics Centre of the National Research Council of Canada. Ship motions of 6 degrees of freedom (dof) are found by processing the commercial sensor signals named Motion Pak II under the assumption of rigid body motion. Linear accelerations as well as angular rates were measured by Motion Pak II data. To eliminate the noise of the measured data and the staircase signals due to the resolution of the sensor, a band pass filter that passes frequencies between 0.001 and 0.6 Hz and cubic spline interpolation resampling had been applied. 6 dof motions were computed by the integrating and/or differentiating the filtered signals. Added mass and damping force of the ship had been computed by the 3-dimensional panel method under the assumption of zero frequency. Once the coefficients of hydrodynamic and hydrostatic data as well as all the 6 dof motion data had been obtained, global ice loads can be computed by solving the fully coupled 6 dof equations of motion. Full-scale data were acquired while the ARAON rammed old ice floes in the high Arctic. Estimated ice impact forces for two representative events showed 7e15 MN when ship operated in heavy ice conditions.

Determination of Optimal Design Level for the Semiconductor Polishing Process by Taguchi Method (다구찌 기법을 활용한 반도체 연마 공정의 최적 설계수준 결정)

  • Sim, Hyun Su;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.2
    • /
    • pp.293-306
    • /
    • 2017
  • Purpose: In this study, an optimal design level of influencing factors on semiconductor polishing process was determined to minimize flexion of both sides on wafers. Methods: First, significant interactions are determined by the stepwise regression method. ANOVA analysis on SN ratio and mean of dependent variable are performed to draw mean adjustment factors. In addition, the optimal levels of mean adjustment factors are decided by comparing means of each level of mean adjustment factors. Results: As a result of ANOVA, a mean adjustment factor was determined as a width of formed flexion on the plate. The mean of the difference has the nearest to 0 in the case when the width of formed flexion has level 2 (4mm). Conclusion: Optimal design levels of semiconductor polishing process are determined as follows; (i) load applied to the wafer carrier has a level 1 (3psi), (ii) load applied to the wafer has a level 1(3psi), (iii) the amount of slurry supplied during polishing has a level 3 (300 co/min), (iv) the width of formed flexion on the plate has level 2 (4mm).

Ex-situ Reductive Dechlorination of Carbon Tetrachloride by Iron Sulfide in Batch Reactor

  • Choi, Kyung-Hoon;Lee, Woo-Jin
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.177-183
    • /
    • 2008
  • Ex-situ reductive dechlorination of carbon tetrachloride (CT) by iron sulfide in a batch reactor was characterized in this study. Reactor scaled-up by 3.5 L was used to investigate the effect of reductant concentration on removal efficiency and process optimization for ex-situ degradation. The experiment was conducted by using both liquid-phase and gas-phase volume at pH 8.5 in anaerobic condition. For 1 mM of initial CT concentration, the removal of the target compound was 98.9% at 6.0 g/L iron sulfide. Process optimization for ex-situ treatment was performed by checking the effect of transition metal and mixing time on synthesizing iron sulfide solution, and by determining of the regeneration time. The effect of Co(II) as transition metal was shown that the reaction rate was slightly improved but the improvement was not that outstanding. The result of determination on the regeneration time indicated that regenerating reductant capacity after $1^{st}$ treatment of target compound was needed. Due to the high removal rates of CT, ex-situ reductive dechlorination in batch reactor can be used for basic treatment for the chlorinated compounds.

Studies on X-Ray Fluorescence Analysis of Sulfide Ores by Solution Technique (II). Analysis of Iron, Copper and Cobalt (용액법을 이용한 황화광석의 X-선 형광분석에 관한 연구 (제2보). 철, 구리 및 코발트의 분석)

  • Young-Sang Kim;Kee-Chae Park
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.320-325
    • /
    • 1982
  • Utilyzing the solution prepared for the sulfur determination, the amounts of iron, copper and cobalt in the sulfide ore were determined by X-ray fluorescence spectrometry. The samples were dissolved with the mixed solutions of ,$Br_2\;and\;HNO_3$ and a major constituent of $SiO_2$was repelled from the solution by HF treatment several times. The analytical results agreed with the data obtained by conventional methods within ${\pm}$1.5% for Fe of the range of 20 to 50%, ${\pm}$1.0% for Cu of 10 to 15%, and ${\pm}$0.4% for Co of 1 to 5%. The present method was tolerably found to be reproducible.

  • PDF

Optimal Determination of Pipe Support Types in Flare System for Minimizing Support Cost (비용 최소화를 위한 플래어 시스템의 배관 서포트 타입 최적설계)

  • Park, Jung-Min;Park, Chang-Hyun;Kim, Tea-Soo;Choi, Dong-Hoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.4
    • /
    • pp.325-329
    • /
    • 2011
  • Floating, production, storage and offloading (FPSO) is a production facility that refines and saves the drilled crude oil from a drilling facility in the ocean. The flare system in the FPSO is a major part of the pressure relieving system for hydrocarbon processing plants. The flare system consists of a number of pipes and complicated connection systems. Decision of pipe support types is important since the load on the support and the stress in the pipe are influenced by the pipe support type. In this study, we optimally determined the pipe support types that minimized the support cost while satisfying the design constraints on maximum support load, maximum nozzle load and maximum pipe stress ratio. Performance indices included in the design constraints for a specified design were evaluated by pipe structural analysis using CAESAR II. Since pipe support types were all discrete design variables, an evolutionary algorithm (EA) was used as an optimizer. We successfully obtained the optimal solution that reduced the support cost by 27.2% compared to the initial support cost while all the design requirements were satisfied.