The Transactions of the Korean Institute of Electrical Engineers A
/
v.53
no.1
/
pp.31-37
/
2004
In this paper, the analysis result of the switching surge in substation including GIS(Gas Insulated Switchgear) has been described using the EMTP(Electro Magnetic Transient Program) program. After performing the modeling of the input data, we have reviewed the energization overvoltages of GCB(Gas Circuit Breaker) without closing resistor in 345kV network, according to the conditions of simultaneously operating switch and statistically operating switch. Firstly, it can be known that the energization overvoltage of single line is higher than that of parallel energized line. Secondly, the maximum energization overvoltage obtained in statistics switch is higher than one in simultaneous switch. From these results, it can be known that the phase-to-earth energization overvoltages of $\alpha$-$\beta$ section are less than 2.2 p.u when closing resistor is eliminated. Therefore, it is possible to consider the circuit breaker eliminated the closing resistor in $\alpha$-$\beta$ section.
Cho, Chu-Hyun;Lee, Hong-Sik;Rim, Geun-Hie;Pavlov, E.
Proceedings of the KIEE Conference
/
1999.07e
/
pp.2239-2241
/
1999
The most important question is how to use which kind of switch in pulsed power generation. There are many kinds of commercial closing switches, which have advantages and disadvantages. The most popular closing switch is the spark gap, but it has a disadvantage in life time, because of erosion of electrodes by arc heating. The Rotary Arc Gap (RAG) switch, especially Walkie-Edgar type RAG switch, was proposed to solve such problems in spark gap. It has a simple and special structure for arc moving caused from self-induced electromagnetic force, because moving arc makes less erosion on the electrodes. In this study we have made an Walkie-Edgar type RAG switch, tested the switching with capacitive energy storage system, and measured rotating arc speed in different peak current.
Seo, Kil-Soo;Kim, Young-Bae;Cho, Kuk-Hee;Lee, Hyeong-Ho
The Transactions of the Korean Institute of Electrical Engineers C
/
v.49
no.12
/
pp.679-684
/
2000
Closing switch, key component of pulsed power system, is constructed simply and used frequently due to the easy control and manufacture of one. The kind of one are spark-gap, triggered vacuum switch, pseudo-spark switch and INPIStron. But the electrode of spark gap switch is damaged with the hot spot by Z-pinch and then the life of one become short. INPIStron with inverse pinch effect has long life but it is difficult trigger system to provide uniform discharge between cathode and anode. In this paper, the design and manufacturing of INPIStron with gas puffing trigger method in order to supply uniform discharge inter-electrode and the performance of the developed INPIStron applied to 500[kA]-2[MJ] pulsed power system is presented.
Seo, Kil-Soo;Kim, Young-Bae;Cho, Kook-Hee;Lee, Hyeong-Ho
Proceedings of the KIEE Conference
/
1999.07e
/
pp.2173-2175
/
1999
This paper presents the development of closing switch for high voltage and current in detail. Design concept of INPIStron triggered by the gas puffing, voltage hold-off, current capacity, insulating and electrode material, rise time etc, are described. Also for the dptimized design of the electrical triggering switch, pin, ring, wire brush, surface discharge and HCP(Hypo-Cycloidal Pinch) trigger are considered.
The Journal of the Korea institute of electronic communication sciences
/
v.16
no.6
/
pp.1287-1294
/
2021
This paper is a study on the implementation of a sensor-based smart compression system for improving home and street environments. Since modernization, the amount of garbage has been increasing every year, and this has seriously adversely affected not only people but also ecosystems such as marine pollution and soil pollution. In particular, in large cities with large floating populations, garbage is dumped on the streets without proper measures to deal with the amount of waste generated. In order to improve this problem, this paper intends to implement a system with automatic compression and opening/closing functions using sensors. This system is designed to activate automatic opening/closing function through an infrared sensor, and automatically opening and closing when the inclination is changed using an impact sensor. In addition, by installing a distance sensor, the amount of internal waste can be easily monitored from the outside, and a manual compression switch and a manual opening/closing switch is separately designed to enable opening and closing and compression as needed to increase the effectiveness.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.20
no.10
/
pp.120-125
/
2006
In contrast to the conventional trigatron switch in which the currents are constricted by the z-pinch mechanical the new switch operates in an inverse pinch geometry formed by a pair of spiral electrodes in a sealed-off type. Inverse pinch switch greatly reduces hot spot formations and protects the electrode surfaces. The switch can be initiated with an electrical trigger electrode. Advantages of the new switch over the conventional switches are longer useful life, high current capability and lower inductance due to the dispersed and moving current sheet. These improved characteristics may make the inverse pinch switch suitable for pulse power systems.
A limit switch box is used for an indicator of a valve actuator. This device indicates an opening and closing of a valve or a throttle in the valve actuator. In a ship, equipments require safety and robustness because of a rough environment and a specific condition during a voyage. However, the limit switch box has been used in an indoor environment generally. This study developed a new limit switch box which can be used at an outdoor environment. This study designed the new limit switch box. The housing of the limit switch box was made by an aluminum die cast method with surface painting after anodizing or chromate coating. In order to evaluate the endurance of the housing, the endurance tests against salt water have been conducted. Experiment results showed that the proposed device provides a reliable performance against salt water.
The Transactions of the Korean Institute of Electrical Engineers C
/
v.52
no.1
/
pp.19-24
/
2003
Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.
Seo, Kil-Soo;Kim, Young-Bae;Cho, Kuk-Hee;Lee, Hyeong-Ho
Proceedings of the KIEE Conference
/
1999.11d
/
pp.1069-1071
/
1999
Closing switch는 여러 가지가 있으나, 방전시 발생하는 Z-pinch로 인한 전극의 손상으로 수명이 짧고, 소음, 열 발생 등으로 소형화가 문제점으로 되어왔다. Inverse pinch현상을 이용하여 기존의 closing switch보다 전류밀도가 1/62, 주울열의 발생, 인덕턴스가 작다. INPIStron의 수명에 영향을 미치는 절연물질은 세라믹을, 도전체로서는 경제성을 감안하여 쉽게 구할 수 있는 구리를 이용하여 제작하였고, 트리거는 gas-puffing방식을 사용하였다. 또한 이렇게 제작된 INPIStron을 이용하여 2MJ-500kA급 pulsed power 전원 장치를 개발하였다.
Kim, S.H.;Choi, B.Y.;Cho, S.H.;Son, I.B.;Moon, Y.H.
Proceedings of the KIEE Conference
/
1996.07b
/
pp.686-688
/
1996
Network reconfiguration is performed by opening/closing two types of switches, tie and sectionalizing switches. A whole feeder, or part of a feeder, may be served from another feeder by closing a tie switch linking the two while an appropriate sectionalizing switch must be opened to maintain radial structures. In loss reduction, the problem is to identify tie and sectionalizing switches that should be closed and opened, respectively, to achieve a maximum loss reduction. In this paper, it is introduced to propose the reconfiguration plan for loss reduction by using the Civanlar's loss reduction formular.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.