• Title/Summary/Keyword: Closing switch

Search Result 41, Processing Time 0.034 seconds

The Study on Application of Circuit Breaker without Closing Resistor in Short Transmission Line (단거리송전선에서 투입저항이 없는 차단기적용에 관한 연구)

  • 김정배;정영환;송원표
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.31-37
    • /
    • 2004
  • In this paper, the analysis result of the switching surge in substation including GIS(Gas Insulated Switchgear) has been described using the EMTP(Electro Magnetic Transient Program) program. After performing the modeling of the input data, we have reviewed the energization overvoltages of GCB(Gas Circuit Breaker) without closing resistor in 345kV network, according to the conditions of simultaneously operating switch and statistically operating switch. Firstly, it can be known that the energization overvoltage of single line is higher than that of parallel energized line. Secondly, the maximum energization overvoltage obtained in statistics switch is higher than one in simultaneous switch. From these results, it can be known that the phase-to-earth energization overvoltages of $\alpha$-$\beta$ section are less than 2.2 p.u when closing resistor is eliminated. Therefore, it is possible to consider the circuit breaker eliminated the closing resistor in $\alpha$-$\beta$ section.

A Development of the Rotary Arc Gap Switch for Pulsed High Current Transfer (펄스 대전류 Rotary Arc Gap 스위치 개발)

  • Cho, Chu-Hyun;Lee, Hong-Sik;Rim, Geun-Hie;Pavlov, E.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2239-2241
    • /
    • 1999
  • The most important question is how to use which kind of switch in pulsed power generation. There are many kinds of commercial closing switches, which have advantages and disadvantages. The most popular closing switch is the spark gap, but it has a disadvantage in life time, because of erosion of electrodes by arc heating. The Rotary Arc Gap (RAG) switch, especially Walkie-Edgar type RAG switch, was proposed to solve such problems in spark gap. It has a simple and special structure for arc moving caused from self-induced electromagnetic force, because moving arc makes less erosion on the electrodes. In this study we have made an Walkie-Edgar type RAG switch, tested the switching with capacitive energy storage system, and measured rotating arc speed in different peak current.

  • PDF

Development of Gas Puffing INPIStron for Pulsed Power Supply (Pulsed Power전원장치용 Gas Puffing INPIStron의 개발)

  • Seo, Kil-Soo;Kim, Young-Bae;Cho, Kuk-Hee;Lee, Hyeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.12
    • /
    • pp.679-684
    • /
    • 2000
  • Closing switch, key component of pulsed power system, is constructed simply and used frequently due to the easy control and manufacture of one. The kind of one are spark-gap, triggered vacuum switch, pseudo-spark switch and INPIStron. But the electrode of spark gap switch is damaged with the hot spot by Z-pinch and then the life of one become short. INPIStron with inverse pinch effect has long life but it is difficult trigger system to provide uniform discharge between cathode and anode. In this paper, the design and manufacturing of INPIStron with gas puffing trigger method in order to supply uniform discharge inter-electrode and the performance of the developed INPIStron applied to 500[kA]-2[MJ] pulsed power system is presented.

  • PDF

Optimized Design Technology of Closing Switch for High Voltage & Current (고전압/대전류 투입스위치의 최적설계기술)

  • Seo, Kil-Soo;Kim, Young-Bae;Cho, Kook-Hee;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2173-2175
    • /
    • 1999
  • This paper presents the development of closing switch for high voltage and current in detail. Design concept of INPIStron triggered by the gas puffing, voltage hold-off, current capacity, insulating and electrode material, rise time etc, are described. Also for the dptimized design of the electrical triggering switch, pin, ring, wire brush, surface discharge and HCP(Hypo-Cycloidal Pinch) trigger are considered.

  • PDF

A Study on the Implementation of a IoT Sensor-based Smart Compression System (센서 기반의 스마트 압축 시스템 구현에 대한 연구)

  • Oh, Eun-Young;Yoon, Keun-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1287-1294
    • /
    • 2021
  • This paper is a study on the implementation of a sensor-based smart compression system for improving home and street environments. Since modernization, the amount of garbage has been increasing every year, and this has seriously adversely affected not only people but also ecosystems such as marine pollution and soil pollution. In particular, in large cities with large floating populations, garbage is dumped on the streets without proper measures to deal with the amount of waste generated. In order to improve this problem, this paper intends to implement a system with automatic compression and opening/closing functions using sensors. This system is designed to activate automatic opening/closing function through an infrared sensor, and automatically opening and closing when the inclination is changed using an impact sensor. In addition, by installing a distance sensor, the amount of internal waste can be easily monitored from the outside, and a manual compression switch and a manual opening/closing switch is separately designed to enable opening and closing and compression as needed to increase the effectiveness.

A Study on New Inverse Pinch Switch for High Power Transfer (High Power 전달을 위한 새로운 Inverse Pinch Switch에 관한 연구)

  • Cho, Kook-Hee;Kim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.120-125
    • /
    • 2006
  • In contrast to the conventional trigatron switch in which the currents are constricted by the z-pinch mechanical the new switch operates in an inverse pinch geometry formed by a pair of spiral electrodes in a sealed-off type. Inverse pinch switch greatly reduces hot spot formations and protects the electrode surfaces. The switch can be initiated with an electrical trigger electrode. Advantages of the new switch over the conventional switches are longer useful life, high current capability and lower inductance due to the dispersed and moving current sheet. These improved characteristics may make the inverse pinch switch suitable for pulse power systems.

Development of the Limit Switch Box for a Ship and Its Performance Evaluation against Salt Water

  • Lee, Seung-Heui;Go, Seok-Jo;Lee, Min-Cheol;Kim, Chang-Dong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1334-1338
    • /
    • 2005
  • A limit switch box is used for an indicator of a valve actuator. This device indicates an opening and closing of a valve or a throttle in the valve actuator. In a ship, equipments require safety and robustness because of a rough environment and a specific condition during a voyage. However, the limit switch box has been used in an indoor environment generally. This study developed a new limit switch box which can be used at an outdoor environment. This study designed the new limit switch box. The housing of the limit switch box was made by an aluminum die cast method with surface painting after anodizing or chromate coating. In order to evaluate the endurance of the housing, the endurance tests against salt water have been conducted. Experiment results showed that the proposed device provides a reliable performance against salt water.

  • PDF

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

Development of Pulsed Power Supply using INPIStron (INPIStron을 이용한 Pulsed Power전원장치의 개발)

  • Seo, Kil-Soo;Kim, Young-Bae;Cho, Kuk-Hee;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1069-1071
    • /
    • 1999
  • Closing switch는 여러 가지가 있으나, 방전시 발생하는 Z-pinch로 인한 전극의 손상으로 수명이 짧고, 소음, 열 발생 등으로 소형화가 문제점으로 되어왔다. Inverse pinch현상을 이용하여 기존의 closing switch보다 전류밀도가 1/62, 주울열의 발생, 인덕턴스가 작다. INPIStron의 수명에 영향을 미치는 절연물질은 세라믹을, 도전체로서는 경제성을 감안하여 쉽게 구할 수 있는 구리를 이용하여 제작하였고, 트리거는 gas-puffing방식을 사용하였다. 또한 이렇게 제작된 INPIStron을 이용하여 2MJ-500kA급 pulsed power 전원 장치를 개발하였다.

  • PDF

A Study on Distribution Network Reconfiguration for Loss Reduction (손실감소를 위한 배전계통 재구성에 관한 연구)

  • Kim, S.H.;Choi, B.Y.;Cho, S.H.;Son, I.B.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.686-688
    • /
    • 1996
  • Network reconfiguration is performed by opening/closing two types of switches, tie and sectionalizing switches. A whole feeder, or part of a feeder, may be served from another feeder by closing a tie switch linking the two while an appropriate sectionalizing switch must be opened to maintain radial structures. In loss reduction, the problem is to identify tie and sectionalizing switches that should be closed and opened, respectively, to achieve a maximum loss reduction. In this paper, it is introduced to propose the reconfiguration plan for loss reduction by using the Civanlar's loss reduction formular.

  • PDF